VISHAY 15STH06FP

New Product
15STH06FP
Vishay High Power Products
Hyperfast Rectifier,
15 A FRED PtTM
FEATURES
• Hyperfast recovery time
RoHS
• Low forward voltage drop
COMPLIANT
• Low leakage current
• 175 °C operating junction temperature
1
• Designed and qualified for industrial level
3
2
DESCRIPTION
15STH06FP 600 V series are the state of the art
tandem hyperfast recovery rectifiers: excellent switching
performance and extremely low forward voltage drop trade
off is overcome, boosting overall application performance.
Specially designed for CCM PFC application, these devices
show incomparable performance in every current intensive
hard switching application.
Optimized reverse recovery stored charge enables
downsizing of boosting switch and cooling system, increased
operating frequency make possible use of smaller reactive
elements. Cost effective PFC application is then possible
with high efficiency over wide input voltage range and
loading factor.
Plastic insulated package features easy mounting together
with not insulated parts.
3L TO-220 FULL-PAK
PRODUCT SUMMARY
trr
20 ns
IF(AV)
15 A
VR
600 V
ABSOLUTE MAXIMUM RATINGS FOR BOTH DIODES
PARAMETER
SYMBOL
Repetitive peak reverse voltage
TEST CONDITIONS
VRRM
DC forward current
Non-repetitive peak surge current
Operating junction and storage temperatures
MAX.
UNITS
600
V
IF
TC = 73 °C
15
IFSM
TC = 25 °C
115
TJ, TStg
A
- 55 to 175
°C
ELECTRICAL SPECIFICATIONS FOR BOTH DIODES (TJ = 25 °C unless otherwise specified)
PARAMETER
Breakdown voltage,
blocking voltage
Forward voltage
SYMBOL
VBR,
VR
VF
TEST CONDITIONS
MIN.
TYP.
MAX.
600
-
-
IF = 15 A
-
2.2
2.4
IF = 15 A, TJ = 125 °C
-
1.9
2.1
IF = 15 A, TJ = 150 °C
-
1.8
2
IR = 100 µA
VR = VR rated
-
<1
10
Reverse leakage current
IR
TJ = 125 °C, VR = VR rated
-
10
100
TJ = 150 °C, VR = VR rated
-
40
200
Junction capacitance
CT
VR = 600 V
-
17
-
Document Number: 94556
Revision: 07-Apr-08
For technical questions, contact: [email protected]
UNITS
V
µA
pF
www.vishay.com
1
New Product
15STH06FP
Vishay High Power Products
Hyperfast Rectifier,
15 A FRED PtTM
DYNAMIC RECOVERY CHARACTERISTICS FOR BOTH DIODES (TJ = 25 °C unless otherwise specified)
PARAMETER
SYMBOL
TEST CONDITIONS
MIN.
TYP.
MAX.
UNITS
IF = 1.0 A, dIF/dt = - 50 A/µs, VR = 30 V
-
-
28
TJ = 25 °C
-
20
-
-
45
-
-
2.6
-
-
5.6
6.5
TJ = 25 °C
-
28
-
TJ = 125 °C
-
140
-
MIN.
TYP.
MAX.
UNITS
TJ, TStg
- 55
-
175
°C
Thermal resistance,
junction to case
RthJC
-
-
3.9
Thermal resistance,
case to heatsink
RthCS
-
0.2
-
-
2.0
-
g
-
0.07
-
oz.
6.0
(5.0)
-
12
(10)
kgf · cm
(lbf · in)
Reverse recovery time
trr
TJ = 125 °C
Peak recovery current
Reverse recovery charge
IRRM
Qrr
TJ = 25 °C
TJ = 125 °C
IF = 15 A
dIF/dt = - 200 A/µs
VR = 390 V
ns
A
nC
THERMAL - MECHANICAL SPECIFICATIONS FOR BOTH DIODES
PARAMETER
Maximum junction and
storage temperature range
SYMBOL
TEST CONDITIONS
Mounting surface, flat, smooth
and greased
Weight
Mounting torque
Marking device
www.vishay.com
2
°C/W
Case style 3L TO-220 FULL-PAK
For technical questions, contact: [email protected]
15STH06FP
Document Number: 94556
Revision: 07-Apr-08
New Product
15STH06FP
Hyperfast Rectifier,
15 A FRED PtTM
Vishay High Power Products
1000
Reverse Current - I R (μA)
175°C
100
150°C
10
125°C
1
100°C
0.1
25°C
0.01
0.001
0
100
200
300
400
500
600
Reverse Voltage - VR (V)
10
Fig. 2 - Typical Values of Reverse Current vs.
Reverse Voltage
1000
Junction Capacitance - C T (pF)
Instantaneous Forward Current - I F (A)
100
Tj = 175°C
Tj = 150°C
Tj = 125°C
Tj = 25°C
1
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
100
10
1
0
Forward Voltage Drop - VFM (V)
100
200
300
400
500
600
Reverse Voltage - VR (V)
Fig. 1 - Maximum Forward Voltage Drop Characteristics
Fig. 3 - Typical Junction Capacitance vs. Reverse Voltage
Thermal Impedance Z thJC (°C/W)
10
D = 0.5
1
D = 0.2
D = 0.1
D = 0.05
0.1
D = 0.02
D = 0.01
Single Pulse
(Thermal Resistance)
0.01
1E-05
1E-04
1E-03
1E-02
1E-01
1E+00
1E+01
1E+02
1E+03
t1, Rectangular Pulse Duration (Seconds)
Fig. 4 - Maximum Thermal Impedance ZthJC Characteristics
Document Number: 94556
Revision: 07-Apr-08
For technical questions, contact: [email protected]
www.vishay.com
3
New Product
15STH06FP
Hyperfast Rectifier,
15 A FRED PtTM
Vishay High Power Products
45
40
Average Power Loss ( Watts )
Allowable Case Temperature (°C)
200
150
DC
100
50
35
RMS Limit
30
D = 0.01
D = 0.02
D = 0.05
D = 0.1
D = 0.2
D = 0.5
25
20
15
10
DC
5
0
0
0
2
4
6
8
10 12 14 16
0
5
10
15
20
25
Average Forward Current - IF(AV) (A)
Fig. 6 - Forward Power Loss Characteristics
Average Forward Current - IF(AV)(A)
Fig. 5 - Maximum Allowable Case Temperature vs.
Average Forward Current
100
1000
Vr = 390V
Vr = 390V
If = 15A, 125°C
trr ( ns )
Qrr ( nC )
If = 15A, 125°C
100
If = 15A, 25°C
If = 15A, 25°C
10
10
100
1000
100
1000
di F /dt (A/μs )
di F /dt (A/μs )
Fig. 7 - Typical Reverse Recovery Time vs. dIF/dt
Fig. 8 - Typical Stored Charge vs. dIF/dt
LINKS TO RELATED DOCUMENTS
Dimensions
http://www.vishay.com/doc?95264
Part marking information
http://www.vishay.com/doc?95266
www.vishay.com
4
For technical questions, contact: [email protected]
Document Number: 94556
Revision: 07-Apr-08
Legal Disclaimer Notice
Vishay
Disclaimer
All product specifications and data are subject to change without notice.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf
(collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein
or in any other disclosure relating to any product.
Vishay disclaims any and all liability arising out of the use or application of any product described herein or of any
information provided herein to the maximum extent permitted by law. The product specifications do not expand or
otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed
therein, which apply to these products.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this
document or by any conduct of Vishay.
The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications unless
otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such
applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting
from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding
products designed for such applications.
Product names and markings noted herein may be trademarks of their respective owners.
Document Number: 91000
Revision: 18-Jul-08
www.vishay.com
1