New Product 15STH06FP Vishay High Power Products Hyperfast Rectifier, 15 A FRED PtTM FEATURES • Hyperfast recovery time RoHS • Low forward voltage drop COMPLIANT • Low leakage current • 175 °C operating junction temperature 1 • Designed and qualified for industrial level 3 2 DESCRIPTION 15STH06FP 600 V series are the state of the art tandem hyperfast recovery rectifiers: excellent switching performance and extremely low forward voltage drop trade off is overcome, boosting overall application performance. Specially designed for CCM PFC application, these devices show incomparable performance in every current intensive hard switching application. Optimized reverse recovery stored charge enables downsizing of boosting switch and cooling system, increased operating frequency make possible use of smaller reactive elements. Cost effective PFC application is then possible with high efficiency over wide input voltage range and loading factor. Plastic insulated package features easy mounting together with not insulated parts. 3L TO-220 FULL-PAK PRODUCT SUMMARY trr 20 ns IF(AV) 15 A VR 600 V ABSOLUTE MAXIMUM RATINGS FOR BOTH DIODES PARAMETER SYMBOL Repetitive peak reverse voltage TEST CONDITIONS VRRM DC forward current Non-repetitive peak surge current Operating junction and storage temperatures MAX. UNITS 600 V IF TC = 73 °C 15 IFSM TC = 25 °C 115 TJ, TStg A - 55 to 175 °C ELECTRICAL SPECIFICATIONS FOR BOTH DIODES (TJ = 25 °C unless otherwise specified) PARAMETER Breakdown voltage, blocking voltage Forward voltage SYMBOL VBR, VR VF TEST CONDITIONS MIN. TYP. MAX. 600 - - IF = 15 A - 2.2 2.4 IF = 15 A, TJ = 125 °C - 1.9 2.1 IF = 15 A, TJ = 150 °C - 1.8 2 IR = 100 µA VR = VR rated - <1 10 Reverse leakage current IR TJ = 125 °C, VR = VR rated - 10 100 TJ = 150 °C, VR = VR rated - 40 200 Junction capacitance CT VR = 600 V - 17 - Document Number: 94556 Revision: 07-Apr-08 For technical questions, contact: [email protected] UNITS V µA pF www.vishay.com 1 New Product 15STH06FP Vishay High Power Products Hyperfast Rectifier, 15 A FRED PtTM DYNAMIC RECOVERY CHARACTERISTICS FOR BOTH DIODES (TJ = 25 °C unless otherwise specified) PARAMETER SYMBOL TEST CONDITIONS MIN. TYP. MAX. UNITS IF = 1.0 A, dIF/dt = - 50 A/µs, VR = 30 V - - 28 TJ = 25 °C - 20 - - 45 - - 2.6 - - 5.6 6.5 TJ = 25 °C - 28 - TJ = 125 °C - 140 - MIN. TYP. MAX. UNITS TJ, TStg - 55 - 175 °C Thermal resistance, junction to case RthJC - - 3.9 Thermal resistance, case to heatsink RthCS - 0.2 - - 2.0 - g - 0.07 - oz. 6.0 (5.0) - 12 (10) kgf · cm (lbf · in) Reverse recovery time trr TJ = 125 °C Peak recovery current Reverse recovery charge IRRM Qrr TJ = 25 °C TJ = 125 °C IF = 15 A dIF/dt = - 200 A/µs VR = 390 V ns A nC THERMAL - MECHANICAL SPECIFICATIONS FOR BOTH DIODES PARAMETER Maximum junction and storage temperature range SYMBOL TEST CONDITIONS Mounting surface, flat, smooth and greased Weight Mounting torque Marking device www.vishay.com 2 °C/W Case style 3L TO-220 FULL-PAK For technical questions, contact: [email protected] 15STH06FP Document Number: 94556 Revision: 07-Apr-08 New Product 15STH06FP Hyperfast Rectifier, 15 A FRED PtTM Vishay High Power Products 1000 Reverse Current - I R (μA) 175°C 100 150°C 10 125°C 1 100°C 0.1 25°C 0.01 0.001 0 100 200 300 400 500 600 Reverse Voltage - VR (V) 10 Fig. 2 - Typical Values of Reverse Current vs. Reverse Voltage 1000 Junction Capacitance - C T (pF) Instantaneous Forward Current - I F (A) 100 Tj = 175°C Tj = 150°C Tj = 125°C Tj = 25°C 1 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 100 10 1 0 Forward Voltage Drop - VFM (V) 100 200 300 400 500 600 Reverse Voltage - VR (V) Fig. 1 - Maximum Forward Voltage Drop Characteristics Fig. 3 - Typical Junction Capacitance vs. Reverse Voltage Thermal Impedance Z thJC (°C/W) 10 D = 0.5 1 D = 0.2 D = 0.1 D = 0.05 0.1 D = 0.02 D = 0.01 Single Pulse (Thermal Resistance) 0.01 1E-05 1E-04 1E-03 1E-02 1E-01 1E+00 1E+01 1E+02 1E+03 t1, Rectangular Pulse Duration (Seconds) Fig. 4 - Maximum Thermal Impedance ZthJC Characteristics Document Number: 94556 Revision: 07-Apr-08 For technical questions, contact: [email protected] www.vishay.com 3 New Product 15STH06FP Hyperfast Rectifier, 15 A FRED PtTM Vishay High Power Products 45 40 Average Power Loss ( Watts ) Allowable Case Temperature (°C) 200 150 DC 100 50 35 RMS Limit 30 D = 0.01 D = 0.02 D = 0.05 D = 0.1 D = 0.2 D = 0.5 25 20 15 10 DC 5 0 0 0 2 4 6 8 10 12 14 16 0 5 10 15 20 25 Average Forward Current - IF(AV) (A) Fig. 6 - Forward Power Loss Characteristics Average Forward Current - IF(AV)(A) Fig. 5 - Maximum Allowable Case Temperature vs. Average Forward Current 100 1000 Vr = 390V Vr = 390V If = 15A, 125°C trr ( ns ) Qrr ( nC ) If = 15A, 125°C 100 If = 15A, 25°C If = 15A, 25°C 10 10 100 1000 100 1000 di F /dt (A/μs ) di F /dt (A/μs ) Fig. 7 - Typical Reverse Recovery Time vs. dIF/dt Fig. 8 - Typical Stored Charge vs. dIF/dt LINKS TO RELATED DOCUMENTS Dimensions http://www.vishay.com/doc?95264 Part marking information http://www.vishay.com/doc?95266 www.vishay.com 4 For technical questions, contact: [email protected] Document Number: 94556 Revision: 07-Apr-08 Legal Disclaimer Notice Vishay Disclaimer All product specifications and data are subject to change without notice. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein or in any other disclosure relating to any product. Vishay disclaims any and all liability arising out of the use or application of any product described herein or of any information provided herein to the maximum extent permitted by law. The product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein, which apply to these products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications unless otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. Product names and markings noted herein may be trademarks of their respective owners. Document Number: 91000 Revision: 18-Jul-08 www.vishay.com 1