CURRENT TRANSFORMER Electrical Specifications at 25OC Parameter Min. Typ. Max. Units Inductance * Pins 4-6 7.68 10.98 14.27 mH DCR (4-6) 130 mΩ DCR (1-8) 1.1 mΩ Isolation 3000 VAC * Tested at 100 mV, 1 kHz Turns Ratio = 50 : 1 Schematic Diagram Dimensions inches (mm) 1 6 8 .413 (10.50) MAX. .551 (14.00) TYP. .551 (14.00) MAX. Flammability: Materials used in the production of these units meet requirements of UL94-VO and IEC 695-2-2 needle flame test. .197 (5.00) TYP. .294 (7.50) TYP. .443 (11.25) TYP. 8 4 .294 (7.50) TYP. 6 Bottom View 1 4 RHOMBUS P/N: T-1171 CUST P/N: DATE: 9/12/98 1 OF 1 15801 Chemical Lane, Huntington Beach, CA 92649 Phone: (714) 898-0960 FAX: (714) 896-0971 Rhombus Industries Inc. Transformers & Magnetic Products NAME: SHEET: www.rhombus-ind.com