COOPER SSW

Circuit Protection
Box Cover Units
UL/CSA Fuses
Current Limiting
Box Cover Units
for Plug Fuses
For Plug Fuses
Fuse Holder
On/Off Switch
Receptacle
Switch Light
UL/CSA Fuses
General Purpose
Plug fuse box cover units provide a simple, inexpensive way
to protect small motors with Edison-type “T”, “TL”, “TC”, “P”
and “W” plug fuses. Box cover units are easily installed in
standard electrical boxes. By using fuses sized at the amp
rating of a motor or slightly larger, optimum overload and
short-circuit protection is provided. Box cover units are UL
Listed.
SSY-RL
Box Cover
Cat. No.
Type Box
SOU
SRU
2 1⁄4" Handy
X
X
SOY
X
SRY
X
SSY
X
4" Square
UL, CSA
125V, 15A
UL
⁄2 Hp
125Vac (do not use on DC), 15A
UL, CSA
⁄4 Hp
125V, 15A
UL, CSA
⁄2 Hp
125V, 15A
UL
⁄2 Hp
125Vac (do not use on DC), 15A
UL, CSA
⁄4 Hp
125V, 15A
UL, CSA
⁄2 Hp
125V, 15A
UL
⁄2 Hp
125Vac (do not use on DC), 15A
UL, CSA
⁄4 Hp
125V, 15A
UL, CSA
⁄2 Hp
125V, 15A
UL
⁄2 Hp
125Vac (do not use on DC), 15A
UL, CSA
1
X
1
X
1
3
X
SSX
125V, 15A
⁄2 Hp
3
X
X
1
X
1
3
X
1
X
X
X
X
1
X
125Vac (do not use on DC), 15A
—
⁄2 Hp*
125Vac (do not use on DC)*, 15A
UL
125Vac (do not use on DC);
can protect two motors**, 15A
UL
X
X*
1
SCY**
X
X(2)**
1
X
SKA
4 11⁄16" Square
SSN
Single Gang
X
X(15A)
X
X
⁄2 Hp(2)**
3
⁄4 Hp
125V, protects two motors, 15A
UL
2 Hp
250V, 15A single-phase
UL
⁄2 Hp
125V, 15A Weatherproof
UL
1
Medium
Voltage Fuses
⁄2 Hp
1
STY*
SOY-B
+
X
X
4" Octagon
⁄4 Hp
1
X
SOX
General Data
Agency†
Listing/
Certification
Canadian
Fuses & Holders
SSW
SSY-RL
X
X
2 3⁄4" Switch
Motor
Size
(Max.)
3
X
SOW
SRX
Switch
Switch
Control+ Light++
X
SSU
SRW
Receptacle
Outlet to Load
125Vac 250Vac
Fuseholder
Single
Double
Special
Purpose Fuses
Selection Data — Plug Fuse Box Cover Units
Switch turns power to fused load OFF or ON.
++ Switch light indicates power to load (dark when switch OFF or fuse open).
*
Double-pole switch opens both sides of circuit. STY can be used for two separate 125V motors not larger than 1⁄2 Hp with the common switch, or a single motor not
larger than 2 Hp at 250V (Maximum of 150V to ground).
** The SCY unit can be used for protection of a single motor not larger than 2Hp at 250V (Maximum of 150V to ground).
Fuse Blocks,
Holders & Misc.
†
UL Guide JAMZ, File E6491; CSA Class 6225-01, File 47235.
Application
Section
For additional information, visit www.edisonfuse.com
137
2 1⁄4˝ Handy Boxes
UL/CSA Fuses
General Purpose
UL/CSA Fuses
Current Limiting
Box Cover Units
for Plug Fuses
SOU
2 3⁄4˝ Switch Boxes
SRU
SSU
SOW
SSW
4-11⁄16˝ Square Boxes
SOX
SRX
SSX
SKA
4˝ Square Boxes
Medium
Voltage Fuses
Canadian
Fuses & Holders
Special
Purpose Fuses
4˝ Octagon Boxes
SRW
SRY
SSY
SSY-RL
Fuse Blocks,
Holders & Misc.
SOY
STY
SCY
Application
Section
SOY-B
138
For additional information, visit www.edisonfuse.com
SSN