HONEYWELL HMC5983

3-Axis Digital Compass IC
HMC5983
Advanced Information
The Honeywell HMC5983 is a temperature compensated three-axis integrated circuit magnetometer. This surface-mount,
multi-chip module is designed for low-field magnetic sensing for applications such as
automotive and personal navigation, vehicle detection, and pointing.
The
HMC5983
includes
our
state-of-the-art,
high-resolution
HMC118X
series
magnetoresistive sensors plus an ASIC containing amplification, automatic degaussing
strap drivers, offset cancellation, and a 12-bit ADC that enables 1° to 2° compass heading
accuracy.
The I²C or SPI serial bus allows for easy interface. The HMC5983 is a
3.0x3.0x0.9mm surface mount 16-pin leadless chip carrier (LCC).
The HMC5983 utilizes Honeywell’s Anisotropic Magnetoresistive (AMR) technology that provides advantages over other
magnetic sensor technologies. Honeywell’s anisotropic, directional sensors excel in linearity, low hysteresis, null output
and scale factor stability over temperature, and with very low cross-axis sensitivity.
These sensors’ solid-state
construction is designed to measure both the direction and the magnitude of magnetic fields, from milli-gauss to 8 gauss.
Honeywell’s Magnetic Sensors are among the most sensitive and reliable low-field sensors in the industry.
FEATURES
Magnetoresistive Sensors and
 3-Axis
ASIC in a 3.0x3.0x0.9mm LCC Surface
Mount Package
BENEFIT
size for Highly Integrated Products. Just add a micro Small
controller interface, plus two external SMT Capacitors
designed for high volume, cost sensitive OEM Designs.
Easy to assemble & compatible with High Speed SMT Assembly.

Temperature Compensated Data Output
and Temperature Output
maintains sensor’s sensitivity under wide operating
 Automatically
temperature range


Automatic Offset Compensation
 Maximizes sensor’s full dynamic range and resolution
 Enables 1° to 2° degree compass heading accuracy

I²C (Standard, Fast, High-Speed modes)
or SPI Digital Interface
interfaces for fast data communications.
 High-speed
MHz and SPI up to 8.0 MHz


Fast 220 Hz Maximum Output Rate
 Enables Pedestrian Navigation and LBS Applications
 Enables low-cost functionality test after assembly in production

Low Voltage Operations (2.16 to 3.6V)
and Low Power Consumption (100 μA)
 Compatible for battery powered applications

Built-In Strap Drive Circuits
and offset strap drivers for degaussing, self test, and offset
 Set/reset
compensation. Eliminates sensor calibration necessary for other
12-Bit ADC Coupled with Low Noise
AMR Sensors Achieves 2 milli-gauss
Field Resolution
Built-in Self Test
I²C up to 3.4
magnetic sensor technologies.

Lead Free Package Construction
 RoHS Compliance

Wide Magnetic Field Range (+/-8 Oe)
can be used in strong magnetic field environments with a 1°
 Sensors
to 2° degree compass heading accuracy

Software and Algorithm Support
Available
Heading, Hard Iron, Soft Iron, and Auto Calibration
 Compassing
libraries available
HMC5983
SPECIFICATIONS (* Tested and specified at 25°C except stated otherwise.)
Characteristics
Conditions*
Min
Typ
Max
Units
VDD Referenced to AGND
VDDIO Referenced to DGND
2.16
1.71
2.5
1.8
3.6
VDD+0.1
Volts
Volts
Idle Mode
Measurement Mode (7.5 Hz ODR;
No measurement average, MA1:MA0 = 00)
Specified at: VDD = 2.5V, VDDIO = 1.8V
-
2
100
-
μA
μA
Full scale (FS)
-8
+8
gauss
3-bit gain control
±1
±8
gauss
Sensitivity (Gain)
VDD=3.0V, GN=0 to 7, 12-bit ADC
230
1370
LSb/gauss
Digital Resolution
VDD=3.0V, GN=0 to 7, 1-LSb, 12-bit ADC
0.73
4.35
milli-gauss
Noise Floor
(Field Resolution)
VDD=3.0V, GN=0, No measurement
average, Standard Deviation 100 samples
(See typical performance graphs below)
Power Supply
Supply Voltage
Average Current Draw
Performance
Field Range
Mag Dynamic Range
milli-gauss
Linearity
±2.0 gauss input range
Hysteresis
±2.0 gauss input range
±25
ppm
Test Conditions: Cross field = 0.5 gauss,
Happlied = ±3 gauss
±0.2%
%FS/gauss
Cross-Axis Sensitivity
Output Rate (ODR)
Continuous Measurment Mode
Single Measurement Mode
0.1
0.75
220
160
±% FS
Hz
Measurement Period
From receiving command to data ready
6
ms
Turn-on Time
Ready for I²C commands
Analog Circuit Ready for Measurements
200
50
μs
ms
All gain/dynamic range settings
±5
%
8-bit read address
8-bit write address
0x3D
0x3C
hex
Gain Tolerance
I²C Address
Clock Rate
I²C Hysteresis
Self Test
Controlled by I²C /SPI Master
I²C
SPI
3400
8000
kHz
Hysteresis of Schmitt trigger inputs on SCL
and SDA - Fall (VDDIO=1.8V)
Rise (VDDIO=1.8V)
0.2*VDDIO
0.8*VDDIO
Volts
X & Y Axes
Z Axis
±1.16
±1.08
gauss
X & Y & Z Axes (GN=5) Positive Bias
X & Y & Z Axes (GN=5) Negative Bias
2
2
Temperature Sensor
Accuracy
3σ at T > 0°C
3σ at T = -25°C
3σ at T = -40°C
Sensitivity Tempco
TA = -40 to 85°C, Compensated Output
Temperature Sensor On
243
-575
-0.03
(3σ =0.12)
575
-243
LSb
7
11
14
°C
%/°C
www.honeywell.com
HMC5983
Characteristics
General
Conditions*
ESD Voltage
Min
Typ
Human Body Model (all pins)
Charged Device Model (all pins)
Operating Temperature
Max
Units
2000
750
Volts
Ambient
-30
85
°C
Storage Temperature
Ambient, unbiased
-40
125
°C
Reflow Classification
MSL 3, 260 C Peak Temperature
Package Size
Length and Width
Package Height
2.85
3.00
3.15
mm
0.8
0.9
1.0
mm
Package Weight
18
mg
Absolute Maximum Ratings (* Tested at 25°C except stated otherwise.)
Characteristics
Min
Max
Units
Supply Voltage VDD
-0.3
4.8
Volts
Supply Voltage VDDIO
-0.3
4.8
Volts
Reflow Classification
MSL 3, 260 C Peak Temperature
PIN CONFIGURATIONS
Table 1: Pin Configurations
Pin
Name
1
2
3
4
SCL/SPI_SCK
VDD
NC
SPI_CS
5
SPI_SDO
6
I²C /~SPI
7
8
NC
SETP
9
SoC
10
11
12
13
14
C1
GND
SETC
VDDIO
NC
15
DRDY
16
SDA/SPI_SDI
www.honeywell.com
Description
Serial Clock – I²C Master/Slave Clock or SPI Serial Clock
Power Supply (2.16V to 3.6V)
Not to be Connected
Chip Select line for SPI (active low). Tie to VDDIO for I²C Interface
SPI Serial Data Out
I²C / SPI selection pin. Connect to VDD for I²C (Also connect SPI_CS to VDDIO).
Connect to GND for SPI.
Not to be Connected
Set/Reset Strap Positive – S/R Capacitor (C2) Connection
Start of Conversion (leading edge active) Connect to Ground when this
function/pad is not used in application.
Reservoir Capacitor (C1) Connection
Supply Ground
S/R Capacitor (C2) Connection – Driver Side
IO Power Supply (1.71V to VDD)
Not to be Connected. No internal connection.
Data Ready, Interrupt Pin. Internally pulled high. Optional connection. Low for
>200 µsec when data are placed in the data output registers.
Serial Data – I²C Master/Slave Data or SPI Serial Data In or SPI Serial Data I/O
(SDI/O) for 3-wire interface
3
HMC5983
TOP VIEW (Looking Through)
Arrow indicates direction of magnetic field that generates a positive output reading in Normal Measurement configuration.
PACKAGE OUTLINES
PACKAGE DRAWING HMC5983 (16-PIN LPCC, dimensions in millimeters)
4
www.honeywell.com
HMC5983
MOUNTING CONSIDERATIONS
The following is the recommend printed circuit board (PCB) footprint for the HMC5983.
LAYOUT CONSIDERATIONS
Besides keeping all components that may contain ferrous materials (nickel, etc.) away from the sensor on both sides of
the PCB, it is also recommended that there is no conducting copper under/near the sensor in any of the PCB layers. See
recommended layout below.
I²C Layout Examples: Notice that the one trace under the sensor in the dual supply mode is not expected to carry active
current since it is for pin 4 pull-up to VDDIO. Power and ground planes are removed under the sensor to minimize
possible source of magnetic noise. For best results, use non-ferrous materials for all exposed copper coding.
www.honeywell.com
5
HMC5983
*Layout examples are for I²C (dual supply and single supply) modes only.
PCB Pad Definition and Traces
The HMC5983 is a fine pitch LCC package. Refer to previous figure for recommended PCB footprint for proper package
centering. Size the traces between the HMC5983 and the external capacitors (C1 and C2) to handle the 1 ampere peak
current pulses with low voltage drop on the traces.
Stencil Design and Solder Paste
A 4 mil stencil and 100% paste coverage is recommended for the electrical contact pads.
Reflow Assembly
This device is classified as MSL 3 with 260 C peak reflow temperature. As specified by JEDEC, parts with an MSL 3
rating require baking prior to soldering if the part is not kept in a continuously dry (< 10% RH) environment before
assembly. Refer to Table 4-1 “Reference Conditions for Drying Mounted or Unmounted SMD Packages” in the
IPC/JEDEC standard J-STD-033 “Handling, Packing, Shipping and Use of Moisture/Reflow Sensitive Surface Mount
Devices” for additional information.No special reflow profile is required for HMC5983, which is compatible with lead
eutectic and lead-free solder paste reflow profiles. Honeywell recommends adherence to solder paste manufacturer’s
guidelines. Hand soldering is not recommended. Built-in self test can be used to verify device functionalities after
assembly.
External Capacitors
The two external capacitors should be ceramic type construction with low ESR characteristics. The exact ESR values are
not critical but values less than 200 milli-ohms are recommended. Reservoir capacitor C1 is nominally 4.7 µF in
capacitance, with the set/reset capacitor C2 nominally 0.22 µF in capacitance. Low ESR characteristics may not be in
many small SMT ceramic capacitors (0402), so be prepared to up-size the capacitors to gain Low ESR characteristics.
6
www.honeywell.com
HMC5983
INTERNAL SCHEMATIC DIAGRAM
HMC5983
www.honeywell.com
7
HMC5983
DUAL SUPPLY REFERENCE DESIGN (I²C )
SINGLE SUPPLY REFERENCE DESIGN (I²C )
8
www.honeywell.com
HMC5983
DUAL SUPPLY REFERENCE DESIGN (SPI)
SINGLE SUPPLY REFERENCE DESIGN (SPI)
www.honeywell.com
9
HMC5983
PERFORMANCE
The following graph(s) highlight HMC5983’s performance.
Typical Noise Floor (Field Resolution)
HMC5983 Resolution
sg
in
d
a
e
R
0
0
1
v
e
D
td
S
n
o
it
lu
o
s
e
R
3
2.5
2
)a 1.5
G
(m 1
Expon.
1 Avg (1)
Expon.
2 Avg (2)
Expon.
4 Avg (4)
Expon.
8 Avg (8)
0.5
0
0
1
2
3
4
5
6
7
Gain
BASIC DEVICE OPERATION
Anisotropic Magneto-Resistive Sensors
The Honeywell HMC5983 magnetoresistive sensor circuit is a trio of sensors and application specific support circuits to
measure magnetic fields. With power supply applied, the sensor converts any incident magnetic field in the sensitive axis
directions to a differential voltage output. The magnetoresistive sensors are made of a nickel-iron (Permalloy) thin-film and
patterned as a resistive strip element. In the presence of a magnetic field, a change in the bridge resistive elements
causes a corresponding change in voltage across the bridge outputs.
These resistive elements are aligned together to have a common sensitive axis (indicated by arrows in the pinout
diagram) that will provide positive voltage change with magnetic fields increasing in the sensitive direction. Because the
output is only proportional to the magnetic field component along its axis, additional sensor bridges are placed at
orthogonal directions to permit accurate measurement of magnetic field in any orientation.
Self Test
To check the HMC5983 for proper operation, a self test feature is incorporated in which the sensor is internally excited
with a nominal magnetic field (in either positive or negative bias configuration). This field is then measured and reported.
This function is enabled and the polarity is set by bits MS[n] in the configuration register A. An internal current source
generates a DC current (about 10 mA) from the VDD supply. This DC current is applied to the offset straps of the
magneto-resistive sensor, which creates an artificial magnetic field on the sensor. The difference of this measurement
and the measurement of the ambient field will be put in the data output register for each of the three axes. By using this
built-in function, the manufacturer can quickly verify the sensor’s full functionality after the assembly without additional test
setup. The self test results can also be used to estimate/compensate the sensor’s sensitivity drift due to temperature.
For each “self test measurement”, the ASIC:
1. Sends a “Set” pulse
2. Takes one measurement (M1)
3. Sends the (~10 mA) offset current to generate the (~1.1 Gauss) offset field and takes another
measurement (M2)
4. Puts the difference of the two measurements in sensor’s data output register:
Output = [M2 – M1]
(i.e. output = offset field only)
See SELF TEST OPERATION section later in this datasheet for additional details.
10
www.honeywell.com
HMC5983
Power Management
This device has two different domains of power supply. The first one is VDD that is the power supply for internal
operations and the second one is VDDIO that is dedicated to IO interface. It is possible to work with VDDIO equal to VDD;
Single Supply mode, or with VDDIO lower than VDD allowing HMC5983 to be compatible with other devices on board.
Communication Bus Interface
This device will be connected to a serial interface bus as a slave device under the control of a master device, such as the
processor. Control of this device is carried out via I²C or SPI interfaces. Use pin 6 (I²C /~SPI) to select between I²C and
SPI interface modes.
I²C Interface
This device is compliant with I²C -Bus Specification, document number: 9398 393 40011. As an I²C compatible device,
this device has a 7-bit serial address and supports I²C protocols. This device supports standard, fast, and high speed
modes, 100kHz, 400kHz, and 3400kHz, respectively. External pull-up resistors are required to support all these modes.
Activities required by the master (register read and write) have priority over internal activities, such as the measurement.
The purpose of this priority is to not keep the master waiting and the I²C bus engaged for longer than necessary.
SPI Interface
This device is compliant with both 4-wire and 3-wire SPI interface standards. Selection 3-wire mode is by setting SIM (SPI
serial interface mode selection) bit (MR2) in mode register to 1. See SPI Communication Protocol section later in this
datasheet for additional details.
Internal Clock
The device has an internal clock for internal digital logic functions and timing management. This clock is not available to
external usage.
H-Bridge for Set/Reset Strap Drive
The ASIC contains large switching FETs capable of delivering a large but brief pulse to the Set/Reset strap of the sensor.
This strap is largely a resistive load. There is no need for an external Set/Reset circuit. The controlling of the Set/Reset
function is done automatically by the ASIC for each measurement. One half of the difference from the measurements
taken after a set pulse and after a reset pulse will be put in the data output register for each of the three axes. By doing
so, the sensor’s internal offset and its temperature dependence is removed/cancelled for all measurements. The set/reset
pulses also effectively remove the past magnetic history (magnetism) in the sensor, if any.
For each “measurement”, the ASIC:
1. Sends a “Set” pulse
2. Takes one measurement (Mset)
3. Sends a “Reset” pulse
4. Takes another measurement (Mreset)
5. Puts the following result in sensor’s data output register:
Output = [Mset – Mreset] / 2
Charge Current Limit
The current that reservoir capacitor (C1) can draw when charging is limited for both single supply and dual supply
configurations. This prevents drawing down the supply voltage (VDD).
www.honeywell.com
11
HMC5983
Temperature Compensation
Temperature compensation of the measured magnetic data is enabled by default at the factory. Temperature measured
by the built-in temperature sensor will be used to compensate the sensor’s sensitivity change due to temperature based
on the sensor’s typical sensitivity temperature coefficient. The compensated data will be placed in the Data Output
Registers automatically. Temperature sensor must be enabled (set CRA7 =1) for compensation to work.
Temperature Output
HMC5983 has a built-in temperature sensor that its output can be enabled by setting bit 7 of Configuration Register A
(CRA7). This bit is disabled at power-on by default. When this feature is enabled, a temperature measurement will be
taken at each magnetic measurement and the output is placed in Temperature Output Registers (0x31 and 0x32).
Automatic Offset Compensation
HMC5983 automatically adjusts the sensor’s internal (bridge) offset to zero before each measurement is taken. This
feature allows the full dynamic range of the sensor to be available for measuring the external magnetic field. This feature
is particularly important when the gain setting is high (lower GN#) because the dynamic range is smaller at higher gain. As
long as the sensor does not saturate within the full range of the external field to be measured, higher gain usually means
better resolution and better accuracy.
MODES OF OPERATION
This device has several operating modes whose primary purpose is power management and is controlled by the Mode
Register. This section describes these modes.
Continuous-Measurement Mode
During continuous-measurement mode, the device continuously makes measurements, at user selectable rate, and
places measured data in data output registers. Data can be re-read from the data output registers if necessary; however,
if the master does not ensure that the data register is accessed before the completion of the next measurement, the data
output registers are updated with the new measurement. To conserve current between measurements, the device is
placed in a state similar to idle mode, but the Mode Register is not changed to Idle Mode. That is, MD[n] bits are
unchanged. Settings in the Configuration Register A affect the data output rate (bits DO[n]), the measurement
configuration (bits MS[n]), when in continuous-measurement mode.
All registers maintain values while in continuousmeasurement mode. The I²C bus is enabled for use by other devices on the network in while continuous-measurement
mode.
Single-Measurement Mode
This is the default power-up mode. During single-measurement mode, the device makes a single measurement and
places the measured data in data output registers. After the measurement is complete and output data registers are
updated, the device is placed in idle mode, and the Mode Register is changed to idle mode by setting MD[n] bits. Settings
in the configuration register affect the measurement configuration (bits MS[n]) when in single-measurement mode. All
registers maintain values while in single-measurement mode. The I²C bus is enabled for use by other devices on the
network while in single-measurement mode.
Idle Mode
During this mode the device is accessible through the I²C bus, but major sources of power consumption are disabled,
such as, but not limited to, the ADC, the amplifier, and the sensor bias current. All registers maintain values while in idle
mode. The I²C bus is enabled for use by other devices on the network while in idle mode.
12
www.honeywell.com
HMC5983
REGISTERS
This device is controlled and configured via a number of on-chip registers, which are described in this section. In the
following descriptions, set implies a logic 1, and reset or clear implies a logic 0, unless stated otherwise.
Register List
The table below lists the registers and their access. All address locations are 8 bits.
Table2: Register List
Address Location
0x00
00
0x01
01
0x02
02
0x03
03
0x04
04
0x05
05
0x06
06
0x07
07
0x08
08
0x09
09
0x0A
10
0x0B
11
0x0C
12
0x31
49
0x32
50
Name
Access
Configuration Register A
Configuration Register B
Mode Register
Data Output X MSB Register
Data Output X LSB Register
Data Output Z MSB Register
Data Output Z LSB Register
Data Output Y MSB Register
Data Output Y LSB Register
Status Register
Identification Register A
Identification Register B
Identification Register C
Temperature Output MSB Register
Temperature Output LSB Register
Read/Write
Read/Write
Read/Write
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Register Access
This section describes the process of reading from and writing to this device. The devices uses an address pointer to
indicate which register location is to be read from or written to. These pointer locations are sent from the master to this
slave device and succeed the 7-bit address (0x1E) plus 1 bit read/write identifier, i.e. 0x3D for read and 0x3C for write.
To minimize the communication between the master and this device, the address pointer updated automatically without
master intervention. The register pointer will be incremented by 1 automatically after the current register has been read
successfully.
The address pointer value itself cannot be read via the I²C bus.
Any attempt to read an invalid address location returns 0’s, and any write to an invalid address location or an undefined bit
within a valid address location is ignored by this device.
To move the address pointer to a random register location, first issue a “write” to that register location with no data byte
following the commend. For example, to move the address pointer to register 10, send 0x3C 0x0A.
www.honeywell.com
13
HMC5983
Configuration Register A
The configuration register is used to configure the device for setting the data output rate and measurement configuration.
CRA0 through CRA7 indicate bit locations, with CRA denoting the bits that are in the configuration register. CRA7 denotes
the first bit of the data stream. The number in parenthesis indicates the default value of that bit.CRA default is 0x10.
Table 3: Configuration Register A
CRA7
CRA6
CRA5
CRA4
CRA3
CRA2
CRA1
CRA0
(0)
MA1(0)
MA0(0)
DO2 (1)
DO1 (0)
DO0 (0)
MS1 (0)
MS0 (0)
Table 4: Configuration Register A Bit Designations
Location
Name
CRA7
TS
CRA6 to CRA5
MA1 to MA0
CRA4 to CRA2
DO2 to DO0
CRA1 to CRA0
MS1 to MS0
Description
Set this bit to enable temperature sensor. Temperature
sensor will be measured at each magnetic measurement.
Enable Temperature sensor for automatic compensation of
Sensitivity over temperature.
Select number of samples averaged (1 to 8) per
measurement output.
00 = 1(Default); 01 = 2; 10 = 4; 11 = 8
Data Output Rate Bits. These bits set the rate at which data
is written to all three data output registers.
Measurement Configuration Bits. These bits define the
measurement flow of the device, specifically whether or not
to incorporate an applied bias into the measurement.
The Table below shows all selectable output rates in continuous measurement mode. All three channels shall be
measured within a given output rate. Other output rates with maximum rate of 160 Hz can be achieved by monitoring
DRDY interrupt pin in single measurement mode.
Table 5: Data Output Rates
14
DO2
DO1
DO0
Typical Data Output Rate (Hz)
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
0.75
1.5
3
7.5
15 (Default)
30
75
220
www.honeywell.com
HMC5983
Table 6: Measurement Modes
MS1
MS0
Measurement Mode
0
0
Normal measurement configuration (Default). In normal measurement
configuration the device follows normal measurement flow. The positive and
negative pins of the resistive load are left floating and high impedance.
0
1
Positive bias configuration for X, Y, and Z axes. In this configuration, a positive
current is forced across the resistive load for all three axes.
1
0
Negative bias configuration for X, Y and Z axes. In this configuration, a negative
current is forced across the resistive load for all three axes.
1
1
Temperature sensor only. Magnetic sensor will not be enabled during
measurement.
Configuration Register B
The configuration register B for setting the device gain. CRB0 through CRB7 indicate bit locations, with CRB denoting the
bits that are in the configuration register. CRB7 denotes the first bit of the data stream. The number in parenthesis
indicates the default value of that bit. CRB default is 0x20.
Table 7: Configuration B Register
CRB7
CRB6
CRB5
CRB4
CRB3
CRB2
CRB1
CRB0
GN2 (0)
GN1 (0)
GN0 (1)
(0)
(0)
(0)
(0)
(0)
Table 8: Configuration Register B Bit
Designations
Location
Name
Description
CRB7 to CRB5
GN2 to GN0
Gain Configuration Bits. These bits configure the gain for
the device. The gain configuration is common for all
channels.
CRB4 to CRB0
N/A
These bits must be cleared for correct operation.
www.honeywell.com
15
HMC5983
The table below shows nominal gain settings. Use the “Gain” column to convert counts to Gauss. The “Digital Resolution”
column is the theoretical value in term of milli-Gauss per count (LSb) which is the inverse of the values in the “Gain”
column. The effective resolution of the usable signal also depends on the noise floor of the system, i.e.
Effective Resolution = Max (Digital Resolution, Noise Floor)
Choose a lower gain value (higher GN#) when total field strength causes overflow in one of the data output registers
(saturation). Note that the very first measurement after a gain change maintains the same gain as the previous setting.
The new gain setting is effective from the second measurement and on.
Table 9: Gain Settings
GN2
16
GN1
GN0
Recommended
Sensor Field
Range
Gain
(LSb/
Gauss)
Digital
Resolution
(mG/LSb)
Output Range
0
0
0
± 0.88 Ga
1370
0.73
0xF800–0x07FF
(-2048–2047 )
0
0
1
± 1.3 Ga
1090 (default)
0.92
0xF800–0x07FF
(-2048–2047 )
0
1
0
± 1.9 Ga
820
1.22
0xF800–0x07FF
(-2048–2047 )
0
1
1
± 2.5 Ga
660
1.52
0xF800–0x07FF
(-2048–2047 )
1
0
0
± 4.0 Ga
440
2.27
0xF800–0x07FF
(-2048–2047 )
1
0
1
± 4.7 Ga
390
2.56
0xF800–0x07FF
(-2048–2047 )
1
1
0
± 5.6 Ga
330
3.03
0xF800–0x07FF
(-2048–2047 )
1
1
1
± 8.1 Ga
230
4.35
0xF800–0x07FF
(-2048–2047 )
www.honeywell.com
HMC5983
Mode Register
The mode register is an 8-bit register from which data can be read or to which data can be written. This register is used to
select the operating mode of the device. MR0 through MR7 indicate bit locations, with MR denoting the bits that are in the
mode register. MR7 denotes the first bit of the data stream. The number in parenthesis indicates the default value of that
bit. Mode register default is 0x01.
Table 10: Mode Register
MR7
MR6
MR5
MR4
MR3
MR2
MR1
MR0
(0)
(0)
(0)
(0)
(0)
(0)
MD1 (0)
MD0 (1)
Table 11: Mode Register Bit Designations
Location
Name
Description
MR7
HS
Set this pin to enable I²C High Speed mode, 3400 kHz.
MR6
N/A
Clear this bit for correct operation.
MR5
LP
Lowest power mode. When set, ODR=0.75 Hz, and
Averaging = 1.
MR4
N/A
This bit has no functionality.
MR3
N/A
Clear this bit for correct operation.
MR2
SIM
MR1 to
MR0
MD1 to
MD0
SPI serial interface mode selection:
0: 4-wire SPI interface
1: 3-wire SPI interface
Mode Select Bits. These bits select the operation mode of
this device.
Table 12: Operating Modes
MD1
www.honeywell.com
MD0
Operating Mode
Continuous-Measurement Mode. In continuous-measurement mode,
the device continuously performs measurements and places the
result in the data register. RDY goes high when new data is placed
in all three registers. After a power-on or a write to the mode or
configuration register, the first measurement set is available from all
three data output registers after a period of 2/fDO and subsequent
measurements are available at a frequency of fDO, where fDO is the
frequency of data output.
Single-Measurement Mode (Default). When single-measurement
mode is selected, device performs a single measurement, sets RDY
high and returned to idle mode. Mode register returns to idle mode
bit values. The measurement remains in the data output register and
RDY remains high until the data output register is read or another
measurement is performed.
0
0
0
1
1
0
Idle Mode. Device is placed in idle mode.
1
1
Idle Mode. Device is placed in idle mode.
17
HMC5983
Data Output X Registers A and B
The data output X registers are two 8-bit registers, data output register A and data output register B. These registers
store the measurement result from channel X. Data output X register A contains the MSB from the measurement result,
and data output X register B contains the LSB from the measurement result. The value stored in these two registers is a
16-bit value in 2’s complement form, whose range is 0xF800 to 0x07FF. DXRA0 through DXRA7 and DXRB0 through
DXRB7 indicate bit locations, with DXRA and DXRB denoting the bits that are in the data output X registers. DXRA7 and
DXRB7 denote the first bit of the data stream. The number in parenthesis indicates the default value of that bit.
In the event the ADC reading overflows or underflows for the given channel, or if there is a math overflow during the bias
measurement, this data register will contain the value -4096. This register value will clear when after the next valid
measurement is made.
Table 13: Data Output X Registers A and B
DXRA7
DXRA6
DXRA5
DXRA4
DXRA3
DXRA2
DXRA1
DXRA0
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
DXRB7
DXRB6
DXRB5
DXRB4
DXRB3
DXRB2
DXRB1
DXRB0
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
Data Output Y Registers A and B
The data output Y registers are two 8-bit registers, data output register A and data output register B. These registers
store the measurement result from channel Y. Data output Y register A contains the MSB from the measurement result,
and data output Y register B contains the LSB from the measurement result. The value stored in these two registers is a
16-bit value in 2’s complement form, whose range is 0xF800 to 0x07FF. DYRA0 through DYRA7 and DYRB0 through
DYRB7 indicate bit locations, with DYRA and DYRB denoting the bits that are in the data output Y registers. DYRA7 and
DYRB7 denote the first bit of the data stream. The number in parenthesis indicates the default value of that bit.
In the event the ADC reading overflows or underflows for the given channel, or if there is a math overflow during the bias
measurement, this data register will contain the value -4096. This register value will clear when after the next valid
measurement is made.
Table 14: Data Output Y Registers A and B
DYRA7
DYRA6
DYRA5
DYRA4
DYRA3
DYRA2
DYRA1
DYRA0
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
DYRB7
DYRB6
DYRB5
DYRB4
DYRB3
DYRB2
DYRB1
DYRB0
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
Data Output Z Registers A and B
The data output Z registers are two 8-bit registers, data output register A and data output register B. These registers
store the measurement result from channel Z. Data output Z register A contains the MSB from the measurement result,
and data output Z register B contains the LSB from the measurement result. The value stored in these two registers is a
16-bit value in 2’s complement form, whose range is 0xF800 to 0x07FF. DZRA0 through DZRA7 and DZRB0 through
DZRB7 indicate bit locations, with DZRA and DZRB denoting the bits that are in the data output Z registers. DZRA7 and
DZRB7 denote the first bit of the data stream. The number in parenthesis indicates the default value of that bit.
In the event the ADC reading overflows or underflows for the given channel, or if there is a math overflow during the bias
measurement, this data register will contain the value -4096. This register value will clear when after the next valid
measurement is made.
18
www.honeywell.com
HMC5983
Table 15: Data Output Z Registers A and B
DZRA7
DZRA6
DZRA5
DZRA4
DZRA3
DZRA2
DZRA1
DZRA0
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
DZRB7
DZRB6
DZRB5
DZRB4
DZRB3
DZRB2
DZRB1
DZRB0
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
Data Output Register Operation
When one or more of the output registers are read, new data cannot be placed in any of the output data registers until all
six data output registers are read. This requirement also impacts DRDY and RDY, which cannot be cleared until new
data is placed in all the output registers.
Status Register
The status register is an 8-bit read-only register. This register is used to indicate device status. SR0 through SR7
indicate bit locations, with SR denoting the bits that are in the status register. SR7 denotes the first bit of the data stream.
Table 16: Status Register
www.honeywell.com
SR7
SR6
SR5
SR4
SR3
SR2
SR1
SR0
(0)
(0)
(0)
(0)
(0)
(0)
LOCK (0)
RDY(0)
19
HMC5983
Table 17: Status Register Bit Designations
Location
Name
Description
SR7 to
SR5
0
These bits are reserved.
SR4
DOW
Data Over Written. Set when the measurement data are
not read before the subsequent data measurements are
posted to the output registers. This happens when master
device skips reading one or more data samples. Bit is
cleared at the beginning of a data read.
DR3 to
DR2
N/A
Reserved.
SR1
LOCK
SR0
RDY
Data output register lock. This bit is set when:
1.some but not all of of the six data output registers have
been read,
2. Mode register has been read.
When this bit is set, the six data output registers are locked
and any new data will not be placed in these register until
one of these conditions are met:
1.all six bytes have been read and the next measurement
starts,
2. The mode register is written,
3. The measurement configuration (CRA) is written,
4. Power is reset.
Ready Bit. Set when data is written to all six data registers.
Cleared when device initiates a write to the data output
registers and after one or more of the data output registers
are written to. When RDY bit is clear it shall remain cleared
for >200 μs. DRDY pin can be used as an alternative to
the status register for monitoring the device for
measurement data.
Identification Register A
The identification register A is used to identify the device. IRA0 through IRA7 indicate bit locations, with IRA denoting the
bits that are in the identification register A. IRA7 denotes the first bit of the data stream. The number in parenthesis
indicates the default value of that bit.
The identification value for this device is stored in this register. This is a read-only register.
Register values. ASCII value H
Table 18: Identification Register A Default Values
20
IRA7
IRA6
IRA5
IRA4
IRA3
IRA2
IRA1
IRA0
0
1
0
0
1
0
0
0
www.honeywell.com
HMC5983
Identification Register B
The identification register B is used to identify the device. IRB0 through IRB7 indicate bit locations, with IRB denoting the
bits that are in the identification register A. IRB7 denotes the first bit of the data stream.
Register values. ASCII value 4
Table 19: Identification Register B Default Values
IRB7
IRB6
IRB5
IRB4
IRB3
IRB2
IRB1
IRB0
0
0
1
1
0
1
0
0
Identification Register C
The identification register C is used to identify the device. IRC0 through IRC7 indicate bit locations, with IRC denoting the
bits that are in the identification register A. IRC7 denotes the first bit of the data stream.
Register values. ASCII value 3
Table 20: Identification Register C Default Values
IRC7
IRC6
IRC5
IRC4
IRC3
IRC2
IRC1
IRC0
0
0
1
1
0
0
1
1
Temperature Output Registers H and L
The temperature output registers are two 8-bit registers, temperature output register H and temperature output register L.
These registers store the measurement result from the internal temperature sensor. Temperature output register H
contains the MSB from the measurement result, and temperature output register L contains the LSB from the
measurement result. The value stored in these two registers is a 16-bit value in 2’s complement form, whose range is
0xF800 to 0x07FF. TEMPH0 through TEMPH7 and TEMPL0 through TEMPL7 indicate bit locations, with TEMPH and
TEMPL denoting the bits that are in the temperature output registers. TEMPH7 and TEMPL7 denote the first bit of the
data stream. The number in parenthesis indicates the default value of that bit.
Table 21: Temperature Output Registers H and L
TEMPH7
TEMPH 6
TEMPH 5
TEMPH 4
TEMPH 3
TEMPH 2
TEMPH 1
TEMPH 0
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
TEMPL 7
TEMPL 6
TEMPL 5
TEMPL 4
TEMPL 3
TEMPL 2
TEMPL 1
TEMPL 0
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
Temperature output in C is related to the temperature output register values as follows.
Temperature = (MSB * 2^8 + LSB) / (2^4 * 8) + 25 in C
www.honeywell.com
21
HMC5983
I²C COMMUNICATION PROTOCOL
If selected, the HMC5983 communicates via a two-wire I²C bus system as a slave device. The HMC5983 uses a simple
protocol with the interface protocol defined by the I²C bus specification, and by this document. The data rate is at the
standard-mode 100kbps, 400kbps, or 3400kbps rates as defined in the I²C Bus Specifications. The bus bit format is an 8bit Data/Address send and a 1-bit acknowledge bit. The format of the data bytes (payload) shall be case sensitive ASCII
characters or binary data to the HMC5983 slave, and binary data returned. Negative binary values will be in two’s
complement form. The default (factory) HMC5983 8-bit slave address is 0x3C for write operations, or 0x3D for read
operations.
The HMC5983 Serial Clock (SCL) and Serial Data (SDA) lines require resistive pull-ups (Rp) between the master device
(usually a host microprocessor) and the HMC5983. Pull-up resistance values of about 2.2K to 10K ohms are
recommended with a nominal VDDIO voltage. Other resistor values may be used as defined in the I²C Bus Specifications
that can be tied to VDDIO.
The SCL and SDA lines in this bus specification may be connected to multiple devices. The bus can be a single master to
multiple slaves, or it can be a multiple master configuration. All data transfers are initiated by the master device, which is
responsible for generating the clock signal, and the data transfers are 8 bit long. All devices are addressed by I²C ’s
th
unique 7-bit address. After each 8-bit transfer, the master device generates a 9 clock pulse, and releases the SDA line.
The receiving device (addressed slave) will pull the SDA line low to acknowledge (ACK) the successful transfer or leave
the SDA high to negative acknowledge (NACK).
Per the I²C spec, all transitions in the SDA line must occur when SCL is low. This requirement leads to two unique
conditions on the bus associated with the SDA transitions when SCL is high. Master device pulling the SDA line low while
the SCL line is high indicates the Start (S) condition, and the Stop (P) condition is when the SDA line is pulled high while
the SCL line is high. The I²C protocol also allows for the Restart condition in which the master device issues a second
start condition without issuing a stop.
All bus transactions begin with the master device issuing the start sequence followed by the slave address byte. The
address byte contains the slave address; the upper 7 bits (bits7-1), and the Least Significant bit (LSb). The LSb of the
th
address byte designates if the operation is a read (LSb=1) or a write (LSb=0). At the 9 clock pulse, the receiving slave
device will issue the ACK (or NACK). Following these bus events, the master will send data bytes for a write operation, or
the slave will clock out data with a read operation. All bus transactions are terminated with the master issuing a stop
sequence.
I²C bus control can be implemented with either hardware logic or in software. Typical hardware designs will release the
SDA and SCL lines as appropriate to allow the slave device to manipulate these lines. In a software implementation, care
must be taken to perform these tasks in code.
SPI COMMUNICATION PROTOCOL
If selected, the HMC5983 communicates via a 3-wire or 4-wire SPI bus as a slave device. The SPI allows writing and
reading the registers of the device.
The standard Serial Interface interacts with the outside world with 4 wires: CS, SCK, SDI and SDO that correspond to
commonly used notations SS, SCK, MOSI and MISO, respectively.
22
www.honeywell.com
HMC5983
Read and Write protocol
Figure 1: Read & Write Protocol
CS (SPI_CS) is the Serial Port Enable and it is controlled by the SPI master. It goes low at the start of the transmission
and goes back high at the end. SCK (SPI_SCK) is the Serial Port Clock and it is controlled by the SPI master. It is
stopped high when CS is high (no transmission). SDI (SPI_SDI) and SDO (SPI_SDO) are respectively the Serial Port
Data Input and Output. Those lines are driven at the falling edge of SCK and should be captured at the rising edge of
SCK.
Both the Read Register and Write Register commands are completed in 16 clocks pulses or in multiple of 8 in case of
multiple byte read/write. Bit duration is the time between two falling edges of SCK. The first bit (bit 0) starts at the first
falling edge of SCK after the falling edge of CS while the last bit (bit 15, bit 23, ...) starts at the last falling edge of SCK
(SPI_CS) just before the rising edge of CS.
bit 0: RW bit. When 0, the data DI(7:0) is written into the device. When 1, the data DO(7:0) from the device is read. In
latter case, the chip will drive SDO at the start of bit 8.
bit 1: MS bit. When 0, the address will remain unchanged in multiple read/write commands. When 1, the address will be
auto incremented in multiple read/write commands.
bit 2-7: address AD(5:0). This is the address field of the indexed register.
bit 8-15: data DI(7:0) (write mode). This is the data that will be written into the device (MSb first).
bit 8-15: data DO(7:0) (read mode). This is the data that will be read from the device (MSb first).
In multiple read/write commands further blocks of 8 clock periods will be added. When MS bit is 0 the address used to
read/write data remains the same for every block. When MS bit is 1 the address used to read/write data is incremented at
every block.
The function and the behavior of SDI and SDO remain unchanged.
www.honeywell.com
23
HMC5983
SPI Read
Figure 2: SPI Read Protocol
The SPI Read command is performed with 16 clocks pulses. Multiple byte read command is performed adding blocks of 8
clocks pulses at the previous one.
bit 0: READ bit. The value is 1.
bit 1: MS bit. When 0 do not increment address, when 1 increment address in multiple reading.
bit 2-7: address AD(5:0). This is the address field of the indexed register.
bit 8-15: data DO(7:0) (read mode). This is the data that will be read from the device (MSb first).
bit 16-... : data DO(...-8). Further data in multiple byte reading.
Figure 3: Multiple Bytes SPI Read Protocol (2 bytes example)
SPI Write
Figure 4: SPI Write Protocol
24
www.honeywell.com
HMC5983
The SPI Write command is performed with 16 clocks pulses. Multiple byte write command is performed adding blocks of 8
clocks pulses at the previous one.
bit 0: WRITE bit. The value is 0.
bit 1: MS bit. When 0 do not increment address, when 1 increment address in multiple writing.
bit 2 -7: address AD(5:0). This is the address field of the indexed register.
bit 8-15: data DI(7:0) (write mode). This is the data that will be written inside the device (MSb first).
bit 16-... : data DI(...-8). Further data in multiple byte writing.
Figure 5: Multiple bytes SPI Write Protocol (2 bytes example)
SPI Read in 3-wires mode
3-wires mode is entered by setting to 1 bit SIM (SPI Serial Interface Mode selection) in MODE_REG(2).
Figure 6: SPI Read Protocol in 3-wires Mode
The SPI Read command is performed with 16 clocks pulses:
bit 0: READ bit. The value is 1.
bit 1: MS bit. When 0 do not increment address, when 1 increment address in multiple reading.
bit 2-7: address AD(5:0). This is the address field of the indexed register.
bit 8-15: data DO(7:0) (read mode). This is the data that will be read from the device (MSb first).
Multiple write command is also available in 3-wires mode.
www.honeywell.com
25
HMC5983
I²C OPERATIONAL EXAMPLES
The HMC5983 has a fairly quick stabilization time from no voltage to stable and ready for data retrieval. The nominal 56
milli-seconds with the factory default single measurement mode means that the six bytes of magnetic data registers
(DXRA, DXRB, DZRA, DZRB, DYRA, and DYRB) are filled with a valid first measurement.
To change the measurement mode to continuous measurement mode, after the power-up time send the three bytes:
0x3C 0x02 0x00
This writes the 00 into the second register or mode register to switch from single to continuous measurement mode
setting. With the data rate at the factory default of 15Hz updates, a 67 milli-second typical delay should be allowed by the
I²C master before querying the HMC5983 data registers for new measurements. To clock out the new data, send:
0x3D, and clock out DXRA, DXRB, DZRA, DZRB, DYRA, and DYRB located in registers 3 through 8. The HMC5983 will
automatically re-point back to register 3 for the next 0x3D query. All six data registers must be read properly before new
data can be placed in any of these data registers.
Below is an example of a (power-on) initialization process for “continuous-measurement mode” via I²C interface:
1.
2.
3.
4.
5.
Write CRA (00) – send 0x3C 0x00 0x70 (8-average, 15 Hz default, normal measurement)
Write CRB (01) – send 0x3C 0x01 0xA0 (Gain=5, or any other desired gain)
Write Mode (02) – send 0x3C 0x02 0x00 (Continuous-measurement mode)
Wait 6 ms or monitor status register or DRDY hardware interrupt pin
Loop
Send 0x3D 0x06 (Read all 6 bytes. If gain is changed then this data set is using previous gain)
Convert three 16-bit 2’s compliment hex values to decimal values and assign to X, Z, Y, respectively.
Send 0x3C 0x03 (point to first data register 03)
Wait about 67 ms (if 15 Hz rate) or monitor status register or DRDY hardware interrupt pin
End_loop
Below is an example of a (power-on) initialization process for “single-measurement mode” via I²C interface:
1. Write CRA (00) – send 0x3C 0x00 0x70 (8-average, 15 Hz default or any other rate, normal measurement)
2. Write CRB (01) – send 0x3C 0x01 0xA0 (Gain=5, or any other desired gain)
3. For each measurement query:
Write Mode (02) – send 0x3C 0x02 0x01 (Single-measurement mode)
Wait 6 ms or monitor status register or DRDY hardware interrupt pin
Send 0x3D 0x06 (Read all 6 bytes. If gain is changed then this data set is using previous gain)
Convert three 16-bit 2’s compliment hex values to decimal values and assign to X, Z, Y, respectively.
SPI OPERATIONAL EXAMPLES
To read Configuration B register
Lower CS line
Write 0x81 to the SPI bus
Read 1 byte from SPI bus
Raise CS line
To read Status
Lower CS line
Write 0x89 to the SPI bus
Read 1 byte from SPI bus
Raise CS line
To write Configuration B register
Lower CS line
Write 0x01 to the SPI bus
Write 0xVV to the SPI bus (VV is the value to
be written to register B)
Raise CS line
To read output
Lower CS line
Write 0xC3 to the SPI bus
Read 6 byte from SPI bus
Raise CS line
26
www.honeywell.com
HMC5983
SELF TEST OPERATION
To check the HMC5983 for proper operation, a self test feature is incorporated in which the sensor offset straps are
excited to create a nominal field strength (bias field) to be measured. To implement self test, the least significant bits (MS1
and MS0) of configuration register A are changed from 00 to 01 (positive bias) or 10 (negative bias).
Then, by placing the mode register into single or continuous-measurement mode, two data acquisition cycles will be made
on each magnetic vector. The first acquisition will be a set pulse followed shortly by measurement data of the external
field. The second acquisition will have the offset strap excited (about 10 mA) in the positive bias mode for X, Y, and Z
axes to create about a 1.1 gauss self test field plus the external field. The first acquisition values will be subtracted from
the second acquisition, and the net measurement will be placed into the data output registers.
Since self test adds ~1.1 Gauss additional field to the existing field strength, using a reduced gain setting prevents the
sensor from being saturated and the data registers from overflowing. For example, if the configuration register B is set to
0xA0 (Gain=5), values around +452 LSb (1.16 Ga * 390 LSb/Ga) will be placed in the X and Y data output registers and
around +421 (1.08 Ga * 390 LSb/Ga) will be placed in Z data output register. To leave the self test mode, change MS1
and MS0 bit of the configuration register A back to 00 (Normal Measurement Mode). Acceptable limits of the self test
values depend on the gain setting. Limits for Gain=5 are provided in the specification table.
Below is an example of a “positive self test” process using continuous-measurement mode via I²C interface:
Write CRA (00) – send 0x3C 0x00 0x71 (8-average, 15 Hz default, positive self test measurement)
Write CRB (01) – send 0x3C 0x01 0xA0 (Gain=5)
Write Mode (02) – send 0x3C 0x02 0x00 (Continuous-measurement mode)
Wait 6 ms or monitor status register or DRDY hardware interrupt pin
Loop
Send 0x3D 0x06 (Read all 6 bytes. If gain is changed then this data set is using previous gain)
Convert three 16-bit 2’s compliment hex values to decimal values and assign to X, Z, Y, respectively.
Send 0x3C 0x03 (point to first data register 03)
Wait about 67 ms (if 15 Hz rate) or monitor status register or DRDY hardware interrupt pin
End_loop
6. Check limits –
If all 3 axes (X, Y, and Z) are within reasonable limits (243 to 575 for Gain=5, adjust these limits based on the gain
setting used. See an example below.) Then
All 3 axes pass positive self test
Write CRA (00) – send 0x3C 0x00 0x70 (Exit self test mode and this procedure)
Else
If Gain<7
Write CRB (01) – send 0x3C 0x01 0xn0 (Increase gain setting to next value;n, and retry. Skip the
next data set)
Else
At least one axis did not pass positive self test
Write CRA (00) – send 0x3C 0x00 0x70 (Exit self test mode and this procedure)
End If
1.
2.
3.
4.
5.
Below is an example of how to adjust the “positive self test” limits based on the gain setting:
1. If Gain = 6, self test limits are:
Low Limit = 243 * 330/390 = 206
High Limit = 575 * 330/390 = 487
2. If Gain = 7, self test limits are:
Low Limit = 243 * 230/390 = 143
High Limit = 575 * 230/390 = 339
www.honeywell.com
27
HMC5983
ORDERING INFORMATION
Ordering Number
HMC5983-TR
Product
Tape and Reel 4k pieces/reel
FIND OUT MORE
For more information on Honeywell’s Magnetic Sensors visit us online at www.magneticsensors.com or contact us at 800323-8295 (763-954-2474 internationally).
The application circuits herein constitute typical usage and interface of Honeywell product. Honeywell does not warranty
or assume liability of customer-designed circuits derived from this description or depiction.
Honeywell reserves the right to make changes to improve reliability, function or design. Honeywell does not assume any
liability arising out of the application or use of any product or circuit described herein; neither does it convey any license
under its patent rights nor the rights of others.
U.S. Patents 4,441,072, 4,533,872, 4,569,742, 4,681,812, 4,847,584 and 6,529,114 apply to the technology described
Honeywell
12001 Highway 55
Plymouth, MN 55441
Tel: 800-323-8295
www.magneticsensors.com
28
Form # 900425
January 2012
©2011 Honeywell International Inc.
www.honeywell.com