MEANWELL RQ

RQ-65
65W Quad Output Switching Power Supply
series
Features :
Universal AC input / Full range
Protections:Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105
long life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
..
SPECIFICATION
MODEL
OUTPUT
INPUT
RQ-65B
CH2
CH3
CH4
CH1
CH2
CH3
CH4
CH1
CH2
CH3
DC VOLTAGE
5V
12V
-5V
-12V
5V
15V
-5V
-15V
5V
12V
24V
-12V
RATED CURRENT
6A
2A
0.5A
0.5A
5A
2A
0.5A
0.5A
4A
1.5A
1A
0.5A
0.2 ~ 3A
0 ~ 1A
0 ~ 1A
0.5 ~ 8A
0.2 ~ 3A
0 ~ 1A
0 ~ 1A
0.5 ~ 8A
0.2 ~ 3A
0.1 ~ 1.5A 0 ~ 1A
CURRENT RANGE
Note.6 0.5 ~ 8A
RATED POWER
Note.6 62.5W
65W
CH4
68W
RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 80mVp-p 80mVp-p 80mVp-p 120mVp-p 80mVp-p 80mVp-p 80mVp-p 120mVp-p 180mVp-p 80mVp-p
VOLTAGE ADJ. RANGE
CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
+7,-5%
5.0%
5.0%
LINE REGULATION
Note.4
0.5%
1.5%
0.5%
0.5%
0.5%
LOAD REGULATION
Note.5
0.5%
3.0%
1.0%
1.0%
0.5%
SETUP, RISE TIME
500ms, 20ms/230VAC
HOLD UP TIME (Typ.)
60ms/230VAC
VOLTAGE RANGE
88 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
76%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
2A/115VAC
1.2A/230VAC
COLD START 40A/230VAC
LEAKAGE CURRENT
<2mA / 240VAC
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 7)
EMC EMISSION
EMC IMMUNITY
NOTE
RQ-65D
CH1
PROTECTION
OTHERS
RQ-65C
OUTPUT NUMBER
CH1: 4.75 ~ 5.5V
2.0%
+10,-4%
CH1: 4.75 ~ 5.5V
2.0%
6.0%
5.0%
5.0%
8.0%
5.0%
1.5%
0.5%
0.5%
0.5%
1.5%
2.0%
0.5%
4.0%
1.0%
1.0%
0.5%
3.0%
5.0%
1.0%
1200ms, 30ms/115VAC at full load
14ms/115VAC at full load
125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
76%
78%
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-25 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )on +5V output
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
MTBF
245.5Khrs min.
DIMENSION
PACKING
129*98*38mm (L*W*H)
0.44Kg; 30pcs/13.2Kg/0.72CUFT
MIL-HDBK-217F (25
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:RQ-65-SPEC 2011-08-19
RQ-65
65W Quad Output Switching Power Supply
Mechanical Specification
Case No. 903
series
Unit:mm
31
3.5
7
122.5
1
33
4
5
98
2-
M3
3
85.5
8.25
2
7
6
7
8
3 .5
73.5
4.5
129
6.5
Terminal Pin No. Assignment
32
Pin No.
1
2
3
4
38
28.5
3
3.5
9.5
3.5
3-M
18
18.5
9
120
Assignment
AC/L
AC/N
FG
DC OUTPUT -V4
Pin No.
5
6
7
8
Assignment
DC OUTPUT V3
DC OUTPUT +V2
DC OUTPUT COM
DC OUTPUT +V1
77
Block Diagram
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
POWER
SWITCHING
RECTIFIERS
&
FILTER
+V4
RECTIFIERS
&
FILTER
+V3
RECTIFIERS
&
FILTER
+V2
RECTIFIERS
&
FILTER
+V1
COM
DETECTION
CIRCUIT
FG
O.L.P.
fosc : 60KHz
CONTROL
O.V.P.
Derating Curve
Output Derating VS Input Voltage
Ta=25
100
80
LOAD (%)
LOAD (%)
60
40
20
-25
-25
0
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70 (VERTICAL)
88
95
100
115
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:RQ-65-SPEC 2011-08-19