MAXIM MAX17058_13

EVALUATION KIT AVAILABLE
MAX17058/MAX17059
1-Cell /2-Cell Li+ ModelGauge ICs
General Description
The MAX17058/MAX17059 ICs are tiny fuel gauges
for lithium-ion (Li+) batteries in handheld and portable
equipment. The MAX17058 operates with a single Li+
cell and the MAX17059 with two Li+ cells in series.
The ICs use the sophisticated Li+ battery-modeling
algorithm ModelGaugeK to track the battery relative
state-of-charge (SOC) continuously over a widely varying
charge/discharge conditions. The ModelGauge algorithm eliminates current-sense resistor and battery-learn
cycles required by other fuel gauges. Temperature
compensation is implemented using the system microcontroller.
On battery insertion, the ICs debounce initial voltage
measurements to improve the initial SOC estimate,
allowing them to be located on system side. SOC and
voltage information is accessed using the I2C interface.
The ICs are available in a tiny 0.9mm x 1.7mm, 8-bump
wafer-level package (WLP) or a 2mm x 2mm, 8-pin TDFN
package.
Applications
Wireless Handsets
Smartphones/PDAs
Features and Benefits
SMAX17058: 1 Cell, MAX17059: 2 Cells
SPrecision ±7.5mV/Cell Voltage Measurement
SModelGauge Algorithm
Provides Accurate State-of-Charge
Compensates for Temperature/Load Variation
Does Not Accumulate Errors, Unlike Coulomb
Counters
Eliminates Learning
Eliminates Current-Sense Resistor
SLow Quiescent Current: 23µA
SBattery-Insertion Debounce

Best of 16 Samples Estimates Initial SOC
SProgrammable Reset for Battery Swap

2.28V to 3.48V Range
SLow SOC Alert Indicator
SI2C Interface
Ordering Information appears at end of data sheet.
Simplified Operating Circuit
Tablets and Handheld Computers
Portable Game Players
e-Readers
MAX17058
Digital Still and Video Cameras
Portable Medical Equipment
ONLY ONE
EXTERNAL
COMPONENT
VDD
ALRT
CELL
SDA
CTG
SCL
GND
QSTRT
SYSTEM
µP
ModelGauge is a trademark of Maxim Integrated Products, Inc.
For pricing, delivery, and ordering information, please contact Maxim Direct
at 1-888-629-4642, or visit Maxim’s website at www.maximintegrated.com.
19-6172; Rev 4; 6/13
MAX17058/MAX17059
1-Cell /2-Cell Li+ ModelGauge ICs
ABSOLUTE MAXIMUM RATINGS
CELL to GND..........................................................-0.3V to +12V
All Pins Excluding CELL to GND.............................-0.3V to +6V
Continuous Sink Current, SDA, ALRT.................................20mA
Operating Temperature Range........................... -40NC to +85NC
Storage Temperature Range............................. -55NC to +125NC
Lead Temperature (TDFN only) (soldering, 10s) ............+300NC
Soldering Temperature (reflow).......................................+260NC
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(2.5V < VDD < 4.5V, -20NC < TA < +70NC, unless otherwise noted. Typical values are at TA = +25NC.) (Note 1)
PARAMETER
Supply Voltage
Fuel-Gauge SOC Reset
(VRESET Register)
Data I/O Pins
Supply Current
Time Base Accuracy
SYMBOL
VDD
VRST
SCL, SDA,
ALRT
IDD0
MIN
(Note 2)
Configuration range, in 40mV steps
Trimmed at 3V
2.85
(Note 2)
-0.3
IDD1
Sleep mode, TA < +50NC
Active mode
tERR
Active mode (Note 3)
ADC Sample Period
Voltage Error
CONDITIONS
MAX
UNITS
2.5
4.5
V
2.28
3.48
V
3.15
V
+5.5
V
-3.5
Active mode
VERR
3.0
0.5
2
23
40
Q1
+3.5
250
-7.5
+7.5
-20NC < TA < +70NC
-20
+20
MAX17058: VDD pin
2.5
5
MAX17059: CELL pin
5
10
1.25
Voltage-Measurement Range
SDA, SCL, QSTRT Input Logic-High
VIH
SDA, SCL, QSTRT Input Logic-Low
VIL
SDA, ALRT Output Logic-Low
VOL
IOL = 4mA
SDA, SCL Bus Low-Detection
Current
IPD
VSDA = VSCL = 0.4V (Note 5)
tSLEEP
%
mV/cell
mV/cell
1.4
(Note 6)
FA
ms
VCELL = 3.6V, TA = +25NC (Note 4)
Voltage-Measurement Resolution
Bus Low-Detection Timeout
TYP
V
V
0.2
1.75
0.5
V
0.4
V
0.4
FA
2.5
s
MAX
UNITS
400
kHz
ELECTRICAL CHARACTERISTICS (I2C INTERFACE)
(2.5V < VDD < 4.5V, -20NC < TA < +70NC, unless otherwise noted.) (Note 1)
PARAMETER
SYMBOL
SCL Clock Frequency
fSCL
Bus Free Time Between a STOP and
START Condition
tBUF
START Condition (Repeated) Hold
Time
Low Period of SCL Clock
Maxim Integrated
tHD:STA
tLOW
CONDITIONS
(Note 7)
(Note 8)
MIN
0
TYP
1.3
Fs
0.6
Fs
1.3
Fs
2
MAX17058/MAX17059
1-Cell /2-Cell Li+ ModelGauge ICs
ELECTRICAL CHARACTERISTICS (I2C INTERFACE) (continued)
(2.5V < VDD < 4.5V, -20NC < TA < +70NC, unless otherwise noted.) (Note 1)
PARAMETER
SYMBOL
High Period of SCL Clock
CONDITIONS
MIN
TYP
MAX
UNITS
tHIGH
0.6
Fs
Setup Time for a Repeated START
Condition
tSU:STA
0.6
Fs
Data Hold Time
tHD:DAT
(Notes 9, 10)
Data Setup Time
tSU:DAT
(Note 9)
0
0.9
100
Fs
ns
Rise Time of Both SDA and SCL
Signals
tR
20 + 0.1CB
300
ns
Fall Time of Both SDA and SCL
Signals
tF
20 + 0.1CB
300
ns
Setup Time for STOP Condition
tSU:STO
0.6
Spike Pulse Widths Suppressed by
Input Filter
tSP
(Note 11)
Capacitive Load for Each Bus Line
CB
(Note 12)
SCL, SDA Input Capacitance
Fs
0.6
50
ns
400
pF
60
pF
CB,IN
Note 1: Specifications are tested 100% at TA = +25NC. Limits over the operating range are guaranteed by design and
characterization.
Note 2: All voltages are referenced to GND.
Note 3: Test is performed on unmounted/unsoldered ports.
Note 4: The voltage is trimmed and verified with 16x averaging.
Note 5: This current is always present.
Note 6: The IC enters sleep mode after SCL < VIL and SDA < VIL for longer than 2.5s.
Note 7: Timing must be fast enough to prevent the IC from entering sleep mode due to bus low for period > tSLEEP.
Note 8:fSCL must meet the minimum clock low time plus the rise/fall times.
Note 9: The maximum tHD:DAT has to be met only if the device does not stretch the low period (tLOW) of the SCL signal.
Note 10: This device internally provides a hold time of at least 100ns for the SDA signal (referred to the VIH,MIN of the SCL signal)
to bridge the undefined region of the falling edge of SCL.
Note 11: Filters on SDA and SCL suppress noise spikes at the input buffers and delay the sampling instance.
Note 12:CB is total capacitance of one bus line in pF.
SDA
tF
tLOW
tSU:DAT
tR
tSP
tF
tR
tBUF
tHD:STA
SCL
tHD:STA
S
tHD:DAT
tSU:STA
tSU:STO
Sr
P
S
Figure 1. I2C Bus Timing Diagram
Maxim Integrated
3
MAX17058/MAX17059
1-Cell /2-Cell Li+ ModelGauge ICs
Typical Operating Characteristics
(TA = +25NC, battery is Sanyo UF504553F, unless otherwise noted.)
QUIESCENT CURRENT vs. SUPPLY
VOLTAGE (ACTIVE MODE)
VOLTAGE ADC ERROR vs. TEMPERATURE
25
20
TA = +25°C
15
TA = -20°C
10
MAX17058 toc02
TA = +70°C
VOLTAGE ADC ERROR (mV/CELL)
15
10
VCELL = 4.5V
5
0
-5
VCELL = 3.6V
-10
VCELL = 2.5V
-15
5
-20
0
2.5
3.0
3.5
-5
-20
4.5
4.0
VCELL (V)
SOC ACCURACY TA = 0°C
REFERENCE SOC
MODELGAUGE SOC
REFERENCE SOC
40
55
70
MODELGAUGE
ERROR
MAX17058 toc04
10
100
75
5
75
5
50
0
50
0
25
-5
25
-5
-10
0
0
0
2
4
6
8
SOC (%)
ERROR (%)
SOC (%)
25
SOC ACCURACY TA = +20°C
ERROR
MAX17058 toc03
100
10
TEMPERATURE (°C)
10
10
ERROR (%)
QUIESCENT CURRENT (µA)
35
30
20
MAX17058 toc01
40
-10
0
-2
TIME (Hr)
2
4
6
8
10
TIME (Hr)
MODELGAUGE SOC
SOC (%)
ERROR
MAX17058 toc05
100
10
75
5
50
0
25
-5
0
ERROR (%)
SOC ACCURACY TA = +40°C
REFERENCE SOC
-10
0
2
4
6
8
10
TIME (Hr)
Maxim Integrated
4
MAX17058/MAX17059
1-Cell /2-Cell Li+ ModelGauge ICs
Typical Operating Characteristics (continued)
(TA = +25NC, battery is Sanyo UF504553F, unless otherwise noted.)
MODELGAUGE SOC
MAX17058 toc06
REFERENCE SOC
MODELGAUGE SOC
75
5
75
5
50
0
50
0
25
-5
25
-5
-10
0
0
20
40
60
80
SOC (%)
100
0
2
4
NO ERROR ACCUMULATED AFTER
100 HOURS
10
MAX17058 toc09
VCELL
75
5
50
0
25
-5
0
-10
97
99
101
TIME (Hr)
Maxim Integrated
103
105
OCV
0V
0V
0V
0A
95
10
8
BATTERY-INSERTION DEBOUNCE/
OCV ACQUISITION
ERROR
ERROR (%)
MODELGAUGE SOC
MAX17058 toc08
100
6
TIME (Hr)
ZIGZAG PATTERN SOC ACCURACY (3/3)
REFERENCE SOC
10
-10
0
100
TIME (Hr)
SOC (%)
ERROR
MAX17058 toc07
10
ERROR (%)
SOC (%)
100
ZIGZAG PATTERN SOC ACCURACY (2/3)
ERROR
ERROR (%)
ZIGZAG PATTERN SOC ACCURACY (1/3)
REFERENCE SOC
DEBOUNCE
BEGINS
DEBOUNCE
COMPLETED
4ms/div
5
MAX17058/MAX17059
1-Cell /2-Cell Li+ ModelGauge ICs
Pin/Bump Configurations
TOP VIEW
(PAD SIDE DOWN)
TOP VIEW
(BUMP SIDE DOWN)
SCL
QSTRT
ALRT
8
7
6
5
MAX17058
MAX17059
+
SDA
CTG
CELL
VDD
GND
A1
A2
A3
A4
SDA
SCL
QSTRT
ALRT
B1
B2
B3
B4
MAX17058
MAX17059
EP
+
1
2
3
4
CTG
CELL
VDD
GND
WLP
TDFN
Pin/Bump Description
PIN/BUMP
NAME
FUNCTION
TDFN
WLP
1
A1
CTG
Connect to GND
1
A2
CELL
Connect to Positive Battery Terminal.
MAX17058: Not connected internally.
MAX17059: Voltage-sense input.
3
A3
VDD
Power-Supply Input. Bypass with 0.1FF to GND.
MAX17058: Voltage-sense input. Connect to a positive battery terminal.
MAX17059: Connect to a regulated power-supply voltage.
4
A4
GND
Ground. Connect to a negative battery terminal.
5
B4
ALRT
Open-Drain, Active-Low Alert Output. Optionally connect to the interrupt input of the
system microcontroller.
6
B3
QSTRT
7
B2
SCL
I2C Clock Input. SCL has an internal pulldown (IPD) for sensing disconnection.
8
B1
SDA
Open-Drain I2C Data Input/Output. SDA has an internal pulldown (IPD) for sensing
disconnection.
—
—
EP
Maxim Integrated
Quick-Start Input. Resets state-of-charge calculation. Connect to GND if not used.
Exposed Pad (TDFN Only). Connect to GND.
6
MAX17058/MAX17059
1-Cell /2-Cell Li+ ModelGauge ICs
ModelGauge Theory of Operation
The MAX17058/MAX17059 ICs simulate the internal, nonlinear dynamics of a Li+ battery to determine its state of
charge (SOC). The sophisticated battery model considers impedance and the slow rate of chemical reactions in
the battery (Figure 2).
The ModelGauge algorithm performs best with a custom
model, obtained by characterizing the battery at multiple
discharge currents and temperatures to precisely model
it. Contact Maxim if you need a custom model. At poweron reset (POR), the ICs have a preloaded ROM model
that performs well for some batteries.
Fuel-Gauge Performance
In coulomb counter-based fuel gauges, SOC drifts
because offset error in the current-sense ADC measurement accumulates over time. Instantaneous error can be
very small, but never precisely zero. Error accumulates
over time in such systems (typically 0.5%–2% per day)
and requires periodic corrections. Some algorithms correct drift using occasional events, and until such an event
occurs the algorithm’s error is boundless:
• Reaching predefined SOC levels near full or empty
• Measuring the relaxed battery voltage after a long
period of inactivity
• Completing a full charge/discharge cycle
The ModelGauge algorithm requires no correction events
because it uses only voltage, which is stable over time. As
the SOC accuracy without full/empty/relax shows the
algorithm remains accurate despite the absence of any
of the above events; it neither drifts nor accumulates
error over time.
To correctly measure performance of a fuel gauge as
experienced by end-users, exercise the battery dynamically; accuracy cannot be fully determined from only
simple cycles.
Battery Voltage and State-of-Charge
The open-circuit voltage (OCV) of a Li+ battery uniquely
determines its SOC; one SOC can have only one value of
OCV. In contrast, a given VCELL can occur at many different values of OCV because VCELL is a function of time,
OCV, load, temperature, age, and impedance, etc.; one
value of OCV can have many values of VCELL. Therefore,
one SOC can have many values of VCELL, so VCELL cannot uniquely determine SOC.
Figure 3 shows that VCELL = 3.81V occurs at 2%, 50%,
and 72% SOC.
Even the use of sophisticated tables to consider both
voltage and load results in significant error due to the
load transients typically experienced in a system. During
charging or discharging, and for approximately 30min
after, VCELL and OCV differ substantially, and VCELL has
been affected by the preceding hours of battery activity.
ModelGauge uses voltage comprehensively by using
voltage measured over a long period of time.
VDD
VOLTAGE
REFERENCE
CELL
GND
IC
GROUND
ALRT
3.6V
3.4V
3.81V = 50%
80%
QSTRT
SOC
ADC (VCELL)
3.8V
3.81V = 72%
3.81V = 2%
100%
STATE
MACHINE
(SOC)
4.0V
3.81V
TIME BASE
(32kHz)
BIAS
4.2V
VCELL
MAX17058
MAX17059
60%
VCELL
Detailed Description
3.2V
SOC
40%
20%
I2C
INTERFACE
SDA
SCL
0%
0
1
2
3
4
5
6
7
8
TIME (Hr)
Figure 2. Block Diagram
Maxim Integrated
Figure 3. Instantaneous Voltage Does Not Translate Directly to
SOC
7
MAX17058/MAX17059
1-Cell /2-Cell Li+ ModelGauge ICs
Temperature Compensation
For best performance, the host microcontroller must
measure battery temperature periodically, and compensate
the RCOMP ModelGauge parameter accordingly, at least
once per minute. Each custom model defines constants
RCOMP0, TempCEach custom model defines constants
RCOMP0 (default is 0x97), TempCoUp (default is -0.5),
and TempCoDown (default is -5.0). To calculate the new
value of CONFIG.RCOMP:
// T is battery temperature (degrees Celsius)
if (T > 20) {
RCOMP = RCOMP0 + (T - 20) x TempCoUp;
}
else {
RCOMP = RCMOP0 + (T - 20) x TempCoDown;
}
60
C/3 LOAD
CAPACITY LOST (%)
50
40
30
20
10
C/10 LOAD
0
3.0
3.1
3.2
3.3
3.4
3.5
TARGET EMPTY VOLTAGE (V)
Figure 4. Increasing Empty Voltage Reduces Battery Capacity
Impact of Empty-Voltage Selection
Most applications have a minimum operating voltage
below which the system immediately powers off (empty
voltage). When characterizing the battery to create a custom model, choose empty voltage carefully. As shown in
Figure 4, capacity unavailable to the system increases at
an accelerating rate as empty voltage increases.
To ensure a controlled shutdown, consider including
operating margin into the fuel gauge based
on some low threshold of SOC, for example,
shutting down at 3% or 5%. This utilizes the battery
more effectively than adding error margin to empty voltage.
Battery Insertion
When the battery is first inserted into the system, the
fuel-gauge IC has no previous knowledge about the
battery’s SOC. Assuming that the battery is relaxed, the
IC translates its first VCELL measurement into the best
initial estimate of SOC. Initial error caused by the battery
not being in a relaxed state diminishes over time, regardless of loading following this initial conversion. While the
SOC estimated by the coulomb counter diverges, the
ModelGauge SOC converges, correcting error automatically as illustrated in Figure 5; initial error has no longlasting impact.
Battery-Insertion Debounce
Any time the IC powers on or resets (see the VRESET
Register (0x18) section), it estimates that OCV is the
maximum of 16 VCELL samples (1ms each, full 12-bit
resolution). OCV is ready 17ms after battery insertion,
and SOC is ready 175ms after that.
LONGER BATTERY RELAXATION
IMPROVES INITIAL ACCURACY
MODELGAUGE HEALS ERROR
AUTOMATICALLY OVER TIME
45%
UNRELAXED ERROR
-10mV
-5%
VOLTAGE ERROR
-20mV
0.1
1
0%
10
100
-10%
1000
RELAXATION TIME BEFORE INSERTION (MINUTES)
30%
SOC
0%
0mV
SOC
SOC ERROR
SOC ERROR (%)
INITIAL VOLTAGE ERROR (mV)
RELAXED ERROR
REFERENCE SOC
RELAXED SOC
-5%
15%
UNRELAXED SOC
-10%
0
20
0%
40
60
80
TIME AFTER INSERTION (MINUTES)
Figure 5. ModelGauge Heals Error Automatically
Maxim Integrated
8
MAX17058/MAX17059
1-Cell /2-Cell Li+ ModelGauge ICs
Battery-Swap Detection
If VCELL falls below VRST then returns above VRST, the IC
quick-starts. This handles the battery swap; the SOC of
the previous battery doesn not affect that of the new one.
See the Quick-Start and VRESET Register (0x18) sections.
Figure 7 illustrates a waveform that could corrupt the
initial SOC. If the disturbance is severe, quick-start after
the inrush current has stopped and voltage has settled,
but before the system is fully powered. If issued too soon
or too late, a quick-start causes SOC error.
Quick-Start
Large inrush current might reduce VCELL longer than the
initial sampling period. Issue a quick-start so that VCELL
is nearest OCV during the 17ms following the command.
If the IC generates an erroneous initial SOC, the battery insertion and system power-up waveforms must
be examined to determine if a quick-start is necessary,
as well as the best time to execute the command. The
IC samples the maximum VCELL during the first 17ms
(see the Battery Insertion section). Unless VCELL is fully
relaxed, even the best sampled voltage can appear
greater or less than OCV. Therefore, quick-start must be
used cautiously.
Most systems should not use quick-start because the
ICs handle most startup problems transparently, such
as intermittent battery-terminal connection during insertion. If battery voltage stabilizes faster than 17ms, as
illustrated in Figure 6, then do not use quick-start.
The quick-start command restarts fuel-gauge calculations in the same manner as initial power-up of the IC.
If the system power-up sequence is so noisy that the initial
estimate of SOC has unacceptable error, the system
microcontroller might be able to reduce the error by
using quick-start. A quick-start is initiated by a rising
edge on the QSTRT pin, or by writing 1 to the quick-start
bit on the MODE register.
If the IC remains powered by a charger when the cell is
removed, then it continues to measure the charge voltage even though the cell is not present. When the cell is
reinserted, quick-start before the charger affects VCELL.
Power-On Reset (POR)
POR includes a quick-start, so only use it for when
a quick-start is safe (see the Quick-Start section).
This command restores all registers to their default
values. After this command, reload the custom model.
See the CMD Register (0xFE) section.
Alert Interrupt
The ICs can interrupt a system microcontroller when
SOC becomes low. See the CONFIG Register (0x0C)
and STATUS Register (0x1A) sections. When the alert is
triggered, the IC asserts the ALRT pin logic-low and sets
CONFIG.ALRT = 1. The ALRT pin remains logic-low until
the system writes CONFIG.ALRT = 0 to clear the alert.
The alert function is enabled by default and can occur
immediately upon power-up. Entering sleep mode does
not clear the ALRT bit or the ALRT pin.
VCELL
STEADY SYSTEM
LOAD BEGINS
VCELL
STEADY SYSTEM
LOAD BEGINS
VCELL HAS FULLY RELAXED
17ms
TIME
INITIAL SAMPLE DEBOUNCE WINDOW
Figure 6. Insertion Waveform Not Requiring Quick-Start
Command
Maxim Integrated
BEST TIME TO
QUICK-START
VCELL HAS
FULLY RELAXED
17ms
INITIAL SAMPLE
DEBOUNCE WINDOW
TIME
QUICK-START DURING
THIS TIME SPAN
Figure 7. Insertion Waveform Requiring Quick-Start Command
9
MAX17058/MAX17059
1-Cell /2-Cell Li+ ModelGauge ICs
Sleep Mode
Calculate the register’s value by multiplying the 16-bit
word by the register’s LSb value, as shown in Table 1.
In sleep mode, the IC halts all operations, reducing
current consumption (below 1FA). After exiting sleep
mode, the IC continues normal operation. In sleep mode,
the IC does not detect self-discharge. If the battery
changes state while the IC sleeps, the IC cannot detect
it, causing SOC error. Wake up the IC before charging
or discharging.
To enter sleep mode, either:
• Hold SDA and SCL logic-low for a period of tSLEEP. A
rising edge on SDA or SCL wakes up the IC.
VCELL Register (0x02)
The MAX17058 measures VCELL between the VDD and
GND pins. The MAX17059 measures VCELL between the
CELL and GND pins. The register value is the average of
four ADC conversions. The value updates every 250ms
in active mode.
SOC Register (0x04)
The ModelGauge algorithm calculates relative SOC,
automatically adapting to variation in battery size. The
upper byte least-significant bit has units of 1%. The
first update is available approximately 1s after POR.
Subsequent updates occur at variable intervals depending
on application conditions.
• Write CONFIG.SLEEP = 1. To wake up the IC, write
CONFIG.SLEEP = 0. Other communication does not
wake up the IC. POR wakes up the IC.
Register Summary
MODE Register (0x06)
All registers must be written and read as 16-bit words;
8-bit writes cause no effect. Any bits marked X (don’t
care) or read only must be written with the rest of the
register, but the value written is ignored by the IC. The
values read from don’t care bits are undefined.
The MODE register allows the system processor to send
special commands to the IC (see Figure 8).
• Quick-Start estimates SOC assuming OCV is equal
to immediate VCELL. Use with caution; see the QuickStart section.
Table 1. Register Summary
ADDRESS
REGISTER NAME
16-BIT LSb
0x02
VCELL
78.125 FV/cell
READ/WRITE
DEFAULT
ADC measurement of VCELL.
Battery state of charge.
0x04
SOC
1%/256
0x06
MODE
0x08
DESCRIPTION
R
—
R
—
—
Initiates quick-start.
W
0x0000
VERSION
—
IC production version.
R
0x0011
0x0C
CONFIG
—
Compensation to optimize performance, sleep
mode, alert indicators, and configuration.
R/W
0x971C
0x18
VRESET
—
Configures VCELL threshold below which the
IC resets itself.
R/W
0x96__
0x01__
0x1A
STATUS
—
Low SOC alert and reset indicators.
R/W
0x40 to 0x7F
TABLE
—
Configures the battery parameters.
W
—
0xFE
CMD
—
Sends POR command.
R/W
0xFFFF
MSB—ADDRESS 0x06
X
QuickStart
X
MSb
X
X
LSB—ADDRESS 0x07
X
X
X
X
LSb
MSb
X
X
X
X
X
X
X
LSb
Figure 8. MODE Register Format
Maxim Integrated
10
MAX17058/MAX17059
1-Cell /2-Cell Li+ ModelGauge ICs
31%, 00010b → 30%, 11111b → 1%). the POR value
of ATHD is 0x1C or 4%. The alert occurs only on a
falling edge past this threshold.
VERSION Register (0x08)
The value of this read-only register indicates the production
version of the IC (0x0011).
CONFIG Register (0x0C)
See Figure 9.
• RCOMP compensates the model for different lithium
chemistries. The system must adjust RCOMP periodically (see the Temperature Compensation section).
The POR value of RCOMP is 0x97.
• SLEEP forces the IC in or out of sleep mode. Writing
1 forces the IC to enter sleep mode, and 0 forces
the IC to exit. The POR value of SLEEP is 0. Use with
caution (see the Sleep Mode section).
VRESET Register (0x18)
See Figure 10.
• VRESET[7:1] adjusts a fast analog comparator and
a slower digital ADC threshold to detect battery
removal and reinsertion. Set between 2.28V and
3.48V, 40mV to 80mV below the application’s empty
voltage according to the desired reset threshold for
your application.
If the comparator is enabled, the IC resets 1ms after
VCELL rises above the threshold. Otherwise, the IC
resets 250ms after the VCELL register rises above the
threshold.
• ALRT (alert status bit) is set by the IC when SOC
becomes low. When this bit is set, the ALRT pin
asserts low. Clear to deassert the ALRT pin. The POR
value is 0 (see the Alert Interrupt section).
See Figure 11.
• ATHD (empty alert threshold) sets the SOC threshold,
where an interrupt is generated on the ALRT pin and
can be programmed from 1% up to 32%. The value
is (32 - ATHD)% (e.g., 00000b → 32% → 00001b →
U RI (reset indicator) is set when the device powers up.
Any time this bit is set, the IC is not configured, so the
custom model and any other configuration must be
immediately reloaded and the bit should be cleared.
STATUS Register (0x1A)
MSB (RCOMP)—ADDRESS 0x0C
LSB—ADDRESS 0x0D
RCOMP RCOMP RCOMP RCOMP RCOMP RCOMP RCOMP RCOMP
7
6
5
4
3
2
1
0
SLEEP
MSb
MSb
LSb
X
ALRT
ATHD
LSb
Figure 9. CONFIG Register Format
MSB (VRESET)—ADDRESS 0x18
26
25
24
23
22
21
20
MSb
LSB (ID)—ADDRESS 0x19
Dis
ID7
LSb
MSb
ID6
ID5
ID4
ID3
ID2
ID1
ID0
LSb
VRESET 20 Units: 40mV
Figure 10. VRESET Register Format
MSB—ADDRESS 0x1A
X
X
X
HD
MSb
X
X
LSB—ADDRESS 0x1B
X
RI
X
LSb
MSb
X
X
X
X
X
X
X
LSb
Figure 11. STATUS Register Format
Maxim Integrated
11
MAX17058/MAX17059
1-Cell /2-Cell Li+ ModelGauge ICs
TABLE Registers (0x40 to 0x7F)
Contact Maxim for details on how to configure these
registers. The default value is appropriate for some
Li+ batteries.
To unlock the TABLE registers, write 0x57 to address
0x3F, and 0x4A to address 0x3E. While the TABLE is
unlocked, no ModelGauge registers are updated, so
relock as soon as possible by writing 0x00 to address
0x3F, and 0x00 to address 0x3E.
CMD Register (0xFE)
Writing a value of 0x5400 to this register causes the device
to completely reset as if power had been removed. Use
with caution (see the Power-On Reset (POR) section).
The reset occurs when the last bit has been clocked
in. The IC does not respond with an I2C ACK after this
command sequence.
Application Examples
The ICs have a variety of configurations, depending on
the application. Table 2 shows the most common system
configurations and the proper pin connections for each.
In all cases, the system must provide pullup circuits for
ALRT (if used), SDA, and SCL.
Figure 12 shows an example application for a 1S cell
pack. In this example, the ALRT pin is connected to
the microcontroller’s interrupt input so the MAX17058
indicates when the battery becomes low. The QSTRT pin
is unused in this application and is connected to GND.
Figure 13 shows a MAX17059 example application using
a 2S cell pack. The MAX17059 is mounted on the system side and powered from a 3.3V supply generated
by the system. The CELL pin is still connected directly
to PACK+.
Table 2. Possible Application Configurations
SYSTEM CONFIGURATION
IC
VDD
ALRT
QSTRT
1S pack-side location
MAX17058
Power directly from battery
Leave unconnected
Connect to GND
1S host-side location
MAX17058
Power directly from battery
Leave unconnected
Connect to GND
Connect to GND
1S host-side location,
low-cell interrupt
MAX17058
Power directly from battery
Connect to system
interrupt
1S host-side location,
hardware quick-start
MAX17058
Power directly from battery
Leave unconnected
Connect to rising-edge
reset signal
2S pack-side location
MAX17059
Power from +2.5V to +4.5V
LDO in pack
Leave unconnected
Connect to GND
2S host-side location
MAX17059
Power from +2.5V to +4.5V
LDO or PMIC
Leave unconnected
Connect to GND
2S host-side location,
low-cell interrupt
MAX17059
Power from +2.5V to +4.5V
LDO or PMIC
Connect to system
interrupt
Connect to GND
2S host-side location,
hardware quick-start
MAX17059
Power from +2.5V to +4.5V
LDO or PMIC
Leave unconnected
Connect to rising-edge
reset signal
2.5V TO 4.5V OUTPUT FROM SYSTEM
BATTERY PACK
MAX17058
0.1µF
PROTECTION
VDD
ALRT
CELL
SDA
CTG
SCL
GND
SYSTEM µP
BATTERY PACK
INTERRUPT
I2C BUS
MASTER
0.1µF
QSTRT
PROTECTION
NOTE: SYSTEM REQUIRED TO PROVIDE PULLUP CIRCUITS FOR ALRT, SDA, AND SCL.
Figure 12. MAX17058 Application Circuit (1S Cell Pack)
Maxim Integrated
MAX17059
VDD
ALRT
CELL
SDA
CTG
SCL
GND
QSTRT
SYSTEM µP
INTERRUPT
I2C BUS
MASTER
NOTE: SYSTEM REQUIRED TO PROVIDE PULLUP CIRCUITS FOR ALRT, SDA, AND SCL.
Figure 13. MAX17059 Application Circuit (2S Cell Pack)
12
MAX17058/MAX17059
1-Cell /2-Cell Li+ ModelGauge ICs
I2C Bus System
The I2C bus system supports operation as a slave-only
device in a single or multislave, and single or multimaster
system. Slave devices can share the bus by uniquely
setting the 7-bit slave address. The I2C interface consists of a serial-data line (SDA) and serialclock line
(SCL). SDA and SCL provide bidirectional communication between the ICs slave device and a master device
at speeds up to 400kHz. The ICs’ SDA pin operates
bidirectionally; that is, when the ICs receive data, SDA
operates as an input, and when the ICs return data, SDA
operates as an open-drain output, with the host system
providing a resistive pullup. The ICs always operate as
a slave device, receiving and transmitting data under
the control of a master device. The master initiates all
transactions on the bus and generates the SCL signal, as
well as the START and STOP bits, which begin and end
each transaction.
Bit Transfer
One data bit is transferred during each SCL clock cycle,
with the cycle defined by SCL transitioning low-to-high
and then high-to-low. The SDA logic level must remain
stable during the high period of the SCL clock pulse.
Any change in SDA when SCL is high is interpreted as a
START or STOP control signal.
Bus Idle
The bus is defined to be idle, or not busy, when no
master device has control. Both SDA and SCL remain
high when the bus is idle. The STOP condition is the
proper method to return the bus to the idle state.
START and STOP Conditions
The master initiates transactions with a START condition
(S) by forcing a high-to-low transition on SDA while SCL
is high. The master terminates a transaction with a STOP
condition (P), a low-to-high transition on SDA while SCL
is high. A Repeated START condition (Sr) can be used
in place of a STOP then START sequence to terminate
one transaction and begin another without returning the
bus to the idle state. In multimaster systems, a Repeated
START allows the master to retain control of the bus. The
START and STOP conditions are the only bus activities in
which the SDA transitions when SCL is high.
Maxim Integrated
Acknowledge Bits
Each byte of a data transfer is acknowledged with
an acknowledge bit (A) or a no-acknowledge bit (N).
Both the master and the MAX17058/MAX17059 slave
generate acknowledge bits. To generate an acknowledge, the receiving device must pull SDA low before the
rising edge of the acknowledge-related clock pulse (ninth
pulse) and keep it low until SCL returns low. To generate a no-acknowledge (also called NAK), the receiver
releases SDA before the rising edge of the acknowledgerelated clock pulse and leaves SDA high until SCL
returns low. Monitoring the acknowledge bits allows for
detection of unsuccessful data transfers. An unsuccessful
data transfer can occur if a receiving device is busy or
if a system fault has occurred. In the event of an unsuccessful data transfer, the bus master should reattempt
communication.
Data Order
A byte of data consists of 8 bits ordered most significant
bit (MSb) first. The least significant bit (LSb) of each
byte is followed by the acknowledge bit. The IC registers
composed of multibyte values are ordered MSb first.
The MSb of multibyte registers is stored on even datamemory addresses.
Slave Address
A bus master initiates communication with a slave
device by issuing a START condition followed by a
slave address (SAddr) and the read/write (R/W) bit.
When the bus is idle, the ICs continuously monitor for
a START condition followed by its slave address. When
the ICs receive a slave address that matches the value
in the slave address register, they respond with an
acknowledge bit during the clock period following
the R/W bit. The 7-bit slave address is fixed to 6Ch
(write)/6Dh (read):
MAX17058 /MAX17059
SLAVE ADDRESS
0110110
Read/Write Bit
The R/W bit following the slave address determines
the data direction of subsequent bytes in the transfer.
R/W = 0 selects a write transaction with the following
bytes being written by the master to the slave. R/W = 1
selects a read transaction with the following bytes being
read from the slave by the master (Table 3).
13
MAX17058/MAX17059
1-Cell /2-Cell Li+ ModelGauge ICs
Table 3. I2C Protocol Key
KEY
DESCRIPTION
S
KEY
DESCRIPTION
START bit
Sr
Repeated START
SAddr
Slave address (7 bit)
W
R/W bit = 0
MAddr
Memory address byte
P
STOP bit
Data
Data byte written by master
Data
Data byte returned by slave
A
Acknowledge bit—master
A
Acknowledge bit—slave
N
No acknowledge—master
N
No acknowledge bit—slave
Bus Timing
The ICs are compatible with any bus timing up to
400kHz. No special configuration is required to operate
at any speed.
I2C Command Protocols
The command protocols involve several transaction
formats. The simplest format consists of the master
writing the START bit, slave address, R/W bit, and then
monitoring the acknowledge bit for presence of the ICs.
More complex formats, such as the Write Data and Read
Data, read data and execute device-specific operations.
All bytes in each command format require the slave or
host to return an acknowledge bit before continuing with
the next byte. Table 3 shows the key that applies to the
transaction formats.
Basic Transaction Formats
Write: S. SAddr W. A. MAddr. A. Data0. A. Data1. A. P
A write transaction transfers 2 or more data bytes to the
ICs. The data transfer begins at the memory address
supplied in the MAddr byte. Control of the SDA signal is
retained by the master throughout the transaction, except
for the acknowledge cycles:
Read: S. SAddr W. A. MAddr. A. Sr. SAddr R. A. Data0. A. Data1. N. P
Write Portion
Read Portion
A read transaction transfers 2 or more bytes from the
ICs. Read transactions are composed of two parts,
a write portion followed by a read portion, and are
therefore inherently longer than a write transaction. The
write portion communicates the starting point for the
Maxim Integrated
read operation. The read portion follows immediately,
beginning with a Repeated START, slave address with
R/W set to a 1. Control of SDA is assumed by the ICs,
beginning with the slave address acknowledge cycle.
Control of the SDA signal is retained by the ICs throughout the transaction, except for the acknowledge cycles.
The master indicates the end of a read transaction by
responding to the last byte it requires with a no acknowledge. This signals the ICs that control of SDA is to remain
with the master following the acknowledge clock.
Write Data Protocol
The write data protocol is used to write to register to the
ICs starting at memory address MAddr. Data0 represents
the data written to MAddr, Data1 represents the data
written to MAddr + 1, and DataN represents the last data
byte, written to MAddr + N. The master indicates the end
of a write transaction by sending a STOP or Repeated
START after receiving the last acknowledge bit:
S. SAddr W. A. MAddr. A. Data0. A. Data1. A... DataN. A. P
The MSB of the data to be stored at address MAddr
can be written immediately after the MAddr byte is
acknowledged. Because the address is automatically
incremented after the LSB of each byte is received by
the ICs, the MSB of the data at address MAddr + 1 can
be written immediately after the acknowledgment of the
data at address MAddr. If the bus master continues an
autoincremented write transaction beyond address 4Fh,
the ICs ignore the data. A valid write must include both
register bytes. Data is also ignored on writes to readonly addresses. Incomplete bytes and bytes that are not
acknowledged by the ICs are not written to memory.
14
MAX17058/MAX17059
1-Cell /2-Cell Li+ ModelGauge ICs
Read Data Protocol
The read data protocol is used to read to register from the
ICs starting at the memory address specified by MAddr.
Both register bytes must be read in the same transaction
for the register data to be valid. Data0 represents the
data byte in memory location MAddr, Data1 represents
the data from MAddr + 1, and DataN represents the last
byte read by the master:
S. SAddr W. A. MAddr. A. Sr. SAddr R. A.
Data0. A. Data1. A... DataN. N. P
Data is returned beginning with the MSB of the data
in MAddr. Because the address is automatically incremented after the LSB of each byte is returned, the MSB
of the data at address MAddr + 1 is available to the
host immediately after the acknowledgment of the data
at address MAddr. If the bus master continues to read
beyond address FFh, the ICs output data values of
FFh. Addresses labeled Reserved in the memory map
return undefined data. The bus master terminates the
read transaction at any byte boundary by issuing a no
acknowledge followed by a STOP or Repeated START.
Ordering Information
TEMP RANGE
PIN-PACKAGE
MAX17058G+
PART
-40NC to +85NC
8 TDFN-EP*
1-Cell ModelGauge IC
DESCRIPTION
MAX17058G+T10
-40NC to +85NC
8 TDFN-EP*
1-Cell ModelGauge IC
MAX17058X+
-40NC to +85NC
8 WLP
1-Cell ModelGauge IC
MAX17058X+T10
-40NC to +85NC
8 WLP
1-Cell ModelGauge IC
MAX17059G+
-40NC to +85NC
8 TDFN-EP*
2-Cell ModelGauge IC
MAX17059G+T10
-40NC to +85NC
8 TDFN-EP*
2-Cell ModelGauge IC
MAX17059X+
-40NC to +85NC
8 WLP
2-Cell ModelGauge IC
MAX17059X+T10
-40NC to +85NC
8 WLP
2-Cell ModelGauge IC
+Denotes a lead(Pb)-free/RoHS-compliant package.
*EP = Exposed pad.
T = Tape and reel.
Package Information
For the latest package outline information and land patterns (footprints), go to www.maximintegrated.com/packages. Note that a
“+”, “#”, or “-” in the package code indicates RoHS status only. Package drawings may show a different suffix character, but the
drawing pertains to the package regardless of RoHS status.
PACKAGE TYPE
PACKAGE CODE
OUTLINE NO.
LAND PATTERN NO.
8 WLP
W80B1+1
21-0555
Refer to
Application Note 1891
8 TDFN-EP
T822+3
21-0168
90-0065
Maxim Integrated
15
MAX17058/MAX17059
1-Cell /2-Cell Li+ ModelGauge ICs
Revision History
REVISION
NUMBER
REVISION
DATE
0
2/12
Initial release
1
4/12
Corrected byte-order errors
10, 11
2
6/12
Updated Absolute Maximum Ratings section; corrected memory address for CMD
2, 9, 12
3
8/12
Corrected formula for RCOMP and TempCo
6/13
Corrected conditions for entering sleep mode and Absolute Maximum voltage
ratings, and removed all mentions of EnSleep
4
DESCRIPTION
PAGES
CHANGED
—
8
2, 10
Maxim Integrated cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim Integrated product. No circuit patent
licenses are implied. Maxim Integrated reserves the right to change the circuitry and specifications without notice at any time. The parametric values (min and
max limits) shown in the Electrical Characteristics table are guaranteed. Other parametric values quoted in this data sheet are provided for guidance.
Maxim Integrated 160 Rio Robles, San Jose, CA 95134 USA 1-408-601-1000
© 2013
Maxim Integrated Products, Inc.
16
Maxim Integrated and the Maxim Integrated logo are trademarks of Maxim Integrated Products, Inc.