RoHS Compliant Broadband CATV, Coupler 5-1000MHz Schematic Features • • • • • • • MACP-008125-CK07F0 V1 Surface Mount Typical Coupling 20dB RoHS* Compliant RoHS version of ELDC-20. 260°C Reflow Compatible Available on Tape and Reel. All wires are soldered to the substrate using HMP solder Description M/A-COM’s MACP-008125-CK07F0 is a high performance 75 Ohm Coupler, in a SM-55 low cost, surface mount package. The MACP-008125-CK07F0 is designed for use in high volume CATV applications. Typical applications include Set-top Boxes, Network Interface Units, Broadband Amplifiers and Headend equipment. Case Style: SM-127 Pin Configuration Pin No. Function 1 Output 2 Ground, not connected 3 Isolated (external 75 Ohms termination) 4 Coupled 5 Ground 6 Input Note: Reference Application Note M513 for reel size information. Dimensions in inches [mm] Tolerance: .xx ± .02, .xxx ± .010 Ordering Information Part Number Package MACP-008125-CK07F0 900 piece reel MACP-008125-CK07TB Customer Test Board 1 ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions is considering for development. Performance is based on target specifications, simulated results, and/or prototype measurements. Commitment to develop is not guaranteed. PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology Solutions has under development. Performance is based on engineering tests. Specifications are typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available. Commitment to produce in volume is not guaranteed. • North America Tel: 800.366.2266 • Europe Tel: +353.21.244.6400 • India Tel: +91.80.4155721 • China Tel: +86.21.2407.1588 Visit www.macomtech.com for additional data sheets and product information. M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. * Restrictions on Hazardous Substances, European Union Directive 2002/95/EC. RoHS Compliant Broadband CATV, Coupler 5-1000MHz MACP-008125-CK07F0 V1 Electrical Specifications: TA = 25°C, Z0 = 75Ω 1 Parameter Test Conditions Units Min Typ Max Mainline Loss 5 - 50 MHz 50 - 870 MHz 870 - 1000 MHz dB dB dB — — — 0.6 0.45 0.6 0.7 0.65 0.7 Coupling 5 - 870 MHz 870 - 1000 MHz dB dB — — 20 20 ± 0.8 ± 1.0 5 - 1000 MHz dB — — ± 0.5 Directivity 5 - 870 MHz 870 - 1000 MHz dB dB 10 7 14 9 — — Input Return Loss 5 - 50 MHz 50 - 1000 MHz dB dB 20 22 22 27 — — Output Return Loss 5 - 50 MHz 50 - 1000 MHz dB dB 20 22 22 28 — — Coupled Return Loss 5 - 50 MHz 50 - 1000 MHz dB dB 20 20 22 27 — — Coupling Flatness Absolute Maximum Ratings 1,2 Parameter Absolute Maximum Max Input Power 250mW DC current 30mA Operating Temperature -40°C to +85°C Storage Temperature -55°C to +100°C Recommended PCB Configuration 1. Exceeding any one or combination of these limits may cause permanent damage to this device. 2. M/A-COM does not recommend sustained operation near these survivability limits. 2 ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions is considering for development. Performance is based on target specifications, simulated results, and/or prototype measurements. Commitment to develop is not guaranteed. PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology Solutions has under development. Performance is based on engineering tests. Specifications are typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available. Commitment to produce in volume is not guaranteed. • North America Tel: 800.366.2266 • Europe Tel: +353.21.244.6400 • India Tel: +91.80.4155721 • China Tel: +86.21.2407.1588 Visit www.macomtech.com for additional data sheets and product information. M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. RoHS Compliant Broadband CATV, Coupler 5-1000MHz MACP-008125-CK07F0 V1 Typical Performance Curves TA = 25°C, Z0 = 75Ω Return Loss: Input Main Line Loss 0 0.0 -5 -0.2 -10 dB dB -0.4 -15 -20 -0.6 -25 -0.8 -30 -1.0 -35 5 204 403 602 801 1000 5 204 Frequency (MHz) 403 602 801 1000 801 1000 Frequency (MHz) Return Loss: Output Coupling 18 0 -5 -19 -20 dB dB -10 -15 -20 -25 -21 -30 -35 -22 5 204 403 602 801 5 1000 204 403 602 Frequency (MHz) Frequency (MHz) Return Loss: Coupled Directivity 0 0 -5 -5 -10 -15 dB dB -10 -15 -20 -20 -25 -25 -30 -30 -35 -35 5 5 3 204 403 602 801 100 204 403 602 801 1000 Frequency (MHz) Frequency (MHz) ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions is considering for development. Performance is based on target specifications, simulated results, and/or prototype measurements. Commitment to develop is not guaranteed. PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology Solutions has under development. Performance is based on engineering tests. Specifications are typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available. Commitment to produce in volume is not guaranteed. • North America Tel: 800.366.2266 • Europe Tel: +353.21.244.6400 • India Tel: +91.80.4155721 • China Tel: +86.21.2407.1588 Visit www.macomtech.com for additional data sheets and product information. M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.