Data Sheet 100VAC Input/−5VDC (200mA) Output Non-Isolated AC/DC Converter with Built-In Zero Cross Signal Output BP5011 Absolute Maximum Ratings Dimensions (Unit : mm) MARKING SIDE 1 2 3 4 5 2.54±0.2 Max. −170 −5.3 200 0.15 0.15 0.15 − −0.3 −5.3 Conditions DC − ∗1 − Vi= −85 to −170V Io=0 to 200mA ∗2 Io=200mA Io=200mA V1, V2=2.3V, RZ1, 2=4kΩ V1, V2= −5.3V, RZ1, 2=4kΩ Unit V V mA V V Vp-p % V V Application Circuit 13 0.25±0.05 1.3±0.2 4.5MAX. 3.6MAX. Derating Curve 250 200 150 Operation Range 100 50 0 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 Ambient Temperature Ta (°C) ∗1 Max output current should be reduced according to the surrounding temperature. ∗2 Spike noise is not included in output ripple voltage. Conversion Efficiency Function Zero-cross signal output2(Vz2) Zero-crosssignal output1 (Vz1) Output (Vo) Common Coil 1 (Coil-1) Skip Coil 2 (Coil-2) Skip Input (Vi) Skip Zero-cross input2 (ACin2) Skip Zero-cross input1 (ACin1) Zero-cross signal2 Zero-cross signal1 BP5011 13 11 9 7 F1 D1 3 4 5 1 2 L1 Vo R1 R2 ZNR + C1 C3 Be sure to use a fuse for the safety. + 100 90 80 70 60 50 40 30 20 10 0 Conversion Efficiency (Vi= −141V,Ta=25°C) Conversion Efficiency (%) Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 11 Derating Curve Output Current Io (mA) Typ. −141 −5.0 − 0.01 0.01 0.06 68 − −5.0 9 2.54�12=30.48TYP (Unless otherwise noted, Ta=25°C,Vi= −141V, lo=100mA) Symbol Min. Parameter Vi −85 Input voltage range Vo −4.7 Output voltage Io − Output current Vr − Line regulation Vl − Load regulation Vp − Output ripple voltage η 60 Power conversion efficiency VZH 0 Zero-cross signal H VZL −4.4 Zero-cross signal L 7 0.5±0.1 3.0M A X Electrical Characteristics 8.1MAX. 35.1MAX. Mark Side Unit V Vrms °C °C °C mA Limits −170 120 −20 to +85 −25 to +105 105 200 17.4MAX. Symbol Vi V1,V2 Topr Tstg Tsmax Io 4±1.0 Parameter Input voltage Zero-cross input voltage Operating temperature range Storage temperature range Maximum surface temperature Maximum output current 0 R3 50 100 150 Output Current Io (mA) 200 C2 Load Regulation coil start Please verify operation and characteristics in the customer's circuit before actual usage. Ensure that the load current does not exceed the maximum rating. F1: FUSE C1: Input capacitor Use a fast-acting fuse of 1.0A. Rated voltage : 250V or higher Capacitance : 22 to 100µF C2: Output capacitor Rated voltage : 10V or higher Capacitance : 100 to 470µF, Low impedance type ESR : Less than 0.16Ω Rated ripple current : Beyond 0.58Arms Evaluate under actual operating conditions since it affects the output ripple voltage. C3: Noise removal capacitor Rated voltage : 250V or higher Capacitance : 0.1 to 0.22µF Film or ceramic capacitor L1: Power inductor R1: Noise removal resistor Output Voltage −Vo (V) External Component Specifications Load Regulation (Vi= −141V,Ta=25°C) 6.0 5.0 4.0 3.0 Maximum lo=200mA 2.0 1.0 0.0 0 50 100 150 200 250 Output Current Io (mA) 300 Inductance : 560µH Rated current : More than 0.52A Resistance : 10 to 22Ω Power : More than 1/4W R2,R3 : Pull-up resistor Pull-up resistor for zero-cross signal. 4kΩ 1/10W D1: Rectifier diode Peak reverse voltage : More than 400V Mean rectifying current : More than 1.0A Peak forword surge current : More than 20A Full-wave rectification can be used. ZNR : Varistor A varistor is required to protect against lightning surges and static electricity. www.rohm.com ©2010 ROHM Co., Ltd. All rights reserved. 1/1 2010.01 - Rev.A Notice Notes No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from ROHM upon request. Examples of application circuits, circuit constants and any other information contained herein illustrate the standard usage and operations of the Products. The peripheral conditions must be taken into account when designing circuits for mass production. Great care was taken in ensuring the accuracy of the information specified in this document. However, should you incur any damage arising from any inaccuracy or misprint of such information, ROHM shall bear no responsibility for such damage. The technical information specified herein is intended only to show the typical functions of and examples of application circuits for the Products. ROHM does not grant you, explicitly or implicitly, any license to use or exercise intellectual property or other rights held by ROHM and other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the use of such technical information. The Products specified in this document are intended to be used with general-use electronic equipment or devices (such as audio visual equipment, office-automation equipment, communication devices, electronic appliances and amusement devices). The Products specified in this document are not designed to be radiation tolerant. While ROHM always makes efforts to enhance the quality and reliability of its Products, a Product may fail or malfunction for a variety of reasons. Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability the failure or malfunction of which may result in a direct threat to human life or create a risk of human injury (such as a medical instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuelcontroller or other safety device). ROHM shall bear no responsibility in any way for use of any of the Products for the above special purposes. If a Product is intended to be used for any such special purpose, please contact a ROHM sales representative before purchasing. If you intend to export or ship overseas any Product or technology specified herein that may be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to obtain a license or permit under the Law. Thank you for your accessing to ROHM product informations. More detail product informations and catalogs are available, please contact us. ROHM Customer Support System http://www.rohm.com/contact/ www.rohm.com © 2010 ROHM Co., Ltd. All rights reserved. R1010A