GENERAL C8025

PRODUCT DATA SHEET
Part Number:
C8025
Revision Level:
03
1C 22 BC FMPE OA BS, 2C 22 AWG TC PVC OAS,
SIAMESE FR-PVC JKT
Date:
05/14/2012
RG 59/U Type Coaxial & 2/C 22 AWG
Shielded Siamese CCTV - Cable
A.
CONSTRUCTION A
DIAMETERS
1)
CONDUCTOR:
#22 AWG 7/30 Bare Copper
0.030” nom.
2)
3)
B.
1)
2)
INSULATION:
BRAID SHIELD:
CONSTRUCTION B
CONDUCTOR:
INSULATION:
0.057” Wall Foamed Polyethylene
Bare Copper Braid (95% Coverage)
0.144” nom.
0.171” nom.
#22 AWG 7/30 Tinned Copper
0.012” Wall Polyvinyl Chloride
0.030” nom.
0.054” nom.
3)
SHIELDED CABLE:
2 conductors (Black, Red) – shielded @2.0” LHL
with #24 AWG 7/32 Tinned Copper Drain Wire
and Aluminum/Polyester Tape (Foil Side-In)
0.113” nom.
C.
1)
FINAL CABLE
JACKET:
2)
PRINT LEGEND:
D.
INDUSTRY APPROVALS
0.032” Wall Polyvinyl Chloride
Major dim:
0.445” +/- 0.024”
Minor dim:
0.242” +/- 0.012”
CAROL (R) -- C8025 -- RG 59/U TYPE COAX – 1C 22 AWG + 2C 22 AWG
SHIELDED CL2 (ETL) OR CM c(ETL)us 75C 3084997 — MADE IN USA
(MFG CODE; MM/YY & TRU-MARK SEQ. FT. MKGS)
UL Standards 13
National Electric Code
Type CL2 (ETL)
Article 725
UL & CSA Standards 444
National Electric Code
EU 2002/95/EC
Type CM c(ETL)us
Article 800
RoHS Compliant
E.
ELECTRICAL PROPERTIES
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
12)
TEMPERATURE:
SUGGESTED WORKING VOLTAGE (Vrms):
CONDUCTOR D.C. RESISTANCE A:
CONDUCTOR D.C. RESISTANCE B:
SHIELD RESISTANCE A:
SHIELD RESISTANCE B:
MUTUAL CAPACITANCE A:
MUTUAL CAPACITANCE B:
GROUND CAPACITANCE B:
CHARACTERISTIC IMPEDANCE A:
CHARACTERISTIC IMPEDANCE B:
Attenuation:
-20C to +75C
300V MAX
14.8 Ohms/1000 ft. nom. @ 20 C
16.65 Ohms/1000 ft. nom. @ 20 C
3.00 Ohms/1000 ft. nom. @ 20 C
7.20 Ohms/1000 ft. nom. @ 20 C
17 pF/ft. @ 1 kHz nom.
38 pF/ft. @ 1kHz nom.
68 pF/ft. @ 1kHz nom.
77 Ohms @ 1 MHz nom.
65 Ohms @ 1 MHz nom.
FREQ. (MHz)
1
10
50
100
200
500
1000
Note: Data are subject to change without notice. Contact your Customer Service representative for latest information.
Rev.0: ORIGINAL FROM MANCHESTER (January 14, 2003)
Rev. 1: revise cap for B from 51 to 38 and cap to grd from 92 to 68 and imp for B from 55 to 65 – (February 25, 2010 ) // GT
Rev. 2: remove CATV from print legend / GT (3/15/2010)
dB/100 ft.
0.26
0.91
2.09
3.00
4.33
7.03
10.64
Rev. 3: revise spec from UL to ETL, Remove AWM GT/ 5/14/12