MOLEX 74740-0001

1000Base-T RJ-45 Gigabit
Ethernet GBIC Copper
Transceiver
FEATURES AND SPECIFICATIONS
Features and Benefits
1000Base-T compliant, meets IEEE802.3z, ab
specifications and is GBIC SFF-8053 Rev 5.5
compliant – For improved intermatability
1.63 Watt power requirement – Low heat
output
Hot pluggable – Eliminates need to power
down to remove or install transceiver
Zinc back shells – Improved EMI performance
Auto-negotiation – Allows networking
equipment to automatically determine and
adjust to the required settings
Automatic MDI crossover – Eliminates the
need for crossover cables or cross-wired
(MDIX) ports
Link monitor – Detects loss of signal
Serial ID – Allows individual identification of
each GBIC transceiver
Auto-Power shutdown – Saves energy
Applications
■ Networking Equipment
- Switches
- Routers
74740
Reference Information
Packaging: 1
Mates With: GBIC Cage 73847 series
SCA-2 Receptacle 74065 series
Electrical
Voltage: 5v
Current: 350mA
Physical
Zinc Diecast Backshell
PCB Thickness: .062”
Operating Temperature: 0 to 70° C
The 1000Base-T RJ-45 Gigabit Ethernet GBIC copper transceiver is a high performance integrated duplex data link for bi-directional communication over Cat-5 copper
cable. The hot pluggable feature allows changing to or from another GBIC compatible module without having to remove system power. Serial ID is included.
ORDERING INFORMATION
Order Number
74740-0001
74740-0002
74740-0003
Description
RJ-45 1000Base-T GBIC Transceiver With Serial ID, Auto Negotiation On LOS GND
RJ-45 1000Base-T GBIC Transceiver With Serial ID, Auto Negotiation On LOS Toggle
RJ-45 1000Base-T GBIC Transceiver With Serial ID, Auto Negotiation Off LOS Toggle
FEATURES
Figure 1. RJ-45 GBIC 1000Base-T Application
Host Board
GBIC Card
SERDES
(e.g.)
MAC
TBI
1000Base-T
Transceiver
BCM5421S
I²C Serial
Interface
GBIC
Interface
I²C Serial
Interface
MDC/
MDIO
Transformer
µC
RJ-45
1000Base-T
1000BASE-T RJ-45 GBIC FEATURES
1000Base-T RJ-45 Gigabit
Ethernet GBIC Copper
Transceiver
GBIC Mode
When the internal gigabit Ethernet transceiver (PHY) is configured to GBIC mode, the PHY can interface directly with the host serial/deserial
(SERDES) interface. The host interface transmits and receives serial data differentially at 1.25Gbps. The copper interface is full featured
and advertises full/half duplex, and 1000Base-T wire speed.
Auto-Negotiation
Auto-Negotiation is supported over both the twisted pair copper link and SERDES interface as defined in the IEEE 802.3 standards and is
performed as part of the initial set-up of the link. The copper link is negotiated according to the IEEE 802.3 Clause 28, and Clause 37 is
used in the negotiation of the SERDES interface. The two interfaces advertise 1000Base-T full-duplex, and master/slave relationships. The
master establishes the time control from its local clock source. The slave however recovers the clock from the received data stream. The
GBIC application is limited to 1000Base-T wire speed only. Auto-Negotiation on the SERDES link is always restarted when a change is
detected on copper link (see Link Monitor and Loss-of-Signal for further details).
Automatic MDI Crossover
The 1000Base-T GBIC transceiver performs a MDI crossover during Auto-Negotiation eliminating the need for crossover cables or crosswired (MDIX) ports.
Loss of Signal - Link Monitor
Following Auto-Negotiation, the master and slave begin sending data over the twisted pair link. The master and slave continuously monitor
the copper link for quality of data. The link status bit is set after one microsecond of quality data. If the quality of copper link drops below
factory PHY minimums, the GBIC will drop the SERDES link, and assert the LOS I/O interface (optional) in less than 200 milliseconds.
Auto Power Savings Mode
When the copper link is lost, the GBIC automatically enters a low power mode reducing the chip power requirements. Full power mode
resumes once the copper link is re-established.
Not Implemented in GBIC Auto-Negotiation
Next page exchange and detection of remote faults are not auto-negotiated.
AUTO-NEGOTIATION SUMMARY
Auto-Negotiation Features Supported:
General:
SERDES Auto-Negotiation is restarted when a change is detected on the copper link
Auto power savings mode when copper link is lost
Copper RJ-45 Interface:
Auto-Negotiation
Copper GBIC speed is 1000Base-T only
Full/Half duplex
Automatic MDI Crossover
Master/Slave relationships
Pause flow control (see flow charts)
Host SERDES Interface:
Differential SERDES Interface at 1.25Gpbs
Master/Slave relationships
SERDES recovers the clock from the received data stream
Pause flow control (see flow charts)
Not Implemented in GBIC Auto-Negotiation:
Next page exchange
Detect remote fault
1000Base-T RJ-45 Gigabit
Ethernet GBIC Copper
Transceiver
1000Base-T RJ-45 Gigabit
Ethernet GBIC Copper
Transceiver
GBIC OPERATIONAL FLOWCHARTS (74740-0001)
Auto-Negotiation
Link Dropout
Main
Routine Start
Yes
LOS GND
Disable SERDES Interface
No
Wait for Copper
Auto-Neg to Complete
Good Copper Link
No
Drop SERDES Link
Yes
Get Copper Auto-Neg Information
Advertise to SERDES
Enable SERDES Interface
No
Wait for SERDES
Auto-Neg to Complete
Yes
Get SERDES Auto-Neg Information
Advertise to Copper
Restart Auto-Neg
No
Wait for
Auto-Neg to Complete
Yes
Return
Restart
Auto-Negotiation
GBIC OPERATIONAL FLOWCHARTS (74740-0002)
Auto-Negotiation
1000Base-T RJ-45 Gigabit
Ethernet GBIC Copper
Transceiver
Link Dropout
Main
Routine Start
Yes
LOS HIGH
Disable SERDES Interface
No
Wait for Copper
Auto-Neg to Complete
Good Copper Link
No
LOS HIGH
Yes
Get SERDES Auto-Neg Information
Advertise to Copper
No
Wait for SERDES
Auto-Neg to Complete
Yes
Get SERDES Auto-Neg Information
Advertise to Copper
Restart Auto-Neg
No
Wait for
Auto-Neg to Complete
Yes
Link is Good
LOS LOW
Return
Drop SERDES Link
Restart
Auto-Negotiation
GBIC OPERATIONAL FLOWCHARTS (74740-0003)
Auto-Negotiation
1000Base-T RJ-45 Gigabit
Ethernet GBIC Copper
Transceiver
Link Dropout
Main
Routine Start
Yes
Good Copper Link
LOS HIGH
No
LOS HIGH
Disable SERDES
No
Wait for Copper
Auto-Neg to Complete
Yes
Get Copper Auto-Neg Information
Advertise to SERDES
Enable SERDES
No
Good Copper Link
Yes
Link is Good
LOS LOW
Return
Restart
Auto-Negotiation
1000Base-T RJ-45 Gigabit
Ethernet GBIC Copper
Transceiver
AUTO-NEGOTIATION SOFTWARE SELECTIONS
Through random I2C read commands, the host can change the auto-negotiation state of the GBIC. When auto-negotiation in the GBIC is
off, the GBIC does not automatically query the host and advertise pause flow control on the copper interface. If the host requires
advertisement of pause flow control and auto-negotiation is off, the host can set pause, and asymmetric pause using the defined I2C
commands. Serial ID addresses 128-133 are used in the random I2C read commands. The read commands, and GBIC actions are defined
in the I2C Command Table.
I2C Command Table
I2C Read Address
Description
128 ( 0x80 )
GBIC Auto-Negotiation Status
129 ( 0x81 )
130 ( 0x82 )
131 ( 0x83 )
132 ( 0x84 )
133 ( 0x85 )
•
Return Status Byte
•
Turn Auto-Negotiation ON
•
Restart Auto-Negotiation
•
Return Status Byte
•
Turn Auto-Negotiation OFF
•
Restart Auto-Negotiation
•
Return Status Byte
•
Clear Pause Flow Control
•
Clear Asymmetric Pause
•
Return Status Byte
SERDES Pause Flow Control Advertisement
•
Set SERDES Pause Flow Control Bit
Enable Auto-Negotiation
Disable Auto-Negotiation
Clear SERDES Pause Flow Control Advertisement
(auto-negotiation off only)
•
Return Status Byte
SERDES Asymmetric Pause Flow Control
Advertisement
•
Set SERDES Asymmetric Pause Flow Control Bit
(auto-negotiation off only)
•
Return Status Byte
GBIC Status Byte
Bit
7
6
5
4
3
2
1
0
GBIC Actions
Description
Reserved
Reserved
Reserved
Copper has Advertised Asymmetric Pause
Copper has Advertised Pause
Host to Advertise Asymmetric Pause on Copper
Host to Advertise Pause on Copper
GBIC Auto Negotiation Status 1 = On / 0 = Off
1000Base-T RJ-45 Gigabit
Ethernet GBIC Copper
Transceiver
ACTIVE PERFORMANCE SPECIFICATIONS
Module Specifications – Recommended Operating Conditions
PARAMETERS
Storage Temperature
Ambient Operating Temperature
SYMBOL
Tstg
Ta
MIN
-40
0
Supply Voltage
Supply Current
Surge Current
V DDR, V DDT
Icc
Isurge
4.75
GBIC Host Serial Interface (TX/RX)
Data Input/Output Type
Impedance (SERDES Interface)
TYP
MAX
85
70
UNITS
ºC
ºC
NOTES
5.25
350
55
Vdc
mA
mA
Vcc-ground
Surge above steady state value
ohms
LVDS, AC coupled
Differential
150
Transm itter (Input to GBIC)
Input Voltage
Receiver (Output to SERDES)
Output Voltage
Max Off Voltage
Rise Time, 20%–80%
Total Jitter
Skew
400
2400
mVpp
875
1525
170
350
192
175
mVpp
mVpp
ps
ps
ps
100
200
msec
85
Link Dropout
74740-0001
From detection of loss of signal to SERDES
disable
Loss of Signal Tim ing
74740-0002, 74740-0003
RX_LOS assert delay
t_loss_on
100
200
msec
RX_LOS negate delay
t_loss_off
3
3.5
sec
From detection of loss of signal to assertion of
RX_LOS
From detection of presence of signal to negation
of RX_LOS
1000Base-T RJ-45 Gigabit
Ethernet GBIC Copper
Transceiver
RELIABILITY PREDICTION REPORT
Temperature: 75°C
Assem bly
Nam e
Part Num ber
Failure Rate
MTBF
1000Base-T
Adapter
Active
Components
Passive
Components
74740-xxxx
0.309435
3,231,693
0.178609
5,598,828
0.130827
7,643,711
IMPEDANCE MATCHING AND POWER SUPPLY FILTERING
Signal inputs/outputs on the GBIC transceiver modules are AC coupled and internally terminated to 75 ohms (TD+, TD-, RD+, RD-). Each
leg of the differential pair was equally matched in length. Figure 2 shows the recommended power supply filtering network.
Figure 2: Recommended Host Board Supply Filtering Network
VccT
VccR
0.1µF
0.1µF
GBIC Module
1.0µH
10µF
1.0µH
0.1µF
10µF
5V
GBIC HOST CONNECTOR PIN DESCRIPTIONS
1000Base-T RJ-45 Gigabit
Ethernet GBIC Copper
Transceiver
PIN
NAME
PIN 1
RX_LOS
DESCRIPTION
Receiver Loss of Signal, logic high, open collector compatible, 4.7 K to 10 K Ohm pull-up to V DDT on
host. See part number chart for details.
PIN 2
RGND
Receiver Ground
PIN 3
RGND
Receiver Ground
PIN 4
MOD_DEF(0)
GBIC module definition and presence, 4.7 K to 10 K Ohm pull-up to V DDT on host
Signal SCL (Clock) of the 2-w ire serial ID interface, 4.7 K to 10 K Ohm pull- up to V DDT on host,
100KHz maximum clock rate.
PIN 5
MOD_DEF(1)
PIN 6
MOD_DEF(2)
PIN 7
TX_DISABLE
Signal SDA (Data) of the 2-w ire serial ID interface, 4.7 K to 10 K Ohm pull- up to V DDT on host
TX_DISABLE is not implemented. Transmitter Disable, logic high, open collector compatible, 4.7 K to
10 K Ohm pull-up to V DDT on GBIC.
PIN 8
TGND
Transmitter Ground
PIN 9
TGND
Transmitter Ground
Transmitter Fault, logic high, open collector compatible, 4.7 K to 10 K Oh pull-up to V DDT on host.
Not implemented on the RJ-45 GBIC
PIN 10
TX_FAULT
PIN 11
RGND
Receiver Ground
PIN 12
RX_DATA (-)
Receive Data, differential AC coupled
PIN 13
RX_DATA (+)
Receive Data, differential AC coupled
PIN 14
RGND
Receiver Ground
PIN 15
V DDR
Receiver Supply +5.0 Volts
PIN 16
V DDT
Transmitter Supply +5.0 Volts
PIN 17
TGND
Transmitter Ground
PIN 18
TX_DATA (+)
Transmit Data, differential AC coupled
PIN 19
TX_DATA (-)
Transmit Data, differential AC coupled
PIN 20
TGND
Transmitter Ground
1000Base-T RJ-45 Gigabit
Ethernet GBIC Copper
Transceiver
1000BASE-T GBIC DIMENSIONS
High Performance Adapter
Headquarters
101 Bringler Drive
Maumelle, AE 72113 USA
501-851-4850
[email protected]
Order No. USA-206
Far East North Headquarters
Yamato, Kanagawa, Japan
81-462-65-2324
[email protected]
Far East South Headquarters
Jurong, Singapore
65-6-268-6868
[email protected]
Printed in USA/0K/AJ/2003.10
European Headquarters
Munich, Germany
49-89-413092-0
[email protected]
Corporate Headquarters
2222 Wellington Ct.
Lisle, Illinois 60532 USA
630-969-4550
©2003, Molex