M39006/22, M39006/25 www.vishay.com Vishay Wet Tantalum Capacitors, Military Established Reliability, MIL-PRF-39006/22/25 Qualified Styles CLR79, CLR81 FEATURES • Hermetically sealed • Metal cased • Axial lead • Tubular STYLE, MILITARY SPECIFICATION • CLR79, M39006/22 MIL-PRF-39006/22 • CLR81, M39006/25 MIL-PRF-39006/25 PERFORMANCE CHARACTERISTICS Operating Temperature: - 55 °C to + 125 °C Capacitance Range: M39006/22 - 1.7 μF to 1200 μF; M39006/25 - 6.8 μF to 2200 μF Capacitance Tolerance: ± 5 %, ± 10 %, ± 20 % Voltage Rating: 6 VDC to 125 VDC Established Reliability Tantalum Capacitors to Military Specification MIL-PRF-39006: In accordance with the military specification MIL-PRF-39006 all capacitors are marked with the military part number (M39006/xx-xxxx) rather than the older style designation (CLR79, CLR81) and should be ordered as such. For information on the performance characteristics of these capacitors, please refer to the latest issue of the Military Specification. MIL-PRF-39006 establishes 1000 h failure rate levels of 1 %, 0.1 %, and 0.01 %. When ordering these parts, care must be exercised that the correct part number expressing the appropriate failure level be specified. Each order for military style capacitors requiring government inspection must state whether inspection is to be at the destination or at the Vishay plant. Orders requiring source inspection cannot be shipped until this has been accomplished. ORDERING INFORMATION M39006 /22 -0441 H BASIC DOCUMENT NUMBER SLASH SHEET DASH NUMBER DESIGNATION OF HIGH VIBRATION (OPTIONAL) Indicates the basic specification; in this case MIL-PRF-39006 Indicates the specification sheet of the basic military specification Taken from Standard/ Extended Ratings tables H, optional, if specified Revison: 28-Aug-12 Document Number: 40022 1 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 M39006/22, M39006/25 www.vishay.com Vishay DIMENSIONS in inches [millimeters] Tantalum feed-through 0.078 [1.98] max. dia. Style CLR79 Style CLR81 Term. loc. within 0.031 [0.79] R of true position 0.250 [6.35] max. Terminal welded to case - + D dia. 0.094 [2.38] max. External weld E L E Case Circuit diagram 0.025 ± 0.002 [0.64 ± 0.05] Glass Insulating sleeve BARE CASE CASE CODE T1 T2 T3 T4 WITH INSULATING SLEEVE D L D (Max.) L (Max.) E LEAD LENGTH 0.188 ± 0.016 [4.78 ± 0.41] 0.281 ± 0.016 [7.14 ± 0.41] 0.375 ± 0.016 [9.53 ± 0.41] 0.375 ± 0.016 [9.53 ± 0.41] 0.453 + 0.031/- 0.016 [11.51 + 0.79/- 0.41] 0.641 + 0.031/- 0.016 [16.28 + 0.79/- 0.41] 0.766 + 0.031/- 0.016 [19.46 + 0.79/- 0.41] 1.062 + 0.031/- 0.016 [26.97 + 0.79/- 0.41] 0.219 [5.56] 0.312 [7.92] 0.406 [10.31] 0.406 [10.31] 0.515 [13.08] 0.704 [17.88] 0.828 [21.03] 1.126 [28.60] 1.500 ± 0.250 [38.10 ± 6.35] 2.250 ± 0.250 [57.15 ± 6.35] 2.250 ± 0.250 [57.15 ± 6.35] 2.250 ± 0.250 [57.15 ± 6.35] WEIGHT (oz./g) (Max.) 0.09 [2.6] 0.22 [6.2] 0.41 [11.6] 0.62 [17.7] RATINGS AND CASE CODES - M39006/22 μF 1.7 2.5 3.5 3.6 4.0 4.7 5.0 6.8 8.0 8.2 9.0 10 11 14 15 18 20 22 25 30 33 39 40 43 47 50 56 60 68 70 82 6 8 10 15 25 30 50 60 75 100 125 T1 T1 T1 T1 T1 T1 T1 T1 T1 T1 T2 T1 T1 T2 T2 T1 T1 T2 T3 T1 T2 T1 T2 T1 T2 T3 T1 T3 T1 T2 T2 T2 T3 T3 T1 T2 T2 T3 T1 T3 T4 T3 T1 Revison: 28-Aug-12 T2 T3 T2 T3 Document Number: 40022 2 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 M39006/22, M39006/25 www.vishay.com Vishay RATINGS AND CASE CODES - M39006/22 μF 86 100 110 120 140 150 160 170 180 220 250 270 290 300 330 350 390 430 540 560 750 850 1200 6 8 10 15 T2 25 30 T2 T3 50 60 75 100 T4 125 100 125 T1 T4 T2 T2 T3 T2 T4 T3 T4 T3 T2 T3 T2 T3 T2 T3 T3 T4 T3 T4 T3 T3 T4 T3 T4 T4 T4 RATINGS AND CASE CODES - M39006/25 μF 6.8 10 22 27 33 39 47 56 68 82 100 120 150 180 220 270 330 390 470 560 680 820 1000 1200 1500 1800 2200 6 8 10 15 25 30 50 60 75 T1 T1 T1 T2 T1 T2 T3 T1 T1 T3 T2 T1 T4 T2 T2 T4 T1 T1 T1 T2 T2 T3 T4 T3 T4 T3 T4 T2 T2 T3 T4 T2 T2 T3 T3 T4 T3 T4 T3 T4 T3 T4 T4 Revison: 28-Aug-12 Document Number: 40022 3 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 M39006/22, M39006/25 www.vishay.com Vishay STANDARD RATINGS/EXTENDED RATINGS: CLR79, M39006/22-XXXX MAX. (2) PART NO. M39006/22- (1) MAX. CAPACITANCE MAX. MAX. DCL (μA) MAX. FAILURE RATE LEVEL RIPPLE CHANGE (%) AT IMP. AT DF CAP. (%/1000 h) CURRENT CAPACITANCE CASE AT AT TOL. AT + 85 °C (μF) CODE (± %) M P R + 85 °C + 25 °C - 55 °C 40 kHz + 25 °C - 55 °C + 85 °C + 125 °C () (%) 1.0 0.1 0.01 + 125 °C (mA) 30 30 30 68 68 68 140 140 140 270 270 270 330 330 330 560 560 560 1200 1200 T1 T1 T1 T1 T1 T1 T2 T2 T2 T2 T2 T2 T3 T3 T3 T3 T3 T3 T4 T4 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 0001 0002 0003 0004 0005 0006 0007 0008 0009 0010 0011 0012 0013 0014 0015 0016 0017 0018 0019 0020 25 25 25 56 56 56 120 120 120 220 220 220 290 290 290 430 430 430 850 850 T1 T1 T1 T1 T1 T1 T2 T2 T2 T2 T2 T2 T3 T3 T3 T3 T3 T3 T4 T4 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 0021 0022 0023 0024 0025 0026 0027 0028 0029 0030 0031 0032 0033 0034 0035 0036 0037 0038 0039 0040 20 20 20 47 47 47 100 100 100 180 T1 T1 T1 T1 T1 T1 T2 T2 T2 T2 20 10 5 20 10 5 20 10 5 20 0041 0042 0043 0044 0045 0046 0047 0048 0049 0050 6 VDC AT + 85 °C; 4 VDC AT + 125 °C 0441 1.0 2.0 9 0442 1.0 2.0 9 0443 1.0 2.0 9 0444 1.0 2.0 15 0445 1.0 2.0 15 0446 1.0 2.0 15 0447 1.0 3.0 21 0448 1.0 3.0 21 0449 1.0 3.0 21 0450 1.0 6.5 45 0451 1.0 6.5 45 0452 1.0 6.5 45 0453 2.0 7.9 36 0454 2.0 7.9 36 0455 2.0 7.9 36 0456 2.0 13.0 55 0457 2.0 13.0 55 0458 2.0 13.0 55 0459 3.0 14.0 90 0460 3.0 14.0 90 8 VDC AT + 85 °C; 5 VDC AT + 125 °C 0241 0461 1.0 2.0 7.5 0242 0462 1.0 2.0 7.5 0243 0463 1.0 2.0 7.5 0244 0464 1.0 2.0 14 0245 0465 1.0 2.0 14 0246 0466 1.0 2.0 14 0247 0467 1.0 2.0 20 0248 0468 1.0 2.0 20 0249 0469 1.0 2.0 20 0250 0470 1.0 7.0 37 0251 0471 1.0 7.0 37 0252 0472 1.0 7.0 37 0253 0473 2.0 6.0 34 0254 0474 2.0 6.0 34 0255 0475 2.0 6.0 34 0256 0476 2.0 14.0 46 0257 0477 2.0 14.0 46 0258 0478 2.0 14.0 46 0259 0479 4.0 16.0 60 0260 0480 4.0 16.0 60 10 VDC AT + 85 °C; 7 VDC AT + 125 °C 0261 0481 1.0 2.0 6 0262 0482 1.0 2.0 6 0263 0483 1.0 2.0 6 0264 0484 1.0 2.0 13 0265 0485 1.0 2.0 13 0266 0486 1.0 2.0 13 0267 0487 1.0 4.0 15 0268 0488 1.0 4.0 15 0269 0489 1.0 4.0 15 0270 0490 1.0 7.0 30 0221 0222 0223 0224 0225 0226 0227 0228 0229 0230 0231 0232 0233 0234 0235 0236 0237 0238 0239 0240 100 100 100 60 60 60 40 40 40 25 25 25 20 20 20 25 25 25 20 20 - 40 - 40 - 40 - 40 - 40 - 40 - 40 - 40 - 40 - 44 - 44 - 44 - 44 - 44 - 44 - 64 - 64 - 64 - 80 - 80 + 10.5 + 10.5 + 10.5 + 14 + 14 + 14 + 14 + 14 + 14 + 17.5 + 17.5 + 17.5 + 14 + 14 + 14 + 17.5 + 17.5 + 17.5 + 25 + 25 + 12 + 12 + 12 + 16 + 16 + 16 + 16 + 16 + 16 + 20 + 20 + 20 + 16 + 16 + 16 + 20 + 20 + 20 + 25 + 25 820 820 820 960 960 960 1200 1200 1200 1375 1375 1375 1800 1800 1800 1900 1900 1900 2265 2265 100 100 100 59 59 59 50 50 50 30 30 30 25 25 25 25 25 25 22 22 - 40 - 40 - 40 - 40 - 40 - 40 - 44 - 44 - 44 - 44 - 44 - 44 - 64 - 64 - 64 - 64 - 64 - 64 - 80 - 80 + 10.5 + 10.5 + 10.5 + 14 + 14 + 14 + 17.5 + 17.5 + 17.5 + 17.5 + 17.5 + 17.5 + 17.5 + 17.5 + 17.5 + 17.5 + 17.5 + 17.5 + 25 + 25 + 12 + 12 + 12 + 16 + 16 + 16 + 20 + 20 + 20 + 20 + 20 + 20 + 20 + 20 + 20 + 20 + 20 + 20 + 25 + 25 820 820 820 900 900 900 1220 1220 1220 1370 1370 1370 1770 1770 1770 1825 1825 1825 2330 2330 175 175 175 100 100 100 60 60 60 40 - 32 - 32 - 32 - 36 - 36 - 36 - 36 - 36 - 36 - 36 + 10.5 + 10.5 + 10.5 + 14 + 14 + 14 + 14 + 14 + 14 + 14 + 12 + 12 + 12 + 16 + 16 + 16 + 16 + 16 + 16 + 16 820 820 820 855 855 855 1200 1200 1200 1365 Notes Dash number will include the letter “H” to indicate the optional vibration and shock requirements (i.e., 51 g random vibration, 80 g sinusoidal vibration and 500 g shock). (2) For ripple current limits at various temperatures, voltages and frequencies, see Ripple Current table. (1) Revison: 28-Aug-12 Document Number: 40022 4 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 M39006/22, M39006/25 www.vishay.com Vishay STANDARD RATINGS/EXTENDED RATINGS: CLR79, M39006/22-XXXX MAX. (2) PART NO. M39006/22- (1) MAX. CAPACITANCE MAX. MAX. DCL (μA) MAX. FAILURE RATE LEVEL RIPPLE CHANGE (%) AT IMP. AT DF CAP. (%/1000 h) CURRENT CAPACITANCE CASE AT AT TOL. AT + 85 °C (μF) CODE (± %) M P R + 85 °C + 25 °C - 55 °C 40 kHz + 25 °C - 55 °C + 85 °C + 125 °C () (%) 1.0 0.1 0.01 + 125 °C (mA) 180 180 250 250 250 390 390 390 750 750 T2 T2 T3 T3 T3 T3 T3 T3 T4 T4 10 5 20 10 5 20 10 5 20 10 0051 0052 0053 0054 0055 0056 0057 0058 0059 0060 15 15 15 33 33 33 70 70 70 120 120 120 170 170 170 270 270 270 540 540 T1 T1 T1 T1 T1 T1 T2 T2 T2 T2 T2 T2 T3 T3 T3 T3 T3 T3 T4 T4 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 0061 0062 0063 0064 0065 0066 0067 0068 0069 0070 0071 0072 0073 0074 0075 0076 0077 0078 0079 0080 10 10 10 22 22 22 50 50 50 100 100 100 120 120 120 180 180 180 350 350 T1 T1 T1 T1 T1 T1 T2 T2 T2 T2 T2 T2 T3 T3 T3 T3 T3 T3 T4 T4 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 0081 0082 0083 0084 0085 0086 0087 0088 0089 0090 0091 0092 0093 0094 0095 0096 0097 0098 0099 0100 10 VDC AT + 85 °C; 7 VDC AT + 125 °C 0271 0491 1.0 7.0 30 0272 0492 1.0 7.0 30 0273 0493 2.0 10.0 30 0274 0494 2.0 10.0 30 0275 0495 2.0 10.0 30 0276 0496 2.0 16.0 44 0277 0497 2.0 16.0 44 0278 0498 2.0 16.0 44 0279 0499 4.0 16.0 50 0280 0500 4.0 16.0 50 15 VDC AT + 85 °C; 10 VDC AT + 125 °C 0281 0501 1.0 2.0 5 0282 0502 1.0 2.0 5 0283 0503 1.0 2.0 5 0284 0504 1.0 2.0 10 0285 0505 1.0 2.0 10 0286 0506 1.0 2.0 10 0287 0507 1.0 4.0 13 0288 0508 1.0 4.0 13 0289 0509 1.0 4.0 13 0290 0510 1.0 7.0 18 0291 0511 1.0 7.0 18 0292 0512 1.0 7.0 18 0293 0513 2.0 10.0 25 0294 0514 2.0 10.0 25 0295 0515 2.0 10.0 25 0296 0516 2.0 16.0 32 0297 0517 2.0 16.0 32 0298 0518 2.0 16.0 32 0299 0519 6.0 24.0 40 0300 0520 6.0 24.0 40 25 VDC AT + 85 °C; 15 VDC AT + 125 °C 0301 0521 1.0 2.0 4 0302 0522 1.0 2.0 4 0303 0523 1.0 2.0 4 0304 0524 1.0 2.0 6.6 0305 0525 1.0 2.0 6.6 0306 0526 1.0 2.0 6.6 0307 0527 1.0 2.0 11.0 0308 0528 1.0 2.0 11.0 0309 0529 1.0 2.0 11.0 0310 0530 1.0 10.0 15 0311 0531 1.0 10.0 15 0312 0532 1.0 10.0 15 0313 0533 2.0 6.0 21 0314 0534 2.0 6.0 21 0315 0535 2.0 6.0 21 0316 0536 2.0 18.0 26 0317 0537 2.0 18.0 26 0318 0538 2.0 18.0 26 0319 0539 7.0 28.0 35 0320 0540 7.0 28.0 35 40 40 30 30 30 25 25 25 23 23 - 36 - 36 - 40 - 40 - 40 - 64 - 64 - 64 - 80 - 80 + 14 + 14 + 14 + 14 + 14 + 17.5 + 17.5 + 17.5 + 25 + 25 + 16 + 16 + 16 + 16 + 16 + 20 + 20 + 20 + 25 + 25 1365 1365 1720 1720 1720 1800 1800 1800 2360 2360 155 155 155 90 90 90 75 75 75 50 50 50 35 35 35 30 30 30 23 23 - 24 - 24 - 24 - 28 - 28 - 28 - 28 - 28 - 28 - 28 - 28 - 28 - 32 - 32 - 32 - 56 - 56 - 56 - 80 - 80 + 10.5 + 10.5 + 10.5 + 14 + 14 + 14 + 14 + 14 + 14 + 17.5 + 17.5 + 17.5 + 14 + 14 + 14 + 17.5 + 17.5 + 17.5 + 25 + 25 + 12 + 12 + 12 + 16 + 16 + 16 + 16 + 16 + 16 + 20 + 20 + 20 + 16 + 16 + 16 + 20 + 20 + 20 + 25 + 25 780 780 780 820 820 820 1150 1150 1150 1450 1450 1450 1480 1480 1480 1740 1740 1740 2330 2330 220 220 220 140 140 140 70 70 70 50 50 50 38 38 38 32 32 32 24 24 - 16 - 16 - 16 - 20 - 20 - 20 - 28 - 28 - 28 - 28 - 28 - 28 - 32 - 32 - 32 - 48 - 48 - 48 - 70 - 70 +8 +8 +8 + 10.5 + 10.5 + 10.5 + 13 + 13 + 13 + 13 + 13 + 13 + 13 + 13 + 13 + 13 + 13 + 13 + 25 + 25 +9 +9 +9 + 12 + 12 + 12 + 15 + 15 + 15 + 15 + 15 + 15 + 15 + 15 + 15 + 15 + 15 + 15 + 25 + 25 715 715 715 825 825 825 1130 1130 1130 1435 1435 1435 1450 1450 1450 1525 1525 1525 1970 1970 Notes Dash number will include the letter “H” to indicate the optional vibration and shock requirements (i.e., 51 g random vibration, 80 g sinusoidal vibration and 500 g shock). (2) For ripple current limits at various temperatures, voltages and frequencies, see Ripple Current table. (1) Revison: 28-Aug-12 Document Number: 40022 5 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 M39006/22, M39006/25 www.vishay.com Vishay STANDARD RATINGS/EXTENDED RATINGS: CLR79, M39006/22-XXXX MAX. (2) PART NO. M39006/22- (1) MAX. CAPACITANCE MAX. MAX. DCL (μA) MAX. FAILURE RATE LEVEL RIPPLE CHANGE (%) AT IMP. AT DF CAP. (%/1000 h) CURRENT CAPACITANCE CASE AT AT TOL. AT + 85 °C (μF) CODE (± %) M P R + 85 °C + 25 °C - 55 °C 40 kHz + 25 °C - 55 °C + 85 °C + 125 °C () (%) 1.0 0.1 0.01 + 125 °C (mA) 8.0 8.0 8.0 15 15 15 40 40 40 68 68 68 100 100 100 150 150 150 300 300 T1 T1 T1 T1 T1 T1 T2 T2 T2 T2 T2 T2 T3 T3 T3 T3 T3 T3 T4 T4 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 0101 0102 0103 0104 0105 0106 0107 0108 0109 0110 0111 0112 0113 0114 0115 0116 0117 0118 0119 0120 5.0 5.0 5.0 10 10 10 25 25 25 47 47 47 60 60 60 82 82 82 160 160 T1 T1 T1 T1 T1 T1 T2 T2 T2 T2 T2 T2 T3 T3 T3 T3 T3 T3 T4 T4 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 0121 0122 0123 0124 0125 0126 0127 0128 0129 0130 0131 0132 0133 0134 0135 0136 0137 0138 0139 0140 4.0 4.0 4.0 8.2 8.2 8.2 20 20 20 39 T1 T1 T1 T1 T1 T1 T2 T2 T2 T2 20 10 5 20 10 5 20 10 5 20 0141 0142 0143 0144 0145 0146 0147 0148 0149 0150 30 VDC AT + 85 °C; 20 VDC AT + 125 °C 0321 0541 1.0 2.0 4 0322 0542 1.0 2.0 4 0323 0543 1.0 2.0 4 0324 0544 1.0 2.0 5 0325 0545 1.0 2.0 5 0326 0546 1.0 2.0 5 0327 0547 1.0 5.0 10 0328 0548 1.0 5.0 10 0329 0549 1.0 5.0 10 0330 0550 1.0 8.0 13 0331 0551 1.0 8.0 13 0332 0552 1.0 8.0 13 0333 0553 2.0 12.0 17 0334 0554 2.0 12.0 17 0335 0555 2.0 12.0 17 0336 0556 2.0 18.0 23 0337 0557 2.0 18.0 23 0338 0558 2.0 18.0 23 0339 0559 8.0 32.0 31 0340 0560 8.0 32.0 31 50 VDC AT + 85 °C; 30 VDC AT + 125 °C 0341 0561 1.0 2.0 3 0342 0562 1.0 2.0 3 0343 0563 1.0 2.0 3 0344 0564 1.0 2.0 4 0345 0565 1.0 2.0 4 0346 0566 1.0 2.0 4 0347 0567 1.0 5.0 8 0348 0568 1.0 5.0 8 0349 0569 1.0 5.0 8 0350 0570 1.0 9.0 11 0351 0571 1.0 9.0 11 0352 0572 1.0 9.0 11 0353 0573 2.0 12.0 12 0354 0574 2.0 12.0 12 0355 0575 2.0 12.0 12 0356 0576 2.0 16.0 15 0357 0577 2.0 16.0 15 0358 0578 2.0 16.0 15 0359 0579 8.0 32.0 17 0360 0580 8.0 32.0 17 60 VDC AT + 85 °C; 40 VDC AT + 125 °C 0361 0581 1.0 2.0 2.8 0362 0582 1.0 2.0 2.8 0363 0583 1.0 2.0 2.8 0364 0584 1.0 2.0 4 0365 0585 1.0 2.0 4 0366 0586 1.0 2.0 4 0367 0587 1.0 5.0 7 0368 0588 1.0 5.0 7 0369 0589 1.0 5.0 7 0370 0590 1.0 9.0 10 275 275 275 175 175 175 65 65 65 60 60 60 40 40 40 35 35 35 25 25 - 16 - 16 - 16 - 20 - 20 - 20 - 24 - 24 - 24 - 24 - 24 - 24 - 28 - 28 - 28 - 48 - 48 - 48 - 60 - 60 +8 +8 +8 + 10.5 + 10.5 + 10.5 + 10.5 + 10.5 + 10.5 + 13 + 13 + 13 + 10.5 + 10.5 + 10.5 + 13 + 13 + 13 + 25 + 25 + 12 + 12 + 12 + 12 + 12 + 12 + 12 + 12 + 12 + 15 + 15 + 15 + 12 + 12 + 12 + 15 + 15 + 15 + 25 + 25 640 640 640 780 780 780 1120 1120 1120 1285 1285 1285 1450 1450 1450 1525 1525 1525 1950 1950 400 400 400 250 250 250 95 95 95 70 70 70 45 45 45 45 45 45 27 27 - 16 - 16 - 16 - 24 - 24 - 24 - 20 - 20 - 20 - 28 - 28 - 28 - 16 - 16 - 16 - 32 - 32 - 32 - 50 - 50 +5 +5 +5 +8 +8 +8 + 10.5 + 10.5 + 10.5 + 13 + 13 + 13 + 10.5 + 10.5 + 10.5 + 13 + 13 + 13 + 25 + 25 +6 +6 +6 +9 +9 +9 + 12 + 12 + 12 + 15 + 15 + 15 + 12 + 12 + 12 + 15 + 15 + 15 + 25 + 25 580 580 580 715 715 715 1005 1005 1005 1155 1155 1155 1335 1335 1335 1400 1400 1400 1900 1900 550 550 550 275 275 275 105 105 105 90 - 16 - 16 - 16 - 24 - 24 - 24 - 16 - 16 - 16 - 28 +5 +5 +5 +8 +8 +8 + 10.5 + 10.5 + 10.5 + 10.5 +6 +6 +6 +9 +9 +9 + 12 + 12 + 12 + 12 525 525 525 625 625 625 930 930 930 1110 Notes Dash number will include the letter “H” to indicate the optional vibration and shock requirements (i.e., 51 g random vibration, 80 g sinusoidal vibration and 500 g shock). (2) For ripple current limits at various temperatures, voltages and frequencies, see Ripple Current table. (1) Revison: 28-Aug-12 Document Number: 40022 6 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 M39006/22, M39006/25 www.vishay.com Vishay STANDARD RATINGS/EXTENDED RATINGS: CLR79, M39006/22-XXXX MAX. (2) PART NO. M39006/22- (1) MAX. CAPACITANCE MAX. MAX. DCL (μA) MAX. FAILURE RATE LEVEL RIPPLE CHANGE (%) AT IMP. AT DF CAP. (%/1000 h) CURRENT CAPACITANCE CASE AT AT TOL. AT + 85 °C (μF) CODE (± %) M P R + 85 °C + 25 °C - 55 °C 40 kHz + 25 °C - 55 °C + 85 °C + 125 °C () (%) 1.0 0.1 0.01 + 125 °C (mA) 39 39 50 50 50 68 68 68 140 140 T2 T2 T3 T3 T3 T3 T3 T3 T4 T4 10 5 20 10 5 20 10 5 20 10 0151 0152 0153 0154 0155 0156 0157 0158 0159 0160 3.5 3.5 3.5 6.8 6.8 6.8 15 15 15 33 33 33 40 40 40 56 56 56 110 110 T1 T1 T1 T1 T1 T1 T2 T2 T2 T2 T2 T2 T3 T3 T3 T3 T3 T3 T4 T4 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 0161 0162 0163 0164 0165 0166 0167 0168 0169 0170 0171 0172 0173 0174 0175 0176 0177 0178 0179 0180 2.5 2.5 2.5 4.7 4.7 4.7 11 11 11 22 22 22 30 30 30 43 43 43 86 86 T1 T1 T1 T1 T1 T1 T2 T2 T2 T2 T2 T2 T3 T3 T3 T3 T3 T3 T4 T4 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 0181 0182 0183 0184 0185 0186 0187 0188 0189 0190 0191 0192 0193 0194 0195 0196 0197 0198 0199 0200 60 VDC AT + 85 °C; 40 VDC AT + 125 °C 0371 0591 1.0 9.0 10 0372 0592 1.0 9.0 10 0373 0593 2.0 12.0 10 0374 0594 2.0 12.0 10 0375 0595 2.0 12.0 10 0376 0596 2.0 16.0 13 0377 0597 2.0 16.0 13 0378 0598 2.0 16.0 13 0379 0599 8.0 32.0 16 0380 0600 8.0 32.0 16 75 VDC AT + 85 °C; 50 VDC AT + 125 °C 0381 0601 1.0 2.0 2.5 0382 0602 1.0 2.0 2.5 0383 0603 1.0 2.0 2.5 0384 0604 1.0 2.0 3.5 0385 0605 1.0 2.0 3.5 0386 0606 1.0 2.0 3.5 0387 0607 1.0 5.0 6 0388 0608 1.0 5.0 6 0389 0609 1.0 5.0 6 0390 0610 1.0 10.0 10 0391 0611 1.0 10.0 10 0392 0612 1.0 10.0 10 0393 0613 2.0 12.0 9 0394 0614 2.0 12.0 9 0395 0615 2.0 12.0 9 0396 0616 2.0 17.0 11 0397 0617 2.0 17.0 11 0398 0618 2.0 17.0 11 0399 0619 9.0 36.0 12 0400 0620 9.0 36.0 12 100 VDC AT + 85 °C; 65 VDC AT + 125 °C 0401 0621 1.0 2.0 2 0402 0622 1.0 2.0 2 0403 0623 1.0 2.0 2 0404 0624 1.0 2.0 3 0405 0625 1.0 2.0 3 0406 0626 1.0 2.0 3 0407 0627 1.0 4.0 5 0408 0628 1.0 4.0 5 0409 0629 1.0 4.0 5 0410 0630 1.0 9.0 7.5 0411 0631 1.0 9.0 7.5 0412 0632 1.0 9.0 7.5 0413 0633 2.0 12.0 7 0414 0634 2.0 12.0 7 0415 0635 2.0 12.0 7 0416 0636 2.0 17.0 8.5 0417 0637 2.0 17.0 8.5 0418 0638 2.0 17.0 8.5 0419 0639 9.0 36.0 10 0420 0640 9.0 36.0 10 90 90 50 50 50 50 50 50 28 28 - 28 - 28 - 16 - 16 - 16 - 32 - 32 - 32 - 40 - 40 + 10.5 + 10.5 + 10.5 + 10.5 + 10.5 + 10.5 + 10.5 + 10.5 + 20 + 20 + 12 + 12 + 12 + 12 + 12 + 12 + 12 + 12 + 20 + 20 1110 1110 1330 1330 1330 1365 1365 1365 1850 1850 650 650 650 300 300 300 150 150 150 90 90 90 60 60 60 60 60 60 29 29 - 16 - 16 - 16 - 20 - 20 - 20 - 16 - 16 - 16 - 24 - 24 - 24 - 16 - 16 - 16 - 28 - 28 - 28 - 35 - 35 +5 +5 +5 +8 +8 +8 +8 +8 +8 + 10.5 + 10.5 + 10.5 + 10.5 + 10.5 + 10.5 + 10.5 + 10.5 + 10.5 + 20 + 20 +6 +6 +6 +9 +9 +9 +9 +9 +9 + 15 + 15 + 15 + 12 + 12 + 12 + 15 + 15 + 15 + 20 + 20 525 525 525 610 610 610 890 890 890 1000 1000 1000 1250 1250 1250 1335 1335 1335 1850 1850 950 950 950 500 500 500 200 200 200 100 100 100 80 80 80 70 70 70 30 30 - 16 - 16 - 16 - 16 - 16 - 16 - 16 - 16 - 16 - 16 - 16 - 16 - 16 - 16 - 16 - 20 - 20 - 20 - 25 - 25 +7 +7 +7 +7 +7 +7 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 + 15 + 15 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 + 15 + 15 505 505 505 565 565 565 835 835 835 965 965 965 1240 1240 1240 1335 1335 1335 1800 1800 Notes Dash number will include the letter “H” to indicate the optional vibration and shock requirements (i.e., 51 g random vibration, 80 g sinusoidal vibration and 500 g shock). (2) For ripple current limits at various temperatures, voltages and frequencies, see Ripple Current table. (1) Revison: 28-Aug-12 Document Number: 40022 7 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 M39006/22, M39006/25 www.vishay.com Vishay STANDARD RATINGS/EXTENDED RATINGS: CLR79, M39006/22-XXXX MAX. (2) PART NO. M39006/22- (1) MAX. CAPACITANCE MAX. MAX. DCL (μA) MAX. FAILURE RATE LEVEL RIPPLE CHANGE (%) AT IMP. AT DF CAP. (%/1000 h) CURRENT CAPACITANCE CASE AT AT TOL. AT + 85 °C (μF) CODE (± %) M P R + 85 °C + 25 °C - 55 °C 40 kHz + 25 °C - 55 °C + 85 °C + 125 °C () (%) 1.0 0.1 0.01 + 125 °C (mA) 1.7 1.7 1.7 3.6 3.6 3.6 9.0 9.0 9.0 14 14 14 18 18 18 25 25 25 56 56 T1 T1 T1 T1 T1 T1 T2 T2 T2 T2 T2 T2 T3 T3 T3 T3 T3 T3 T4 T4 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 5 20 10 0201 0202 0203 0204 0205 0206 0207 0208 0209 0210 0211 0212 0213 0214 0215 0216 0217 0218 0219 0220 125 VDC AT + 85 °C; 85 VDC AT + 125 °C 0421 0641 1.0 2.0 2 1250 0422 0642 1.0 2.0 2 1250 0423 0643 1.0 2.0 2 1250 0424 0644 1.0 2.0 2.7 600 0425 0645 1.0 2.0 2.7 600 0426 0646 1.0 2.0 2.7 600 0427 0647 1.0 5.0 5 240 0428 0648 1.0 5.0 5 240 0429 0649 1.0 5.0 5 240 0430 0650 1.0 7.0 6 167 0431 0651 1.0 7.0 6 167 0432 0652 1.0 7.0 6 167 0433 0653 2.0 9.0 5 129 0434 0654 2.0 9.0 5 129 0435 0655 2.0 9.0 5 129 0436 0656 2.0 13.0 6 93 0437 0657 2.0 13.0 6 93 0438 0658 2.0 13.0 6 93 0439 0659 10.0 40.0 6.5 32 0440 0660 10.0 40.0 6.5 32 - 16 - 16 - 16 - 16 - 16 - 16 - 16 - 16 - 16 - 16 - 16 - 16 - 16 - 16 - 16 - 16 - 16 - 16 - 25 - 25 +7 +7 +7 +7 +7 +7 +7 +7 +7 +7 +7 +7 +7 +7 +7 +7 +7 +7 + 15 + 15 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 + 15 + 15 415 415 415 520 520 520 755 755 755 860 860 860 1130 1130 1130 1200 1200 1200 1800 1800 Notes Dash number will include the letter “H” to indicate the optional vibration and shock requirements (i.e., 51 g random vibration, 80 g sinusoidal vibration and 500 g shock). (2) For ripple current limits at various temperatures, voltages and frequencies, see Ripple Current table. (1) STANDARD RATINGS/EXTENDED RATINGS: CLR81, M39006/25-XXXX MAX. (1) PART NO. M39006/25- (1) MAX. CAPACITANCE MAX. MAX. DCL (μA) MAX. FAILURE RATE LEVEL RIPPLE CHANGE (%) AT IMP. AT DF CAP. (%/1000 h) CURRENT CAPACITANCE CASE AT AT TOL. AT + 85 °C (μF) CODE (± %) + 85 °C + 25 °C - 55 °C M P R 40 kHz + 25 °C 55 °C + 85 °C + 125 °C () (%) 1.0 0.1 0.01 + 125 °C (mA) 220 220 820 820 1500 1500 2200 2200 T1 T1 T2 T2 T3 T3 T4 T4 20 10 20 10 20 10 20 10 0001 0002 0003 0004 0005 0006 0007 0008 0089 0090 0091 0092 0093 0094 0095 0096 180 180 680 680 1500 1500 1800 1800 T1 T1 T2 T2 T3 T3 T4 T4 20 10 20 10 20 10 20 10 0009 0010 0011 0012 0013 0014 0015 0016 0097 0098 0099 0100 0101 0102 0103 0104 6 VDC AT + 85 °C; 4 VDC AT + 125 °C 0177 2.0 9.0 50 0178 2.0 9.0 50 0179 3.0 14.0 155 0180 3.0 14.0 155 0181 5.0 20.0 172 0182 5.0 20.0 172 0183 6.0 24.0 170 0184 6.0 24.0 170 8 VDC AT + 85 °C; 5 VDC AT + 125 °C 0185 2.0 9.0 41 0186 2.0 9.0 41 0187 3.0 14.0 130 0188 3.0 14.0 130 0189 5.0 20.0 170 0190 5.0 20.0 170 0191 7.0 25.0 138 0192 7.0 25.0 138 36 36 18 18 18 18 13 13 - 64 - 64 - 88 - 88 - 90 - 90 - 90 - 90 + 13 + 13 + 16 + 16 + 20 + 20 + 25 + 25 + 16 + 16 + 20 + 20 + 25 + 25 + 30 + 30 1000 1000 1500 1500 1900 1900 2300 2300 45 45 22 22 18 18 14 14 - 60 - 60 - 83 - 83 - 90 - 90 - 90 - 90 + 13 + 13 + 16 + 16 + 20 + 20 + 25 + 25 + 16 + 16 + 20 + 20 + 25 + 25 + 30 + 30 1000 1000 1500 1500 1900 1900 2300 2300 Notes (1) Dash number will include the letter “H” to indicate the optional vibration and shock requirements (i.e., 51 g random vibration, 80 g sinusoidal vibration and 500 g shock). (2) For ripple current limits at various temperatures, voltages and frequencies, see Ripple Current table. Revison: 28-Aug-12 Document Number: 40022 8 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 M39006/22, M39006/25 www.vishay.com Vishay STANDARD RATINGS/EXTENDED RATINGS: CLR81, M39006/25-XXXX MAX. (1) PART NO. M39006/25- (1) MAX. CAPACITANCE MAX. MAX. DCL (μA) MAX. FAILURE RATE LEVEL RIPPLE CHANGE (%) AT IMP. AT DF CAP. (%/1000 h) CURRENT CAPACITANCE CASE AT AT TOL. AT + 85 °C (μF) CODE (± %) M P R + 85 °C + 25 °C - 55 °C 40 kHz + 25 °C - 55 °C + 85 °C + 125 °C () (%) 1.0 0.1 0.01 + 125 °C (mA) 150 150 560 560 1200 1200 1500 1500 T1 T1 T2 T2 T3 T3 T4 T4 20 10 20 10 20 10 20 10 0017 0018 0019 0020 0021 0022 0023 0024 100 100 390 390 820 820 1000 1000 T1 T1 T2 T2 T3 T3 T4 T4 20 10 20 10 20 10 20 10 0025 0026 0027 0028 0029 0030 0031 0032 68 68 270 270 560 560 680 680 T1 T1 T2 T2 T3 T3 T4 T4 20 10 20 10 20 10 20 10 0033 0034 0035 0036 0037 0038 0039 0040 56 56 220 220 470 470 560 560 T1 T1 T2 T2 T3 T3 T4 T4 20 10 20 10 20 10 20 10 0041 0042 0043 0044 0045 0046 0047 0048 33 33 120 120 270 270 330 330 T1 T1 T2 T2 T3 T3 T4 T4 20 10 20 10 20 10 20 10 0049 0050 0051 0052 0053 0054 0055 0056 27 27 100 100 220 220 270 270 T1 T1 T2 T2 T3 T3 T4 T4 20 10 20 10 20 10 20 10 0057 0058 0059 0060 0061 0062 0063 0064 10 VDC AT + 85 °C; 7 VDC AT + 125 °C 0193 2.0 9.0 34 0194 2.0 9.0 34 0195 3.0 16.0 106 0196 3.0 16.0 106 0197 5.0 20.0 137 0198 5.0 20.0 137 0199 7.0 25.0 114 0200 7.0 25.0 114 15 VDC AT + 85 °C; 10 VDC AT + 125 °C 0113 0201 2.0 9.0 30 0114 0202 2.0 9.0 30 0115 0203 3.0 16.0 74 0116 0204 3.0 16.0 74 0117 0205 6.0 24.0 111 0118 0206 6.0 24.0 111 0119 0207 8.0 32.0 92 0120 0208 8.0 32.0 92 25 VDC AT + 85 °C; 15 VDC AT + 125 °C 0121 0209 2.0 9.0 22 0122 0210 2.0 9.0 22 0123 0211 3.0 16.0 55 0124 0212 3.0 16.0 55 0125 0213 7.0 28.0 76 0126 0214 7.0 28.0 76 0127 0215 8.0 32.0 63 0128 0216 8.0 32.0 63 30 VDC AT + 85 °C; 20 VDC AT + 125 °C 0129 0217 2.0 9.0 22 0130 0218 2.0 9.0 22 0131 0219 3.0 16.0 42 0132 0220 3.0 16.0 42 0133 0221 8.0 32.0 64 0134 0222 8.0 32.0 64 0135 0223 9.0 36.0 55 0136 0224 9.0 36.0 55 50 VDC AT + 85 °C; 30 VDC AT + 125 °C 0137 0225 2.0 9.0 12.3 0138 0226 2.0 9.0 12.3 0139 0227 4.0 24.0 22.5 0140 0228 4.0 24.0 22.5 0141 0229 8.0 32.0 37 0142 0230 8.0 32.0 37 0143 0231 9.0 36.0 38 0144 0232 9.0 36.0 38 60 VDC AT + 85 °C;. 40 VDC AT + 125 °C 0145 0233 3.0 12.0 10.2 0146 0234 3.0 12.0 10.2 0147 0235 4.0 20.0 19 0148 0236 4.0 20.0 19 0149 0237 8.0 32.0 30 0150 0238 8.0 32.0 30 0151 0239 9.0 36.0 27 0152 0240 9.0 36.0 27 0105 0106 0107 0108 0109 0110 0111 0112 54 54 27 27 18 18 15 15 - 55 - 55 - 77 - 77 - 88 - 88 - 88 - 88 + 13 + 13 + 16 + 16 + 20 + 20 + 25 + 25 + 16 + 16 + 20 + 20 + 25 + 25 + 30 + 30 900 900 1450 1450 1850 1850 2300 2300 72 72 31 31 22 22 17 17 - 44 - 44 - 66 - 66 - 77 - 77 - 77 - 77 + 13 + 13 + 16 + 16 + 20 + 20 + 25 + 25 + 16 + 16 + 20 + 20 + 25 + 25 + 30 + 30 900 900 1450 1450 1800 1800 2300 2300 90 90 33 33 24 24 19 19 - 40 - 40 - 62 - 62 - 72 - 72 - 72 - 72 + 12 + 12 + 13 + 13 + 20 + 20 + 25 + 25 + 15 + 15 + 16 + 16 + 25 + 25 + 30 + 30 850 850 1400 1400 1750 1750 2100 2100 100 100 36 36 25 25 20 20 - 38 - 38 - 60 - 60 - 65 - 65 - 65 - 65 + 12 + 12 + 13 + 13 + 20 + 20 + 25 + 25 + 15 + 15 + 16 + 16 + 25 + 25 + 30 + 30 800 800 1200 1200 1500 1500 2000 2000 135 135 49 49 29 29 22 22 - 29 - 29 - 42 - 42 - 46 - 46 - 46 - 46 + 10 + 10 + 12 + 12 + 20 + 20 + 25 + 25 + 12 + 12 + 15 + 15 + 25 + 25 + 30 + 30 700 700 1200 1200 1450 1450 1900 1900 144 144 54 54 29 29 23 23 - 24 - 24 - 36 - 36 - 40 - 40 - 45 - 45 + 10 + 10 + 12 + 12 + 16 + 16 + 20 + 20 + 12 + 12 + 15 + 15 + 20 + 20 + 25 + 25 700 700 1100 1100 1400 1400 1850 1850 Notes (1) Dash number will include the letter “H” to indicate the optional vibration and shock requirements (i.e., 51 g random vibration, 80 g sinusoidal vibration and 500 g shock). (2) For ripple current limits at various temperatures, voltages and frequencies, see Ripple Current table. Revison: 28-Aug-12 Document Number: 40022 9 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 M39006/22, M39006/25 www.vishay.com Vishay STANDARD RATINGS/EXTENDED RATINGS: CLR81, M39006/25-XXXX MAX. (1) PART NO. M39006/25- (1) MAX. CAPACITANCE MAX. MAX. DCL (μA) MAX. FAILURE RATE LEVEL RIPPLE CHANGE (%) AT IMP. AT DF CAP. (%/1000 h) CURRENT CAPACITANCE CASE AT AT TOL. AT + 85 °C (μF) CODE (± %) M P R + 85 °C + 25 °C - 55 °C 40 kHz + 25 °C - 55 °C + 85 °C + 125 °C () (%) 1.0 0.1 0.01 + 125 °C (mA) 22 22 82 82 180 180 220 220 T1 T1 T2 T2 T3 T3 T4 T4 20 10 20 10 20 10 20 10 0065 0066 0067 0068 0069 0070 0071 0072 10 10 39 39 68 68 120 120 T1 T1 T2 T2 T3 T3 T4 T4 20 10 20 10 20 10 20 10 0073 0074 0075 0076 0077 0078 0079 0080 6.8 6.8 27 27 47 47 82 82 T1 T1 T2 T2 T3 T3 T4 T4 20 10 20 10 20 10 20 10 0081 0082 0083 0084 0085 0086 0087 0088 75 VDC AT + 85 °C; 50 VDC AT + 125 °C 0153 0241 3.0 12.0 8.5 0154 0242 3.0 12.0 8.5 0155 0243 4.0 24.0 15.2 0156 0244 4.0 24.0 15.2 0157 0245 9.0 36.0 24.4 0158 0246 9.0 36.0 24.4 0159 0247 10.0 40.0 37.0 0160 0248 10.0 40.0 37.0 100 VDC AT + 85 °C; 65 VDC AT + 125 °C 0161 0249 3.0 12.0 4.5 0162 0250 3.0 12.0 4.5 0163 0251 5.0 24.0 10.4 0164 0252 5.0 24.0 10.4 0165 0253 10.0 40.0 11.3 0166 0254 10.0 40.0 11.3 0167 0255 12.0 48.0 25 0168 0256 12.0 48.0 25 125 VDC AT + 85 °C; 85 VDC AT + 125 °C 0169 0257 3.0 12.0 6.0 0170 0258 3.0 12.0 6.0 0171 0259 5.0 24.0 7.2 0172 0260 5.0 24.0 7.2 0173 0261 10.0 40.0 7.9 0174 0262 10.0 40.0 7.9 0175 0263 12.0 48.0 17.4 0176 0264 12.0 48.0 17.4 157 157 63 63 30 30 24 24 - 19 - 19 - 30 - 30 - 35 - 35 - 40 - 40 + 10 + 10 + 12 + 12 + 16 + 16 + 20 + 20 + 12 + 12 + 15 + 15 + 20 + 20 + 25 + 25 600 600 1000 1000 1300 1300 1800 1800 200 200 80 80 40 40 30 30 - 17 - 17 - 20 - 20 - 30 - 30 - 35 - 35 + 10 + 10 + 12 + 12 + 14 + 14 + 15 + 15 + 12 + 12 + 15 + 15 + 16 + 16 + 17 + 17 800 800 1300 1300 1600 1600 2000 2000 300 300 90 90 50 50 32 32 - 14 - 14 - 18 - 18 - 26 - 26 - 30 - 30 + 10 + 10 + 12 + 12 + 14 + 14 + 15 + 15 + 12 + 12 + 15 + 15 + 16 + 16 + 17 + 17 700 700 1200 1200 1500 1500 1900 1900 Notes (1) Dash number will include the letter “H” to indicate the optional vibration and shock requirements (i.e., 51 g random vibration, 80 g sinusoidal vibration and 500 g shock). (2) For ripple current limits at various temperatures, voltages and frequencies, see Ripple Current table. CLR79, CLR81 RIPPLE CURRENT MULTIPLIERS VS. FREQUENCY, TEMPERATURE AND APPLIED PEAK VOLTAGE FREQUENCY OF APPLIED RIPPLE CURRENT AMBIENT STILL AIR % OF APPLIED VOLTAGE 120 Hz 800 Hz 1 kHz 10 kHz 40 kHz 100 kHz TEMP °C TEMP °C TEMP °C TEMP °C TEMP °C TEMP °C 55 85 105 125 55 85 105 125 55 85 105 125 55 85 105 125 55 85 105 125 55 85 105 125 100 % 0.60 0.39 - - 0.71 0.43 - - 0.72 0.46 - - 0.88 0.55 - - 1.0 0.63 - - 1.1 0.69 - - 90 % 0.60 0.46 - - 0.71 0.55 - - 0.72 0.55 - - 0.88 0.67 - - 1.0 0.77 - - 1.1 0.85 - - 80 % 0.60 0.52 0.35 - 0.71 0.62 0.42 - 0.72 0.62 0.42 - 0.88 0.76 0.52 - 1.0 0.87 0.59 - 1.1 0.96 0.65 - 70 % 0.60 0.58 0.44 - 0.71 0.69 0.52 - 0.72 0.70 0.52 - 0.88 0.85 0.64 - 1.0 0.97 0.73 - 1.1 1.07 0.80 - 66 2/3 % 0.60 0.60 0.46 0.27 0.71 0.71 0.55 0.32 0.72 0.72 0.55 0.32 0.88 0.88 0.68 0.40 1.0 1.0 0.77 0.45 1.1 1.1 0.85 0.50 Notes 1. At + 125 °C the rated voltage of the capacitors decreases to 66 2/3 % of the + 85 °C rated voltage. 2. The peak of the applied AC ripple voltage plus the applied DC voltage must not exceed the DC voltage rating of the capacitor eitherforward or reverse. 3. The ripple current listed represents a rating calculated using a maximum internal temperature rise (T) of + 50 °C at 40 kHz at + 85 °C ambient with a maximum peak rated voltage of 66 2/3 % of the + 85 °C peak voltage rating. 4. The maximum allowable internal temperature rise (T) decreases linearly to a calculated + 10 °C rise at + 125 °C ambient. 5. The internal temperature rise is directly proportional to the equivalent series resistance of the capacitor and equivalent series resistance increases with decreasing frequency. Revison: 28-Aug-12 Document Number: 40022 10 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Material Category Policy Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (EEE) - recast, unless otherwise specified as non-compliant. Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU. Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21 conform to JEDEC JS709A standards. Revision: 02-Oct-12 1 Document Number: 91000