INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS
TEX 120 Series
Industrial Power Supply
Table 1
Order Code
Rated Input
Voltage
Output
Power max.
Output
TEX 120-112
100 – 240Vac
96 Watt
12.0VDC / 8.0A
12.0 – 15.0VDC
5A
120 Watt
24.0VDC / 5.0A
24.0 – 28.0VDC
5A
TEX 120-124
50 / 60Hz
Universal Input
** Output Voltage
recommended Circuit
Adjustment Range breaker (Characteristic C)
** Adjustable by potentiometer with a screwdriver.
The equipment can be connected to TN-S, TT and IT power systems
Table 2
Input current:
@ Vin=115VAC
@ Vin=230VAC
Power Consumption @ Vin=115VAC @ Vin=230VAC
 TEX 120-112
2.2A typ.
1.0A typ.
 TEX 120-112
114 Watt typ.
112 Watt typ.
 TEX 120-124
2.4A typ.
1.2A typ.
 TEX 120-124
140 Watt typ.
136 Watt typ.
Table 3
Operational Input Voltage
AC: 85Vac – 264Vac, 50 / 60Hz. DC: 85Vdc* – 375Vdc (*Observe derating)
Operating temperature range:
-40°C – +85°C max (Atex: -40°C - +70°C) (*Observe derating)
Natural Air Convection
-40°F – +185°F max (Atex: -40°F - +158°F) (*Observe derating)
Cooling
%
Output Power Derating:
above +60°C  2 /K
%
above 140°F  2 /K
Storage temperature range:
-40°C – +85°C max
-40°F – +185°F max
Parallel Operation:
Only possible with external decoupling diode.
Temp: -40°C – +125°C (-40°F – + 257°F)
Input Cable Assembly: See Fig.2 (Tracopower P/N: TEX–IP–ASSY, 3 x 1.3mm²)
Input Connector: Binder Circular Connector Series 693: 99-4222-14-04
Output Cable Assembly: See Fig.3 (Tracopower P/N: TEX–OP–ASSY, 7 x 0.8mm²)
Output Connector: Binder Circular Connector Series 693: 99-4217-160-07
Input: 3 x 0.8mm2 – 2mm2 max (AWG 18 – AWG 14) (1 x Live; 1 x Neutral; 1 x Protective Earth)
Output: 7 x 0.8mm2 – 1.3mm2 max (AWG18– AWG 16) (3 x +Vout; 3 x –Vout; 1 x Protective Earth).
Case protection:
IP67 (according to IEC 60529), NEMA 6P, UL50 4X
Case material:
Die-Cast Aluminium (chassis and cover)
Connectors on the user side:
(see Fig. 2 & Fig. 3)
Wiring: Material  Copper
Input: TEX-IP-ASSY Cord Diameter = 10 – 12mm / Output: TEX-OP-ASSY Cord Diameter = 12 – 14mm
Output Voltage adjustment:
Output
Fig. 1
http://www.tracopower.com
Input
Note: The integrity of the seal cannot be guaranteed once the
cover has been removed in the field!
To adjust the output voltage, the case cover must be removed.
Carefully loosen and remove all six screws, then remove the cover.
The output voltage of the unit can be adjusted by turning the
potentiometer screw, using an insulated screwdriver. By turning the
screw clockwise (cw) the output voltage will increase; by turning the
screw counter-clockwise (ccw), the output voltage will decrease. The
output voltage level should only be adjusted with the output
connected to a load, (similar to the load used in the application). After
adjusting the output voltage to the required value, the case must be
carefully reassembled. Place the cover over the case and ensure that
the rubber-sealing gasket is undamaged, and is correctly positioned.
Secure the lid with the six screws. Tighten the screws gradually,
moving diagonally from one to another. The recommended tightening
torque is 0.6Nm (5.310lb·in).
Rev: 5.4/3812
Safety Instructions:
 Before installation read these instructions carefully and
completely. This installation instruction cannot account for
every possible condition of installation, operation or
maintenance. Further information can be obtained from
your local distributor’s office or from the product datasheet,
which can be downloaded, from our website:
http://tracopower.com/products/tex120.pdf. You will find
additional information in our Instruction Manual, which can
also
be
downloaded
from
the
website:
http://www.tracopower.com/products/tex120_manual.pdf.
 These power supplies are constructed in accordance with the
safety requirements of EN60079-0:2009 & EN60079-15:2010,
Ex nA IIC T4 Gc.
Only trained personnel may open the power supply. Once the
cover is opened, the warranty is void!
Do not introduce any objects into the power supply. The output
voltage adjustment potentiometer may only be actuated using
an insulated screwdriver.
Keep away from fire
 The mains supply voltage connection, must be in
WARNING: – POTENTIAL ELECTROSTATIC CHARGING HAZARD –
accordance to IEC 62103, EN 50178 and IEC 60364, VDE
100.
Prevent unintentional contact with a dry cloth.
 Before any installation, maintenance or modification work
Do NOT clean surfaces with a dry cloth!
ensure that the main switch is switched off and prevented
Clean ONLY with a damp cloth.
from being switched on again. Normally, live components
cannot be touched, but while adjusting the output voltage Installation Instructions:
live components can be touched. Non-observance,
touching of any live components or improper handling of
this power supply can result in death, severe personal  User-side connector/Cable assemblies shown in Fig. 2 and
Fig. 3 on page 3.
injury or substantial property damage. Proper and safe
operation is dependent on proper storage, handling,
installation and operation.
 Compliance with the relevant national regulations (in the
USA, Europe and other countries) must be ensured.
Before operation is started the following conditions must
be ensured:
 Connection to mains supply in compliance with national
regulations (VDE0100 and EN50178).
 By use of stranded wires, all strands must be fastened
in the terminal blocks. (Potential danger of contact with
the case)
 Power supply and mains wires must be sufficiently
fused.
 Degree of protection I to IEC536.The non-fused protective earth connection must be connected to the FG
terminal (Protection Class I).
 All output wires must be rated for the power supply output current and must be connected with the correct
polarity.
 Sufficient cooling must be ensured.
 Never work on the power supply if power is supplied!
Risk of electric arcs and electrical shock, which can cause
death, severe personal injury or substantial property damage.
 Copper conductors rated min. 60/75C only are to be used.
 Wire size 18-14 AWG only are to be used. (See Table 3)
 These devices are intended for installation on industrial
machines in accordance with the "Electrical Standard for
Industrial Machinery" (NFPA79). Due to the nature of these
devices they may not be suitable for installation accordance
with the "National Electrical Code" (NFPA70).
 The suitability of the use of flexible cord per CEC, PART I,
Rule 4-010, is to be determined by the local inspection
authority having jurisdiction
 This power supply is designed for professional outdoor
systems as well as indoor systems. It may be installed and
put into service by qualified personnel only.
 Do not operate without PE connection! To comply with EMC
and safety standards (CE mark, approvals) the power supply must be operated only if PE terminal is connected to the
non-fused earth conductor.
 The correct mounting position for optimal cooling performance must be observed. Do not cover any ventilation
holes. Leave a free space of minimum 50mm (2in.) above
and below the power supply. Observe power derating.
 The internal fuse is not accessible, as the user may not replace it. If this internal fuse has blown, the power supply
has an internal defect and, for safety reasons, must be
shipped to the local distributor. In case this internal fuse
has to be replaced in the field, replace only with same type
and rating of fuse for continued protection against risk of
fire.
 Warning: Hazardous voltages and components storing a
very substantial amount of energy are present in this
power supply during normal operating conditions. However,
these are inaccessible. Improper handling may result in an
electric shock or serious burns! Do not open the power

supply until at least 5 minutes after it has been disconnected from the mains on all poles.
 Class I Equipment (Chassis earthed)
 Do not operate voltage adjustment when an explosive
atmosphere may be present
 Do not disconnect while circuit is alive, unless area is
know to be non-hazardous.

http://www.tracopower.com
When no connector is connected to the unit, the connectors
shall be sealed with the cover caps to maintain the degree
of protection.
Cover cap for Input connector 08-2301-000-000
Cover cap for Output connector 08-2302-000-000
Recycling: The unit contains elements that are suitable
for recycling, and components that need
special disposal. You are therefore requested
to make sure that the power supply will be
recycled at the end of its service life.
Rev: 5.4/ 3812
Part Number: TEX–IP–ASSY
Order Code: TEX-C11
NOTE: Core wires may be marked or
coloured to distinguish each
connection for wiring purposes.
2.0
m
Wire
Colour
RED
BLACK
WHITE
Connector
Terminal
1
2
Earth
Fig. 2
Part Number: TEX–OP–ASSY
Order Code: TEX-C21
NOTE: Core wires may be marked or
coloured to distinguish each
connection for wiring purposes.
2. 0
m
Wire
Colour
BLUE
ORANGE
GREEN
RED
WHITE
BLACK
BLACK &
WHITE
Connector
Terminal
1
2
3
4
5
6
Earth