DC-AC INVERTER UNIT PS-M06D12S3-NJ4L-016 (6,5 W DUAL OUTPUTS) (PRELIMINARY INFORMATION) DESCRIPTION : This low profile DC to AC Inverter is developed for dual lamps. Optimized for Sharp: LQ084S3DG01. APPLICABLE LCD: 6.4 to 12 inches double lamp type Lamp Voltage 435 Vrms Lamp Current 6 mArms Lamp Start Up Voltage 1.200 Vrms (Vin : 12 Vdc) FEATURES : Remote ON/OFF Options: - Ext. PWM-Dimming Function (order code: PS-M06D12S3-EJ4L-016) TEMPERATURE & HUMDITY : Operating Temperature Range Storage Temperature Range Humidity 0°C ~ +60°C -20°C ~ +85°C 95 %RH max DIMENSIONS : 13 ± 0.5 PS-MXXDXX-NJX 29/01/2004 MADE IN GERMANY CN1-1 CN2 82 ± 0.3 CN1 15 ± 0.3 22,5 ± 0.5 5 ± 0.5 105 ± 0.5 (2) CAUTION HIGH VOLTAGE CN2-1 CN1-5 10.0MAX CN2-4 3 2 - Ø2.5 ± 0.2 (for M2 screws) 2 (2) 1 Unit : mm Weight :20 (g) typ. High Voltage generation area 60mm Note: Please use plastic screw in case of a non-insulating mounting base! Components No. 1 2 3 Part Discription PCB Connector CN1 Connector CN2 Input side CN1: Pin No. Symbols Vin CN 1-1 GND CN 1-2 CN 1-3 Ext. PWM N.C. CN 1-4 CN 1-5 Vrm t Qty. 1 1 1 Material UL94V-0 (FR-4 or CEM-3) S5B-PH-SM3 SM03(4.0)B-BHS Note t=1.6m m JST or equal JST or equal Output side CN2: Pin No. Symbols Ratings Vhigh 435 Vrm s (6 m Arm s ) CN 2-1+2 N.C. CN 2-3 Vlow 0 Vdc (Option -1: 2,0 Vdc) CN 2-4 Ratings 12 Vdc 0 ~ 5 Vdc (L activ) 0 / 5 Vdc (H activ) Power Systems – The Power Solution Web: Email: www.Power-Systems.de [email protected] All specification are subject to change without notice. Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 80 Page (1) VER 29. Sep 2004 DC-AC INVERTER UNIT PS-M06D12S3-NJ4L-016 (6,5 W DUAL OUTPUTS) (PRELIMINARY INFORMATION) ELECTRICAL CHARACTERISTICS : Conditions Vrmt Vin (V) Tu (°C) (V) Iout1+2 12±0.12 5±0.25 0 ~ +60 Iout1+2 12±1.2 5±0.25 0 ~ +60 Iin 12±1.2 5±0.25 0 ~ +60 F 12±1.2 5±0.25 0 ~ +60 Vopen 11,4 5±0.25 0 ~ +60 Parameters Output Current Output Current Input Current Frequency Open Circuit Voltage Note 1 : Min. Typ. Max. 5.5 5.0 45 1.200 6.0 6.0 0.7 55 - 6.5 7.0 1.2 65 - Unit Note m Arm s m Arm s Adc kHz Vrm s Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked on mechanical drawing and any conductors. TEST CIRCUIT : Vin 12 V Specification Symbols A F Iin 1000:1 PROBE F CN1-1 Vopen V ~ SW 1 SW3 V CN2-1 CN1-2 Operation of unit a Operation b Non operation SW4 CN1-3 T1 CN2-2 RL2 Ext. PWM* 0~5V NC A Iout ~ CN1-4 2 Vrmt 2.5 Vdc ~ Vin RL1 CL2 SW5 a V b Iout1 CL1 A ~ CN2-4 SW1 CN1-5 *) Only active when Vrmt is 0 Vdc or floating External PWM-Dimming / Remote ON / OFF Detailed Circuit Diagram : Power Systems – The Power Solution Web: Email: www.Power-Systems.de [email protected] All specification are subject to change without notice. Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 80 Page (2) VER 29. Sep 2004