MA-COM AT

AT-119
2.25 Volt Voltage Variable Absorptive
Attenuator - 40 dB, 1.8—2.5 GHz
Features





Functional Schematic
Single Positive Voltage Control 0 to +2.25 Volts
>50 dB Attenuation Range at 2.1 GHz
Low DC Power Consumption
Low Cost SOT-25 Plastic Package
Tape and Reel Packaging Available
VCC
5
VCTL
4
Description
M/A-COM’s AT-119 is a GaAs MMIC voltage variable
absorptive attenuator in a low cost, SOT-25 five-lead,
surface mount plastic package. M/A-COM fabricates the
AT-119 with a proven monolithic GaAs self-aligned gate
process that features full chip passivation for performance
and reliability
Applications
The AT-119 is ideally suited for applications that require
fine tuning, linear attenuation with voltage, and very low
power consumption.
Typical applications for the AT-119 include automatic gain
control circuits in satellite radio receivers and other wireless
receivers.
1
RF
100 pF
2
GND
3
RF
100 pF
1. VCC = +3.3 VDC @ 50 µA max.
2. VCTL = 0 VDC to +3.3 VDC @ 50 µA max.
3. External DC blocking capacitors are required on all RF
ports.
Absolute Maximum Ratings1
@ TA = +25 °C (unless otherwise specified)
Parameter
Absolute Maximum
Maximum Input Power
+21 dBm
Supply Voltage VCC
-1 V, + 8 V
ControlVoltage VCTL
-1 V, VCC +0.5 V
Operating Temperature
-40°C to +85°C
Storage Temperature
-65°C to +150°C
1. Exceeding any one or a combination of these limits may
cause permanent damage.
Electrical Specifications @ TA = +25 °C, Frequency = 2.4 GHz, VCC = 3.3 VDC1
Parameters
Test Conditions
Units
Min
Minimum Insertions Loss
VCTL = 2.25 VDC
dB
Maximum Attenuation
VCTL = 0.5 VDC
dB
37
Attenuation Slope
0.75 VDC < VCTL < 1.75 VDC
dB/V
24
Typ
Max
3.0
3.2
Return Loss
0.6 VDC < VCTL < 1.75 VDC
dB
>12
Input Power for 1 dB Change in Attenuation
0 VDC < VCTL < 3.0 VDC
dBm
>10
Input 3rd Order Intercept Point
0 VDC < VCTL < 3.0 VDC
dBm
>20
Switching Speed
50% VCTL to 10% / 90% RF
nSec
180
Transients
VCTL = 3 VDC, In-Band
mV
10
1. All measurements in a 50-τ system unless otherwise specified. The RF ports must be blocked outside of the package from
ground or any other voltage.
2.25 Volt Voltage Variable Absorptive Attenuator, 40 dB, 1.8 - 2.5 GHz
AT-119
Typical Performance Curves
Attenuation vs. Frequency @ 0.0 VDC
for Control Voltage
Attenuation vs. Control Voltage, +25 °C
0
0.0
5.0
5
10.0
10
15.0
15
1.8 GHz
20.0
20
25.0
25
30.0
+25 deg C
30
2.4 GHz
35.0
35
40.0
40
45.0
45
50.0
55.0
+85 deg C
50
2.1 GHz
-40 deg C
55
60.0
60
3.0
2.5
2.0
1.5
1.0
0.5
0.0
CONTROL VOLTAGE (Volts)
500
1000
1500
2000
2500
3000
FREQUENCY (MHz)
Insertion Loss vs. Frequency @ 2.25
VDC for Control Voltage
Return Loss vs. Control Voltage
@ +25 °C
0
4.0
3.5
-5
3.0
2.4 GHz
+25 deg C
+85 deg C
2.5
2.1 GHz
-10
-40 deg C
-15
2.0
1.5
-20
1.0
1.8 GHz
-25
0.5
-30
0.0
500
1000
1500
2000
2500
3000
3.0
2.5
FREQUENCY (MHz)
2.0
1.5
1.0
0.5
0.0
CONTROL VOLTAGE (VDC)
Insertion Loss Delta Normalized
to +25 °C
Insertion Loss Delta Normalized
to +25 °C
6
6
o
-40 C
o
+85 C
4
4
1.8 GHz
2
1.8 GHz
2.4 GHz
2
2.4 GHz
0
0
-2
-2
-4
-4
2.1 GHz
2.1 GHz
-6
3.0
-6
2.5
2.0
1.5
1.0
0.5
0.0
CONTROL VOLTAGE (VDC)
3.0
2.5
2.0
1.5
1.0
0.5
0.0
CONTROL VOLTAGE (VDC)
Specifications subject to change without notice.
North America: Tel. (800) 366-2266
Asia/Pacific: Tel.+81-44-844-8296, Fax +81-44-844-8298
Europe: Tel. +44 (1344) 869 595, Fax+44 (1344) 300 020
Visit www.macom.com for additional data sheets and product information.
2
2.25 Volt Voltage Variable Absorptive Attenuator, 40 dB, 1.8 - 2.5 GHz
AT-119
Typical Performance Curves (Cont’d)
Input Power for 1 dB Change in
Attenuation: +25 °C
Input IP3 vs. Control Voltage: +25 °C
20
40
Input Power = 0 dBm
35
2.4
1.8 GHz
15
30
25
10
1.8 GHz
20
15
5
2.4 GHz
10
5
0
0
3.0
2.5
2.0
1.5
1.0
0.5
0.0
3
2.5
2
1.5
1
0.5
0
CONTROL VOLTAGE (VDC)
CONTROL VOLTAGE (VDC)
Typical Device Variation,
Attenuation vs. VCTL
0
5
Freq = 2.4 GHz
10
15
20
25
30
35
40
45
50
55
60
3.0
2.5
2.0
1.5
1.0
0.5
0.0
VCTL (VDC)
Specifications subject to change without notice.
North America: Tel. (800) 366-2266
Asia/Pacific: Tel.+81-44-844-8296, Fax +81-44-844-8298
Europe: Tel. +44 (1344) 869 595, Fax+44 (1344) 300 020
Visit www.macom.com for additional data sheets and product information.
3
2.25 Volt Voltage Variable Absorptive Attenuator, 40 dB, 1.8 - 2.5 GHz
SOT-25 1
SOT-25 1 Dimensions
DIM
D
PIN 5
Measurement (mm)
MIN
A2
e1
WZ X Y
E1
AT-119
E
L
PIN 5
e
c
°
A1
A
b
1. See JEDEC MO-178 VAR AA for additional dimensions and
tolerances
NOM
MAX
A
1.45
A1
0.15
A2
0.90
1.15
b
0.30
0.50
c
0.08
0.22
D
2.90 basic
e
0.95 basic
e1
1.90 basic
E
2.80 basic
E1
1.60 basic
1.30
L
0.30
0.60
0.45
°
0°
4°
8°
Ordering Information
Part Number
Package
AT-119TR
Tape and Reel1
AT-119TR-3000
3000 Piece Tape and Reel
AT-119SMB
Sample Board
1. If specific reel size is required, consult factory for part
number assignment.
Specifications subject to change without notice.
North America: Tel. (800) 366-2266
Asia/Pacific: Tel.+81-44-844-8296, Fax +81-44-844-8298
Europe: Tel. +44 (1344) 869 595, Fax+44 (1344) 300 020
Visit www.macom.com for additional data sheets and product information.
4