Industrial Power Supplies TEX Series, 120 Watt CB Features ◆ Rugged power supply for harsh outdoor Scheme UL 508 IP67 environments ◆ Die-cast aluminium housing ◆ Dust, water (incl. salt water), ice and oil resistant enclosure ◆ IP67 and NEMA 4X rated ◆ Connection via waterproof I/O plug-connectors ◆ Shock & vibration proof construction ◆ Operating temp. range -40°C to +85°C ◆ Universal input 85 to 264 VAC ◆ Output voltage adjustable ◆ DC-OK indicator ◆ Low ripple and noise ◆ Worldwide safety approvals ◆ Class I, zone 2 approval incl. ATEX certification ◆ 3-year product warranty These power supplies have been designed particularly for applications in extreme environments. The rugged die-cast aluminium housing is water, ice, oil and dust resistant in compliance with IP67 and NEMA 4X standards. The metal case works as an efficient heatsink allowing full power operation at up to +60°C ambient temperature (no fan required). With a shock and vibration proof construction the power supplies can be mounted directly on a machine. An International safety approval package includes CB scheme, EN/UL 60950-1 as well as UL508 listing. The power supply is also certified for class I, zone 2 for applications in hazardous locations i.e in chemical or food processing industries. The TEX series offers a cost efficient solution for de-centralized power systems in industrial automation applications with critical environment conditions. Models Order Code Output Power (max.) Output Voltage* (nom.) Output Current (max.) TEX 120-112 96 W 12 VDC 8.0 A TEX 120-124 120 W 24 VDC 5.0 A * adjustable http://www.tracopower.com Page 1 of 3 Industrial Power Supplies TEX 120 Series 120 Watt Input Specifications Input voltage – nominal 100 – 240 VAC – AC range 85 – 264 VAC – DC range 85 – 375 VDC (power derating tba) Input frequency 47 – 63 Hz Harmonic limits EN 61000-3-2, Class A Input current at full load (typ.) 1.0 A @ 230 VAC, 2.0 @ 115 VAC Recommended circuit breaker (characteristic C or slow blow fuse) 5.0 A Output Specifications Output voltage adjustable range 12 VDC model: 12 – 15 VDC 24 VDC model: 24 – 28 VDC Output regulation (10 to 90% load variation) 2.5 % Ripple and noise (20MHz bandwidth) <50 mV pk-pk Electronic short circuit protection current limitation at 110 % typ. (automatic recovery) Output overvoltage protection <40 V Hold-up time >20 ms General Specifications Temperature range – Operating – 40 °C to + 85 °C max. Power derating above + 60 °C 2.0 %/K Humidity up to 100% rel. H with condensation Reliability (calculated MTBF according IEC 61709) >900‘000h @ 40 °C Altitude 3000 m max. (10‘000 ft) Safety standards – Information technology equipment – Control equipment for hazardous location – Electrical equip. for potentially explosive atmospheres – Industrial control equipment – Electrical equipment for machines – Electronic equipment for power installation – Safety transformers Safety approvals and certifications (in process) IEC/EN 60950-1 UL 1604 (Class I, Division 1 & 2, group A, B, C & D, T4) IEC/EN 60079-15 (Class I, Zone 2, EEx nA IIC T4) UL 508 EN 60204-3 EN 50178 EN 61558-2-8 – CB report IEC/EN 60950-1 – UL approvals UL 508 listing, UL 1604 – IEC ATEX, IECEx scheme All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. http://www.tracopower.com Page 2 of 3 Industrial Power Supplies TEX 120 Series 120 Watt General Specifications Electromagnetic compatibility (EMC), emissions EN 61000-6-3 – Conducted RI suppression on input EN 55022 class B – Radiated RI suppression EN 55022 class B Electromagnetic compatibility (EMC), immunity – Electrostatic discharge (ESD) – Radiated RF field immunity – Electrical fast transient / burst immunity input – Electrical fast transient / burst immunity output – Surge immunity line – neutral – Surge immunity line – ground – Surge immunity neutral – ground – Surge immunity output – Immunity to conducted RF disturbances – Mains voltage dips and interruptions EN 61000-6-2 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-4 EN 61000-4-5 EN 61000-4-5 EN 61000-4-5 EN 61000-4-5 EN 61000-4-6 EN 61000-4-11 8 kV / 15 kV 10 V/m 4 kV / 2 kV 4 kV 2 kV 4 kV 0.5 kV 10 V 30 % /10 mS, 60 % /100 mS Safety class degree of protection class I Case protection IP 67 (IEC 60529), NEMA 4X rated, UL 50 Environment – Vibration IEC 60068-2-6 – Shock IEC 60068-2-27 Enclosure material die-cast aluminium Weight 1000 g (35.3 oz) Installation instructions www.tracopower.com/products/tex120_inst.pdf Case Dimensions Output Input 5 1 2 4 56 (2.20) 2 1 INPUT 174 (6.85) 164 (6.46) 83 (3.27) 3 OUTPUT 1 L 1 2 N 2 PE 3 - 4 5 6 + + + Mating Connectors* 154 (6.06) 93 (3.66) 6 AC Input Amphenol 4-pin female circular plug C016 20D003 110 12 DC Output Amphenol 6-pin male circular plug C016 30H006 110 12 *not included in shipment! (Units are supplied with sealing connector caps) Specifications can be changed any time without notice. Dimensions in [mm], () = Inch Tolerances: ± 0.5 mm (±0.02) Rev. 10/08.1 Jenatschstrasse 1 · CH-8002 Zurich · Switzerland Tel. +41 43 311 45 11 · Fax +41 43 311 45 45 · [email protected] · www.tracopower.com Page 3 of 3