POWER-SYSTEMS CXA-0271

DC-AC INVERTER UNIT
(PRELIMINARY INFORMATION)
CXA-0271 (6W DOUBLE OUTPUT WITH DIMMING FUNCTION)
DESCRIPTION :
This DC to AC Inverter was developed for many other low LCD
Backlight power supply as low profile applications, either for LCD
Monitor or Industrial PC.
APPLICABLE LCD:
10 to 15 inches double lamp type
Lamp Voltage
460V
Lamp Current
6mA
Lamp Start Up Voltage 1500Vrms (Vin : 12V)
CXA-0271
Lot.9517
MADE IN JAPAN
FEATURES :
PWM dimming circuit
Current Feedback Circuit
High Efficiency
Low noise with voltage resonant circuit
Regulated output current
TEMPERATURE & HUMDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
0 °C ~ +60°C
-30 °C ~ +85°C
95 %RH max
DIMENSIONS :
(0.8)
66.5 ± 0.3
66.5 ± 0.3
5-ø3.0 ± 0.2
3
1
Unit : mm
Weight : 21.0 (g) typ.
1
5
CN1
CXA-0271
Lot.9517
MADE IN
JAPAN
3
30 ± 0.5
1
(4)
CAUTION
HIGH VOLTAGE
CAUTION
HIGH VOLTAGE
T1
3.5 ± 0.35
CN3
CN2
18 ± 0.2
3
8.5 ± 0.35
140 ± 0.5
70 ± 0.5
52.5 ± 0.3
52.5 ± 0.3
3
1
2
8MAX
No.
1
2
3
Part Discription
PCB
Connector CN1
Connector CN2
Qty.
1
1
2
Material
UL94V-0 (CEM-3)
S5B-PH-SM3
SM02(8.0)B-BHS-1
Note
t=1mm
JST
JST
Power Systems – The Power Solution
Web:
Emai:
www.Power-Systems.de
[email protected]
All specification are subject to change without notice.
Page ( 1 / 4 )
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 80
VER, 01 October 2003
DC-AC INVERTER UNIT
(PRELIMINARY INFORMATION)
CXA-0271 (6W DOUBLE OUTPUT WITH DIMMING FUNCTION)
Input Side CN1:
Output Side CN2:
Pin No. Symbols
Ratings
Vin
10.8~13.2V
CN 1-1
GND
0V
CN 1-2
Vbr
0~2.5V
CN 1-3
Vst
0/5V
CN 1-4
0~13.2V:
Vrmt
0~0.4V OFF /
CN 1-5
2~13.2V ON
Output Side CN3:
Pin No. Symbols Ratings
VHIGH1 460 Vrms
CN 2-1
N.C.
CN 2-2
VLOW1
(5V)
CN 2-3
Pin No. Symbols Ratings
VHIGH2 460 Vrms
CN 3-1
N.C.
CN 3-2
VLOW2
(5V)
CN 3-3
ELECTRICAL CHARACTERISTICS :
Conditions
Items
Output
Current
Input
Current
Symbols
Iout1/2
Vin (V) Vrmt (V) Vbr (V) Ta (°C) RL1 / RL2 (KΩ ) Min. Typ. Max.
12±0.1
12±1.2
Iin1
12±1.2
Iin2
F1
12±1.2
Frequency
F2 (Duty)
Open
Circuit
Vopen 12±1.2
Voltage
Dimming
Iout1/2 12±0.1
Function
Warning
Signal
Vst
Specification
12±0.1
5±0.25
0
23±5
0~60
74±0.5
5±0.25
0~0.4
0~1.5
23±5
74±0.5
5±0.25
0
1.0±0.05
23±5
74±0.5
5±0.25
0
23±5
∞
5±0.25
2.5±0.05
23±5
74±0.5
23±5
RL1=74, RL2=∞
RL1=∞ , RL2=74
RL1=∞ , RL2=∞
RL1=74, RL2=74
5±0.25
0~2.5
5.7
5
38
254
6
6
550
43
305
1250 1500
Unit
6.7
7
700
1
48
356
mA DC
-
Vrms
mArms
1.2
2
2.8
4.5
5
5.5
-
-
0.5
mArms
kHz
Hz
VDC
DIMMING CHARACTERISTICS
(Reference):
7
Iout (mArms)
6
5
4
3
2
1
0
0
1,25
2,5
Vbr (VDC)
Power Systems – The Power Solution
Web:
Emai:
www.Power-Systems.de
[email protected]
All specification are subject to change without notice.
Page ( 2 / 4 )
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 80
VER, 01 October 2003
DC-AC INVERTER UNIT
(PRELIMINARY INFORMATION)
CXA-0271 (6W DOUBLE OUTPUT WITH DIMMING FUNCTION)
APPLICATION (for example)
Voltage Dimming Type
F
F1
Iin
Vin 10.8~
13.2V
Vin
A
-
CN1-1
(Vin)
V
-
0~ Vrmt
2.5V
V
-
1000:1
F2
CN2-1
(VHIGH1)
C7
Vst
V
-
V
Vbr
CN1-2
(GND)
Q6
CN3-1
(VHIGH2)
RL2
C8
CN1-3
(Vbr)
0/5V
A
a
Iout
1
Vopen
CN3-3
(VLOW2)
CN1-5
(Vrmt)
S
W
V
A
Iout
2
Q7
CN1-4
(Vst)
b
RL1
CN2-3
(VLOW1)
TEST CIRCUIT:
1000:1
PROBE
F
F1
Iin
Vin
10.8~13.2V
Vin
A
CN1-1
CN2-1
C10
V
CN1-2
0/5V
0~
2.5V
F2
CN3-1
Q6
V
V
CN1-3
CN1-4
V
Vst
RL1
RL2
Vrmt Vbr
CN1-5
Q7
CN3-3
Io2
A
~
Io1
A
~
V
~
Vopen
CN2-3
Power Systems – The Power Solution
Web:
Emai:
www.Power-Systems.de
[email protected]
All specification are subject to change without notice.
Page ( 3 / 4 )
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 80
VER, 01 October 2003
DC-AC INVERTER UNIT
CXA-0271 (6W DOUBLE OUTPUT WITH DIMMING FUNCTION)
(PRELIMINARY INFORMATION)
Note 1.
For circuit connection, please prefer to test circuit diagram.
Note 2.
Please use minimum of 2mm clearance (all directions) between inverter high voltage area and any
conductors. Please refer to mechanical drawing for marking of high voltage area.
Note 3.
Open voltage (strike voltage) is measured across the transformer secondary winding at no load as the
reading at the output connector would be less than the actual value.
Note 4.
If the start voltage falls below Cold Cathode Tube strike voltage, the CCFL will not light up easily
specially at lower ambient temperature. Please review mounting instruction to avoid any abnormal
operation due to coupling/leakage capacitance of inverter high voltage area to any surrounding
conductor.
Note 5.
Please check your lamp characteristic for minimum operational current and set the limit point in your
design to avoid flickering and/or abnormal operation.
Note 6.
For proper operation of circuit protection (FUSE or IC PROTECTOR), please use minimum of 2A
capacity for input power supply.
Note 7.
The warning signal: 5V in abnormal circumstances.
Note 8.
The brightness of the lamp changes at the change and this level, too, when the direction cjanges the
input voltage lower than 12V of the standard.
Note 10.
In test circuit, if one of the switches CN2 or CN3 opens, then the warning signal will be activated (+5V).
Power Systems – The Power Solution
Web:
Emai:
www.Power-Systems.de
[email protected]
All specification are subject to change without notice.
Page ( 4 / 4 )
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 80
VER, 01 October 2003