RID-125 125W Dual Output Switching Power Supply series Features : Isolated output & GND for CH1,CH2 AC input range selectable by switch Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage All using 105 long life electrolytic capacitors Withstand 5G vibration test LED indicator for power on 100% full load burn-in test High realibility 3 years warranty SPECIFICATION OUTPUT RID-125-2448 OUTPUT NUMBER CH1 CH2 CH1 CH2 CH1 CH2 DC VOLTAGE 12V 24V 12V 48V 24V 48V RATED CURRENT 3.7A 3.7A 2.3A 2.3A 2A 2A 0.4 ~ 5A 1 ~ 7A 0.2 ~ 2.5A 0.5 ~ 4A 0.2 ~ 2.5A CURRENT RANGE Note.6 1 ~ 7A RATED POWER Note.6 133.2W 138W RIPPLE & NOISE (max.) Note.2 120mVp-p CH1: 11.4 ~ 13.2V VOLTAGE TOLERANCE Note.3 2.0% 144W 200mVp-p 120mVp-p +8,-5% CH1: 11.4 ~ 13.2V 2.0% VOLTAGE ADJ. RANGE 240mVp-p 200mVp-p +8,-5% CH1: 22.8 ~ 26.4V 1.0% 240mVp-p 4.0% LINE REGULATION Note.4 0.5% 1.0% 0.5% 1.0% 0.5% 1.0% LOAD REGULATION Note.5 1.0% 5.0% 1.0% 5.0% 1.0% 3.0% SETUP, RISE TIME INPUT RID-125-1248 RID-125-1224 MODEL 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load HOLD UP TIME (Typ.) 36ms/230VAC VOLTAGE RANGE 88 ~ 132VAC / 176 ~ 264VAC selected by switch 30ms/115VAC at full load FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY(Typ.) 85% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 3A/115VAC 2A/230VAC COLD START 40A/230VAC LEAKAGE CURRENT 248 ~ 373VDC(300VAC peak 5sec. No damage) 85% 86% <2mA / 240VAC 110 ~ 150% rated output power OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY & EMC (Note 7) OTHERS SAFETY STANDARDS WITHSTAND VOLTAGE CH1: 27.6 ~ 32.4V Protection type : Hiccup mode, recovers automatically after fault condition is removed -20 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 )on CH1 output 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B / 70% RH HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY MTBF Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2), heavy industry level, criteria A DIMENSION PACKING NOTE Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 13.8 ~ 16.2V CH1: 13.8 ~ 16.2V 218.2Khrs min. MIL-HDBK-217F (25 199*98*38mm (L*W*H) 0.7Kg; 20pcs/15Kg/0.8CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load. 6. Each output can work within current range. But total output power can't exceed rated output power. 7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. File Name:RID-125-SPEC 2010-10-18 RID-125 125W Dual Output Switching Power Supply series Features : Isolated output & GND for CH1,CH2 AC input range selectable by switch Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage 170% peak load for CH1 All using 105 long life electrolytic capacitors Withstand 5G vibration test LED indicator for power on 100% full load burn-in test High realibility 3 years warranty SPECIFICATION RID-125-1205 MODEL CH1 CH2 CH1 DC VOLTAGE 12V 5V 24V 5V RATED CURRENT 9.2A 3A 4.6A 3A INPUT CH2 CURRENT RANGE Note.6 2 ~ 10.5A 0 ~ 3A 2 ~ 5.3A 0 ~ 3A PEAK LOAD Note.9 15.6A 3A 7.8A 3A 125.4W RATED POWER OUTPUT RID-125-2405 OUTPUT NUMBER 125.4W RIPPLE & NOISE (max.) Note.2 120mVp-p 80mVp-p 120mVp-p VOLTAGE ADJ. RANGE CH1: 11.4 ~ 13.2V VOLTAGE TOLERANCE Note.3 2.0% CH1: 22.8 ~ 26.4V 2.0% 3.0% 80mVp-p 3.0% LINE REGULATION Note.4 0.5% 0.5% 0.5% 0.5% LOAD REGULATION Note.5 1.0% 2.0% 1.0% 2.0% SETUP, RISE TIME 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load HOLD UP TIME (Typ.) 35ms/230VAC VOLTAGE RANGE 88 ~ 132VAC / 176 ~ 264VAC selected by switch FREQUENCY RANGE 47 ~ 63Hz 30ms/115VAC at full load EFFICIENCY(Typ.) 80% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 3A/115VAC 2A/230VAC COLD START 40A/230VAC LEAKAGE CURRENT 248 ~ 373VDC(300VAC peak 5sec., no damage) 83% <2mA / 240VAC >165% rated output power OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY & EMC (Note 7) OTHERS SAFETY STANDARDS WITHSTAND VOLTAGE Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 )on CH1 output 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B / 70% RH HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY MTBF Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2), heavy industry level, criteria A DIMENSION PACKING NOTE Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 13.8 ~ 16.2V CH1: 27.6 ~ 32.4V 218.2Khrs min. MIL-HDBK-217F (25 199*98*38mm (L*W*H) 0.7Kg; 20pcs/15Kg/0.8CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load. 6. Each output can work within current range. But total output power can't exceed rated output power. 7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. 9. 10% duty cycle maximum within every second. Average output power should not exceed the rated power. File Name:RID-125-SPEC 2010-10-18 RID-125 125W Dual Output Switching Power Supply Mechanical Specification Case No. 902A series Unit:mm 7 3.5 9 12 197 1 9.5 2 98 80 4 85.5 3 8.2 5 6 7 4- 3.5 M 3 57.5 4.5 120 199 190 6.5 3.5 38 3 28.5 3.5 3-M 18 18 9 9.5 Terminal Pin No. Assignment Assignment Assignment Pin No. Pin No. DC OUTPUT +V2 AC/L 1 5 DC OUTPUT COM1 AC/N 2 6 DC OUTPUT +V1 3 7 FG DC OUTPUT COM2 4 157 22 Block Diagram fosc : 60KHz 230 115 RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING RECTIFIERS & FILTER +V2 COM2 RECTIFIERS & FILTER +V1 COM1 DETECTION CIRCUIT FG O.L.P. CONTROL O.V.P. Derating Curve Static Characteristics Ta=25 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -25 0 10 20 30 40 45 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 88 176 95 190 100 200 115 230 120 240 132 264 INPUT VOLTAGE (VAC) 60Hz File Name:RID-125-SPEC 2010-10-18