Single Junction Gull Wing Circulator 950 MHz—956 MHz MAFRIN0453 Version 2 Features • • • • Designed for RFID market 22dB Isolation typical 0.25dB Insertion Loss Low cost package Description This circulator is designed specifically for RFID applications and features high reliability performance at a low cost. It is in a low cost package ideally suited for high volume manufacturing. M/A Com is one of the largest suppliers of isolator and circulators in the world. Electrical Specifications: TA = +25°C, Z0 = 50 Ohms Parameter Test Conditions Frequency Range Over Top Units Min MHz 950 1 Typ Max 956 Insertion Loss 950 MHz—956 MHz, over Top dB 0.21 Isolation 950 MHz—956 MHz, over Top dB 23.0 29.0 Return Loss 950 MHz—956 MHz, all ports, over Top dB 23.0 28.0 Circulation Over Top 0.25 CW 1. See “Absolute Maximum Ratings” for Top. Absolute Maximum Ratings Parameter Absolute Maximum Forward Power 100 Watts Operating Temperature -10°C to +85°C Storage Temperature -40°C to +100°C 1. Operation of this device above any one of these parameters may cause permanent damage. 1 M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information. • North America Tel: 800.366.2266 / Fax: 978.366.2266 • Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 • Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macom.com for additional data sheets and product information. Single Junction Gull Wing Circulator 950 MHz—956 MHz MAFRIN0453 Version 2 Environmental Specifications Ordering Information Part Number Packaging MAFRIN0453 Tray Devices are designed to function after exposure to the shock, vibration, thermal shock and moisture conditions typically encountered in base station and other infrastructure environments. S-Parameters S-parameters are available on the M/A Com website at: S-Parameter Isolation (S12) Insertion Loss (S21) +25 C -10 C +85 C +25 C 0.00 -22 -0.10 -23 +85 C -24 dB dB -0.20 -0.30 -25 -26 Frequency (MHz) 956 955 954 953 953 952 950 951 -27 956 955 954 953 953 952 951 950 -0.40 Frequency (MHz) Return Loss (S11) Return Loss (S22) +25 C -10 C +85 C +25 C -20 -22 -24 -26 -28 -30 -32 -34 -10 C +85 C -20 dB -22 -24 -26 -28 Frequency (MHz) 956 955 954 953 953 952 951 950 956 955 954 953 953 952 951 -30 950 dB -10 C Frequency (MHz) 2 M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information. • North America Tel: 800.366.2266 / Fax: 978.366.2266 • Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 • Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macom.com for additional data sheets and product information. Single Junction Gull Wing Circulator 950 MHz—956 MHz Recommended PCB Layout 1. Dimensions in mm. 2. Tolerances: ± 0.2 mm unless otherwise noted. 3. Use multiple plated thru holes in ground area under the housing. MAFRIN0453 Version 2 Outline Drawing 1. 2. 3. 4. 5. Dimensions in mm. Tolerances: ± 0.3 mm unless otherwise noted. Housing: Cold Rolled Steel with SnPb 90/10 plating. Cover: CRS with SnPb 90/10 plating. Leads: Copper. 3 M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information. • North America Tel: 800.366.2266 / Fax: 978.366.2266 • Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 • Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macom.com for additional data sheets and product information.