MAXIM DS1721S

DS1721
2-Wire Digital Thermometer
and Thermostat
www.maxim-ic.com
FEATURES
§
§
§
§
§
§
§
§
§
Temperature measurements require no
external components with ±1°C accuracy
Measures temperatures from -55°C to
+125°C; Fahrenheit equivalent is -67°F to
+257°F
Temperature resolution is configurable from 9
to 12 (default) bits (0.5°C to 0.0625°C
resolution)
Maximum conversion time (9-bit resolution)
of 93.75 ms
Thermostatic settings are user-definable
Data is read/written via a 2-wire serial
interface (open drain I/O lines); 3-bit
addressability
Wide power supply range (2.7V - 5.5V)
Applications include personal computers,
cellular telephones, office equipment, or any
thermally sensitive system
8-pin, 150-mil SOIC package and 8-pin µSOP
package
PIN ASSIGNMENT
SDA
1
8
VDD
SCL
2
7
A0
TOUT
3
6
A1
GND
4
5
A2
SDA
SCL
TOUT
GND
DS1721S
8-Pin SOIC (150-mil)
1*
8
2
7
3
6
VDD
A0
A1
4
5
A2
DS1721U
8-Pin µ-SOP
PIN DESCRIPTION
SDA
SCL
GND
TOUT
A0
A1
A2
VDD
- 2-Wire Serial Data Input/Output
- 2-Wire Serial Clock
- Ground
- Thermostat Output Signal
- Chip Address Input
- Chip Address Input
- Chip Address Input
- Power Supply Voltage (+5V)
DESCRIPTION
The DS1721 2-Wire Digital Thermometer and Thermostat provides 12-bit temperature readings, which
indicate the temperature of the device. Thermostatic settings and temperature readings are all
communicated to/from the DS1721 over a simple 2-wire serial interface. No additional components are
required; the device is truly a “temperature-to-digital” converter.
The DS1721 has three address bits that allow a user to multidrop up to eight sensors along the 2-wire bus,
greatly simplifying the bussing of distributed temperature sensing networks.
The thermal alarm output, TOUT, is active when the temperature of the device exceeds a user-defined
temperature TH. The output remains active until the temperature is equal to or below the user-defined
temperature TL, allowing for any hysteresis necessary. The active state of TOUT is configurable by the
user.
For applications that require faster conversion times, the user can adjust the readout resolution from 12 to
9 bits, effectively reducing the conversion time from 750ms (MAX) to 93.75 ms (MAX). This is
particularly useful in applications where temperature changes large magnitudes very rapidly.
Applications for DS1721 include personal computers/services, cellular telephones, office equipment, or
any microprocessor-based, thermally sensitive system.
1 of 17
110405
DS1721
ORDERING INFORMATION
ORDERING
INFORMATION
DS1721S
DS1721S+
DS1721S/T&R
DS1721S+T&R
PACKAGE
MARKING
DS1721
DS1721 (See Note)
DS1721
DS1721 (See Note)
DS1721U
DS1721U+
DS1721U/T&R
DS1721U+T&R
1721
1721 (See Note)
1721
1721 (See Note)
DESCRIPTION
DS1721 in 150 mil 8-pin SO
DS1721 in Lead-Free 150 mil 8-pin SO
DS1721 in 150 mil 8-pin SO, 2500 Piece Tape-and-Reel
DS1721 in Lead-Free 150 mil 8-pin SO, 2500 Piece Tapeand-Reel
DS1721 in 8-pin uSOP
DS1721 in Lead-Free 8-pin uSOP
DS1721 in 8-pin uSOP, 3000 Piece Tape-and-Reel
DS1721 in Lead-Free 8-pin uSOP, 3000 Piece Tape-and-Reel
Note: A ”+” symbol will also be marked on the package near the Pin 1 indicator.
DETAILED PIN DESCRIPTION Table 1
PIN
1
2
3
SYMBOL
SDA
SCL
TOUT
4
5
6
7
8
GND
A2
A1
A0
VDD
DESCRIPTION
Data input/output pin. For 2-wire serial communication port.
Clock input/output pin. For 2-wire serial communication port.
Thermostat output. Active when temperature exceeds TH; will reset when
temperature falls below TL.
Ground pin.
Address input pin.
Address input pin.
Address input pin.
Supply Voltage. 2.7V to 5.5V input power pin.
OVERVIEW
A block diagram of the DS1721 is shown in Figure 1.
The DS1721 consists of five major components:
1. Precision temperature sensor
2. Analog-to-digital converter
3. 2-wire interface electronics
4. Data registers
5. Thermostat comparator
The factory-calibrated temperature sensor requires no external components. Upon power-up, the DS1721
is in an idle mode. Upon issuance of a Start Convert T command [51h], the DS1721 begins temperature
conversions with the default resolution of 12 bits (0.0625°C resolution). Following an 8-bit command
protocol, temperature data can be read over the 2-wire interface. The host can periodically read the value
in the temperature register, which contains the last completed conversion. As conversions are performed
in the background, reading the temperature register does not affect the conversion in progress.
In power-sensitive applications, the user can put the DS1721 in a “one-shot” mode, under which the
sensor will complete and store one temperature conversion and return to a low-power standby state. In
time-sensitive applications, the user can change the conversion resolution from 12 bits to 9, 10, or 11.
2 of 17
DS1721
Each additional bit of resolution approximately doubles the conversion time, so 9-bit conversions can be
performed in less than a quarter of a second.
This is accomplished by issuing a command protocol to the configuration register. It is recommended that
the user issue the command protocol to program the configuration register before any temperature
conversion commands are issued after power-up. This is due to the fact that the configuration data is
stored in volatile memory and will always power-up in the default state. The configuration register
defines the conversion mode, thermometer resolution/conversion time, and active state of the thermostat
comparator output. It also contains 3 status bits denoting the state of temperature conversions and
thermostat flags.
The user can also program over-temperature (TH) and under-temperature (TL) setpoints for thermostatic
operation. The power-up state of TH is 80°C and that for TL is 75°C. The result of each temperature
conversion is compared with these setpoints. The thermostat output (TOUT) becomes active when the
measured temperature exceeds the programmed TH, and remains latched in the active state until
temperature falls below TL. Thus, any hysteresis can be realized for fan control without external
components.
Digital data is written to/read from the DS1721 via a 2-wire interface, and all communication is MSb
first. Multipoint sensing is possible with the DS1721 by uniquely setting the 3-bit address of up to eight
parts on the 2-wire bus.
DS1721 FUNCTIONAL BLOCK DIAGRAM Figure 1
3 of 17
DS1721
OPERATION-Measuring Temperature
The core of DS1721 functionality is its direct-to-digital temperature sensor. The DS1721 measures
temperature through the use of an on-chip temperature measurement technique with an operation range
from -55°C to +125°C. The device can be configured to perform continuous conversions with the most
recent result being stored in the thermometer register. The device can also be configured to perform a
single conversion, store the result, and return to a standby mode. Regardless of the mode used, the digital
temperature is retrieved from the temperature register using the Read Temperature (AAh) command, as
described in detail in the “Command Set” section. The DS1721 power-up default has the sensor set to
automatically perform 12-bit conversions continuously once the Start Convert T (51h) command is
issued. Details on how to change the settings after power-up are contained in the “OPERATIONProgramming” section.
The resolution of the temperature conversion can be configured as 9, 10, 11, or 12 bits, with 12-bit
readings as the default state. This equates to a temperature resolution of 0.5°C, 0.25°C, 0.125°C, or
0.0625°C. Following each conversion thermal data is stored in the thermometer register in two’s
complement format; the information can be retrieved over the 2-wire interface by issuing a Read
Temperature (AAh) command. Table 2 describes the exact relationship of output data to measured
temperature. The table assumes the DS1721 is configured for 12-bit resolution; if the device is configured
in a lower resolution mode, insignificant bits will contain zeros. The data is transmitted serially over the
2-wire serial interface, MSb first. The MSb of the temperature register contains the “sign” (S) bit,
denoting whether the temperature is positive or negative. For Fahrenheit usage, a lookup table or
conversion routine must be used.
TEMPERATURE/DATA RELATIONSHIPS Table 2
S
MSb
2-1
26
25
2-2
2-3
TEMP
+125°C
+25.0625°C
+10.125°C
+0.5°C
+0°C
-0.5°C
-10.125°C
-25.0625°C
-55°C
24
23
(UNIT = °C)
2-4
0
DIGITAL OUTPUT
(Binary)
0111 1101 0000 0000
0001 1001 0001 0000
0000 1010 0010 0000
0000 0000 1000 0000
0000 0000 0000 0000
1111 1111 1000 0000
1111 0101 1110 0000
1110 0110 1111 0000
1100 1001 0000 0000
22
21
0
0
20
LSb
0
MSB
LSB
DIGITAL OUTPUT
(Hex)
7D00h
1910h
0A20h
0080h
0000h
FF80h
F5E0h
E6F0h
C900h
OPERATION-Thermostat Control
In its operating mode, the DS1721 functions as a thermostat with programmable hysteresis, as shown in
Figure 2. The thermostat output updates as soon as a temperature conversion is complete. When the
DS1721’s temperature meets or exceeds the value stored in the high temperature trip register (TH), the
output becomes active, and will stay active until the temperature is equal to or below the temperature
stored in the low temperature trigger register (TL). In this way, any amount of hysteresis may be
obtained.
4 of 17
DS1721
The active state for the totem-pole output is programmable by the user. The power-up default of the
DS1721 has TH=80°C, TL=75°C, and the output state active high. Refer to the “OPERATIONProgramming” section for instructions in adjusting the thermostat setpoints and TCOM active state.
THERMOSTAT OUTPUT OPERATION Figure 2
OPERATION-Programming
There are two areas of interest in programming the DS1721: the Configuration/Status register and the
thermostat setpoints. All programming is done via the 2-wire interface using the protocols discussed in
the “Command Set” section.
Configuration/Status Register Programming
The configuration/status register is accessed via the Access Config (ACh) function command. Writing to
or reading from the register is determined by the R/ W bit of the 2-wire control byte (See “2-wire Serial
Data Bus” section). Data is read from or written to the configuration register MSb first. The format of the
register is illustrated below in Figure 3. The effect each bit has on DS1721 functionality is described
below along with the power-up state of the bit and its ability to be read or written to. The entire register is
volatile and will always power-up in the default state. Therefore, it is recommended that the user issue
any configuration programming commands immediately after power is cycled, before any other
commands are issued.
CONFIGURATION/STATUS REGISTER Figure 3
DONE
MSb
X
X
U
R1
R0
POL
1SHOT
LSb
1SHOT = Temperature Conversion Mode. If 1SHOT is "1", the DS1721 will perform and store one
temperature conversion upon reception of the Start Convert T (51h) command. If 1SHOT is "0", the
DS1721 will continuously perform temperature conversions and store the last completed result in the
Thermometer Register. The user has read/write access to the bit and the power-up default state is "0"
(continuous mode).
POL = TCOM Polarity Bit. If POL is "1", the active state of the TCOM output will be high. A "0" stored
in this location sets the thermostat output to an active low state. The user has read/write access to the
POL bit, and the power-up default state is "1" (active high).
U = Undefined. This bit is used internally by the DS1721. It will be a "0" at power-up and will change to
a "1" once the Start Convert T [51h] command is issued. This is a “Don’t Care” on a write; i.e. The
DS1721 will ignore writes to this location.
5 of 17
DS1721
R0, R1 = Thermometer Resolution Bits. Table 3 below defines the resolution of the digital thermometer,
based on the settings of these two bits. There is a direct tradeoff between resolution and conversion time,
as depicted in the DC Electrical Characteristics: Digital Thermometer table. The designer has read/write
access to R0 and R1, and the default state is R0="1" and R1="1" (12-bit conversions).
THERMOMETER RESOLUTION CONFIGURATION Table 3
R1
0
0
1
1
MAX
CONVERSION
TIME
93.75ms
187.5ms
375ms
750ms
THERMOMETER
RESOLUTION
9-BIT
10-BIT
11-BIT
12-BIT
R0
0
1
0
1
X = Undefined. These bits are used internally by the DS1721.
DONE = Temperature Conversion Status Bit. "1" = conversion complete and "0" = conversion in
progress. The DONE bit is read-only, and the power-up state is "1". In the continuous conversion mode,
DONE = "0".
Thermostat Setpoints Programming
The thermostat registers (TH and TL) define the setpoints for operation of the TCOM output. The
respective register can be accessed over the 2-wire bus via the Access TH (A1h) or Access TL (A2h)
commands. Reading from or writing to the respective register is controlled by the state of the R/ W bit in
the 2-wire control byte (See “2-Wire Serial Data Bus” section).
The format of the TH and TL registers is a 12-bit 2’s complement representation of the temperature in °C.
The user can program the number of bits (9, 10, 11, or 12) for each TH and TL that correspond to the
thermometer resolution configuration chosen. If the 9-bit mode is chosen, for example, the 3 least
significant bits of TH and TL will be ignored by the thermostat comparator. The format for both TH and
TL is shown in Figure 4. The power-up default of TH is 80°C and that for TL is 75°C.
TEMPERATURE/DATA RELATIONSHIPS Figure 4
S
MSb
2-1
26
25
2-2
2-3
TEMP
+80°C
+75°C
+10.125°C
+0.5°C
+0°C
-0.5°C
-10.125°C
-25.0625°C
-55°C
24
23
(UNIT = °C)
2-4
0
DIGITAL OUTPUT
(Binary)
0101 0000 0000 0000
0100 1011 0000 0000
0000 1010 0010 0000
0000 0000 1000 0000
0000 0000 0000 0000
1111 1111 1000 0000
1111 0101 1110 0000
1110 0110 1111 0000
1100 1001 0000 0000
6 of 17
22
21
0
0
20
LSb
0
MSB
LSB
DIGITAL OUTPUT
(Hex)
5000h
4B00h
0A20h
0080h
0000h
FF80h
F5E0h
E6F0h
C900h
DS1721
If the user does not wish to take advantage of the thermostat capabilities of the DS1721, the 24 bits can be
used for general storage of system data that need not be maintained following a power loss. However, the
TOUT pin should be left floating if general data is stored in TH/TL.
2-WIRE SERIAL DATA BUS
The DS1721 supports a bi-directional 2-wire bus and data transmission protocol. A device that sends data
onto the bus is defined as a transmitter, and a device receiving data as a receiver. The device that controls
the message is called a “master.” The devices that are controlled by the master are “slaves.” The bus must
be controlled by a master device which generates the serial clock (SCL), controls the bus access, and
generates the START and STOP conditions. The DS1721 operates as a slave on the 2-wire bus.
Connections to the bus are made via the open-drain I/O lines SDA and SCL.
The following bus protocol has been defined (See Figure 5):
·
Data transfer may be initiated only when the bus is not busy.
·
During data transfer, the data line must remain stable whenever the clock line is HIGH. Changes in
the data line while the clock line is high will be interpreted as control signals.
Accordingly, the following bus conditions have been defined:
Bus not busy: Both data and clock lines remain HIGH.
Start data transfer: A change in the state of the data line, from HIGH to LOW, while the clock is HIGH,
defines a START condition.
Stop data transfer: A change in the state of the data line, from LOW to HIGH, while the clock line is
HIGH, defines the STOP condition.
Data valid: The state of the data line represents valid data when, after a START condition, the data line
is stable for the duration of the HIGH period of the clock signal. The data on the line must be changed
during the LOW period of the clock signal. There is one clock pulse per bit of data.
Each data transfer is initiated with a START condition and terminated with a STOP condition. The
number of data bytes transferred between START and STOP conditions is not limited, and is determined
by the master device. The information is transferred byte-wise and each receiver acknowledges with a 9th
bit.
Within the bus specifications a regular mode (100 kHz clock rate) and a fast mode (400 kHz clock rate)
are defined. The DS1721 works in both modes.
Acknowledge: Each receiving device, when addressed, is obliged to generate an acknowledge after the
reception of each byte. The master device must generate an extra clock pulse which is associated with this
acknowledge bit.
A device that acknowledges must pull down the SDA line during the acknowledge clock pulse in such a
way that the SDA line is stable LOW during the HIGH period of the acknowledge related clock pulse. Of
course, setup and hold times must be taken into account. A master must signal an end of data to the slave
by not generating an acknowledge bit on the last byte that has been clocked out of the slave. In this case,
the slave must leave the data line HIGH to enable the master to generate the STOP condition.
7 of 17
DS1721
DATA TRANSFER ON 2-WIRE SERIAL BUS Figure 5
Figure 6 details how data transfer is accomplished on the two-wire bus. Depending upon the state of the
R/ W bit, two types of data transfer are possible:
Data transfer from a master transmitter to a slave receiver. The 1st byte transmitted by the master is
the slave address. Next follows a number of data bytes. The slave returns an acknowledge bit after each
received byte.
Data transfer from a slave transmitter to a master receiver. The 1st byte (the slave address) is
transmitted by the master. The slave then returns an acknowledge bit. Next follows a number of data
bytes transmitted by the slave to the master. The master returns an acknowledge bit after all received
bytes other than the last byte. At the end of the last received byte, a ‘not acknowledge’ is returned.
The master device generates all of the serial clock pulses and the START and STOP conditions. A
transfer is ended with a STOP condition or with a repeated START condition. Since a repeated START
condition is also the beginning of the next serial transfer, the bus will not be released.
The DS1721 may operate in the following two modes:
Slave receiver mode: Serial data and clock are received through SDA and SCL. After each byte is
received, an acknowledge bit is transmitted. START and STOP conditions are recognized as the
beginning and end of a serial transfer. Address recognition is performed by hardware after reception of
the slave address and direction bit.
Slave transmitter mode: The first byte is received and handled as in the slave receiver mode. However,
in this mode, the direction bit will indicate that the transfer direction is reversed. Serial data is transmitted
on SDA by the DS1721 while the serial clock is input on SCL. START and STOP conditions are
recognized as the beginning and end of a serial transfer.
8 of 17
DS1721
2-WIRE SERIAL COMMUNICATION WITH DS1721 Figure 6
9 of 17
DS1721
SLAVE ADDRESS
A control byte is the 1st byte received following the START condition from the master device. The
control byte consists of a 4-bit control code; for the DS1721, this is set as 1001 binary for read and write
operations. The next 3 bits of the control byte are the device select bits (A2, A1, A0). They are used by
the master device to select which of eight devices are to be accessed. The set bits are in effect the 3 least
significant bits of the slave address. The last bit of the control byte (R/ W ) defines the operation to be
performed. When set to a 1 a read operation is selected, and when set to a 0 a write operation is selected.
Following the START condition, the DS1721 monitors the SDA bus checking the device type identifier
being transmitted. Upon receiving the 1001 code and appropriate device select bits, the slave device
outputs an acknowledge signal on the SDA line.
COMMAND SET
Data and control information is read from and written to the DS1721 in the format shown in Figure 6. To
write to the DS1721, the master will issue the slave address of the DS1721 and the R/ W bit will be set to
"0". After receiving an acknowledge, the bus master provides a command protocol. After receiving this
protocol, the DS1721 will issue an acknowledge and the master may send data to the DS1721. If the
DS1721 is to be read, the master must send the command protocol as before then issue a repeated START
condition and the control byte again, this time with the R/ W bit set to "1" to allow reading of the data
from the DS1721. The command set for the DS1721 as shown in Table 4 is as follows:
Read Temperature [AAh]
This command reads the last temperature conversion result from the Thermometer Register in the format
described in the “OPERATION-Measuring Temperature” section. If one’s application can accept
thermometer resolution of only 1.0°C, the master only must read the first data byte and follow with a
NACK and STOP. For higher resolution, both bytes must be read.
Access TH [A1h]
If R/ W is "0", this command writes to the TH register. After issuing this command, the next 2 bytes
written to the DS1721, in the format described for thermostat set-points, will set the high temperature
threshold for operation of the TOUT output. If R/ W is "1", the value stored in this register is read back.
Access TL [A2h]
If R/ W is "0", this command writes to the TL register. After issuing this command, the next 2 bytes
written to the DS1721, in the format described for thermostat set-points, will set the high temperature
threshold for operation of the TOUT output. If R/ W is "1", the value stored in this register is read back.
Access Config [ACh]
If R/ W is "0", this command writes to the configuration register. After issuing this command, the next
data byte value is to be written into the configuration register. If R/ W is "1", the next data byte read is the
value stored in the configuration register.
Start Convert T [51h]
This command begins a temperature conversion. No further data is required. In one-shot mode, the
temperature conversion will be performed and stored and then the DS1721 will remain idle. In continuous
mode, this command will initiate continuous conversions.
10 of 17
DS1721
Stop Convert T [22h]
This command stops temperature conversion. No further data is required. This command may be used to
halt a DS1721 in continuous conversion mode. After issuing this command, the current temperature
measurement will be completed, stored and the DS1721 will remain idle until a Start Convert T is issued
to resume conversions.
DS1721 COMMAND SET Table 4
INSTRUCTION
Access
Configuration
Access TH
Access TL
Start Convert T
Stop Convert T
Read
Temperature
DESCRIPTION
PROTOCOL
2-WIRE BUS DATA
AFTER ISSUING
PROTOCOL
REGISTER COMMANDS
Writes to/Reads from 8-bit
ACh
1 data byte
configuration/status register
Writes to/Reads from
A1h
1 or 2 data bytes
12-bit TH register
Writes to/Reads from
A2h
1 or 2 data bytes
12-bit TL register
CONVERSION COMMANDS
Initiates temperature
51h
idle
conversion
Terminates continuous
22h
idle
conversions
Reads 12-bit
AAh
Read 1 or 2 data bytes
Temperature register
NOTES
1
1, 3
1, 3
2
2
3
NOTES:
1. Data direction depends upon R/ W bit in the 2-wire control byte.
2. In continuous conversion mode, a Stop Convert T command will halt continuous conversion. To
restart, the Start Convert T command must be issued. In one-shot mode, a Start Convert T command
must be issued for every temperature reading desired.
3. If the user only desires 8-bit thermometer readings, the master need only read 1 data byte and follow
with a NACK and STOP. If higher resolution is required, 2 bytes must be read.
11 of 17
DS1721
SAMPLE COMMAND SEQUENCE Table 5
Example: After power-up, initiates a temperature conversion, bus master reads temperature
BUS MASTER DS1721 DATA (MSB COMMENTS
MODE
MODE
FIRST)
TX
RX
START
Bus Master initiates a START condition
TX
RX
<address, 0> Bus Master sends DS1721 address; R/ W = 0
RX
TX
ACK
DS1721 generates acknowledge bit
TX
RX
51h
Bus Master sends start convert T protocol
RX
TX
ACK
DS1721 generates acknowledge bit
TX
RX
START
Bus Master initiates a repeated START condition
TX
RX
<address, 0> Bus Master sends DS1721 address; R/ W = 0
RX
TX
ACK
DS1721 generates acknowledge bit
TX
RX
AAh
Bus Master sends read temperature protocol
RX
TX
ACK
DS1721 generates acknowledge bit
TX
RX
START
Bus Master initiates a repeated START condition
TX
RX
<address, 1> Bus Master sends DS1721 address; R/ W =1
RX
TX
ACK
DS1721 generates acknowledge bit
RX
TX
<1 data byte> DS1721 transmits MSB of temperature
TX
RX
ACK
Bus Master generates acknowledge bit
RX
TX
<1 data byte> DS1721 transmits LSB of temperature
12 of 17
DS1721
SAMPLE COMMAND SEQUENCE Table 6
Example: Bus master programs the DS1721 for 11-bit conversions in the continuous mode with an active
low state for the thermostat output. It then programs TH=50°C and TL=45°C and starts temperature
conversions.
BUS MASTER DS1721 DATA (MSB COMMENTS
MODE
MODE
FIRST)
TX
RX
START
Bus Master initiates a START condition
TX
RX
<address, 0> Bus Master sends DS1721 address; R/ W = 0
RX
TX
ACK
DS1721 generates acknowledge bit
TX
RX
ACh
Bus Master sends access configuration protocol
RX
TX
ACK
DS1721 generates acknowledge bit
TX
RX
08h
Bus Master programs configuration register as
described above. This will also clear thermostat
flags
RX
TX
ACK
DS1721 generates acknowledge bit
TX
RX
START
TX
RX
TX
RX
TX
RX
TX
RX
RX
TX
RX
TX
RX
TX
RX
TX
<address, 0>
ACK
A1h
ACK
32h
ACK
00h
ACK
TX
RX
START
TX
RX
TX
RX
TX
RX
TX
RX
RX
TX
RX
TX
RX
TX
RX
TX
<address, 0>
ACK
A2h
ACK
2Dh
ACK
00h
ACK
TX
RX
START
TX
RX
TX
RX
TX
RX
TX
RX
TX
RX
<address, 0>
ACK
51h
ACK
STOP
Bus Master Initiates a REPEATED START
condition
Bus Master sends DS1721 address; R/ W = 0
DS1721 generates acknowledge bit
Bus Master sends access TH protocol
DS1721 generates acknowledge bit
Bus Master writes MSB of TH (50°C)
DS1721 generates acknowledge bit
Bus Master writes LSB of TH (50°C)
DS1721 generates acknowledge bit
Bus Master initiates a REPEATED START
condition
Bus Master sends DS1721 address; R/ W = 0
DS1721 generates acknowledge bit
Bus Master sends access TL protocol
DS1721 generates acknowledge bit
Bus Master writes MSB of TL (45°C)
DS1721 generates acknowledge bit
Bus Master writes LSB of TL (45°C)
DS1721 generates acknowledge bit
Bus Master initiates a REPEATED START
condition
Bus Master sends DS1721 address; R/ W = 0
DS1721 generates acknowledge bit
Bus Master sends start convert protocol
DS1721 generates acknowledge bit
Bus Master initiates STOP condition
13 of 17
DS1721
ABSOLUTE MAXIMUM RATINGS*
Voltage on VDD, Relative to Ground
Voltage on any other pin, Related to Ground
Operating Temperature
Storage Temperature
Soldering Temperature
-0.3V to +6.0V
-0.3V to +6.0V
-55°C to +125°C
-55°C to +125°C
260°C for 10 seconds
* This is a stress rating only and functional operation of the device at these or any other conditions
above those indicated in the operation sections of this specification is not implied. Exposure to
absolute maximum rating conditions for extended periods of time may affect reliability.
RECOMMENDED DC OPERATING CONDITIONS
(-55°C to +125°C; 2.7V £ VDD £ 5.5V)
PARAMETER
Supply Voltage
SYMBOL
VDD
CONDITION
DC ELECTRICAL CHARACTERISTICS
PARAMETER
SYMBOL
Input Logic High
VIH
Input Logic Low
VIL
SDA Output Logic
Low Voltage
TOUT Output Logic
Voltage
Input Current Each
I/O Pin
I/O Capacitance
Standby Current
Active Current
VOL1
VOL2
VOH
VOL
CI/O
IDD1
IDD
CONDITION
MIN
2.7
Temperature
Conversions,
-55°C to +85°C
+85°C to +125°C
Communication
only
EEPROM Write
14 of 17
MAX
5.5
UNITS
V
NOTES
1
(-55°C to +125°C; 2.7V £ VDD £ 5.5V)
MIN
0.7
VDD
MAX
VDD
+0.3
0.3
VDD
UNITS
NOTES
V
1
V
1
0
0.4
V
1
0
0.6
V
1
V
1
0.4
V
1
+10
µA
2
10
0.8
pF
µA
3, 4
µA
3, 4
110
µA
3, 4
400
µA
3,4
-0.5
3 mA sink
current
6 mA sink
current
1 mA source
current
4 mA sink
current
0.4V £ VI/O
£ 0.9 VDD
TYP
TYP
2.4
-10
1000
1250
DS1721
DC ELECTRICAL CHARACTERISTICS:
DIGITAL THERMOMETER
PARAMETER
DS1721
Thermometer Error
SYMBOL
TERR
CONDITION
-10°C to +85°C,
3.0V≤VDD≤5.5V
-10°C to +85°C,
2.7V≤VDD<3.0V
-55°C to +125°C
Resolution
Conversion Time
tCONVT
SYMBOL
TYP
9-bit
Conversions
10-bit
Conversions
11-bit
Conversions
12-bit
Conversions
MAX
UNITS
±1.0
°C
±1.5
°C
±2.0
12
°C
bits
187.5
ms
375
750
(-55°C to +125°C; VDD=2.7V to 5.5V)
MIN
0
0
tBUF
Fast Mode
Standard Mode
1.3
4.7
µs
tHD:STA
Fast Mode
Standard Mode
0.6
4.0
µs
Fast Mode
Standard Mode
Fast Mode
Standard Mode
1.3
4.7
0.6
4.0
Fast Mode
Standard Mode
0.6
4.7
Fast Mode
Standard Mode
Fast Mode
Standard Mode
0
0
100
250
tR
Fast Mode
Standard Mode
20+0.1
CB
tF
Fast Mode
Standard Mode
20+0.1
CB
fSCL
tLOW
tHIGH
tSU:STA
tHD:DAT
Data Set-up Time
tSU:DAT
tSU:STO
Fast Mode
Standard Mode
15 of 17
NOTES
93.75
CONDITION
Fast Mode
Standard Mode
Data Hold Time
Rise Time of both
SDA and SCL
Signals
Fall Time of both
SDA and SCL
Signals
Set-up time for
STOP Condition
MIN
9
AC ELECTRICAL CHARACTERISTICS:
2-WIRE INTERFACE
PARAMETER
SCL Clock
Frequency
Bus Free Time
Between a STOP
and START
Condition
Hold Time
(Repeated) START
Condition
Low Period of
SCL Clock
High Period of
SCL Clock
Setup Time for a
Repeated START
Condition
(-55°C to +125°C; 2.7V £ VDD £ 5.5V)
0.6
4.0
TYP
MAX
400
100
UNITS
NOTES
KHz
5
µs
µs
µs
0.9
µs
6
ns
7
300
1000
ns
7
300
1000
ns
8
µs
DS1721
Capacitive Load for
each Bus Line
Input Capacitance
Cb
400
CI
5
pF
8
pF
NOTES:
1. All voltages are referenced to ground.
2. I/O pins of fast mode devices must not obstruct the SDA and SCL lines if VDD is switched off.
3. IDD specified with TOUT pin open.
4. IDD specified with VDD at 5.0V and SDA,SCL = 5.0V, 0°C to 70°C.
5. After this period, the first clock pulse is generated.
6. The maximum tHD:DAT has only to be met if the device does not stretch the LOW period (tLOW) of the
SCL signal.
7. A fast mode device can be used in a standard mode system, but the requirement tSU:DAT >250 ns must
then be met. This will automatically be the case if the device does not stretch the LOW period of the
SCL signal. If such a device does stretch the LOW period of the SCL signal, it must output the next
data bit to the SDA line tR MAX+tSU:DAT 1000+250 = 1250 ns before the SCL line is released.
8. Cb - total capacitance of one bus line in pF.
TIMING DIAGRAMS Figure 7
16 of 17
DS1721
TYPICAL DS1721 THERMOMETER PERFORMANCE CURVE Figure 8
DS1721
17 of 17