19-4632; 5/09 DS2746 Low-Cost 2-Wire Battery Monitor with Ratiometric A/D Inputs www.maxim-ic.com GENERAL DESCRIPTION FEATURES The DS2746 provides system-side battery capacity monitoring in cost-sensitive applications. Voltage, bidirectional current, and accumulated current measurement data is provided to the host processor over a 2-wire interface. Offset bias and offset blanking features greatly enhance the accuracy of the coulomb counter. In addition, the DS2746 has two auxiliary A/D inputs to sample the pack identification resistor, thermistor, or other voltage source. The results are reported as a ratiometric fraction of the supply voltage eliminating error related to the supply. The DS2746 reduces the total power consumption of the measurement circuit by enabling the resistor dividers, through the VOUT pin, only while measurements are made. When the system is inactive, a low power sleep mode reduces current consumption while maintaining the coulomb count. The tiny 3mm × 3mm TDFN package consumes only 9mm2 of PCB space. 14-Bit Bidirectional Current Measurement - 6.25V LSB, ±51.2mV Dynamic Range - 416.7A LSB, ±3.4A Range (RSNS = 15m) Current Accumulation Register Resolution - 6.25Vhr LSB, 409.6mVh Range - 417Ahr LSB, 27.31Ah Range 11-Bit Battery Voltage Measurement - 2.44mV LSB, 0V to 4.5V Input Range - ±10mV Accuracy at 3.6V Input Two 11-Bit Aux Input Voltage Measurements - Ratiometric Inputs Eliminate Supply Error - VOUT drives Dividers, Reduces Power - ±8 LSB Accuracy Low Power Consumption: - Active Current: 70A typical, 100A max - Sleep Current: 1A typical, 3A max ORDERING INFORMATION APPLICATIONS 2.5G/3G Wireless Handsets PDA/Smartphones Digital Still and Video Cameras Handheld Computers and Terminals PART TEMP RANGE DS2746G+ -20ºC to +70ºC DS2746G+T&R -20ºC to +70ºC PIN-PACKAGE 10-Pin 3mm×3mm TDFN DS2746G+ in Tapeand-Reel + Denotes lead(Pb)-free/RoHS-compliant package. PIN CONFIGURATION TYPICAL OPERATING CIRCUIT TOP VIEW 3mm × 3mm TDFN Note: Some revisions of this device may incorporate deviations from published specifications known as errata. Multiple revisions of any device may be simultaneously available through various sales channels. For information about device errata, click here: www.maxim-ic.com/errata. 1 of 17 DS2746 Low-Cost 2-Wire Battery Monitor ABSOLUTE MAXIMUM RATINGS Voltage Range on Any Pin Relative to Ground Operating Temperature Range Storage Temperature Range Soldering Temperature -0.3V to +6V -40°C to +85°C -55°C to +125°C See IPC/JEDECJ-STD-020A Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to the absolute maximum rating conditions for extended periods may affect device reliability. RECOMMENDED DC OPERATING CONDITIONS (VDD = 2.5V to 4.5V, TA = -20°C to +70°C.) PARAMETER Supply Voltage Data I/O Pins Programmable I/O Pin VIN, AIN0, AIN1 Pin SYMBOL CONDITIONS MIN TYP MAX UNITS VDD (Note 1) +2.5 +4.5 V SCL, SDA (Note 1) -0.3 +5.5 V PIO (Note 1) -0.3 +5.5 V VIN, AIN0, AIN1 (Note 1) -0.3 VDD + 0.3 V DC ELECTRICAL CHARACTERISTICS (VDD = 2.5V to 4.5V, TA = -20°C to +70°C.) PARAMETER SYMBOL Active Current IACTIVE Sleep-Mode Current ISLEEP CONDITIONS MIN VDD = 4.5V VDD = 2.0V, SCL, SDA = Vss SCL, SDA = Vss TYP MAX UNITS 70 100 105 A 0.5 1.0 1 3 V mV Current Resolution ILSB Current Full-Scale Magnitude IFS (Note 1) Current Offset IOERR (Note 2) -12.5 +12.5 Current Gain Error IGERR (Note 11) -1.5 +1.5 VDD = 3.6V at +25°C Timebase Accuracy tERR -1 -2 -3 -10 +1 +2 +3 +10 -20 +20 Voltage Error Input Resistance VIN, AIN0, AIN1 AIN0, AIN1 Error VOUT Output Drive VOUT Precharge Time Input Logic High: SCL, SDA Input Logic Low: SCL, SDA Output Logic Low: SDA Pulldown Current: VGERR 6.25 TA = 0C to +70C TA = -20C to +70C VDD = VIN = 3.6V RIN AINGERR A ±51.2 15 V % of reading % mV MΩ tPRE (Note 10) IO = 1mA VODIS bit = 0 -8 VDD -0.1 13.3 VIH (Note 1) 1.5 VIL (Note 1) 0.6 V VOL IOL = 4mA, (Note 1) 0.4 V IPD VDD = 4.2V, 2 of 17 +8 14.2 LSB V ms V 0.2 A DS2746 Low-Cost 2-Wire Battery Monitor SCL, SDA Input Capacitance: SCL, SDA Bus Low Timeout VPIN = 0.4V CBUS tSLEEP (Note 3) 1.5 50 pF 2.2 S MAX UNITS 400 KHz DC ELECTRICAL CHARACTERISTICS: 2-WIRE INTERFACE (VDD = 2.5V to 4.5V, TA = -20°C to +70°C.) PARAMETER SYMBOL SCL Clock Frequency fSCL Bus Free Time Between a STOP and START Condition Hold Time (Repeated) START Condition tBUF tHD:STA CONDITIONS (Note 4) (Note 5) MIN TYP 0 1.3 µs 0.6 µs Low Period of SCL Clock tLOW 1.3 µs High Period of SCL Clock tHIGH 0.6 µs Setup Time for a Repeated START Condition tSU:STA 0.6 µs Data Hold Time tHD:DAT (Note 6, 7) Data Setup Time tSU:DAT (Note 6) Rise Time of Both SDA and SCL Signals Fall Time of Both SDA and SCL Signals Setup Time for STOP Condition Spike Pulse Widths Suppressed by Input Filter Capacitive Load for Each Bus Line SCL, SDA Input Capacitance Note 1: Note 2: Note 3: Note 4: Note 5: Note 6: Note 7: Note 8: Note 9: Note 10: Note 11: 0 0.9 100 µs ns tR 20 + 0.1CB 300 ns tF 20 + 0.1CB 300 ns tSU:STO 0.6 tSP (Note 8) CB (Note 9) CBIN 0 µs 50 ns 400 pF 60 pF All voltages are referenced to VSS. Offset specified after auto-calibration cycle and Current Offset Bias register = 0x00. The DS2746 enters the sleep mode 1.5s to 2.2s after ( SCL < Vil.) AND ( SDA < Vil ). Timing must be fast enough to prevent the DS2746 from entering sleep mode due to bus low for period > tSLEEP. fSCL must meet the minimum clock low time plus the rise/fall times. The maximum tHD:DAT has only to be met if the device does not stretch the LOW period (tLOW) of the SCL signal. This device internally provides a hold time of at least 100ns for the SDA signal (referred to the VIHmin of the SCL signal) to bridge the undefined region of the falling edge of SCL. Filters on SDA and SCL suppress noise spikes at the input buffers and delay the sampling instant. Cb – total capacitance of one bus line in pF. The AINGERR spec is only valid when this equation is satisfied: (VAINx + 2VOUT) (11.6V - (TA - 25C)10mV/C). See Figure 1. Accuracy specification valid for VSS - SNS ≥ ±2.5mV, below which offset error is dominant. 3 of 17 DS2746 Low-Cost 2-Wire Battery Monitor Figure 1. Valid Range for AINGERR Accuracy Specification AINx Voltage Measurement Error Not Specified C 0° -2 °C 25 °C 70 AINx PIN VOLTAGE AS A PERCENTAGE OF VOUT (%) 100% 67% 57% 48% AINx Voltage Measurement Error ≤ AINGERR Specification 0% 2.5V 3.7 3.86 VOUT PIN VOLTAGE (V) Figure 2. 2-Wire Bus Timing Diagram 4 of 17 4.0 4.5V DS2746 Low-Cost 2-Wire Battery Monitor PIN DESCRIPTION PIN 1 2 NAME AIN1 AIN0 3 SCL 4 SDA 5 6 7 SNS VSS CTG 8 VOUT 9 VIN 10 VDD PAD PAD FUNCTION Aux Voltage Input Number 1. Aux Voltage Input Number 0. Serial Clock Input. Input only 2-wire clock line. Connect this pin to the CLOCK signal of the 2-wire interface. This pin has a 0.2µA typical pulldown to sense disconnection. Serial Data Input / Output. Open drain 2-wire data line. Connect this pin to the DATA signal of the 2-wire interface. This pin has a 0.2µA typical pulldown to sense disconnection. Current-Sense Input. Connect to the handset side of the sense resistor. Device Ground. Connect to the battery side of the sense resistor. Connect to Ground. Connect to the battery side of the sense resistor. Voltage Out. Supply for Aux input voltage Measurement dividers. Connect to high side of resistor divider circuits. Battery Voltage Input. The voltage of the cell pack is measured through this pin. Power-Supply Input. 2.5V to 4.5V input range. Connect to system power through a decoupling network. Exposed Pad. Connect to VSS. 5 of 17 DS2746 Low-Cost 2-Wire Battery Monitor Figure 3. Block Diagram DETAILED DESCRIPTION The DS2746 operates either in active mode where cell voltage, system current, and auxiliary inputs are monitored, or in a low power sleep mode to conserve energy when the system is idle. While in active mode, the DS2746 contantly measures current flow through an external sense resistor. Each current measurement is reported with sign and magnitude in a two-byte Current register. Offset bias and offset blanking features remove offset error from the current A/D to improve measurement accuracy. Each current measurement is integrated into the Accumulated Current register (ACR) to maintain a sum of all charge entering and exiting the cell. The DS2746 has two auxiliary inputs to allow voltage sampling of resistor divider circuits. These can be used to measure a thermistor or an ID resistor located inside the battery pack. The VOUT output provides the pullup voltage for the resistor divider networks. The DS2746 disables VOUT after measuring the auxiliary inputs to reduce power use by the measurement system. VOUT operation can be disabled through software to further reduce power consumption when the auxiliary inputs are not in use. A dedicated voltage A/D measures voltage of the cell and the auxiliary inputs. A mux on the input to the A/D cycles through the VIN, AIN0, and AIN1 pins repeatedly in that order. An internal reference is used to measure VIN voltage. AIN0 and AIN1 are measured as a percentage of VOUT. This ratiometric measurement of the Auxiliary inputs prevents noise in the supply from affecting accuracy of the readings The DS2746 measurements can be used directly to provide accurate fuel gauging in typical use conditions, or along with FuelPack™ algorithms to form a complete and accurate solution for estimating remaining capacity over wide temperature and operating conditions. Through its 2-Wire interface, the DS2746 allows a host system read/write access to the Status/Configuration register and Measurement registers. If sleep mode operation is enabled, holding both interface lines low forces the DS2746 into a low power sleep mode where A/D measurements are paused and the ACR register is maintained. FuelPack is a trademark of Maxim Integrated Products, Inc. 6 of 17 DS2746 Low-Cost 2-Wire Battery Monitor Figure 4. APPLICATION EXAMPLE System VDD Pack+ 150 1K VOUT VIN VDD (1) 5.6V Protection IC (Li+/Polymer) 10nF AIN0 PackID 1K Therm 1K SDA AIN1 SCL VSS CTG SNS System Serial Bus DS2746 RSNS Pack- 1nF 1nF (1) Optional for 8kV/15kV ESD 2.5V (1) System VSS POWER MODES The DS2746 operates in one of two power modes: active and sleep. While in active mode, the DS2746 operates as a high-precision battery monitor with voltage, auxiliary inputs, current and accumulated current measurements acquired continuously and the resulting values updated in the measurement registers. Read and write access is allowed to all registers. In sleep mode, the DS2746 operates in a low-power mode with no measurement activity. The DS2746 operating mode transitions from SLEEP to ACTIVE when: ( SCL > VIH ) OR ( SDA > VIH ) The DS2746 operating mode transitions from ACTIVE to SLEEP when: SMOD = 1 AND [ ( SCL < VIL ) AND ( SDA < VIL ) ] for tSLEEP CAUTION: If SMOD = 1, a pull-up resistor is required on SCL and SDA in order to ensure that the DS2746 transitions from SLEEP to ACTIVE mode when the battery is charged. If the bus is not pulled up, the DS2746 remains in SLEEP and cannot accumulate the charge current. MEASUREMENT SEQUENCE The DS2746 uses seperate A/D converters to make voltage and current measurements. Each A/D converter operates completely independent of the other, allowing measurements of voltage and current to be made in parallel. Current Measurements are made at a resolution of 13 bits plus sign bit. The current register is updated every 878ms with the average for that time period. All Voltage Measurements are made at a resolution of 11 bits plus sign bit. The DS2746 continouly cycles through measuring VIN, AIN0, and AIN1 in that order. Voltage measurement of each input requires 220ms to complete. A full sequence of voltage measurements requires 660ms to complete. VOUT is active for a precharge time of tPRE before the AIN0 measurement time occurs. The VOUT pin is enabled during the entire AIN0 and AIN1 measurement sequence as long as the VODIS (VOUT Disable) bit is cleared. See Figure 5. 7 of 17 DS2746 Low-Cost 2-Wire Battery Monitor Figure 5. Measurement Timing VOLTAGE MEASUREMENT Battery voltage is measured at the VIN input with respect to VSS over a range of 0V to 4.997V (limited by VDD pin voltage) and with a resolution of 2.44mV. The result is updated every 660ms with the average voltage over the last 220ms and placed in the VOLTAGE register in two’s compliment form. Voltages above the maximum register value are reported as 7FFFh. Figure 6. Voltage Register Format MSB—Address 0Ch S 210 29 28 27 MSb 26 LSB—Address 0Dh 25 24 23 LSb MSb “S”: sign bit(s), “X”: reserved 22 21 20 X X X X LSb Units: 2.44mV The input impedance of VIN is sufficiently large (>15M) to be connected to a high impedance voltage divider in order to support multiple cell applications. The pack voltage should be divided by the number of series cells to present a single cell average voltage to the VIN input. 8 of 17 DS2746 Low-Cost 2-Wire Battery Monitor AUXILARY INPUT MEASUREMENTS The DS2746 allows for measuring two auxiliary measurement inputs, AIN0 and AIN1, with respect to VSS. These inputs are designed for measuring resistor ratios, particularly useful for measuring thermistor or pack identification resistors. At a time of tPRE prior to the beginning of a measurement cycle on AIN0 or AIN1, the VOUT pin puts out a reference voltage in order to drive a resistive divider formed by a known resistor value, and the unknown resistance to be measured. Making these measurements ratiometric with respect to VOUT removes reference tolerance from the error calculations. Each auxiliary input measurement is updated every 660ms with the average voltage over the 220ms conversion period and placed in the AIN0 and AIN1 Registers in two’s complement form. The input impedances of AIN0 and AIN1 are sufficiently large (>15M) to be connected to a wide range of voltage divider resistances. Figure 7. Auxiliary Input Registers Format MSB—Address 08h AIN0 S 210 29 28 27 26 LSB—Address 09h 25 MSb 24 23 LSb 22 21 S 29 28 27 X X X LSb Units: 1LSB = VVOUT * 1/2047 MSB—Address 0Ah 210 X MSb “S”: sign bit, “X”: reserved AIN1 20 26 LSB—Address 0Bh 25 MSb 24 23 LSb 22 21 20 X X X MSb X LSb “S”: sign bit, “X”: reserved Units: 1LSB = VVOUT * 1/2047 CURRENT MEASUREMENT In the active mode of operation, the DS2746 continually measures the current flow into and out of the battery by measuring the voltage drop across a low-value current-sense resistor, RSNS, connected between the SNS and VSS pins. The voltage sense range between SNS and VSS is ±51.2mV. Note that positive current values occur when VSNS is less than VSS, and negative current values occur when VSNS is greater than VSS. Peak signal amplitudes up to 102mV are allowed at the input as long as the continuous or average signal level does not exceed ±51.2mV over the conversion period. The ADC samples the input differentially and updates the current register at the completion of each conversion. The result is updated every 878ms with the average voltage and placed in the CURRENT register in two’s compliment form. The current measurement register format is shown in Figure 8 and specifications for several different sense resistor options are shown in Tables 1 and 2. Charge currents above the maximum register value are reported at the maximum value (7FFFh = +51.2mV). Discharge currents below the minimum register value are reported at the minimum value (8000h = -51.2mV). Figure 8. Current Register Formats MSB—Address 0Eh S 212 211 210 MSb “S”: sign bit 29 28 LSB—Address 0Fh 27 26 25 LSb MSb 9 of 17 24 23 22 21 20 X X LSb Units: 20 = 6.25V/Rsns DS2746 Low-Cost 2-Wire Battery Monitor Table 1. Current Resolution for Various RSNS Values CURRENT RESOLUTION (1 LSB) VSS - VSNS 6.25V RSNS 20m 312.5µA 15m 416.7µA 10m 625µA 5m 1.25mA 10m ±5.12A 5m ±10.24A Table 2. Current Range for Various RSNS Values CURRENT INPUT RANGE VSS - VSNS ±51.2mV RSNS 20m ±2.56A 15m ±3.41A Every 1024th conversion, the ADC measures its input offset to facilitate offset correction. Offset correction occurs approximately once per hour. The resulting correction factor is applied to the subsequent 1023 measurements. During the offset correction conversion, the ADC does not measure the SNS to VSS signal. A maximum error of 1/1024 in the accumulated current register (ACR) is possible, however, to reduce the error, the current measurement just prior to the offset conversion is displayed in the current register and is substituted for the dropped current measurement in the current accumulation process. The error due to offset correction is typically much less than 1/1024 of the expected reading. CURRENT ACCUMULATION The Accumulated Current register (ACR) serves as an up/down counter holding a running count of charge stored in the battery. Current measurement results, plus a programmable bias value are internally summed, or accumulated, at the completion of each current measurement conversion period with the results displayed in the ACR. The ACR has a range of 0mVh to +409.6mVh with an LSb of 6.25μVhAdditional registers hold fractional results of each accumulation, however, these bits are not user accessible. The ACR count clamps at FFFFh when accumulating charge values and at 0000h when accumulating discharge values. Read and write access is allowed to the ACR. Whenever the ACR is written, fractional accumulation results are cleared. A write to the ACR also forces the ADC to measure its offset and update the offset correction factor. Current measurement and accumulation resume (using the new offset correction) with the second conversion following the write to the ACR. Figure 9 describes the ACR address, format, and resolution. Table 3 shows the ACR’s dynamic range for several different sense resistor options. Figure 9. Accumulated Current Register Format MSB—Address 10h 215 214 213 212 211 210 MSb “S”: sign bit LSB—Address 11h 29 28 LSb 27 MSb 10 of 17 26 25 24 23 22 21 20 LSb Units: 6.25Vh/Rsns DS2746 Low-Cost 2-Wire Battery Monitor Table 3. Accumulated Current Range for Various RSNS Values ACR RANGE VSS - VSNS 409.6mVh RSNS 20m 20.48Ah 15m 27.31Ah 10m 40.96Ah 5m 81.92Ah CURRENT OFFSET BIAS The Current Offset Bias register (COBR) allows a programmable offset value to be added to raw current measurements. The result of the raw current measurement plus the COBR value is displayed as the current measurement result in the CURRENT register, and is used for current accumulation. The COBR value can be used to correct for a static offset error, or can be used to intentionally skew the current results and therefore the current accumulation. Read and write access is allowed to COBR. Whenever the COBR is written, the new value is applied to all subsequent current measurements. COBR can be programmed in 1.56V steps to any value between +198V and -200V. The COBR value is stored as a two’s complement value in volatile memory, and must be initialized via the interface on power-up. Figure 10 describes the COBR address, format, and resolution. Figure 10. Current Offset Bias Register Format Address 61h S 26 MSb “S”: sign bit 25 24 23 22 21 20 LSb Units: 1.56V/Rsns CURRENT BLANKING The Current Blanking feature modifies current measurement result prior to being accumulated in the ACR. Current Blanking occurs conditionally when a current measurement (raw current + COBR) falls in one of two defined ranges. The first range prevents charge currents less than 100V/RSNS from being accumulated. The second range prevents discharge currents less than 25V/RSNS in magnitude from being accumulated. Charge current blanking is always performed, however, discharge current blanking must be enabled by setting the NBEN bit in the Status/Config register. See the register description for additional information. ACCUMULATION BIAS The Accumulation Bias register (ABR) allows a programmable offset value to be added to the current accumulation process. The new ACR value results from the addition of the Current register value plus ABR plus the previous ACR value. ABR can be used to intentionally skew the current accumulation to estimate system stand-by currents that are too small to measure. ABR value is not subject to the Current Blanking thresholds. Read and write access is allowed to the ABR. Whenever the ABR is written, the new value is applied to all subsequent current measurements. ABR can be set to any value between +193.75V and -200V in 6.25V steps. The ABR value is stored as a two’s complement value in volatile memory, and must be initialized via the interface on power-up. The lower two bits of the ABR register have no effect on the data. Figure 11 describes the ABR address, format, and resolution. 11 of 17 DS2746 Low-Cost 2-Wire Battery Monitor Figure 1. Accumulation Bias Register Format Address 62h S 24 MSb “S”: sign bit 23 22 21 20 X X LSb Units: 6.25Vh/Rsns MEMORY The DS2746 has memory space with registers for instrumentation, status, and control. When the MSB of a twobyte register is read, both the MSB and LSB are latched and held for the duration of the read data command to prevent updates during the read and ensure synchronization between the two register bytes. For consistent results, always read the MSB and the LSB of a two-byte register during the same read data command sequence. Table 4. Memory Map ADDRESS (HEX) 00 01 02 to 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 to 60 61 62 63 to FF DESCRIPTION Reserved Status/Config Register Reserved Auxiliary Input 0 Register MSB Auxiliary Input 0 Register LSB Auxiliary Input 1 Register MSB Auxiliary Input 1 Register LSB Voltage Register MSB Voltage Register LSB Current Register MSB Current Register LSB Accumulated Current Register MSB Accumulated Current Register LSB Reserved Offset Bias Register Accumulation Bias Register Reserved 12 of 17 READ/WRITE — R/W — R R R R R R R R R/W R/W — R/W R/W — POR DEFAULT X1110X00b 00h 00h 00h 00h 00h 00h 00h 00h Undefined Undefined 00h 00h DS2746 Low-Cost 2-Wire Battery Monitor STATUS/CONFIG REGISTER The Status/Config register is read/write with individual bits designated as read only. Bit values indicate status as well as program or select device functionality. Figure 12. Status/Config Register Format ADDRESS 01 BIT 7 X BIT 6 PORF BIT 5 SMOD BIT 4 NBEN BIT 3 VODIS BIT 2 X BIT 1 AIN1 BIT 0 AIN0 X — Reserved. PORF — The Power-On-Reset Flag is set to indicate initial power-up. PORF is not cleared internally. The user must write this flag value to a 0 in order to use it to indicate subsequent power-up events. If PORF indicates a power-on-reset, the ACR could be misaligned with the actual battery state of charge. The system can request a charge to full in order to synchronize the ACR with the battery charge state. PORF is read/write-to-zero. SMOD — SLEEP Mode Enable. A value of 1 allows the DS2746 to enter sleep mode when SCL AND SDA are low for tSLEEP. A value of 0 disables the transition to sleep mode. The power-up default is SMOD = 1. NBEN — Negative Blanking Enable. A value of 1 enables blanking of negative current values up to 25µV. A value of 0 disables blanking of negative currents. The power-up default is NBEN = 1. VODIS – VOUT Disable. When set to 0 this output is driven tPRE before the AIN0 conversion begins, and disabled after the AIN1 conversion ends. The power-up default is VODIS = 0, a value of 1 disables the VOUT output. AIN1 – AIN1 Conversion Valid. This read only bit indicates that the VOUT output was enabled, and a conversion has occurred on the AIN1 pin. When using the VODIS bit, before reading the AIN1 registers, read the AIN1 bit. Only once the AIN1 bit is set, should the AIN1 register be read. AIN0 – AIN0 Conversion Valid. This read only bit indicates that the VOUT output was enabled, and a conversion has occurred on the AIN0 pin. When using the VODIS bit, before reading the AIN0 registers, read the AIN0 bit. Only once the AIN0 bit is set, should the AIN0 register be read. 2-WIRE BUS SYSTEM The 2-Wire bus system supports operation as a slave-only device in a single or multislave, and single or multimaster system. The 2-wire interface consists of a serial data line (SDA) and serial clock line (SCL). SDA and SCL provide bidirectional communication between the DS2746 slave device and a master device at speeds up to 400 kHz. The DS2746’s SDA pin operates bidirectionally, that is, when the DS2746 receives data, SDA operates as an input, and when the DS2746 returns data, SDA operates as an open drain output, with the host system providing a resistive pullup. The DS2746 always operates as a slave device, receiving and transmitting data under the control of a master device. The master initiates all transactions on the bus and generates the SCL signal as well as the START and STOP bits which begin and end each transaction. Bit Transfer One data bit is transferred during each SCL clock cycle, with the cycle defined by SCL transitioning low-to-high and then high-to-low. The SDA logic level must remain stable during the high period of the SCL clock pulse. Any change in SDA when SCL is high is interpreted as a START or STOP control signal. 13 of 17 DS2746 Low-Cost 2-Wire Battery Monitor Bus Idle The bus is defined to be idle, or not busy, when no master device has control. Both SDA and SCL remain high when the bus is idle. The STOP condition is the proper method to return the bus to the idle state. START and STOP Conditions The master initiates transactions with a START condition (S), by forcing a high-to-low transition on SDA while SCL is high. The master terminates a transaction with a STOP condition (P), a low-to-high transition on SDA while SCL is high. A REPEATED START condition (Sr) can be used in place of a STOP then START sequence to terminate one transaction and begin another without returning the bus to the idle state. In multimaster systems, a REPEATED START allows the master to retain control of the bus. The START and STOP conditions are the only bus activities in which the SDA transitions when SCL is high. Acknowledge Bits Each byte of a data transfer is acknowledged with an Acknowledge bit (A) or a No Acknowledge bit (N). Both the master and the DS2746 slave generate acknowledge bits. To generate an Acknowledge, the receiving device must pull SDA low before the rising edge of the acknowledge-related clock pulse (ninth pulse) and keep it low until SCL returns low. To generate a No Acknowledge (also called NAK), the receiver releases SDA before the rising edge of the acknowledge-related clock pulse and leaves SDA high until SCL returns low. Monitoring the acknowledge bits allows for detection of unsuccessful data transfers. An unsuccessful data transfer can occur if a receiving device is busy or if a system fault has occurred. In the event of an unsuccessful data transfer, the bus master should reattempt communication. Data Order A byte of data consists of 8 bits ordered most significant bit (msb) first. The least significant bit (lsb) of each byte is followed by the Acknowledge bit. DS2746 registers composed of multibyte values are ordered most significant byte (MSB) first. The MSB of multibyte registers is stored on even data memory addresses. Slave Address A bus master initiates communication with a slave device by issuing a START condition followed by a Slave Address (SAddr) and the read/write (R/W) bit. When the bus is idle, the DS2746 continuously monitors for a START condition followed by its slave address. When the DS2746 receives a slave address that matches its Slave Address, it responds with an Acknowledge bit during the clock period following the R/W bit. The 7-bit Slave Address is fixed. DS2746 Slave Address 0110110 Read/Write Bit The R/W bit following the slave address determines the data direction of subsequent bytes in the transfer. R/W = 0 selects a write transaction, with the following bytes being written by the master to the slave. R/W = 1 selects a read transaction, with the following bytes being read from the stave by the master. Bus Timing The DS2746 is compatible with any bus timing up to 400kHz. No special configuration is required to operate at any speed. 2-Wire Command Protocols The command protocols involve several transaction formats. The simplest format consists of the master writing the START bit, slave address, R/W bit, and then monitoring the acknowledge bit for presence of the DS2746. More complex formats such as the Write Data, Read Data and Function command protocols write data, read data and execute device specific operations. All bytes in each command format require the slave or host to return an Acknowledge bit before continuing with the next byte. Each function command definition outlines the required transaction format. The following key applies to the transaction formats. 14 of 17 DS2746 Low-Cost 2-Wire Battery Monitor Table 5. 2-Wire Protocol Key KEY S SAddr FCmd MAddr Data A N DESCRIPTION START bit Slave Address (7-bit) Function Command byte Memory Address byte Data byte written by master Acknowledge bit - Master No Acknowledge - Master KEY Sr W R P Data A N DESCRIPTION Repeated START R/W bit = 0 R/W bit = 1 STOP bit Data byte returned by slave Acknowledge bit - Slave No Acknowledge - Slave Basic Transaction Formats Write: S SAddr W A MAddr A Data0 A P A write transaction transfers one or more data bytes to the DS2746. The data transfer begins at the memory address supplied in the MAddr byte. Control of the SDA signal is retained by the master throughout the transaction, except for the Acknowledge cycles. Read: S SAddr W A MAddr A Sr SAddr R A Data0 N P Write Portion Read Portion A read transaction transfers one or more bytes from the DS2746. Read transactions are composed of two parts, a write portion followed by a read portion, and is therefore inherently longer than a write transaction. The write portion communicates the starting point for the read operation. The read portion follows immediately, beginning with a REPEATED START, Slave Address with R/W set to a 1. Control of SDA is assumed by the DS2746 beginning with the Slave Address Acknowledge cycle. Control of the SDA signal is retained by the DS2746 throughout the transaction, except for the Acknowledge cycles. The master indicates the end of a read transaction by responding to the last byte it requires with a No Acknowledge. This signals the DS2746 that control of SDA is to remain with the master following the Acknowledge clock. Write Data Protocol The write data protocol is used to write to register and shadow RAM data to the DS2746 starting at memory address MAddr. Data0 represents the data written to MAddr, Data1 represents the data written to MAddr + 1 and DataN represents the last data byte, written to MAddr + N. The master indicates the end of a write transaction by sending a STOP or REPEATED START after receiving the last acknowledge bit. S SAddr W A MAddr A Data0 A Data1 A … DataN A P The msb of the data to be stored at address MAddr can be written immediately after the MAddr byte is acknowledged. Because the address is automatically incremented after the least significant bit (lsb) of each byte is received by the DS2746, the msb of the data at address MAddr + 1 is can be written immediately after the acknowledgement of the data at address MAddr. If the bus master continues an auto-incremented write transaction beyond address 4Fh, the DS2746 ignores the data. Data is also ignored on writes to read-only addresses and reserved addresses, locked EEPROM blocks as well as a write that auto increments to the Function Command register (address FEh). Incomplete bytes and bytes that are Not Acknowledged by the DS2746 are not written to memory. As noted in the Memory Section, writes to unlocked EEPROM blocks modify the shadow RAM only. Read Data Protocol The Read Data protocol is used to read register and shadow RAM data from the DS2746 starting at memory address specified by MAddr. Data0 represents the data byte in memory location MAddr, Data1 represents the data from MAddr + 1 and DataN represents the last byte read by the master. S SAddr W A MAddr A Sr SAddr R A Data0 A Data1 A … DataN N P 15 of 17 DS2746 Low-Cost 2-Wire Battery Monitor Data is returned beginning with the most significant bit (msb) of the data in MAddr. Because the address is automatically incremented after the least significant bit (lsb) of each byte is returned, the msb of the data at address MAddr + 1 is available to the host immediately after the acknowledgement of the data at address MAddr. If the bus master continues to read beyond address FFh, the DS2746 outputs data values of FFh. Addresses labeled “Reserved” in the memory map return undefined data. The bus master terminates the read transaction at any byte boundary by issuing a No Acknowledge followed by a STOP or REPEATED START. PACKAGE INFORMATION For the latest package outline information, go to www.maxim-ic.com/packages. PACKAGE TYPE PACKAGE CODE DOCUMENT NO. 10 TDFN T1033+1 21-0137 16 of 17 DS2746 Low-Cost 2-Wire Battery Monitor REVISION HISTORY REVISION DATE 051209 DESCRIPTION Changed the VDD maximum operating range in the Electrical Characteristics table to 4.5V. Added “VIN pin is limited to VDD voltage” text in the Voltage Measurement section. PAGES CHANGED 2, 3 8 17 of 17 Maxim/Dallas Semiconductor cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim/Dallas Semiconductor product. No circuit patent licenses are implied. Maxim/Dallas Semiconductor reserves the right to change the circuitry and specifications without notice at any time. Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600 © 2009 Maxim Integrated Products The Maxim logo is a registered trademark of Maxim Integrated Products, Inc. The Dallas logo is a registered trademark of Dallas Semiconductor Corporation. 17 of 17