PROTEC 30KPA36A

05113
30KPA30A - 30KPA360A
Only One Name Means ProTek’Tion™
30kW power tvs component
Description
The 30KPA Series, are discrete 30,000 Watt, silicon transient voltage suppressors (TVS) designed for use in applications
where large voltage transients can permanently damage voltage sensitive components and equipment.
The 30KPA series is available in voltages ranging from 30V to 360V with 5 percent and 10 percent tolerances. Both
tolerances are referenced to the power supply output or operating voltage level. This series is compatible with IEC
61000-4-5 (Surge) requirements.
AXIAL LEAD package
Features
applications
• Compatible with IEC 61000-4-5 (Surge): 48A, 8/20µs - L3(LineGround), L4(Line-Line) & L1 (Power)
• 30,000 Watts Peak Pulse Power per Line (tp = 10/1000µs)
• Unidirectional and Bidirectional Configurations
• Easy Mounting to Printed Circuit Board
• tClamping (0V to VBR Min.) < 1 x 10-12 seconds theoretical (Unidirectional) and < 5ns (Bidirectional)
• Available in Multiple Voltages Ranging From 30V to 360V
• RoHS Complaint (Exemption #7)
• Relay Drives
• Motor (Start/Stop) Back EMF Protection
• Module Lightning Protection
• Secondary Lightning Protection for AC/DC
mechanical characteristics
• Molded Case
• Approximate Weight: 5 grams
• Lead-Free Pure-Tin Plating (Annealed)
• Solder Reflow Temperature:
Pure-Tin - Sn, 100: 260-270°C
• Flammability Rating UL 94V-0
CIRCUIT DIAGRAMS
UNIDIRECTIONAL
05113.R23 3/11
BIDIRECTIONAL
Page 1
www.protekdevices.com
05113
30KPA30A - 30KPA360A
Only One Name Means ProTek’Tion™
typical device characteristics
MAXIMUM RATINGS @ 25°C Unless Otherwise Specified
PARAMETER
Peak Pulse Power (tp = 10/1000µs) - See Figure 1
SYMBOL
VALUE
UNITS
PPP
30,000
Watts
Forward Surge Rating - 1/120 seconds - See Note 2
IF
200
Amps
Steady State Power Dissipation
PP
8.0
Watts
Storage Temperature
TSTG
-55 to 150
°C
TL
-55 to 150
°C
Operating Temperature
ELECTRICAL CHARACTERISTICS PER LINE @ 25°C Unless Otherwise Specified
PART
NUMBER
(Notes 1 - 2)
RATED
STAND-OFF
VOLTAGE
VWM
VOLTS
BREAKDOWN
VOLTAGE
MIN
V(BR)
VOLTS
MAXIMUM
LEAKAGE
CURRENT
@I T
mA
@V WM
ID
µA
MAXIMUM
CLAMPING
VOLTAGE
(Fig. 2)
temperature
coefficient
of v(br)
@ 10/1000µs
VC @ I PP
qV(BR)
mV/°C
30KPA30A
30.0
33.3
50
5000
55.2V @ 543.0A
34
30KPA33A
33.0
36.7
50
5000
58.6V @ 512.0A
39
30KPA36A
36.0
40.0
50
2000
61.8V @ 485.0A
41
30KPA43A
43.0
47.8
50
1000
73.0V @ 410.0A
50
30KPA48A
48.0
53.3
5
250
77.4V @ 388.0A
56
30KPA58A
58.0
64.4
5
20
92.4V @ 325.0A
68
30KPA64A
64.0
71.1
5
10
104.0V @ 294.0A
76
30KPA70A
70.0
77.8
5
10
109.0V @ 274.0A
83
30KPA75A
75.0
83.3
5
10
119.4V @ 251.0A
89
30KPA85A
85.0
94.4
5
10
139.0V @ 216.0A
105
30KPA90A
90.0
100.0
5
10
147.0V @ 206.0A
109
30KPA100
100.0
111.0
5
10
179.0V @ 168.0A
134
30KPA100A
100.0
111.0
5
10
162.0V @ 186.0A
121
30KPA130A
130.0
144.0
5
10
209.0V @ 142.0A
157
30KPA160A
160.0
178.0
5
10
252.6V @ 119.0A
195
30KPA170A
170.0
189.0
5
10
274.0V @ 110.0A
207
30KPA180A
180.0
200.0
5
10
291.0V @ 104.0A
230
30KPA220A
220.0
245.0
5
10
356.0V @ 84.0A
269
30KPA250A
250.0
277.0
5
10
404.0V @ 74.0A
314
30KPA260A
260.0
289.0
5
10
416.0V @ 72.0A
317
30KPA280A
280.0
311.0
5
10
464.0V @ 65.0A
342
30KPA300A
300.0
334.0
5
10
484.0V @ 62.0A
368
30KPA320A
320.0
356.0
5
10
530.0V @ 57.0A
370
30KPA360A
360.0
400.0
5
10
640.0V @ 55.0A
380
notes
1. Part numbers shown are unidirectional devices. Add a “CA” suffix to specify bidirectional devices, such as 30KPA30CA.
2. VF = 15 Volts @ 200A, 8.3ms(1/2 Sine Wave) - Unidirectional devices only.
05113.R23 3/11
Page 2
www.protekdevices.com
05113
30KPA30A - 30KPA360A
Only One Name Means ProTek’Tion™
typical device characteristics
figure 1
peak pulse power vs pulse time
PPP - Peak Pulse Power - kilowatts
1,000
100
30kW, 10/1000µs
Waveform
10
1
0.1
1
10
100
td - Pulse Duration - µs
1,000
10,000
figure 3
POWER DERATING CURVE
figure 2
PULSE WAVEFORM
100
tf
TEST
WAVEFORM
PARAMETERS
tf = 10µs
td = 1000µs
100
Peak Value IPP
Peak Pulse Power
10/1000µs
80
% Of Rated Power
IPP - Peak Pulse Current - % of IPP
100,000
td = t/(IPP/2)
50
60
40
20
e
0
0
-t
1
2
0
3
25
50
75
100
125
150
TL - Lead Temperature - °C
t - Time - ms
05113.R23 3/11
0
Page 3
www.protekdevices.com
05113
30KPA30A - 30KPA360A
Only One Name Means ProTek’Tion™
axial LEAD package information
outline dimensions
millimeters
dim
inches
min
max
min
max
A
24.5
-
1.00
-
B
8.60
9.10
0.34
0.36
C
24.5
-
1.00
-
D
1.20 DIA.
1.30 DIA.
0.048 DIA.
0.052 DIA.
E
8.60
9.10
0.34
0.36
A
E
Notes
1. Dimensions are exclusive of mold flash and metal burrs.
B
C
D
ORDERING INFORMATION
base PART NUMBER
(xx = Voltage)
LEADFREE SUFFIX
TAPE SUFFIX
QTY/REEL
REEL SIZE
TUBE qty
30KPAxx
-LF
n/a
n/a
n/a
n/a
30KPAxxA
-LF
n/a
n/a
n/a
n/a
30KPAxxCA
-LF
n/a
n/a
n/a
n/a
Notes
MARKING DIAGRAM
1. Marking on Part - logo, part number, date code and positive terminal marked with
band(unidirectional only).
P
yyww
30KPAxxx
Package outline per document number 06028.R2 9/09.
05113.R23 3/11
Page 4
www.protekdevices.com
05113
30KPA30A - 30KPA360A
Only One Name Means ProTek’Tion™
company information
COMPANY PROFILE
ProTek Devices, based in Tempe, Arizona USA, is a manufacturer of Transient Voltage Suppression (TVS) products designed specifically for
the protection of electronic systems from the effects of lightning, Electrostatic Discharge (ESD), Nuclear Electromagnetic Pulse (NEMP), inductive switching and EMI/RFI. With over 25 years of engineering and manufacturing experience, ProTek designs TVS devices that provide
application specific protection solutions for all electronic equipment/systems.
ProTek Devices Analog Products Division, also manufactures analog interface, control, RF and power management products.
CONTACT US
Corporate Headquarters
2929 South Fair Lane
Tempe, Arizona 85282
USA
By Telephone
General: 602-431-8101
Sales: 602-414-5109
Customer Service: 602-414-5114
By Fax
General: 602-431-2288
By E-mail:
Sales: [email protected]
Customer Service: [email protected]
Technical Support: [email protected]
Web
www.protekdevices.com
www.protekanalog.com
COPYRIGHT © ProTek Devices 2007 - This literature is subject to all applicable copyright laws and is not for resale in any manner.
SPECIFICATIONS: ProTek reserves the right to change the electrical and or mechanical characteristics described herein without notice.
DESIGN CHANGES: ProTek reserves the right to discontinue product lines without notice and that the final judgement concerning selection and specifications is the buyer’s and that in furnishing engineering
and technical assistance. ProTek assumes no responsibility with respect to the selection or specifications of such products. ProTek makes no warranty, representation or guarantee regarding the suitability of
its products for any particular purpose, nor does ProTek assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability without limitation special,
consequential or incidental damages.
LIFE SUPPORT POLICY: ProTek Devices products are not authorized for use in life support systems without written consent from the factory.
05113.R23 3/11
Page 5
www.protekdevices.com