CUI VSK-T15-KU

date
01/29/2013
page
1 of 6
SERIES: VSK 15W │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
up to 15W continuous power
compact board mount design
universal input (85~264 Vac / 120~370 Vdc)
single output from 3.3~48 V
over voltage, over current, and short circuit protections
UL/cUL safety approvals
efficiency up to 85%
MODEL
VSK-S15-3R3U
VSK-S15-5U
VSK-S15-9U
output
voltage
output
current
output
power
ripple
and noise1
efficiency
(Vdc)
max
(A)
max
(W)
typ
(mVp-p)
typ
(%)
3.3
3
9.9
50
73
5
2.8
15
50
76
9
1.6
15
50
78
VSK-S15-12U
12
1.25
15
50
80
VSK-S15-15U
15
1.0
15
50
80
VSK-S15-24U
24
0.625
15
50
84
VSK-S15-48U
48
0.32
15
50
85
VSK-D15-AU
Vo1
Vo2
5
5
2.2
0.8
15
50
76
VSK-D15-BU
Vo1
Vo2
5
12
2
0.4
15
50
81
VSK-D15-CU
Vo1
Vo2
5
15
2
0.3
15
50
83
VSK-D15-DU
Vo1
Vo2
5
24
2
0.2
15
50
76
VSK-D15-EU
Vo1
Vo2
+5
-5
1.5
1.5
15
50
80
VSK-D15-FU
Vo1
Vo2
+12
-12
0.65
0.65
15
50
80
VSK-D15-GU
Vo1
Vo2
+15
-15
0.5
0.5
15
50
81
VSK-T15-HU
Vo1
Vo2
5
±5
2
0.5
15
50
75
VSK-T15-IU
Vo1
Vo2
5
±12
2
0.5
15
50
77
VSK-T15-JU
Vo1
Vo2
5
±15
2
0.5
15
50
78
VSK-T15-KU
Vo1
Vo2
5
±24
2
0.5
15
50
78
Notes:
1. Ripple and noise measured at 20 MHz bandwidth
cui.com
CUI Inc │ SERIES: VSK 15W │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/29/2013 │ page 2 of 6
PART NUMBER KEY
VSK-X15-XX
Base Number
Outputs
S = Single
D = Dual
T = Triple
Output Voltage
3R3 = 3.3 Vdc
5 = 5 Vdc
9 = 9 Vdc
12 = 12 Vdc
15 = 15 Vdc
24 = 24 Vdc
48 = 48 Vdc
AU = 5 Vdc (Vo1 and Vo2)
BU = 5 Vdc (Vo1), 12 Vdc (Vo2)
CU = 5 Vdc (Vo1), 15 Vdc (Vo2)
DU = 5 Vdc (Vo1), 24 Vdc (Vo2)
EU = +5 Vdc (Vo1), -5 Vdc (Vo2)
FU = +12 Vdc (Vo1), -12 Vdc (Vo2)
GU = +15 Vdc (Vo1), -15 Vdc (Vo2)
HU = 5 Vdc (Vo1), ±5 Vdc (Vo2)
IU = 5 Vdc (Vo1), ±12 Vdc (Vo2)
JU = 5 Vdc (Vo1), ±15 Vdc (Vo2)
KU = 5 Vdc (Vo1), ±24 Vdc (Vo2)
INPUT
parameter
conditions/description
min
voltage
frequency
max
units
85
110
typ
264
370
Vac
Vdc
47
63
Hz
current
at 110 Vac, cold start
at 230 Vac, cold start
250
140
mA
mA
inrush current
at 110 Vac, full load, cold start
at 220 Vac, full load, cold start
10
20
A
A
input fuse
slow blow, 250 V
2
A
leakage current
230 V ac, 50 Hz
0.3
mA
OUTPUT
parameter
conditions/description
min
line regulation
main output
supplemental output
load regulation
(10 ~ 100%)
single output
dual output (balanced load)
isolated triple output
(balanced load)
isolated and separated
twin output (balanced load)
minimum load
single output
dual output (main output)
isolated triple output (main output)
isolated and separated twin output (main output)
temperature coefficient
main output
supplemental output
hold-up time
at 230 Vac
Vo1 (main output)
±Vo2 (supplemental output)
Vo1 (main output)
Vo2 (supplemental output)
switching frequency
typ
max
±0.5
±1.5
%
%
±1
±2
±3
±5
±3
±5
%
%
%
%
%
%
0.02
0.15
%/°C
%/°C
80
ms
0%
10%
10%
10%
150
cui.com
units
kHz
CUI Inc │ SERIES: VSK 15W │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/29/2013 │ page 3 of 6
PROTECTIONS
parameter
conditions/description
min
typ
max
units
110
%
7.5
12
20
30
60
Vdc
Vdc
Vdc
Vdc
Vdc
max
units
over current protection
short circuit protection
auto recovery with no damage from a short on any output
over voltage protection
3.3 V, 5 V output
9 V output
12 V, 15 V output
24 V output
48 V output
SAFETY & COMPLIANCE
parameter
conditions/description
min
typ
isolation voltage
primary to secondary (for 1 minute)
safety approvals
UL 60950-1, EN 60950-1
safety class
class II
EMI/EMC
EN55022 (level B), IEC/EN 61000-4-2 level 3 (6kV/8kV), IEC/EN 61000-4-3, IEC/EN 61000-4-4 level 3
(2kV), IEC/EN 61000-4-5 level 3 (1kV/2kV)
RoHS compliant
yes
MTBF
25°C
3,000
Vac
300,000
hrs
ENVIRONMENTAL
parameter
max
units
operating temperature
conditions/description
min
-40
typ
70
°C
storage temperature
-40
105
°C
90
°C
85
%
case temperature
operating humidity
non-condensing
DERATING CURVES
1. output power vs. input voltage
80
60
50
40
80
60
50
40
85
100
125
≈
70
210
225
240
-50
264
-40
-30
-20
-10
0
≈
20
20
50
Ambient Temperature (°C)
Input Voltage (Vac)
Note: ≈
≈
100
Load (%)
Load (%)
100
2. output power vs. ambient temperature
When input is DC voltage, Vdc=1.414Vac-20Vdc.
cui.com
60
70
CUI Inc │ SERIES: VSK 15W │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/29/2013 │ page 4 of 6
MECHANICAL
parameter
conditions/description
dimensions
2.44 x 1.77 x 0.88 (62.0 x 45.0 x 22.5 mm)
min
typ
max
inch
weight
80
case material
units
g
UL94V-0
MECHANICAL DRAWING
units: mm [inches]
tolerance: ±0.5 [±0.02]
pin diameter: 1.00±0.05mm
62.0 2.441
22.5 0.886
6.0 0.236
(TYP)
4.0 0.157
54.0 2.126
3
8
17.5 0.689
7
2
5.0 0.197
45.0 1.772
5
5
17.5 0.689
4
1
BOTTOM VIEW
4.0 0.157
(2 PLCS)
PIN CONNECTIONS
PIN
FUNCTION
Single
Dual
Isolated and separated twin
Triple
1
NP
GND
GND
GND
2
AC(N)
AC(N)
AC(N)
AC(N)
3
AC(L)
AC(L)
AC(L)
AC(L)
4
-Vo
-Vo
-Vo1
-Vo1
5
NP
NP
+Vo1
+Vo1
6
NP
COM
NP
-Vo2
7
NP
NP
-Vo2
COM
8
+Vo
+Vo
+Vo2
+Vo2
cui.com
CUI Inc │ SERIES: VSK 15W │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/29/2013 │ page 5 of 6
TYPICAL APPLICATION CIRCUIT
Single Output
L
Fus e NTC
L
+Vo
Dual Output
C1 C2 TVS1 RL
L
NT C
N
N
N
Fuse
L
+Vo
N
Co m
-Vo
-Vo
Isolated and Separated Twin Output
L
Fuse
NT C
L
N
N
C3 C 4 TVS2 R L
Triple Output
C 1 C 2 T V S 1 RL
Vo 1
L
F use
N
Vo 2
C1 C 2 TVS1 RL
NTC
+Vo1
L
N
-Vo1
+Vo2
C1 C2 TVS1 RL
C3 C4 TVS2 RL
Com
C3 C4 T V S 2 RL
-Vo2
C5 C6 TVS3 RL
EXTERNAL CAPACITORS TYPICAL VALUE (Unit: µF)
MODEL
C1
C3
C5
VSK-S15-3R3U
680
---
---
VSK-S15-5U
680
---
---
VSK-S15-9U
470
---
---
VSK-S15-12U
220
---
---
VSK-S15-15U
220
---
---
VSK-S15-24U
68
---
---
VSK-S15-48U
33
---
---
VSK-D15-AU
470
470
---
VSK-D15-BU
470
220
---
VSK-D15-CU
470
120
---
VSK-D15-DU
470
47
---
VSK-D15-EU
470
470
---
VSK-D15-FU
220
220
---
VSK-D15-GU
120
120
---
VSK-T15-HU
470
220
220
VSK-T15-IU
470
120
120
VSK-T15-JU
470
120
120
VSK-T15-KU
470
120
120
Notes:
1. Output filtering capacitors C1, C2, and C3 are electrolytic capacitors, It is recommended
to use high frequency and low impedance electrolytic capacitors. For capacitance and
current of capacitor please refer to manufacture’s datasheet. Voltage derating of capacitor
should be 80% or above. C2, C4, and C6 are used to filter high frequency noise and it is suggested
that 0.1µF capacitors are used. TVS is recommended component to protect post-circuits (when
converter fails).
2. External input NTC is recommended to use 5D-9
cui.com
CUI Inc │ SERIES: VSK 15W │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/29/2013 │ page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
07/26/2011
1.01
V-Infinity branding removed
08/16/2012
1.02
added dual and triple output models
11/16/2012
1.03
updated derating curves
01/29/2013
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to