Product Catalog UL Fuses: Current Limiting Circuit Protection Table of Contents General Catalog Contents Page UL Fuses: Current Limiting Class RK5 Class RK1 Class RK Class L Class J Class T Class G Class CC Dual-Element, Time-Delay - ECNR/ECSR . . . . . . . . . . . . . . . . . . .1 Dual-Element, Time-Delay - LENRK/LESRK . . . . . . . . . . . . . . . . .6 Fast-Acting - NCLR/SCLR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Time-Delay - LCL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Fast-Acting - LCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Dual-Element, Time-Delay - JDL . . . . . . . . . . . . . . . . . . . . . . . . .18 Fast-Acting - JFL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Extremely Fast-Acting - TJN/TJS . . . . . . . . . . . . . . . . . . . . . . . . .22 SEC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 Time-Delay - EDCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 Time-Delay - HCTR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 Fast-Acting - HCLR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 i Circuit Protection UL/CSA Fuses Current Limiting Bullet™ Class RK5 Dual-Element Time-Delay Fuses UL/CSA Fuses General Purpose 8 9 10 12 15 17.5 20 1 2 3 4 5 6 7 8 9 10 12 15 17.5 20 ECNR/ECSR Specifications Dual-Element Time-Delay 150 175 200 225 250 300 350 400 450 500 600 — — — 150 175 200 225 250 300 350 400 450 500 600 — — — ECNR - 250Vac, ECSR - 600Vac Amp Rating: 1 - 600 Amps Interrupting Rating: 200,000 RMS Symmetrical Amps Current Limiting: RK5 Fuse Agency Approvals: UL Listed, Class RK5, Guide JDDZ, File E162363 CSA Certified, C22.2, No. 248.12, Class 1422-02, File 700489 Self-Certified DC Ratings: Voltage Rating: ECNR (1-60A, 110-200A) 125Vdc; (225-600A) 250Vdc ECSR (1-600A) 300Vdc Interrupting Rating: ECNR/ECSR 20,000 Amps DC Medium Voltage Fuses Recommended Fuse Blocks: Refer to page 124 in this catalog. Recommended Upgrade: Class RK1 (LENRK/LESRK) for greater degree of short-circuit protection. Applications: • Recommended for AC power distribution system mains, feeders, and branch circuits. • Protection of motors and motor branch circuits. • Protection of transformers and other inductive loads. • All general-purpose applications including lighting, heating and other non-inductive loads. Fuse Blocks, Holders & Misc. Benefits: • True dual-element construction allows sizing of 125% FLA for motor backup protection. • Superior overload and cycling capabilities. • Current limiting provides component short-circuit protection. Voltage Rating: Canadian Fuses & Holders 1 2 3 4 5 6 7 Amp Ratings ECNR 25 70 30 75 35 80 40 90 45 100 50 110 60 125 ECSR 25 70 30 75 35 80 40 90 45 100 50 110 60 125 Special Purpose Fuses Catalog Number ECNR (1 - 600A) 250Vac or Less Catalog Number ECSR (1 - 600A) 600Vac or Less Application Section For additional information, visit www.edisonfuse.com 1 UL/CSA Fuses Current Limiting UL/CSA Fuses General Purpose Bullet™ Class RK5 Dual-Element Time-Delay Fuses ECNR/ECSR Dual Element Fuses These fuses are recommended for AC power distribution system mains, feeders and branch circuits having inductive loads (motors, transformers) or non-inductive loads (lighting, heating) where the available short-circuit current does not exceed 200,000 RMS symmetrical amps. These “dual-element, time-delay” fuses have minimum industry standard time-delay of 10 seconds at 5 times the fuse rating (8 sec. minimum for 250V, 30A and less). The time-delay characteristics of these fuses typically allows them to be sized closer to the running ampacity of inductive loads to reduce cost and provide improved overcurrent protection. These fuses will override normal equipment current surges to reduce unnecessary fuse openings. They are the most popular fuses used in the industry and the most economical for most applications, especially motors and transformers. They have moderate current limitation. Class R fuses will fit Class H, K and R fuse clips. Class R fuse clips will only accept Class R fuses. Fuses rated 600Vac or less may be applied at any lower voltage. Contact Edison Custom Satisfaction for special products or applications. Special Purpose Fuses Dimensions Canadian Fuses & Holders Ferrule Design–0 through 60 Amps Catalog Number Medium Voltage Fuses ECNR Amps 0-30 35-60 70-100 110-200 225-400 450-600 0-30 35-60 65-100 110-200 225-400 450-600 Overall Length - in A 2 3 5.88 7.13 8.63 10.38 5 5.5 7.88 9.63 11.63 13.38 Max Diameter - in B 0.56 0.81 1.06 1.56 2.38 2.88 0.81 1.06 1.11 1.61 2.34 2.88 Application Section Fuse Blocks, Holders & Misc. ECSR Knife Blade–70 through 600 Amps 2 For additional information, visit www.edisonfuse.com Circuit Protection 400 600 200 100 60 30 UL/CSA Fuses General Purpose 8 10 15 Average Melt Time-Current Curves Cat No. ECNR (Amp) UL/CSA Fuses Current Limiting Bullet™ Class RK5 Dual-Element Time-Delay Fuses Special Purpose Fuses Canadian Fuses & Holders Medium Voltage Fuses Fuse Blocks, Holders & Misc. Application Section For additional information, visit www.edisonfuse.com 3 Application Section Fuse Blocks, Holders & Misc. Medium Voltage Fuses .01 4 700 100 10 .1 Canadian Fuses & Holders .01 RMS SYMMETRICAL CURRENTS IN AMPS For additional information, visit www.edisonfuse.com RMS SYMMETRICAL CURRENTS IN AMPS 20,000 10,000 1,000 100 100 UL/CSA Fuses General Purpose 8A 4A 5A 2A 1A 600A 400A 200A 100A 60A 30A 10A 15A AMP RATING 10 TIME IN SECONDS TIME IN SECONDS Special Purpose Fuses UL/CSA Fuses Current Limiting Bullet™ Class RK5 Dual-Element Time-Delay Fuses Average Melt Time-Current Curves Cat No. ECSR (Amp) 100 AMP RATING 10 10 1 1 .1 .1 e ela ses Circuit Protection Peak Let-Through Current Curves ECSR AMP RATING PEAK LET-THROUGH CURRENT IN AMPS X10 3 PEAK LET-THROUGH CURRENT IN AMPS X10 3 Special Purpose Fuses Canadian Fuses & Holders RMS SYMMETRICAL CURRENTS IN AMPS A—B=ASYMMETRICAL AVAILABLE PEAK (2.3 x SYMM RMS AMPS) RMS SYMMETRICAL CURRENTS IN AMPS A—B=ASYMMETRICAL AVAILABLE PEAK (2.3 x SYMM RMS AMPS) Current Limitation Tables ECNR* UL/CSA Fuses General Purpose AMP RATING ECNR UL/CSA Fuses Current Limiting llet Class al le ent T ECSR* 400A 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000 50,000 60,000 80,000 100,000 150,000 200,000 1,050 1,310 1,490 1,630 1,720 1,840 1,920 2,000 2,140 2,260 2,450 2,620 2,920 3,140 5,000 8,700 9,900 10,700 11,400 12,100 12,600 13,100 14,000 14,900 16,000 17,100 19,200 20,800 2,070 2,570 2,920 3,200 3,420 3,630 3,810 3,980 4,200 4,500 4,900 5,200 5,800 6,200 2,820 3,630 4,140 4,500 4,800 5,100 5,400 5,600 6,000 6,400 7,000 7,500 8,300 8,900 4,300 5,400 6,200 6,800 7,200 7,700 8,100 8,500 9,100 9,600 10,600 11,400 13,000 14,300 600A Available Fault Current RMS Amps Apparent Effective Let-Thruough Amps Fuse Fuse Amp Ratings 30A 60A 100A 200A 400A 600A 5,000 10,000 15,000 16,100 17,200 18,300 19,200 19,900 21,400 22,600 24,600 26,200 29,200 31,700 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000 50,000 60,000 80,000 100,000 150,000 200,000 1,290 1,640 1,890 2,110 2,260 2,420 2,570 2,670 2,890 3,060 3,360 3,630 4,100 4,400 5,000 8,800 10,200 11,400 12,400 13,200 14,100 14,700 16,000 17,200 19,100 20,700 23,900 26,700 5,000 10,000 15,000 18,200 19,600 21,100 22,400 23,400 25,300 27,000 29,500 31,700 36,300 39,500 2,070 2,590 2,940 3,250 3,470 3,660 3,850 4,030 4,300 4,500 4,900 5,200 5,800 6,100 2,980 3,810 4,400 4,800 5,200 5,500 5,800 6,000 6,500 6,900 7,600 8,200 9,300 10,400 5,000 6,500 7,500 8,300 8,900 9,600 10,100 10,500 11,400 12,100 13,400 14,400 16,500 18,300 Fuse Blocks, Holders & Misc. Apparent Effective Let-Through Amps Fuse Amp Ratings 30A 60A 100A 200A Medium Voltage Fuses Available Fault Current RMS Amps *"Apparent Let-Through Amps" values are read from "Peak Let-Through Current Curves" and the peak current value divided by 2.3 Asymmetry Factor. Application Section For additional information, visit www.edisonfuse.com 5 UL/CSA Fuses Current Limiting ses Catalog Number LENRK (0.2 - 600A) 250Vac or Less Catalog Number LESRK (0.25 - 600A) 600Vac or Less Application Section Fuse Blocks, Holders & Misc. Medium Voltage Fuses Canadian Fuses & Holders Special Purpose Fuses UL/CSA Fuses General Purpose al Class le ent T e ela 0.2 0.3 0.4 0.5 0.6 0.8 1 1.12 1.4 1.6 1.8 2 2.25 2.5 3 3.2 3.5 4 4.5 5 5.6 6 0.25 0.5 0.6 1 1.12 1.25 1.4 1.5 1.6 1.8 2 2.25 2.5 2.8 3 3.2 3.5 4 4.5 5 5.6 6 Amp Ratings LENRK 6.25 8 9 10 12 15 17.5 20 25 30 35 LESRK 6.25 7 8 9 10 12 15 17.5 20 25 30 LENRK/LESRK Specifications Dual-Element Time-Delay 40 45 50 60 70 80 90 100 110 125 150 175 200 225 250 300 350 400 450 500 600 35 40 45 50 60 70 80 90 100 110 125 150 175 200 225 250 300 350 400 450 500 600 Benefits: • True dual-element spring - trigger construction allows sizing of 125% FLA for motor backup protection. • Superior overload and cycling capabilities. • Extremely current limiting provides superior short-circuit component protection. Voltage Rating: LENRK - 250Vac, LESRK - 600Vac Amp Rating: 0.2 - 600 Amps Interrupting Rating: 200,000 RMS Symmetrical Amps Current Limiting: RK1 Fuse Agency Approvals: UL Listed, Class RK1, Guide JDDZ, File E162363 CSA Certified, HRCI-R per C22.2, No. 248.12 Self-Certified DC Ratings: Voltage Rating: LENRK (0-60A) 125Vdc; (70-600A) 250Vdc LESRK (0.25-600A) 300Vdc Interrupting Rating: LENRK/LESRK 20,000 Amps DC Recommended Fuse Blocks: Refer to page 124 in this catalog. Recommended Upgrade: None. Applications: • Recommended for AC power distribution system mains, feeders, and branch circuits. • Protection of motors and motor branch circuits. • Type 2 “No Damage” protection for IEC components. • All general-purpose applications including lighting, heating and other non-inductive loads. 6 For additional information, visit www.edisonfuse.com ses Circuit Protection True Dual-Element Construction Insulated end-caps to prevent accidental contact with live parts. UL/CSA Fuses General Purpose LENRK/LESRK Dual-Element Fuses The application recommended for these fuses is exactly the same as for the Edison ECNR/ECSR fuses except for the advantages of greater current limitation. The Edison LENRK/LESRK fuses have up to 40% more current limitation and up to 350% more Amps-Squared-Second (I2t) limitation under fault conditions than Edison ECNR/ECSR fuses to reduce potential for damage. In addition, LENRK/LESRK fuses allow better selectivity for electrical power system designers and better short-circuit protection for breakers having inadequate interrupting ratings. ECNR/ECSR and LENRK/LESRK fuse lines are physically interchangeable (and electrically interchangeable per UL equipment listing conditions) and are recommended as a practical, economical way to upgrade systems for many situations. Short-circuit element Overload element Special Purpose Fuses Class R fuses will fit Class H, K and R fuse clips. Class R fuse clips will only accept Class R fuses. Fuses rated 600Vac or less may be applied at any lower voltage. Contact Edison Custom Satisfaction for special products or applications. LENRK Amps 0-30 35-60 70-100 110-200 225-400 450-600 0-30 35-60 70-100 110-200 225-400 450-600 Overall Length - in A 2 3 5.88 7.13 8.63 10.38 5 5.5 7.88 9.63 11.63 13.38 Max Diameter - in B 0.56 0.81 1.10 1.61 2.38 2.88 0.81 1.06 1.11 1.61 2.36 2.88 Fuse Blocks, Holders & Misc. LESRK Knife Blade–70 through 600 Amps Medium Voltage Fuses Catalog Number Canadian Fuses & Holders Dimensions Ferrule Design–0 through 60 Amps UL/CSA Fuses Current Limiting al Class le ent T e ela Application Section For additional information, visit www.edisonfuse.com 7 Application Section Fuse Blocks, Holders & Misc. Medium Voltage Fuses .01 8 300 400 600 800 1,000 RMS SYMMETRICAL CURRENT IN AMPS 200 60 80 100 30 40 20 6 8 10 3 4 2 .6 .8 1 .3 .4 TIME IN SECONDS Special Purpose Fuses UL/CSA Fuses General Purpose 1/10 15/100 2/10 3/10 4/10 1/2 6/10 8/10 1 1-1/4 1-6/10 2 2-1/2 3-2/10 4 5 6-1/4 8 10 12 300 .2 .1 Canadian Fuses & Holders UL/CSA Fuses Current Limiting al Class le ent T e ela ses Average Melt Time-Current Curves LESRK (Amp) AMP RATING 200 100 80 60 40 30 20 10 8 6 4 3 2 1 .8 .6 .4 .3 .2 .1 .08 .06 .04 .03 .02 For additional information, visit www.edisonfuse.com e ela ses Circuit Protection Average Melt Time-Current Curves 600A 400A 200A 100A 60A 30A AMP RATING 300 200 100 80 60 UL/CSA Fuses General Purpose 15A 20A LESRK 40 30 20 Special Purpose Fuses 10 8 6 4 3 2 1 .8 Canadian Fuses & Holders TIME IN SECONDS .6 .4 .3 .2 .1 .08 .06 Medium Voltage Fuses .04 .03 8,000 10,000 6,000 4,000 3,000 2,000 600 400 300 200 80 100 60 40 30 .01 800 1,000 .02 20 LENRK UL/CSA Fuses Current Limiting llet Class al le ent T RMS SYMMETRICAL CURRENT IN AMPS Fuse Blocks, Holders & Misc. Application Section For additional information, visit www.edisonfuse.com 9 UL/CSA Fuses Current Limiting Class le ent T e ela al ses Peak Let-Through Current Curves* LENRK LESRK B RMS SYMMETRICAL CURRENTS IN AMPS A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) AMP RATING 30 6,000 5,000 4,000 3,000 A 2,000 1,000 200,000 80,000 100,000 40,000 50,000 60,000 30,000 20,000 8,000 10,000 4,000 5,000 6,000 3,000 2,000 8,000 200,000 A 10,000 80,000 100,000 3,000 100 60 40,000 50,000 60,000 6,000 5,000 4,000 200 20,000 30,000 30 400 30,000 20,000 8,000 600 8,000 10,000 10,000 60,000 50,000 40,000 4,000 5,000 6,000 100 60 2,000 Canadian Fuses & Holders 200 20,000 100,000 80,000 3,000 30,000 200,000 2,000 600 400 300,000 1,000 60,000 50,000 40,000 INSTANTANEOUS PEAK LET-THROUGH CURRENT IN AMPS 100,000 80,000 AMP RATING 200,000 1,000 B 400,000 300,000 1,000 INSTANTANEOUS PEAK LET-THROUGH CURRENT IN AMPS Special Purpose Fuses UL/CSA Fuses General Purpose 400,000 RMS SYMMETRICAL CURRENTS IN AMPS A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) *Curves test data obtained at 15% short-circuit power factor when possible. Application Section Fuse Blocks, Holders & Misc. Medium Voltage Fuses Current Limtation Tables** LENRK RMS & Peak Let-Through Currents (kA) LESRK RMS & Peak Let-Through Currents (kA) Available Available Fault Apparent Effective Let-Through Amps (kA) current 30 60 100 RMS Amps IRMS Ip IRMS Ip IRMS Ip 200 IRMS 1,000 2,000 3,000 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000 150,000 200,000 1 2 3 3 4 4 5 5 5 6 6 6 7 7 7 7 8 8 9 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 3 1 2 2 2 3 3 3 3 3 4 4 4 4 4 5 5 5 6 6 1 1 1 2 2 2 2 3 3 3 3 3 3 3 4 4 4 4 5 2 3 3 4 4 5 6 6 6 7 7 7 8 8 8 9 9 10 11 1 2 2 2 2 3 3 3 3 4 4 4 4 4 5 5 5 5 6 2 4 4 5 6 6 7 7 8 8 9 9 10 10 11 11 11 13 14 Ip 400 IRMS 2 5 6 7 9 10 11 12 12 13 13 14 15 16 16 17 18 19 21 1 2 3 5 7 7 8 9 9 10 10 10 11 12 12 13 13 16 18 Ip 600 IRMS 2 5 7 12 15 17 19 20 21 22 23 24 26 27 28 29 30 36 42 1 2 3 5 9 10 11 12 13 13 13 14 15 16 17 17 17 20 22 Ip Fault Apparent Effective Let-Through Amps (kA) current 30 60 100 RMS Amps IRMS Ip IRMS Ip IRMS Ip 200 IRMS Ip 400 IRMS Ip 600 IRMS Ip 2 5 7 12 21 23 25 27 29 30 31 33 35 36 38 39 40 46 50 1,000 2,000 3,000 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000 150,000 200,000 1 2 3 3 4 5 5 5 6 6 6 7 7 7 8 8 8 9 10 2 4 6 7 9 11 12 12 13 14 14 15 16 17 18 18 19 21 23 1 2 3 5 7 8 8 9 10 10 10 11 12 13 13 13 14 16 17 2 4 7 12 16 18 19 21 22 23 24 26 28 29 30 31 32 36 40 1 2 3 5 9 10 11 12 13 13 14 15 16 17 17 18 19 22 23 2 4 7 12 21 24 26 28 30 31 32 35 37 39 40 42 44 50 54 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 3 3 1 2 2 2 3 3 3 4 4 4 4 5 5 5 5 5 6 6 7 1 1 1 2 2 2 3 3 3 3 3 3 3 4 4 4 4 5 5 2 3 3 4 5 5 6 6 6 7 7 8 8 8 9 9 9 11 12 1 2 2 2 3 3 3 3 4 4 4 4 4 5 5 5 5 6 7 2 4 4 5 6 7 7 8 8 9 9 10 10 11 11 12 12 14 15 **"Apparent Let-Through Amps" values are read from "Peak Let-Through Current Curves" and the peak current value divided by 2.3 Asymmetry Factor. 10 For additional information, visit www.edisonfuse.com Class Class ast ast tn tn ses ses Circuit Protection UL/CSA Fuses Current Limiting C C UL/CSA Fuses General Purpose 10 12 15 20 25 30 1 2 3 4 5 6 8 10 12 15 20 25 NCLR/SCLR Specifications Fast-Acting 175 200 225 250 300 350 400 450 500 600 — — 150 175 200 225 250 300 350 400 450 500 600 — Amp Rating: 1 - 600 Amps Interrupting Rating: 200,000 RMS Symmetrical Amps Current Limiting: RK1 Fuse Agency Approvals: UL Listed, Class RK1, Guide JDDZ, File E162363 CSA Certified per C22.2, No. 248.12 Self-Certified DC Ratings: Voltage Rating: NCLR (1-600) 250Vdc SCLR (1-600) 300Vdc Interrupting Rating: NCLR/SCLR 10,000 Amps DC Recommended Fuse Blocks: Refer to page 124 in this catalog. Recommended Upgrade: LENRK/LESRK. Fuse Blocks, Holders & Misc. Applications: • Recommended for protection on non-inductive loads such as lighting and resistance heating circuits. • Use to protect lower interrupting rating circuit breakers in series rated applications. NCLR - 250Vac, SCLR - 600Vac Medium Voltage Fuses Benefits: • No intentional time-delay opens quickly on overload current. Voltage Rating: Canadian Fuses & Holders 1 3 4 5 6 8 Amp Ratings NCLR 35 80 40 90 45 100 50 110 60 125 70 150 SCLR 30 70 35 80 40 90 45 100 50 110 60 125 Special Purpose Fuses Catalog Number NCLR (1- 600A) 250Vac or Less Catalog Number SCLR (1- 600A) 600Vac or Less Application Section For additional information, visit www.edisonfuse.com 11 UL/CSA Fuses Current Limiting UL/CSA Fuses General Purpose C C Class Class ast ast tn tn ses ses NCLR CLASS RK1 FAST-ACTING FUSES SCLR CLASS RK 1 FAST-ACTING FUSES Application: Edison NCLR/SCLR Class RK1 fast-acting fuses are recommended for general power distribution system use for main, feeder and branch circuits having a high percentage of non-inductive loads such as heating and lighting. NCLR/SCLR fuses are suitable for circuit breaker protection.* When NCLR/SCLR fast-acting fuses are used for inductive loads, the fuses usually require oversizing to override normal transient current surges of motors and transformers. Oversizing fuses usually increases fuse and equipment cost and reduces overcurrent protection. (For inductive loads, LENRK/LESRK fuses are recommended). NCLR/SCLR Class RK1 fast-acting fuses are physically interchangeable with other Class R fuses. They will replace Class K or Class H fuses in standard fuse clips. *When used as recommended by a specific circuit breaker manufacturer for a specific application. Average Time-Current Curves 400A 600A 600 800 1,000 200A 100A 60A Special Purpose Fuses 30A Cat. No. NCLR (Amp) and SCLR (Amp) AMP RATING 300 200 100 80 60 40 30 Canadian Fuses & Holders 20 10 8 6 Medium Voltage Fuses TIME IN SECONDS 4 3 2 1 .8 .6 .4 .3 .2 .1 .08 Fuse Blocks, Holders & Misc. .06 .04 .03 .02 8,000 10,000 6,000 4,000 3,000 2,000 400 300 200 80 100 60 40 .01 Application Section RMS SYMMETRICAL CURRENT IN AMPS 12 For additional information, visit www.edisonfuse.com Class Class ast ast tn tn ses ses Circuit Protection Peak Let-Through Current Curves* SCLR 3,000 A 200,000 80,000 100,000 40,000 50,000 60,000 30,000 20,000 8,000 10,000 4,000 5,000 6,000 3,000 2,000 AMP RATING 3,000 A 2,000 1,000 RMS SYMMETRICAL CURRENTS IN AMPS A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) 30 6,000 5,000 4,000 Canadian Fuses & Holders 1,000 1,000 2,000 60 8,000 80,000 100,000 30 100 10,000 40,000 50,000 60,000 6,000 5,000 4,000 200 20,000 30,000 60 8,000 30,000 20,000 100 10,000 400 8,000 10,000 200 20,000 600 60,000 50,000 40,000 4,000 5,000 6,000 30,000 100,000 80,000 3,000 400 200,000 2,000 600 300,000 1,000 100,000 80,000 INSTANTANEOUS PEAK LET-THROUGH CURRENT IN AMPS AMP RATING 200,000 Special Purpose Fuses INSTANTANEOUS PEAK LET-THROUGH CURRENT IN AMPS 300,000 60,000 50,000 40,000 B 400,000 UL/CSA Fuses General Purpose B 400,000 200,000 NCLR UL/CSA Fuses Current Limiting C C RMS SYMMETRICAL CURRENTS IN AMPS A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) *Curves test data obtained at 15% short-circuit power factor when possible. Current Limitation Tables** SCLR NCLR – RMS & Peak Let-Through Currents (kA) SCLR – RMS & Peak Let-Through Currents (kA) Fuse Size 30 IRMS Ip 1 2 1 2 1 3 1 3 1 3 1 3 1 3 1 3 2 4 2 4 2 4 2 4 2 4 2 4 2 5 2 5 60 IRMS 1 1 2 2 2 2 2 2 2 2 3 3 3 3 3 3 Ip 3 3 4 4 5 5 5 5 5 6 6 6 6 7 7 8 100 IRMS 2 2 2 3 3 3 3 3 4 4 4 4 5 5 5 6 Ip 4 5 6 6 7 7 8 8 9 9 9 10 10 11 13 14 200 IRMS 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 9 Ip 6 8 9 10 10 11 12 12 13 14 15 15 16 17 19 21 400 IRMS 5 6 7 8 9 10 10 10 11 12 13 13 13 14 16 18 Ip 10 14 17 19 20 22 23 24 26 28 29 30 31 32 37 41 600 IRMS 5 8 10 11 12 13 13 14 15 17 17 18 19 20 23 26 Ip 12 19 22 25 27 29 31 32 36 38 40 42 44 46 53 59 Prosp. Short C.C. 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000 150,000 200,000 Fuse Size 30 IRMS Ip 1 2 1 2 1 3 1 3 1 3 1 3 2 4 2 4 2 4 2 4 2 4 2 4 2 5 2 5 2 5 3 6 60 IRMS 1 2 2 2 2 2 2 2 3 3 3 3 3 3 4 4 Ip 3 4 4 5 5 5 5 6 6 6 7 7 7 7 8 9 100 IRMS 2 2 3 3 3 3 4 4 4 4 5 5 5 5 6 7 Ip 4 5 6 7 7 8 8 9 9 10 10 11 12 12 14 15 200 IRMS 3 4 4 5 5 5 6 6 6 7 7 7 8 8 9 10 Ip 6 8 10 11 12 13 13 14 14 15 16 17 18 19 21 23 400 IRMS 5 7 8 9 10 10 11 11 12 13 14 14 15 16 18 20 Ip 12 15 18 20 22 24 25 26 28 30 32 33 35 36 41 46 600 IRMS 5 9 11 12 13 14 15 16 17 19 20 21 22 23 26 29 Ip 12 20 24 28 31 33 35 37 40 43 45 48 50 52 60 66 For additional information, visit www.edisonfuse.com Application Section **"Apparent Let-Through Amps" values are read from "Peak Let-Through Current Curves" and the peak current value divided by 2.3 Asymmetry Factor. Fuse Blocks, Holders & Misc. Prosp. Short C.C. 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000 150,000 200,000 Medium Voltage Fuses NCLR 13 T e ast ela tn ses ses Application Section Fuse Blocks, Holders & Misc. Medium Voltage Fuses Canadian Fuses & Holders Special Purpose Fuses UL/CSA Fuses General Purpose UL/CSA Fuses Current Limiting llet Class llet Class Catalog Number LCL (300 - 6000A) Time-Delay 600Vac or Less Catalog Number LCU (601 - 6000A) Fast-Acting 600Vac or Less 300* 400* 500* 601 650 700 750 800 601 650 700 800 1000 1200 Amp Ratings LCL 801 1350 900 1400 1000 1500 1200 1600 LCU 1350 1800 1500 2000 1600 2500 1800 2000 2500 3000 3500 4000 — — 3000 3500 4000 6000 — — LCL/LCU Specifications LCL: Time-Delay LCU: Fast-Acting Voltage Rating: LCL - 600Vac, LCU - 600Vac Amp Rating: LCL: 300 - 4000 Amps LCU: 601 - 6000 Amps Interrupting Rating: 200,000 RMS Symmetrical Amps * Not UL Listed (See note below). Current Limiting: Class L Fuse LCL: Time-delay of 5 seconds minimum at 500% rated current allows closer sizing. Agency Approvals: UL Listed, Class L, Guide JDDZ, File E162363 CSA Certified HRC-L per C22.2, No. 248.10 NOTE: LCL 300 - 500 amp fuses are physically the same as 800 amp size; Use in 800 amp switch where load current is not fully utilized and a smaller fuse amp size is desired. Also useful in new installations to allow for future upgrades in service. Benefits: • “O-ring” construction insures maximum current limiting ability. • Silver plated micro-peened terminals. • High strength melamine fuse tubes. Recommended Sizing: LCL: 150% or more of motor full load current. Recommended Upgrade: None Available. Applications: • LCL: Recommended for AC power distribution system mains and large feeders. • LCU: Recommended for non-inductive heating and lighting loads. Also suitable for protection of low interrupting rating circuit breakers. 14 For additional information, visit www.edisonfuse.com T e ast ela tn ses ses Circuit Protection Average Time-Current Curves 5000A 6000A 4000A 3000A 2000A AMP RATING 1200A 1350A 1600A 800A 4000A 1200A 1600A 2000A 3000A Cat. No. LCU (Amp) AMP RATING UL/CSA Fuses General Purpose 300 800A Cat. No.LCL (Amp) UL/CSA Fuses Current Limiting llet Class llet Class 300 200 100 100 80 60 40 30 Special Purpose Fuses 20 10 10 8 6 TIME IN SECONDS 1 3 2 Canadian Fuses & Holders TIME IN SECONDS 4 1 .8 .6 .4 .3 .2 .1 .1 .08 Medium Voltage Fuses .06 .04 .03 80,000 100,000 60,000 40,000 30,000 20,000 8,000 10,000 6,000 4,000 3,000 100,000 1,000 .01 10,000 1,000 .01 2,000 .02 RMS SYMMETRICAL CURRENT IN AMPS Fuse Blocks, Holders & Misc. RMS SYMMETRICAL CURRENT IN AMPS Application Section For additional information, visit www.edisonfuse.com 15 UL/CSA Fuses Current Limiting llet Class llet Class T e ast ela tn ses ses Peak Let-Through Current Curves* LCU B 400,000 B 60,000 AMP RATING 40,000 30,000 20,000 10,000 8,000 6,000 4,000 3,000 A 60,000 40,000 30,000 20,000 8,000 10,000 6,000 80,000 100,000 RMS SYMMETRICAL CURRENTS IN AMPS A-B= ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) 4,000 1,000 3,000 2,000 2,000 200,000 1,000 100,000 A 100,000 80,000 1,000 INSTANTENOUS PEAK LET-THROUGH CURRENT AMPS 10,000 1,000 Canadian Fuses & Holders 200,000 AMP RATING 100,000 6,000 5,000 4,000 3,000 2,500 2,000 1,600 1,200 800 601 300,000 4,000 3,000 2,500 2,000 1,600 1,200 800 10,000 INSTANTENOUS PEAK LET-THROUGH CURRENT AMPS Special Purpose Fuses UL/CSA Fuses General Purpose 400,000 200,000 LCL RMS SYMMETRICAL CURRENTS IN AMPS A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) *Curves test data obtained at 15% short-circuit power factor when possible. Fuse Blocks, Holders & Misc. Medium Voltage Fuses Current Limitation Tables** LCL LCU Current-Limiting Effects *Prosp. Let-Through Current (Apparent RMS Symmetrical) S.C.C. Versus Fuse Ratings 800A 1200A 1600A 2000A 3000A 5,000 5,000 5,000 5,000 5,000 5,000 10,000 10,000 10,000 10,000 10,000 10,000 15,000 13,000 15,000 15,000 15,000 15,000 20,000 14,000 18,000 20,000 20,000 20,000 25,000 16,000 21,000 25,000 25,000 25,000 30,000 16,500 22,500 26,000 30,000 30,000 40,000 18,000 25,500 29,000 34,000 40,000 50,000 19,000 27,000 32,000 37,000 42,000 60,000 21,000 29,000 35,000 41,000 45,000 80,000 24,000 32,000 39,000 45,000 51,000 100,000 26,000 36,000 41,000 51,000 55,000 150,000 30,000 40,000 48,000 58,000 66,000 200,000 34,000 45,000 52,000 65,000 76,000 Current-Limiting Effects *Prosp. Let-Through Current (Apparent RMS Symmetrical) S.C.C. Versus Fuse Ratings 800A 1200A 1600A 2000A 3000A 4000A 5,000 5,000 5,000 5,000 5,000 5,000 5,000 10,000 9,700 10,000 10,000 10,000 10,000 10,000 15,000 11,500 13,000 15,000 15,000 15,000 15,000 20,000 12,500 15,400 18,000 20,000 20,000 20,000 25,000 14,000 16,000 21,000 25,000 25,000 25,000 30,000 14,500 17,500 22,000 27,000 30,000 30,000 35,000 15,000 18,000 24,000 28,000 35,000 35,000 40,000 15,500 19,000 25,000 29,000 40,000 40,000 50,000 16,000 21,000 26,000 32,000 44,000 48,000 60,000 19,000 24,000 28,000 34,000 48,000 51,000 80,000 20,000 26,000 31,000 36,000 52,000 60,000 100,000 23,000 29,000 39,000 40,000 57,000 68,000 150,000 27,000 34,000 40,000 47,000 70,000 79,000 200,000 29,000 39,000 43,000 50,000 78,000 93,000 * RMS Symmetrical Amps Short-Circuit Current. NOTE: Data derived from Current Limiting Curves. 4000A 5,000 10,000 15,000 20,000 25,000 30,000 40,000 45,000 50,000 57,000 64,000 78,000 92,000 6000A 5,000 10,000 15,000 20,000 25,000 30,000 40,000 50,000 60,000 80,000 90,000 110,000 140,000 5000A 6000A 5,000 5,000 10,000 10,000 15,000 15,000 20,000 20,000 25,000 25,000 30,000 30,000 35,000 35,000 40,000 40,000 50,000 50,000 60,000 60,000 72,000 80,000 81,000 95,000 98,000 115,000 110,000 141,000 *RMS Symmetrical Amps Short-Circuit Current. NOTE: Data derived from Current Limiting Curves. Application Section **"Apparent Let-Through Amps" values are read from "Peak Let-Through Current Curves" and the peak current value divided by 2.3 Asymmetry Factor. 16 For additional information, visit www.edisonfuse.com T e ast ela tn ses ses Circuit Protection Class L Fuses Specification: Install Class L Fuses in switches rated 601-6000 amps and in AMP RATINGS and “time-delay” or “fastacting” types as shown on the plans. Installed and spare “time-delay” fuses shall be Catalog Number LCL and “fastacting” fuses shall have silver links and be Catalog Number LCU. Fuses shall be Edison fuses or equivalent submitted to the design engineer for approval 10 days prior to the project bid date. Mounting of “Bolt-On” Fuses shall be made by installing stainless steel bolts of correct number, diameter and length*, stainless steel spring washers on each side of the bolt and stainless steel nuts. The nuts shall be tightened to the torque recommended by ASTM Standards for the bolt size used. UL/CSA Fuses General Purpose General Application: Edison Class L fuses, Catalog Numbers LCL time-delay or LCU fast acting are recommended for high capacity main, feeder or branch circuits in power distribution systems and for special applications such as system upgrading, install ahead of network protectors, etc. The choice of LCL or LCU depends on the extent of mixed inductive and non-inductive loads diversity. Apply LCL fuses for protection of large individual motor circuits. Size LCL fuses at 150% or more of the motor nameplate current rating by checking starting characteristics against minimum melt Time-Current Curve. UL/CSA Fuses Current Limiting llet Class llet Class *Bolts shall have the largest diameter to fit fuse bolt holes and length to allow full nut thread engagement. Bolts shall be installed in each fuse mounting hole. Special Purpose Fuses Class L Fuse Dimensions - inches Canadian Fuses & Holders Medium Voltage Fuses Fuse Blocks, Holders & Misc. Application Section For additional information, visit www.edisonfuse.com 17 UL/CSA Fuses Current Limiting ses UL/CSA Fuses General Purpose T Class e ela 1 1.25 1.6 2 2.5 3 3.5 4 5 5.6 6 7 8 10 Amp Ratings JDL 12 40 15 45 17.5 50 20 60 25 70 30 80 35 90 JDL Specifications Dual-Element, Time-Delay 100 110 125 150 175 200 225 250 300 350 400 450 500 600 Edison JDL Class J fuses are among the most current limiting time-delay fuses available. Their small physical size and high performance characteristics makes Class J fuses ideal for any space-limited application. Benefits: • Space saving dimensions vs. Class R. • Dual-Element construction provides superior time-delay to pass harmless motor or transformer surges. • High performance with fatigue - free cycling capabilities. • Extremely current limiting. Voltage Rating: JDL - 600Vac Amp Rating: 1 - 600 Amps Interrupting Rating: 200,000 RMS Symmetrical Amps Current Limiting: Class J Fuse Agency Approvals: UL Listed, Class J, Guide JDDZ, File E162363 CSA Certified per C22.2, No. 248.8 Self-Certified DC Ratings: Voltage Rating: JDL (1-600) 300Vdc Interrupting Rating: JDL 20,000 Amps DC Recommend Fuse Blocks: Refer to page 130 in this catalog. Recommend Upgrade: None. Applications: • Recommended for Type 2 “No Damage” protection of IEC style motor starters and contactors. • Use to protect lower interrupting rating circuit breakers. • All general purpose circuits with inductive (high inrush) loads, including motor and motor branch circuits, and transformer circuits. Also suitable for lighting loads. Application Section Fuse Blocks, Holders & Misc. Medium Voltage Fuses Canadian Fuses & Holders Special Purpose Fuses Catalog Number JDL (1 - 600A) 600Vac or Less 18 For additional information, visit www.edisonfuse.com T ses Circuit Protection AMP RATING 200,000 100 60,000 80,000 100,000 200 RMS SYMMETRICAL CURRENTS IN AMPS A–B=ASYMMETRICAL AVAILALBE PEAK (2.3 X SYMM RMS AMPS) .04 .03 4,000 3,000 AMP RATING 2,000 1,000 800 600 400 300 A 200,000 60,000 80,000 100,000 30,000 40,000 20,000 6,000 8,000 10,000 3,000 4,000 100 2,000 200 600 800 1,000 600A —± — — 8,000 9,000 10,000 11,100 11,800 12,500 13,270 13,820 15,000 16,000 17,270 19,270 20,600 300 400 400A — — 4,400 5,540 6,420 7,000 7,500 8,000 8,330 9,000 9,380 10,000 11,270 12,180 14,360 15,820 Fuse Blocks, Holders & Misc. 1,000 3,000 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000 50,000 60,000 80,000 100,000 150,000 200,000 Let-Through Current (Apparent RMS Symmetrical) JDL Fuse Ratings 15A 30A 60A 100A 200A 270 470 750 — — 370 670 1,130 1,640 2,360 450 800 1,420 1,910 2,760 550 1,000 1,730 2,450 3,520 625 1,220 1,890 2,850 4,000 700 1,330 2,120 3,090 4,400 750 1,440 2,250 3,400 5,000 800 1,530 2,370 3,650 5,140 820 1,600 2,580 3,780 5,430 900 1,640 2,670 4,000 5,640 925 1,760 2,790 4,470 6,000 1,000 1,850 3,000 4,670 6,420 1,160 2,000 3,220 5,000 7,400 1,220 2,150 3,520 5,360 7,950 1,400 2,460 4,000 6,170 9,000 1,560 2,640 4,450 7,000 10,000 100 60 50 40 30 20 15 10,000 8,000 6,000 Medium Voltage Fuses *Prosp. S.C.C. 200 20,000 200 Current-Limiting Effects 600 400 40,000 30,000 100 RMS SYMMETRICAL CURRENT IN AMPS B 100,000 80,000 60,000 INSTANTANEOUS PEAK LET-THROUGH CURRENT IN AMPS 6,000 8,000 10,000 3,000 4,000 2,000 600 800 1,000 300 400 200 60 80 100 30 40 20 6 8 10 3 4 1 .01 2 .02 Canadian Fuses & Holders .1 .08 .06 400 300 30,000 40,000 .2 1,000 800 600 20,000 .4 .3 A 2,000 6,000 8,000 10,000 1 .8 .6 4,000 3,000 3,000 4,000 2 1 2,000 TIME IN SECONDS 4 3 10,000 8,000 6,000 Special Purpose Fuses 10 8 6 7 6 3 20,000 600 800 1,000 20 10 300 400 40 30 40,000 30,000 200 100 80 60 100 200 B 100,000 80,000 60,000 INSTANTANEOUS PEAK LET-THROUGH CURRENT IN AMPS 600A 400A 200A 225A 125A 100A 15A 20A 30A 40A 50A 60A Amp Rating UL/CSA Fuses General Purpose 300 10A Cat. No. JDL (Amp) 5A Cat. No. JDL (Amp) 3A Peak Let-Through Current Curves 1A Average Time-Current Curve UL/CSA Fuses Current Limiting Class e ela RMS SYMMETRICAL CURRENTS IN AMPS A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) *RMS Symmetrical Amps Short-Circuit Current. NOTE: Data derived from Current Limiting Curves. Application Section Dimensions Refer to JFL Section on page 21. For additional information, visit www.edisonfuse.com 19 ses UL/CSA Fuses General Purpose UL/CSA Fuses Current Limiting Class ast tn 1 2 3 4 5 6 8 10 12 15 20 25 Amp Ratings JFL 30 70 35 80 40 90 45 100 50 110 60 125 JFL Specifications Fast-Acting 150 175 200 225 250 300 350 400 450 500 600 — Voltage Rating: JFL - 600Vac Ampere Rating: 1 - 600 Amps Interrupting Rating: 200,000 RMS Symmetrical Amps Current Limiting: Class J Fuse Edison JFL Class J fuses are among the most current limiting fuses available. Their small physical size and high performance characteristics makes Class J fuses ideal for any space - limited application. Edison JFL fuses are best suited for the protection of non-inductive loads such as resistive heating, and lighting circuits. Agency Approvals: UL Listed, Class J, Guide JDDZ, File E162363 CSA Certified per C22.2, No. 248.8 Benefits: • Space saving dimensions vs. Class R. • Fast-acting design permits quick response for both overloads and shorts. • Extremely current-limiting. Recommended Fuse Blocks: Refer to page 130 in this catalog. Recommended Upgrade: JDL. Applications: • Recommended for protection of non-inductive loads, such as lighting and resistance heating circuits. • For motor applications, refer to Edison JDL. Application Section Fuse Blocks, Holders & Misc. Medium Voltage Fuses Canadian Fuses & Holders Special Purpose Fuses Catalog Number JFL (1 - 600A) 600Vac or Less 20 For additional information, visit www.edisonfuse.com ast T e tn ela ses ses Circuit Protection Cat No. JFL and JDL Dimensions - inches Max. Dia. B 13/16 1-1/16 1-1/18 1-5/8 2-1/8 2-5/8 Blade Length C – – 1 1-3/8 1-7/8 2-1/8 Barrel Length D – – 2-5/8 3 3-3/8 3-3/4 600A 400A 200A 100A 60A Mounting Hole Spacing G H – – – – 1/2 3-5/8 11/16 4-3/8 15/16 5-1/4 1 6 J – – 3/8 3/8 17/32 11/16 K – – 9/32 9/32 13/32 17/32 Current Limitation Table* JFL AMP RATING 300 200 100 80 60 40 30 20 6 4 Prosp. Short C.C. 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000 150,000 200,000 Fuse Size 30 IRMS Ip 1 2 1 3 1 3 1 3 2 4 2 4 2 4 2 4 2 5 2 5 2 5 2 5 2 5 2 5 2 5 3 6 60 IRMS 1 2 2 2 3 3 3 3 3 3 3 3 4 4 5 5 Ip 3 4 4 5 6 6 7 7 8 8 8 8 9 9 11 12 100 IRMS 2 3 3 3 3 3 4 4 4 5 5 5 6 6 6 7 Ip 4 6 6 7 8 8 9 9 10 11 12 12 13 13 14 15 200 IRMS 3 4 4 5 6 6 6 7 7 7 8 8 9 9 9 10 400 IRMS 4 6 7 8 9 9 9 10 10 11 11 12 13 13 14 16 Ip 7 9 10 12 13 13 14 15 16 17 18 18 19 19 21 22 Ip 10 13 15 18 19 20 21 22 23 25 25 28 29 30 33 37 600 IRMS 5 9 10 11 12 13 13 14 15 16 17 17 18 18 22 24 Ip 12 19 22 25 28 30 30 32 35 37 39 39 41 42 50 55 3 2 Peak Let-Through Current Curves** 400,000 300,000 3,000 A 8,000 10,000 6,000 4,000 3,000 2,000 800 1,000 600 400 300 200 80 100 60 40 200,000 2,000 RMS SYMMETRICAL CURRENTS IN AMPS A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) * "Apparent Let-Through Amps" values are read from "Peak Let-Through Current Curves" and the peak current value divided by 2.3 Asymmetry Factor. ** Curves test data obtained at 15% short-circuit power factor when possible. For additional information, visit www.edisonfuse.com 21 Application Section RMS SYMMETRICAL CURRENT IN AMPS 30 6,000 5,000 4,000 1,000 .01 AMP RATING 8,000 80,000 100,000 .02 100 60 10,000 40,000 50,000 60,000 .03 200 20,000 30,000 .04 400 30,000 20,000 .06 600 8,000 10,000 .1 .08 60,000 50,000 40,000 4,000 5,000 6,000 .2 100,000 80,000 3,000 .3 2,000 .4 JFL (600Vac) 200,000 1,000 .6 B Fuse Blocks, Holders & Misc. INSTANTANEOUS PEAK LET-THROUGH CURRENT IN AMPS 1 .8 Medium Voltage Fuses 10 8 TIME IN SECONDS Blade Width F – – 3/4 1-1/8 1-5/8 2 Canadian Fuses & Holders 30A Average Time-Current Curve Cat. No. JFL (Amp) Blade Thickness E – – 1/8 3/16 1/4 3/8 Special Purpose Fuses Overall Length A 2-1/4 2-3/8 4-5/8 5-3/4 7-1/8 8 UL/CSA Fuses General Purpose Amp Rating Range 1-30 35-60 70-100 110-200 225-400 450-600 UL/CSA Fuses Current Limiting Class Class a a Class T ast Class T ast tn tn ses ses Catalog Number TJN (1 - 1200A) 300Vac or Less Catalog Number TJS (1 - 800A) 600Vac or Less 1 3 6 10 15 20 30 35 40 45 50 60 1 3 6 10 15 20 25 30 35 40 45 50 Amp Ratings TJN 70 150 80 175 90 200 100 225 110 250 125 300 TJS 60 125 70 150 80 175 90 200 100 225 110 250 TJN/TJS Specifications Extremely Fast-Acting 350 400 450 500 600 700 800 1000 1200 — — — 300 350 400 450 500 600 800 — — — — — Edison Class T fuses are extremely fast-acting fuses in a compact, space saving size. These fuses are ideal as the main fuse protection for panelboards, load centers and meter stacks. Benefits: • No intentional time-delay; opens quickly on overload. • Extremely current-limiting silver link construction; provides superior short-circuit component protection. Applications: • Recommended for protection of non-inductive loads, such as lighting and resistance heating circuits. • Use to protect lower interrupting rating circuit breakers when series rated with Class T fuses. • For motor protection, size at 300% FLA which provides short circuit protection only. Voltage Rating: TJN - 300Vac, TJS - 600Vac Amp Rating: TJN: 1 - 1200 Amps TJS: 1 - 800 Amps Interrupting Rating: 200,000 RMS Symmetrical Amps Current Limiting: Class T Fuse Agency Approvals: UL Listed, Class T, Guide JDDZ,, File E162363 CSA Certified per C22.2, No. 248.15, LR700489 Self-Certified DC Ratings: Voltage Rating: TJN (15-1200) 160Vdc Interrupting Rating: TJN (15-600) TJN (601-1200) 20,000 Amps DC 100,000 Amps DC Recommended Fuse Blocks: Refer to page 131 in this catalog. Recommended Upgrade: None Available. Application Section Fuse Blocks, Holders & Misc. Medium Voltage Fuses Canadian Fuses & Holders Special Purpose Fuses UL/CSA Fuses General Purpose UL/CSA Fuses Current Limiting T T 22 For additional information, visit www.edisonfuse.com tn tn ses ses Circuit Protection Peak Let-Through Current Curve Cat. No. TJN (Amp) 3 2 1,000 800 600 400 300 A 200 1 AMP RATING 2,000 .8 .6 RMS SYMMETRICAL CURRENTS IN AMPS A-B = ASYMMETRICAL AVAILABLE PEAK (2.3 x SYMM RMS AMPS) .4 .3 .2 TJN Dimensions - in Canadian Fuses & Holders .1 .08 .06 0.88˝ .04 Medium Voltage Fuses 0.41˝ Dia. .03 1 to 30A 3.06˝ 2.03˝ 0.88˝ 0.88˝ .02 0.56˝ Dia. 1.25˝ RMS SYMMETRICAL CURRENT IN AMPS 8,000 10,000 6,000 4,000 3,000 2,000 600 400 300 200 80 100 60 40 30 800 1,000 35 to 60A .01 20 TIME IN SECONDS 4 4,000 3,000 200,000 6 60 30 15 60,000 80,000 100,000 10 8 10,000 8,000 6,000 30,000 40,000 20 400 200 100 20,000 20,000 30 6,000 8,000 10,000 40 1200 800 600 40,000 30,000 3,000 4,000 60 100,000 80,000 60,000 2,000 100 80 200,000 Special Purpose Fuses INSTANTANEOUS PEAK LET-THROUGH CURRENT IN AMPS 200 B 400,000 300,000 UL/CSA Fuses General Purpose 300 600 800 1,000 AMP RATING 300 400 600A 400A 200A 100A 60A 30A 15A Average Time-Current Curve Cat. No. TJN (Amp) 200 Class T ast Class T ast 100 a a UL/CSA Fuses Current Limiting T T 2.16˝ 1.56˝ 0.84˝ 450 to 600A 3.38˝ 2.22˝ 0.89˝ 0.75˝ 70 to 100A Fuse Blocks, Holders & Misc. 2.44˝ 1.69˝ 0.84˝ 1.75˝ 0.88˝ 601 to 800A 4˝ 2.53˝ 1.08˝ 110 to 200A 2.75˝ 1.84˝ 0.86˝ 2˝ 1˝ For additional information, visit www.edisonfuse.com 801 to 1200A Application Section 225 to 400A 23 tn tn ses ses Peak Let-Through Current Curve Cat. No. TJS (Amp) 20 4 3 2 1 .8 .6 .4 .3 .2 .1 .08 .06 400 20,000 200 100 60 10,000 8,000 6,000 30 4,000 3,000 2,000 1,000 800 600 400 300 A 300 400 100 200 .02 6,000 8,000 10,000 3,000 4,000 2,000 300 400 200 60 80 100 30 40 20 6 8 10 3 4 2 600 800 1,000 RMS SYMMETRICAL CURRENTS IN AMPS A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) .01 1 AMP RATING 40,000 30,000 .04 .03 Canadian Fuses & Holders 1200 800 600 200 TIME IN SECONDS Special Purpose Fuses 10 8 6 100,000 80,000 60,000 200,000 40 30 200,000 60,000 80,000 100,000 100 80 60 30,000 40,000 200 B 400,000 300,000 20,000 INSTANTANEOUS PEAK LET-THROUGH CURRENT IN AMPS UL/CSA Fuses General Purpose 300 6,000 8,000 10,000 AMP RATING 3,000 4,000 400A 500A 800A 200A 100A 60A 30A 15A 10A 5A 3A Average Time-Current Curve Cat. No. TJS (Amp) 2,000 Class T ast Class T ast 600 800 1,000 a a 1A UL/CSA Fuses Current Limiting T T CURRENT IN AMPS TJS Dimensions - inches 1.5" (± 0.04) Medium Voltage Fuses Dia. 0.56" (± 0.04) 3.63" (± 0.04) 2.72" 1.73" 1A to 30A 1" (± 0.04) 225A to 400A Dia. 0.81" (± 0.04) 1.00" (± 0.01) 2.95" (± 0.04) 2.36" 1.64" 450A to 600A Fuse Blocks, Holders & Misc. 4.33" (± 0.04) 3.17" 1.88" 70A to 100A 3.25" (± 0.04) 2.5" 1.66" 0.484" (Typ. 2) 1.75" (± 0.04) 0.88" (± 0.04) 110A to 200A Application Section 0.344" (Typ. 2) 24 0.406" (Typ. 2) 1.25" (± 0.04) 0.75" (± 0.04) 0.281" (Typ. 2) 3.98" (± 0.04) 2.95" 1.78" For additional information, visit www.edisonfuse.com 0.563" 601A to 800A (Typ. 2) e a ses Circuit Protection UL/CSA Fuses Current Limiting CT Class UL/CSA Fuses General Purpose Special Purpose Fuses Catalog Number SEC (0.5 - 60A) 600Vac or Less Amps 1 - 15 20 25 - 30 35 - 60 3 4 5 6 25 30 35 40 Dimensions - inches Ferrule Diameter 0.41 0.41 0.41 0.41 45 50 60 — Length 1.31 1.41 1.63 2.25 Voltage Rating: SEC 0.5 to 20 SEC 25 to 60 600Vac 480Vac Amp Rating: 0.5 to 6 Amps (fast-acting), 7 to 60 Amps (time-delay) Interrupting Rating: 100,000 RMS Symmetrical Amps Current Limiting: Class G Fuse Agency Approvals: UL Listed, Std. 248-5, Class G, Guide JDDZ, File E162363 CSA Certified, C22.2 No. 248.5, Class 1422-01, File 700489 *Fast-acting/time-delay varies by amp rating Recommended Fuse Blocks: Refer to page 133 in this catalog. Fuse Blocks, Holders & Misc. Benefits: • Branch circuit rated for 480Vac. • Compact size features varying length rejection feature which helps prevent overfusing. • Time-delay of 12 sec. min. at 200% rating for amp sizes 6 through 60. Medium Voltage Fuses Self-Certified DC Ratings: Voltage Rating: SEC (0.5-20A) 170Vdc; SEC (30 and 60A only) 300Vdc Interrupting Rating: 10,000 Amps DC Canadian Fuses & Holders .5 1 1.5 2 SEC Specifications Fast-Acting; Time-Delay* Amp Ratings SEC 8 10 15 20 Recommended Upgrade: None Available. Applications: • General purpose for use in 120/208 and 277/480 circuits. Ideal for fluorescent fixture protection. • Light inductive loads including motors, solenoids, etc. (For additional delay, refer to Edison EDCC or JDL). Application Section For additional information, visit www.edisonfuse.com 25 UL/CSA Fuses Current Limiting CT Class e a ses SEC TIME-LAG CLASS G FUSES UL/CSA Fuses General Purpose AMP RATING 20 25 30 15 6 8 10 4 3 1 .5 Average Time-Current Curve Cat. No. SEC (Amp) 100 Canadian Fuses & Holders TIME IN SECONDS Special Purpose Fuses 10 1 1000 10 1 .1 Medium Voltage Fuses .01 100 .1 CURRENT IN AMPS B 10,000 8,000 6,000 60 30 20 15 AMP RATING 4,000 3,000 2,000 1,000 800 600 60,000 80,000 100,000 30,000 40,000 20,000 8,000 10,000 6,000 2,000 4,000 2,000 600 800 1,000 300 400 100 200 400 300 A 200 100 Application Section Fuse Blocks, Holders & Misc. INSTANTANEOUS PEAK LET-THROUGH CURRENT IN AMPS Peak Let-Through Current Curve Cat. No. SEC (Amp) RMS SYMMETRICAL CURRENTS IN AMPS A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) 26 For additional information, visit www.edisonfuse.com ela ses Circuit Protection UL/CSA Fuses Current Limiting CC T e C CC UL/CSA Fuses General Purpose Amps 0.5 - 30 1.5 1.6 1.8 2 2.25 2.5 2.8 EDCC Specifications Time-Delay Amp Ratings EDCC 3 3.2 3.5 4 4.5 5 5.6 6 6.25 7 7.5 8 9 10 Dimensions - inches Ferrule 13/32 12 15 20 25 30 — — Length 1-1/2 EDCC - 600Vac Amp Rating: 0.5 - 30 Amps Interrupting Rating: 200,000 RMS Symmetrical Amps Current Limiting: Class CC Fuse Agency Approvals: UL Listed, Class CC, Guide JDDZ, File E162363 CSA Certified per C22.2, No. 248.4 UL Listed DC Rating: Voltage Rating: EDCC 0.5-2.8A, 20-30A 300Vdc 3-15A 150Vdc Interrupting Rating: 20,000 Amps DC Medium Voltage Fuses Edison EDCC Class CC fuses are extremely current-limiting fuses in a compact size. EDCC fuses are designed specifically for the protection of small horsepower motor circuits. Recommended sizing for most applications is 200% FLA. Refer to time-current curves for specific applications. Voltage Rating: Canadian Fuses & Holders 0.5 0.6 0.8 1 1.125 1.25 1.4 Special Purpose Fuses Catalog Number EDCC (0.5 - 30A) 600Vac or Less Recommended Fuse Blocks: Refer to page 134 in this catalog. Applications: • Use for protection of small horsepower motor circuits or other circuits requiring small dimension, time-delay fuses. • Can provide Type 2 “No Damage” protection for IEC or NEMA starters/contactors. • For control transformer applications, refer to HCTR. Recommended Upgrade: None Available. Fuse Blocks, Holders & Misc. Benefits: • Branch circuit rated for 600Vac. • Time-delay for motor branch circuit protection. • Excellent current-limiting performance. • Upgrade for standard “midget” fuses. Recommended Inline Fuse Holders: Refer to page 147 in this catalog. Application Section For additional information, visit www.edisonfuse.com 27 UL/CSA Fuses Current Limiting CC T e ela Class CC ses UL/CSA Fuses General Purpose AMP RATING 20 25 30 3 3.5 4 4.5 6 8 10 12 15 .5 .6 .8 1 1.25 Time- Current Characteristics Curve Average Melt EDCC Fuses 100 Canadian Fuses & Holders Special Purpose Fuses TIME IN SECONDS 10 1 Medium Voltage Fuses CURRENT IN AMPS 1000 100 .1 1 .01 10 .1 Current-Limiting Effects EDCC Fuse Rating Fuse Blocks, Holders & Misc. *Prospective ShortCircuit Current 1000 3000 5000 10,000 20,000 30,000 40,000 50,000 60,000 80,000 100,000 200,000 Let-Through Current (Apparent RMS Symmetrical) Versus Fuse Ratings 1.25A 2.8A 15A 20A 25A 100 135 240 305 380 140 210 350 440 575 165 255 420 570 690 210 340 540 700 870 260 435 680 870 1,090 290 525 800 1,030 1,300 315 610 870 1,150 1,390 340 650 915 1,215 1,520 350 735 1,050 1,300 1,650 390 785 1,130 1,500 1,780 420 830 1,210 1,600 2,000 525 1,100 1,600 2,000 2,520 Application Section *RMS Symmetrical amps short-circuit current. NOTE: To calculate Ip (Ipeak) multiply IRMS value x 2.3. 28 For additional information, visit www.edisonfuse.com 30A 435 580 710 1,000 1,305 1,520 1,700 1,820 1,980 2,180 2,400 3,050 t n Class CC ela Class CC ses ses Circuit Protection UL/CSA Fuses Current Limiting C ast CT T e UL/CSA Fuses General Purpose Amp Ratings 2.5 3 3.5 4 5 0.5 0.75 1 1.5 2 Amps Dimensions - inches Ferrule 0.1 - 30 13/32 6 7 8 9 10 12 15 20 25 30 Length 1-1/2 0.25 0.3 0.4 0.5 0.6 0.75 0.8 1 1.125 1.25 Amps 1.3 1.4 1.5 1.6 1.8 Amp Ratings 2 2.25 2.5 2.8 3 3.2 3.5 4 5 6 Dimensions - inches Ferrule 0.25 - 30 6.25 7.5 8 9 10 Length 13/32 HCTR Specifications Time-Delay Voltage Rating: HCLR - 600Vac Voltage Rating: HCTR - 600Vac Amp Rating: 0.1 - 30 Amps Amp Rating: 0.25 - 30 Amps 1-1/2 Interrupting Rating: 200,000 RMS Symmetrical Amps Interrupting Rating: 200,000 RMS Symmetrical Amps Current Limiting: Class CC Fuse Current Limiting: Class CC Fuse Medium Voltage Fuses HCLR Specifications Fast-Acting 12 15 20 25 30 Canadian Fuses & Holders 0.1 0.125 0.2 0.25 0.3 Catalog Number HCTR (0.25 - 30A) 600Vac or Less Time-Delay Special Purpose Fuses Catalog Number HCLR (0.1 - 30A) 600Vac or Less Fast-Acting Benefits: • Branch circuit rated for 600Vac. • Compact dimensions. • Fast-acting design responds quickly to both overload and short-circuit current. Benefits: • Branch circuit rated for 600Vac. • Compact dimensions. • Time-delay design allows closer sizing for inductive loads such as control transformers and solenoids. Applications: • Lighting and resistive heating loads. Applications: • Primary protection for control transformers. Recommended Fuse Blocks: Refer to page 134 in this catalog. Recommended Fuse Blocks: Refer to page 134 in this catalog. Application Section Agency Approvals: UL Listed, Class CC, Guide JDDZ, File E162363 CSA Certified per C22.2, No. 248.4 Recommended Inline Fuse Holders: Refer to page 147 in this catalog. Recommended Panel Mount Holders: Refer to page 150 in this catalog. For additional information, visit www.edisonfuse.com Fuse Blocks, Holders & Misc. Agency Approvals: UL Listed, Class CC, Guide JDDZ, File E162363 CSA Certified per C22.2, No. 248.4 29 t n Class CC ela Class CC ses ses UL/CSA Fuses General Purpose 300 7-1/2 5 3 1 1/2 AMP RATING 15A 20A 8A 10A 5A 3A 2A Average Time-Current Curve Cat. No. HCLR (Amp) Fast-Acting Cat. No. HCTR (Amp) Time-Delay 1A UL/CSA Fuses Current Limiting C ast CT T e AMP RATING 100 80 200 60 40 30 100 80 20 60 10 40 8 30 6 4 TIME IN SECONDS Special Purpose Fuses 20 10 8 6 TIME IN SECONDS 2 1 .8 4 .6 3 .4 2 .3 .2 1 .8 .1 .6 .08 .06 .4 .04 .3 .03 .2 .02 RMS SYMMETRICAL CURRENT IN AMPS .06 .04 .03 400 300 200 80 100 60 40 30 20 6 4 3 8 10 Fuse Blocks, Holders & Misc. 1 .01 2 .02 Application Section RMS SYMMETRICAL CURRENT IN AMPS 30 For additional information, visit www.edisonfuse.com 200 80 100 60 40 30 20 6 8 10 .08 4 3 2 .4 Medium Voltage Fuses .8 1 .01 .1 .6 Canadian Fuses & Holders 3