AVX M39006

MIL-PRF-39006 Series
Military Conventional Wet Tantalum
This data sheet contains the MIL-PRF-39006 ratings for which AVX is a
qualified approved supplier. This will be continually updated as the
qualification expands. For COTS-Plus equivalent ratings please refer to the
TWC data sheet located on the website.
This design is an axial leaded tubular case. It includes a welded tantalum can
and header assembly that provides a hermetic seal to withstand harsh
environments. The 1000 hour failure rates of 1%, 0.1% and 0.01%
correspond to “M”, “P”, and “R” respectively.
For details on testing conditions please refer to MIL-PRF-39006.
Currently qualified M39006 ratings include:
/22 “M” Level: 6V to 100V: dashes -0001 to -0200
/25 “M” Level: 25V to 100V: dashes -0033 to -0080
/30 “M” Level: 6V to 100V: dashes -0001 to -0200
/31 “M” Level: 25V to 100V: dashes -0033 to -0080
OUTLINE DIMENSIONS
E
L
W
E
F
D
Terminal welded
to case (T)
F 6.35 (0.250)
W 0.64 +0.05
(.025 +.002)
T 2.380 (.094)
-
+
Case
CASE DIMENSIONS: millimeters (inches)
DSCC
Case
Size
T1
T2
T3
T4
AVX
Case
Size
A
B
D
E
L
+0.79 (0.031)
-0.41 (0.016)
11.51 (0.453)
16.28 (0.641)
19.46 (0.766)
26.97 (1.062)
D
Basic Case
±0.41 (0.016)
4.78 (0.188)
7.14 (0.281)
9.52 (0.375)
9.52 (0.375)
D
Insulated Case
Max
5.56 (0.219)
7.92 (0.312)
10.31 (0.406)
10.31 (0.406)
E
±6.35 (0.250)
38.10
57.15
57.15
57.15
(1.500)
(2.250)
(2.250)
(2.250)
VOLTAGE RATINGS (Operating Temperature -55ºC to 125ºC)
Voltage (DC)
Rated Voltage: (Vr)
Derated Voltage: (Vc)
Surge Voltage: (Vs)
62 ■ MARCH 2013
85ºC
125ºC
85ºC
6
4
6.9
8
5
9.2
10
6
11.5
15
10
17.3
25
15
28.8
30
20
34.5
50
30
57.5
60
40
69
75
50
86.3
100
65
115
125
85
144
MIL-PRF-39006 Series
Military Conventional Wet Tantalum
HOW TO ORDER MILITARY M39006 PART NUMBER:
M39006
/22
–0081
–
Type / Military
Designator
Specification
Sheet
Number
Dash
Number
*H = High Vibration
(When Specified)
Not RoHS Compliant
*High vibration qualified parts are currently under development. Please contact the factory for additional details and availability.
RIPPLE CURRENT MULTIPLIERS
Frequency of
Applied
Ripple Current
Ambient Still Air
Temperature (ºC)
% of
100%
85ºC
90%
Rated
80%
Peak
70%
Voltage 66-2/3%
Frequency of
Applied
Ripple Current
Ambient Still Air
Temperature (ºC)
% of
100%
85ºC
90%
Rated
80%
Peak
70%
Voltage 66-2/3%
vs. Frequency, temperature and applied voltage1/ 2/ 3/
120Hz
800Hz
1kHz
≤55
85
105
125
≤55
85
105
125
≤55
85
105
125
0.60
0.60
0.60
0.60
0.60
0.39
0.46
0.52
0.58
0.60
–
–
0.35
0.44
0.46
–
–
–
–
0.27
0.71
0.71
0.71
0.71
0.71
0.43
0.55
0.62
0.69
0.71
–
–
0.42
0.52
0.55
–
_
–
–
0.32
0.72
0.72
0.72
0.72
0.72
0.45
0.55
0.62
0.70
0.72
–
–
0.42
0.52
0.55
–
–
–
–
0.32
10kHz
40kHz
100kHz
≤55
85
105
125
≤55
85
105
125
≤55
85
105
125
0.88
0.88
0.88
0.88
0.88
0.55
0.67
0.76
0.85
0.88
–
–
0.52
0.64
0.68
–
–
–
–
0.40
1.00
1.00
1.00
1.00
1.00
0.63
0.77
0.87
0.97
1.00
–
–
0.59
0.73
0.77
–
_
–
–
0.45
1.10
1.10
1.10
1.10
1.10
0.69
0.85
0.96
1.07
1.10
–
–
0.65
0.80
0.85
–
–
–
–
0.50
1/ At 125ºC the rated voltage of the capacitors decreases to 66 2/3 of the 85ºC rated voltage.
2/ The peak of the applied ac ripple voltage plus the applied dc voltage must not exceed the dc voltage rating of the capacitors.
3/ The ripple current listed in the parametric tables represents a rating calculated by using a maximum internal temperature rise (ΔT) at
50°C at 40 kHz at 85°C ambient temperature, with a maximum peak rated voltage of 66.67 percent of the 85°C peak voltage rating.
MARCH 2013
■ 63
MIL-PRF-39006 Series
Military Conventional Wet Tantalum
M39006 /22 RATINGS AND DASH NUMBER REFERENCE
M39006/22
“M” Level
Reliability Tolerance ±
(%)
Dash
Numbers
-0001
20
-0002
10
-0003
5
-0004
20
-0005
10
-0006
5
-0007
20
-0008
10
-0009
5
-0010
20
-0011
10
-0012
5
-0013
20
-0014
10
-0015
5
-0016
20
-0017
10
-0018
5
-0019
20
-0020
10
-0021
20
-0022
10
-0023
5
-0024
20
-0025
10
-0026
5
-0027
20
-0028
10
-0029
5
-0030
20
-0031
10
-0032
5
-0033
20
-0034
10
-0035
5
-0036
20
-0037
10
-0038
5
-0039
20
-0040
10
-0041
20
-0042
10
-0043
5
-0044
20
-0045
10
-0046
5
-0047
20
-0048
10
-0049
5
-0050
20
-0051
10
-0052
5
-0053
20
-0054
10
-0055
5
-0056
20
-0057
10
-0058
5
-0059
20
-0060
10
-0061
20
-0062
10
-0063
5
-0064
20
-0065
10
-0066
5
Cap
(uF)
25°C
at
120Hz
DC Rated
Voltage
(V)
at
85ºC
30
DC Leakage (uA)
DF
max
(%)
ESR
max
(Ohms)
at
120Hz
Impedance
max
(Ohms)
-55ºC at
120Hz
+25ºC
+85ºC
&
125ºC
6
1
2
9
3.98
68
6
1
2
15
140
6
1
3
270
6
1
330
6
560
Maximum Capacitance
Change (%)
Case
Size
Standard
-55ºC
+85ºC
+125ºC
100
-40
10.5
12
820
T1
3.16
60
-40
14
16
960
T1
21
1.99
40
-40
14
16
1200
T2
6.5
45
2.21
25
-44
17.5
20
1375
T2
2
7.9
36
1.45
20
-44
14
16
1800
T3
6
2
13
55
1.3
25
-64
17.5
20
1900
T3
1200
6
3
14
90
1
20
-80
25
25
2265
T4
25
8
1
2
7.5
3.98
100
-40
10.5
12
820
T1
56
8
1
2
14
3.32
59
-40
14
16
900
T1
120
8
1
2
20
2.21
50
-44
17.5
20
1220
T2
220
8
1
7
37
2.23
30
-44
17.5
20
1370
T2
290
8
2
6
34
1.56
25
-64
17.5
20
1770
T3
430
8
2
14
46
1.42
25
-64
17.5
20
1825
T3
850
8
4
16
60
0.94
22
-80
25
25
2330
T4
20
10
1
2
6
3.98
175
-32
10.5
12
820
T1
47
10
1
2
13
3.67
100
-36
14
16
855
T1
100
10
1
4
15
1.99
60
-36
14
16
1200
T2
180
10
1
7
30
2.21
40
-36
14
16
1.365
T2
250
10
2
10
30
1.59
30
-40
14
16
1720
T3
390
10
2
16
44
1.5
25
-64
17.5
20
1800
T3
750
10
4
16
50
0.88
23
-80
25
25
2360
T4
15
15
1
2
5
4.42
155
-24
10.5
12
780
T1
33
15
1
2
10
4.02
90
-28
14
16
820
T1
All technical data relates to an ambient temperature of +25ºC. Capacitance and DF are measured at 120Hz, 0.5RMS with DC bias of 2.2V.
DCL is measured at rated voltage after 5 minutes.
64 ■ MARCH 2013
AC Ripple
(mA rms)
85ºC
at
40kHz
MIL-PRF-39006 Series
Military Conventional Wet Tantalum
M39006/22
“M” Level
Reliability Tolerance ±
(%)
Dash
Numbers
-0067
20
-0068
10
-0069
5
-0070
20
-0071
10
-0072
5
-0073
20
-0074
10
-0075
5
-0076
20
-0077
10
-0078
5
-0079
20
-0080
10
-0081
20
-0082
10
-0083
5
-0084
20
-0085
10
-0086
5
-0087
20
-0088
10
-0089
5
-0090
20
-0091
10
-0092
5
-0093
20
-0094
10
-0095
5
-0096
20
-0097
10
-0098
5
-0099
20
-0100
10
-0101
20
-0102
10
-0103
5
-0104
20
-0105
10
-0106
5
-0107
20
-0108
10
-0109
5
-0110
20
-0111
10
-0112
5
-0113
20
-0114
10
-0115
5
-0116
20
-0117
10
-0118
5
-0119
20
-0120
10
-0121
20
-0122
10
-0123
5
-0124
20
-0125
10
-0126
5
-0127
20
-0128
10
-0129
5
-0130
20
-0131
10
-0132
5
-0133
20
-0134
10
-0135
5
Cap
(uF)
25°C
at
120Hz
DC Rated
Voltage
(V)
at
85C
70
DC Leakage (uA)
DF
max
(%)
ESR
max
(Ohms)
at
120Hz
Impedance
max
(Ohms)
-55ºC at
120Hz
+25ºC
+85ºC
&
125ºC
15
1
4
13
2.46
120
15
1
7
18
170
15
2
10
270
15
2
540
15
10
Maximum Capacitance
Change (%)
AC Ripple
(mA rms)
85ºC
at
40kHz
Case
Size
Standard
-55ºC
+85ºC
+125ºC
75
-28
14
16
1150
T2
1.99
50
-28
17.5
20
1450
T2
25
1.95
35
-32
14
16
1480
T3
16
32
1.57
30
-56
17.5
20
1740
T3
6
24
40
0.98
23
-80
25
25
2330
T4
25
1
2
4
5.31
220
-16
8
9
715
T1
22
25
1
2
6.6
3.98
140
-20
10.5
12
825
T1
50
25
1
2
11
2.92
70
-28
13
15
1130
T2
100
25
1
10
15
1.99
50
-28
13
15
1435
T2
120
25
2
6
21
2.32
38
-32
13
15
1450
T3
180
25
2
18
26
1.92
32
-48
13
15
1525
T3
350
25
7
28
35
1.33
24
-70
25
25
1970
T4
8
30
1
2
4
6.64
275
-16
8
12
640
T1
15
30
1
2
5
4.42
175
-20
10.5
12
780
T1
40
30
1
5
10
3.32
65
-24
10.5
12
1120
T2
68
30
1
8
13
2.54
60
-24
13
15
1285
T2
100
30
2
12
17
2.26
40
-28
10.5
12
1450
T3
150
30
2
18
23
2.03
35
-48
13
15
1525
T3
300
30
8
32
31
1.37
25
-60
25
25
1950
T4
5
50
1
2
3
7.96
400
-16
5
6
580
T1
10
50
1
2
4
5.31
250
-24
8
9
715
T1
25
50
1
5
8
4.25
95
-20
10.5
12
1005
T2
47
50
1
9
11
3.11
70
-28
13
15
1155
T2
60
50
2
12
12
2.65
45
-16
10.5
12
1335
T3
All technical data relates to an ambient temperature of +25ºC. Capacitance and DF are measured at 120Hz, 0.5RMS with DC bias of 2.2V.
DCL is measured at rated voltage after 5 minutes.
MARCH 2013
■ 65
MIL-PRF-39006 Series
Military Conventional Wet Tantalum
M39006/22
“M” Level
Reliability Tolerance ±
(%)
Dash
Numbers
-0136
20
-0137
10
-0138
5
-0139
20
-0140
10
-0141
20
-0142
10
-0143
5
-0144
20
-0145
10
-0146
5
-0147
20
-0148
10
-0149
5
-0150
20
-0151
10
-0152
5
-0153
20
-0154
10
-0155
5
-0156
20
-0157
10
-0158
5
-0159
20
-0160
10
-0161
20
-0162
10
-0163
5
-0164
20
-0165
10
-0166
5
-0167
20
-0168
10
-0169
5
-0170
20
-0171
10
-0172
5
-0173
20
-0174
10
-0175
5
-0176
20
-0177
10
-0178
5
-0179
20
-0180
10
-0181
20
-0182
10
-0183
5
-0184
20
-0185
10
-0186
5
-0187
20
-0188
10
-0189
5
-0190
20
-0191
10
-0192
5
-0193
20
-0194
10
-0195
5
-0196
20
-0197
10
-0198
5
-0199
20
-0200
10
Cap
(uF)
25°C
at
120Hz
DC Rated
Voltage
(V)
at
85C
82
DC Leakage (uA)
DF
max
(%)
ESR
max
(Ohms)
at
120Hz
Impedance
max
(Ohms)
-55ºC at
120Hz
+25ºC
+85ºC
&
125ºC
50
2
16
15
2.43
160
50
8
32
17
4
60
1
2
8.2
60
1
20
60
39
Maximum Capacitance
Change (%)
Case
Size
Standard
-55ºC
+85ºC
+125ºC
45
-32
13
15
1400
T3
1.41
27
-50
25
25
1900
T4
2.8
9.29
550
-16
5
6
525
T1
2
4
6.47
275
-24
8
9
625
T1
1
5
7
4.64
105
-16
10.5
12
930
T2
60
1
9
10
3.4
90
-28
10.5
12
1110
T2
50
60
2
12
10
2.65
50
-16
10.5
12
1330
T3
68
60
2
16
13
2.54
50
-32
10.5
12
1365
T3
140
60
8
32
16
1.52
28
-40
20
20
1850
T4
3.5
75
1
2
2.5
9.48
650
-16
5
6
525
T
6.8
75
1
2
3.5
6.83
300
-20
8
9
610
T1
15
75
1
5
6
5.31
150
-16
8
9
890
T2
33
75
1
10
10
4.02
90
-24
10.5
15
1000
T2
40
75
2
12
9
2.99
60
-16
10.5
12
1250
T3
56
75
2
17
11
2.61
60
-28
10.5
15
1335
T3
110
75
9
36
12
1.45
29
-35
20
20
1850
T4
2.5
100
1
2
2
10.62
950
-16
7
8
505
T1
4.7
100
1
2
3
8.47
500
-16
7
8
565
T1
11
100
1
4
5
6.03
200
-16
8
8
835
T2
22
100
1
9
7.5
4.52
100
-16
8
8
965
T2
30
100
2
12
7
3.1
80
-16
8
8
1240
T3
43
100
2
17
8.5
2.62
70
-20
8
8
1335
T3
86
100
9
36
10
1.54
30
-25
15
15
1800
T4
All technical data relates to an ambient temperature of +25ºC. Capacitance and DF are measured at 120Hz, 0.5RMS with DC bias of 2.2V.
DCL is measured at rated voltage after 5 minutes.
66 ■ MARCH 2013
AC Ripple
(mA rms)
85ºC
at
40kHz
MIL-PRF-39006 Series
Military Conventional Wet Tantalum
M39006 /25 RATINGS AND DASH NUMBER REFERENCE
M39006/25
“M” Level
Reliability Tolerance ±
(%)
Dash
Numbers
-0033
20
-0034
10
-0035
20
-0036
10
-0037
20
-0038
10
-0039
20
-0040
10
-0041
20
-0042
10
-0043
20
-0044
10
-0045
20
-0046
10
-0047
20
-0048
10
-0049
20
-0050
10
-0051
20
-0052
10
-0053
20
-0054
10
-0055
20
-0056
10
-0057
20
-0058
10
-0059
20
-0060
10
-0061
20
-0062
10
-0063
20
-0064
10
-0065
20
-0066
10
-0067
20
-0068
10
-0069
20
-0070
10
-0071
20
-0072
10
-0073
20
-0074
10
-0075
20
-0076
10
-0077
20
-0078
10
-0079
20
-0080
10
Cap
(uF)
25°C
at
120Hz
DC Rated
Voltage
(V)
at
85ºC
68
DC Leakage (uA)
DF
max
(%)
ESR
max
(Ohms)
at
120Hz
Impedance
max
(Ohms)
-55ºC at
120Hz
+25ºC
+85ºC
&
125ºC
25
2
9
22
4.29
270
25
3
16
55
560
25
7
28
680
25
8
56
30
220
Maximum Capacitance
Change (%)
AC Ripple
(mA rms)
85ºC
at
40kHz
Case
Size
Standard
-55ºC
+85ºC
+125ºC
90
-40
12
15
850
T1
2.7
33
-62
13
16
1400
T2
76
1.8
24
-72
20
25
1750
T3
32
63
1.23
19
-72
25
30
2100
T4
2
9
22
5.21
100
-38
12
15
800
T1
30
3
16
42
2.53
36
-60
13
16
1200
T2
470
30
8
32
64
1.81
25
-65
20
25
1500
T3
560
30
9
36
55
1.3
20
-65
25
30
2000
T4
33
50
2
9
12.3
4.95
135
-29
10
12
700
T1
120
50
4
24
22.5
2.49
49
-42
12
15
1200
T2
270
50
8
32
37
1.82
29
-46
20
25
1450
T3
330
50
9
36
38
1.53
22
-46
25
30
1900
T4
27
60
3
12
10.2
5.01
144
-24
10
12
700
T1
100
60
4
20
19
2.52
54
-36
12
15
1100
T2
220
60
8
32
30
1.81
29
-40
16
20
1400
T3
270
60
9
36
27
1.33
23
-45
20
25
1850
T4
22
75
3
12
8.5
5.13
157
-19
10
12
600
T1
82
75
4
24
15.2
2.46
63
-30
12
15
1000
T2
180
75
9
36
24.4
2.23
30
-35
16
20
1300
T3
220
75
10
40
37
1.8
24
-40
20
25
1800
T4
10
100
3
12
4.5
5.97
200
-17
10
12
800
T1
39
100
5
24
10.4
3.54
80
-20
12
15
1300
T2
68
100
10
40
11.3
2.21
40
-30
14
16
1600
T3
120
100
12
48
25
2.76
30
-35
15
17
2000
T4
All technical data relates to an ambient temperature of +25ºC. Capacitance and DF are measured at 120Hz, 0.5RMS with DC bias of 2.2V.
DCL is measured at rated voltage after 5 minutes.
MARCH 2013
■ 67
MIL-PRF-39006 Series
Military Conventional Wet Tantalum
M39006 /30 RATINGS AND DASH NUMBER REFERENCE
M39006/30
“M” Level
Reliability Tolerance ±
(%)
Dash
Numbers
-0001
20
-0002
10
-0003
5
-0004
20
-0005
10
-0006
5
-0007
20
-0008
10
-0009
5
-0010
20
-0011
10
-0012
5
-0013
20
-0014
10
-0015
5
-0016
20
-0017
10
-0018
5
-0019
20
-0020
10
-0021
20
-0022
10
-0023
5
-0024
20
-0025
10
-0026
5
-0027
20
-0028
10
-0029
5
-0030
20
-0031
10
-0032
5
-0033
20
-0034
10
-0035
5
-0036
20
-0037
10
-0038
5
-0039
20
-0040
10
-0041
20
-0042
10
-0043
5
-0044
20
-0045
10
-0046
5
-0047
20
-0048
10
-0049
5
-0050
20
-0051
10
-0052
5
-0053
20
-0054
10
-0055
5
-0056
20
-0057
10
-0058
5
-0059
20
-0060
10
-0061
20
-0062
10
-0063
5
-0064
20
-0065
10
-0066
5
Cap
(uF)
25°C
at
120Hz
DC Rated
Voltage
(V)
at
85ºC
30
DC Leakage (uA)
DF
max
(%)
ESR
max
(Ohms)
at
120Hz
Impedance
max
(Ohms)
-55ºC at
120Hz
+25ºC
+85ºC
&
125ºC
6
1
2
4.5
1.99
68
6
1
2
7.5
140
6
1
3
270
6
1
330
6
560
Maximum Capacitance
Change (%)
Case
Size
Standard
-55ºC
+85ºC
+125ºC
100
-40
10.5
12
820
T1
1.58
60
-40
14
16
960
T1
10.5
0.99
40
-40
14
16
1200
T2
6.5
22.5
1.11
25
-44
17.5
20
1375
T2
2
7.9
18
0.73
20
-44
14
16
1800
T3
6
2
13
27.5
0.65
25
-64
17.5
20
1900
T3
1200
6
3
14
45
0.5
20
-80
25
25
2265
T4
25
8
1
2
3.75
1.99
100
-40
10.5
12
820
T1
56
8
1
2
7
1.66
59
-40
14
16
900
T1
120
8
1
2
10
1.11
50
-44
17.5
20
1220
T2
220
8
1
7
18.5
1.12
30
-44
17.5
20
1370
T2
290
8
2
6
17
0.78
25
-64
17.5
20
1770
T3
430
8
2
14
23
0.71
25
-64
17.5
20
1825
T3
850
8
4
16
30
0.47
22
-80
25
25
2330
T4
20
10
1
2
3
1.99
175
-32
10.5
12
820
T1
47
10
1
2
6.5
1.84
100
-36
14
16
855
T1
100
10
1
4
7.5
0.99
60
-36
14
16
1200
T2
180
10
1
7
15
1.11
40
-36
14
16
1.365
T2
250
10
2
10
15
0.8
30
-40
14
16
1720
T3
390
10
2
16
22
0.75
25
-64
17.5
20
1800
T3
750
10
4
16
25
0.44
23
-80
25
25
2360
T4
15
15
1
2
2.5
2.21
155
-24
10.5
12
780
T1
33
15
1
2
5
2.01
90
-28
14
16
820
T1
All technical data relates to an ambient temperature of +25ºC. Capacitance and DF are measured at 120Hz, 0.5RMS with DC bias of 2.2V.
DCL is measured at rated voltage after 5 minutes.
68 ■ MARCH 2013
AC Ripple
(mA rms)
85ºC
at
40kHz
MIL-PRF-39006 Series
Military Conventional Wet Tantalum
M39006/30
“M” Level
Reliability Tolerance ±
(%)
Dash
Numbers
-0067
20
-0068
10
-0069
5
-0070
20
-0071
10
-0072
5
-0073
20
-0074
10
-0075
5
-0076
20
-0077
10
-0078
5
-0079
20
-0080
10
-0081
20
-0082
10
-0083
5
-0084
20
-0085
10
-0086
5
-0087
20
-0088
10
-0089
5
-0090
20
-0091
10
-0092
5
-0093
20
-0094
10
-0095
5
-0096
20
-0097
10
-0098
5
-0099
20
-0100
10
-0101
20
-0102
10
-0103
5
-0104
20
-0105
10
-0106
5
-0107
20
-0108
10
-0109
5
-0110
20
-0111
10
-0112
5
-0113
20
-0114
10
-0115
5
-0116
20
-0117
10
-0118
5
-0119
20
-0120
10
-0121
20
-0122
10
-0123
5
-0124
20
-0125
10
-0126
5
-0127
20
-0128
10
-0129
5
-0130
20
-0131
10
-0132
5
-0133
20
-0134
10
-0135
5
Cap
(uF)
25°C
at
120Hz
DC Rated
Voltage
(V)
at
85ºC
70
DC Leakage (uA)
DF
max
(%)
ESR
max
(Ohms)
at
120Hz
Impedance
max
(Ohms)
-55ºC at
120Hz
+25ºC
+85ºC
&
125ºC
15
1
4
6.5
1.23
120
15
1
7
9
170
15
2
10
270
15
2
540
15
10
Maximum Capacitance
Change (%)
AC Ripple
(mA rms)
85ºC
at
40kHz
Case
Size
Standard
-55ºC
+85ºC
+125ºC
75
-28
14
16
1150
T2
0.99
50
-28
17.5
20
1450
T2
12.5
0.98
35
-32
14
16
1480
T3
16
16
0.79
30
-56
17.5
20
1740
T3
6
24
20
0.49
23
-80
25
25
2330
T4
25
1
2
2
2.66
220
-16
8
9
715
T1
22
25
1
2
3.3
1.99
140
-20
10.5
12
825
T1
50
25
1
2
5.5
1.46
70
-28
13
15
1130
T2
100
25
1
10
7.5
0.99
50
-28
13
15
1435
T2
120
25
2
6
10.5
1.16
38
-32
13
15
1450
T3
180
25
2
18
13
0.96
32
-48
13
15
1525
T3
350
25
7
28
17.5
0.67
24
-70
25
25
1970
T4
8
30
1
2
2
3.32
275
-16
8
12
640
T1
15
30
1
2
2.5
2.21
175
-20
10.5
12
780
T1
40
30
1
5
5
1.66
65
-24
10.5
12
1120
T2
68
30
1
8
6.5
1.27
60
-24
13
15
1285
T2
100
30
2
12
8.5
1.13
40
-28
10.5
12
1450
T3
150
30
2
18
11.5
1.02
35
-48
13
15
1525
T3
300
30
8
32
15.5
0.69
25
-60
25
25
1950
T4
5
50
1
2
1.5
3.98
400
-16
5
6
580
T1
10
50
1
2
2
2.66
250
-24
8
9
715
T1
25
50
1
5
4
2.13
95
-20
10.5
12
1005
T2
47
50
1
9
5.5
1.56
70
-28
13
15
1155
T2
60
50
2
12
6
1.33
45
-16
10.5
12
1335
T3
All technical data relates to an ambient temperature of +25ºC. Capacitance and DF are measured at 120Hz, 0.5RMS with DC bias of 2.2V.
DCL is measured at rated voltage after 5 minutes.
MARCH 2013
■ 69
MIL-PRF-39006 Series
Military Conventional Wet Tantalum
M39006/30
“M” Level
Reliability Tolerance ±
(%)
Dash
Numbers
-0136
20
-0137
10
-0138
5
-0139
20
-0140
10
-0141
20
-0142
10
-0143
5
-0144
20
-0145
10
-0146
5
-0147
20
-0148
10
-0149
5
-0150
20
-0151
10
-0152
5
-0153
20
-0154
10
-0155
5
-0156
20
-0157
10
-0158
5
-0159
20
-0160
10
-0161
20
-0162
10
-0163
5
-0164
20
-0165
10
-0166
5
-0167
20
-0168
10
-0169
5
-0170
20
-0171
10
-0172
5
-0173
20
-0174
10
-0175
5
-0176
20
-0177
10
-0178
5
-0179
20
-0180
10
-0181
20
-0182
10
-0183
5
-0184
20
-0185
10
-0186
5
-0187
20
-0188
10
-0189
5
-0190
20
-0191
10
-0192
5
-0193
20
-0194
10
-0195
5
-0196
20
-0197
10
-0198
5
-0199
20
-0200
10
Cap
(uF)
25°C
at
120Hz
DC Rated
Voltage
(V)
at
85ºC
82
DC Leakage (uA)
DF
max
(%)
ESR
max
(Ohms)
at
120Hz
Impedance
max
(Ohms)
-55ºC at
120Hz
+25ºC
+85ºC
&
125ºC
50
2
16
7.5
1.22
160
50
8
32
8.5
4
60
1
2
8.2
60
1
20
60
39
Maximum Capacitance
Change (%)
Case
Size
Standard
-55ºC
+85ºC
+125ºC
45
-32
13
15
1400
T3
0.71
27
-50
25
25
1900
T4
1.4
4.65
550
-16
5
6
525
T1
2
2
3.24
275
-24
8
9
625
T1
1
5
3.5
2.32
105
-16
10.5
12
930
T2
60
1
9
5
1.7
90
-28
10.5
12
1110
T2
50
60
2
12
5
1.33
50
-16
10.5
12
1330
T3
68
60
2
16
6.5
1.27
50
-32
10.5
12
1365
T3
140
60
8
32
8
0.76
28
-40
20
20
1850
T4
3.5
75
1
2
1.25
4.74
650
-16
5
6
525
T1
6.8
75
1
2
1.75
3.42
300
-20
8
9
610
T1
15
75
1
5
3
2.66
150
-16
8
9
890
T2
33
75
1
10
5
2.01
90
-24
10.5
15
1000
T2
40
75
2
12
4.5
1.5
60
-16
10.5
12
1250
T3
56
75
2
17
5.5
1.31
60
-28
10.5
15
1335
T3
110
75
9
36
6
0.73
29
-35
20
20
1850
T4
2.5
100
1
2
1
5.31
950
-16
7
8
505
T1
4.7
100
1
2
1.5
4.24
500
-16
7
8
565
T1
11
100
1
4
2.5
3.02
200
-16
8
8
835
T2
22
100
1
9
3.75
2.26
100
-16
8
8
965
T2
30
100
2
12
3.5
1.55
80
-16
8
8
1240
T3
43
100
2
17
4.25
1.31
70
-20
8
8
1335
T3
86
100
9
36
5
0.77
30
-25
15
15
1800
T4
All technical data relates to an ambient temperature of +25ºC. Capacitance and DF are measured at 120Hz, 0.5RMS with DC bias of 2.2V.
DCL is measured at rated voltage after 5 minutes.
70 ■ MARCH 2013
AC Ripple
(mA rms)
85ºC
at
40kHz
MIL-PRF-39006 Series
Military Conventional Wet Tantalum
M39006 /31 RATINGS AND DASH NUMBER REFERENCE
M39006/31
“M” Level
Reliability Tolerance ±
(%)
Dash
Numbers
-0033
20
-0034
10
-0035
20
-0036
10
-0037
20
-0038
10
-0039
20
-0040
10
-0041
20
-0042
10
-0043
20
-0044
10
-0045
20
-0046
10
-0047
20
-0048
10
-0049
20
-0050
10
-0051
20
-0052
10
-0053
20
-0054
10
-0055
20
-0056
10
-0057
20
-0058
10
-0059
20
-0060
10
-0061
20
-0062
10
-0063
20
-0064
10
-0065
20
-0066
10
-0067
20
-0068
10
-0069
20
-0070
10
-0071
20
-0072
10
-0073
20
-0074
10
-0075
20
-0076
10
-0077
20
-0078
10
-0079
20
-0080
10
Cap
(uF)
25°C
at
120Hz
DC Rated
Voltage
(V)
at
85ºC
68
DC Leakage (uA)
DF
max
(%)
ESR
max
(Ohms)
at
120Hz
Impedance
max
(Ohms)
-55ºC at
120Hz
+25ºC
+85ºC
&
125ºC
25
2
9
11
2.15
270
25
3
16
27.5
560
25
7
28
680
25
8
56
30
220
Maximum Capacitance
Change (%)
AC Ripple
(mA rms)
85ºC
at
40kHz
Case
Size
Standard
-55ºC
+85ºC
+125ºC
90
-40
12
15
850
T1
1.35
33
-62
13
16
1400
T2
38
0.9
24
-72
20
25
1750
T3
32
31.5
0.62
19
-72
25
30
2100
T4
2
9
11
2.61
100
-38
12
15
800
T1
30
3
16
21
1.27
36
-60
13
16
1200
T2
470
30
8
32
32
0.91
25
-65
20
25
1500
T3
560
30
9
36
27.5
0.65
20
-65
25
30
2000
T4
33
50
2
9
6.15
2.48
135
-29
10
12
700
T1
120
50
4
24
11.3
1.25
49
-42
12
15
1200
T2
270
50
8
32
18.5
0.91
29
-46
20
25
1450
T3
330
50
9
36
19
0.77
22
-46
25
30
1900
T4
27
60
3
12
5.1
2.51
144
-24
10
12
700
T1
100
60
4
20
9.5
1.26
54
-36
12
15
1100
T2
220
60
8
32
15
0.91
29
-40
16
20
1400
T3
270
60
9
36
13.5
0.67
23
-45
20
25
1850
T4
22
75
3
12
4.25
2.57
157
-19
10
12
600
T1
82
75
4
24
7.6
1.23
63
-30
12
15
1000
T2
180
75
9
36
12.2
0.9
30
-35
16
20
1300
T3
220
75
10
40
18.5
1.12
24
-40
20
25
1800
T4
10
100
3
12
2.25
2.99
200
-17
10
12
800
T1
39
100
5
24
5.2
1.77
80
-20
12
15
1300
T2
68
100
10
40
5.65
1.11
40
-30
14
16
1600
T3
120
100
12
48
12.5
1.38
30
-35
15
17
2000
T4
All technical data relates to an ambient temperature of +25ºC. Capacitance and DF are measured at 120Hz, 0.5RMS with DC bias of 2.2V.
DCL is measured at rated voltage after 5 minutes.
MARCH 2013
■ 71