MA-COM FN61

High Performance, Low Loss Coaxial Cable
FN61
V1
Data for FN61 cable
Electrical:
Frequency Range:
Insertion Loss:
Power Handling:
Impedance:
Velocity of Propagation:
Time delay:
Capacitance:
DC to 8 GHz theoretical
Assemblies are offered to 8 GHz*
See sheet 3 (IL @ 1 GHz is 3.134 dB/100 ft)
See sheet 3
50 Ohms Nominal
76 percent nominal
1.337 nanoseconds/foot nominal
(4.386 nanoseconds/meter nominal)
26.8 picoFarads/foot nominal
(87.9 picoFarads/meter nominal)
Mechanical:
Construction Details:
Dimensions:
Minimum Bend Radius:
Flexure:
Weight:
Maximum Assembly Length:
Available in Bulk:
See sheet 2
See sheet 2
1.83 inches (46.48mm) Static
3.05 inches (77.47mm) Dynamic
>100,000 cycles per MIL-C-87104
0.3100 lb/ft (461.74 g/m) nominal
Approximately 1000 feet (304.8 m)
No
Environmental:
Temperature:
-55°C to 200°C
* Upper frequency limit of assemblies may be restricted by the connector types selected
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
FN61
V1
High Performance, Low Loss Coaxial Cable
Construction Details for FN-- Cable
Stranded, silver plated copper
Diamond braided, flat silver plated copper
Extruded FEP
Nomex
Adhesive Kapton
Diamond braided, round silver plated copper
Metalized Kapton interlayer
Air-Spaced Teflon tapes
Dimensions for FN61 Cable
0.177 ± 0.002
0.515 ± 0.004
0.581 ± 0.006
0.61 Nominal
0.550 ± 0.006
0.503 ± 0.003
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
FN61
V1
High Performance, Low Loss Coaxial Cable
Maximum Insertion Loss for FN61 Cable
dB/100 feet
10
9
8
7
6
5
4
3
2
1
00
1
2
Altitude: Any
Ambient Temperature: 25°C
3
4
5
6
Frequency (GHz)
7
8
Maximum Power Handling (KiloWatts CW) for FN61 cable
18
16
14
12
10
8
6
Maximum
Recommended
4
2
0
0.8
Altitude: Sea Level
Ambient Temperature: 25°C
Load VSWR: Unity
4.4
8
Frequency (GHz)
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.