05001 DA05N - DA24CP Only One Name Means ProTek’Tion™ High powered multi-line tvs array Description The DA16 Series are high powered multi-line TVS arrays available in a 16 pin DIP package. This series is designed to protect monitoring and industrial equipment from the damaging effects of ESD, EFT and secondary transient threats. The DA16 Series has a peak pulse power rating of 800 Watts for an 8/20µs waveshape. This devices meets the IEC 61000-4-2, IEC 61000-4-4 and IEC 61000-4-5 requirements. 16 pin dip package Features applications • Compatible with IEC 61000-4-2 (ESD): Air - 15kV, Contact - 8kV • Compatible with IEC 61000-4-4 (EFT): 40A - 5/50ns • Compatible with IEC 61000-4-5 (Surge): 24A, 8/20µs - Level 2(LineGnd) & Level 3(Line-Line) • 800 Watts Peak Pulse Power per Line (tp = 8/20µs) • Unidirectional & Bidirectional Configurations • ESD Protection > 25 kilovolts • Available in Multiple Voltages • Protects 8 to 12 Lines • RoHS Compliant • REACH Compliant • Low Frequency I/O Ports • RS-232 & RS-423 Data Lines • Power Bus Lines • Monitoring & Industrial Signal & Data Ports • Microprocessor Based Equipment Mechanical characteristics • Molded 16 Pin Dual-In-Line (DIP) Package • Approximate Weight: 1.2 grams • Lead-Free Pure-Tin Plating (Annealed) • Solder Reflow Temperature: Pure-Tin - Sn, 100: 260-270°C • Flammability Rating UL 94V-0 PIN CONFIGURATIONs UNIDIRECTIONAL BIDIRECTIONAL DAxxN Series DAxxCN Series 16 15 14 13 12 11 10 9 16 15 14 13 12 11 10 9 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 DAxxP Series DAxxCP Series 16 15 14 13 12 11 10 9 16 15 14 13 12 11 10 9 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 05001.R10 11/10 Page 1 www.protekdevices.com 05001 DA05N - DA24CP Only One Name Means ProTek’Tion™ typical device characteristics MAXIMUM RATINGS @ 25°C Unless Otherwise Specified PARAMETER Peak Pulse Power (tp = 8/20µs) - See Figure 1 Operating Temperature SYMBOL VALUE UNITS PPP 800 Watts TL -55 to 150 °C Storage Temperature TSTG -55 to 150 °C Forward Surge Rating IF 10 Amps ELECTRICAL CHARACTERISTICS PER LINE @ 25°C Unless Otherwise Specified PART NUMBER (Note 1) RATED STAND-OFF VOLTAGE minimum breakdown voltage MAXIMUM CLAMPING VOLTAGE (Fig. 2) MAXIMUM CLAMPING VOLTAGE (Fig. 2) MAXIMUM LEAKAGE CURRENT typical CAPACITANCE VWM VOLTS @1mA V(BR) VOLTS @ IP = 10A VC volts @ 8/20µs VC @ I PP @V WM ID µA @0V, 1MHz C pF DA05N 5.0 6.0 12.5 24.6V @ 45.0A 200 880 DA05P 5.0 6.0 12.5 24.6V @ 45.0A 200 880 DA05CN 5.0 6.0 12.5 24.6V @ 45.0A 200 500 DA05CP 5.0 6.0 12.5 24.6V @ 45.0A 200 500 DA12N 12.0 13.3 26.0 32.9V @ 34.0A 2 440 DA12P 12.0 13.3 26.0 32.9V @ 34.0A 2 440 DA12CN 12.0 13.3 26.0 32.9V @ 34.0A 2 385 DA12CP 12.0 13.3 26.0 32.9V @ 34.0A 2 385 DA15N 15.0 16.7 33.0 37.7V @ 27.0A 2 400 DA15P 15.0 16.7 33.0 37.7V @ 27.0A 2 400 DA15CN 15.0 16.7 33.0 37.7V @ 27.0A 2 300 DA15CP 15.0 16.7 33.0 37.7V @ 27.0A 2 300 DA24N 24.0 26.7 52.1 53.0V @ 20.0A 2 275 DA24P 24.0 26.7 52.1 53.0V @ 20.0A 2 275 DA24CN 24.0 26.7 52.1 53.0V @ 20.0A 2 200 DA24CP 24.0 26.7 52.1 53.0V @ 20.0A 2 200 notes 1. The “C” suffix denotes a bidirectional device, such as DA05CN. 05001.R10 11/10 Page 2 www.protekdevices.com 05001 DA05N - DA24CP Only One Name Means ProTek’Tion™ typical device characteristics figure 1 peak pulse power vs pulse time PPP - Peak Pulse Power - kilowatts 100 800W, 8/20µs Waveform 10 1 0.1 0.1 10 100 td - Pulse Duration - µs Peak Value IPP 80 100 TEST WAVEFORM PARAMETERS tf = 8µs td = 20µs e-t 60 40 10,000 figure 3 power derating curve Peak Pulse Power 8/20µs 80 % Of Rated Power tf 100 td = t/(IPP/2) 60 40 20 20 0 1,000 figure 2 pulse wave form 120 IPP - Peak Pulse Current - % of IPP 1 0 05001.R10 11/10 5 10 15 t - Time - µs 20 25 30 Page 3 0 Average Power 0 25 50 75 100 125 TA - Ambient Temperature - °C 150 www.protekdevices.com 05001 DA05N - DA24CP Only One Name Means ProTek’Tion™ 16 pin dip package information A outline dimensions dim millimeters inches min max min max A 18.80 19.55 0.740 0.770 B 6.35 6.85 0.250 0.270 C 7.50 7.74 0.295 0.305 D 0.21 0.38 0.008 0.015 E 0° 10° 0° 10° F 0.51 1.01 0.020 0.040 G 3.69 4.44 0.145 0.175 H 2.80 3.30 0.110 0.130 I 1.02 1.77 0.040 0.070 J 1.27 1.27 0.050 0.050 K 0.39 0.53 0.015 0.021 L 2.54 2.54 0.100 0.100 Orientation Dot (Pin #1) B I 12 Places C F G J 12 Places K 16 Places H D 16 Places E L Notes 1. Dimensions are exclusive of mold flash and metal burrs. 2. Dimensions “J” and “L” are between centers. ORDERING INFORMATION base PART NUMBER (xx = Voltage) LEADFREE SUFFIX TAPE SUFFIX QTY/REEL REEL SIZE TUBE qty DAxxN -LF n/a n/a n/a 25 DAxxP -LF n/a n/a n/a 25 DAxxCN -LF n/a n/a n/a 25 DAxxCP -LF n/a n/a n/a 25 Notes 1. Marking on Part - logo, part number, date code and pin one defined by dot on top of package. Package outline per document number 06003.R2 9/09. 05001.R10 11/10 Page 4 www.protekdevices.com 05001 DA05N - DA24CP Only One Name Means ProTek’Tion™ company information COMPANY PROFILE ProTek Devices, based in Tempe, Arizona USA, is a manufacturer of Transient Voltage Suppression (TVS) products designed specifically for the protection of electronic systems from the effects of lightning, Electrostatic Discharge (ESD), Nuclear Electromagnetic Pulse (NEMP), inductive switching and EMI/RFI. With over 25 years of engineering and manufacturing experience, ProTek designs TVS devices that provide application specific protection solutions for all electronic equipment/systems. ProTek Devices Analog Products Division, also manufactures analog interface, control, RF and power management products. CONTACT US Corporate Headquarters 2929 South Fair Lane Tempe, Arizona 85282 USA By Telephone General: 602-431-8101 Sales: 602-414-5109 Customer Service: 602-414-5114 By Fax General: 602-431-2288 By E-mail: Sales: [email protected] Customer Service: [email protected] Technical Support: [email protected] Web www.protekdevices.com www.protekanalog.com COPYRIGHT © ProTek Devices 1998 - This literature is subject to all applicable copyright laws and is not for resale in any manner. SPECIFICATIONS: ProTek reserves the right to change the electrical and or mechanical characteristics described herein without notice. DESIGN CHANGES: ProTek reserves the right to discontinue product lines without notice and that the final judgement concerning selection and specifications is the buyer’s and that in furnishing engineering and technical assistance. ProTek assumes no responsibility with respect to the selection or specifications of such products. ProTek makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does ProTek assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability without limitation special, consequential or incidental damages. LIFE SUPPORT POLICY: ProTek Devices products are not authorized for use in life support systems without written consent from the factory. 05001.R10 11/10 Page 5 www.protekdevices.com