RHOMBUS-IND L-363

Common Mode Choke
Turns Ratio
Materials used in construction of this
component meet or exceed UL Class F (155oC)
1:1
Parameter
Inductance (1)
Min.
Typ.
Max.
Units
49
70
105
mH
DCR (1-8) or (4-5)
Leakage Inductance
(2)
Breakdown Voltage
2.80
Ω
900
nH
500
Flammability: Materials used in the
production of these units meet requirements
of UL94-VO and IEC 695-2-2 needle flame test.
VDC
Schematic
Diagram
1. Inductance tested at 10 kHz and 100mVRMS
2. Tested at 100 kHz and 100mVRMS
Physical Dimensions
1
4
8
5
inches (mm)
RHOMBUS P/N: L-363
CUST P/N:
DATE: 2/26/98
Rhombus
Industries Inc.
Transformers & Magnetic Products
NAME:
SHEET:
1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971
www.rhombus-ind.com