GENERAL C5039

PRODUCT DATA SHEET
Part Number:
Revision Level:
C5039
08
Date:
1C 14 SOLID BCCS, FMPE OAS PVC
03/16/2011
RG 11/U TYPE COAXIAL CABLE
A.
CONSTRUCTION
DIAMETERS
1)
CONDUCTOR:
#14 AWG Solid Bare Copper –Clad Steel
0.064” nom.
2)
INSULATION:
0.108” Wall Foamed Polyethylen
0.280” nom.
3)
TAPE:
Aluminum/Polyester/Aluminum Bonded
0.285” nom.
4)
BRAID:
0.310” nom.
5)
JACKET:
34 AWG Aluminum Braid –
65% Nom Coverage
0.045” Wall Polyvinyl Chloride ; PVC
6)
PRINT LEGEND:
B.
INDUSTRY APPROVALS
0.400” +/- 0.015”
CAROL(R) – C5039 -- RG11/U TYPE 75 OHM COAXIAL CABLE -- 1C14 AWG
SWEPT TO 3 GHZ E60233-F CL2 (UL) -- CATV OR CM C(UL) - -- MADE IN
USA (MO/YR & SEQ. FT. MKGS)
National Electrical Code
UL Standard 13
National Electrical Code
UL Standard 444
National Electrical Code
UL Standard 1655
C.
ELECTRICAL PROPERTIES
1)
2)
3)
4)
5)
6)
7)
8)
TEMPERATURE:
SUGGESTED WORKING VOLTAGE (Vrms):
CONDUCTOR D.C. RESISTANCE:
SHIELD RESISTANCE:
CAPACITANCE:
CHARACTERISTIC IMPEDANCE:
VELOCITY OF PROPAGATION
ATTENUATION (NOMINAL):
Article 725
Type CL2
Article 800
Type CM (UL) c(UL)
Article 820
Type CATV
-20ºC TO +75ºC (CM,CL2,CATV)
CL2/150V; CM /300V/ CATV/60V
11.4 Ohms/1000 ft. nom. @ 20 ºC
4.6 Ohms/1000 ft. nom. @ 20 ºC
16.2 pF/ft. @ 1kHz nom.
75 Ohms @ 1 MHz nom.
83.0 % nom.
FREQ. (MHz)
1
10
50
100
200
500
1000
1450
1800
2200
3000
dB/100 ft.
0.30
0.70
0.90
1.30
1.90
3.00
4.40
5.30
5.90
6.53
7.62
Note: Data are subject to change without notice. Contact your Customer Service representative for latest information.
Rev. 07; January 20, 2005 -from Manchester
Rev.08: revise print legend, remove AWM chg bs 60-65%, Dia & add RoHS – 03/16/2011 GT