RQ-65 65W Quad Output Switching Power Supply series Features : Universal AC input / Full range Protections:Short circuit / Overload / Over voltage Cooling by free air convection LED indicator for power on 100% full load burn-in test All using 105 long life electrolytic capacitors Withstand 300VAC surge input for 5 second High operating temperature up to 70 Withstand 5G vibration test High efficiency, long life and high reliability 3 years warranty .. SPECIFICATION MODEL OUTPUT INPUT RQ-65B CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 DC VOLTAGE 5V 12V -5V -12V 5V 15V -5V -15V 5V 12V 24V -12V RATED CURRENT 6A 2A 0.5A 0.5A 5A 2A 0.5A 0.5A 4A 1.5A 1A 0.5A 0.2 ~ 3A 0 ~ 1A 0 ~ 1A 0.5 ~ 8A 0.2 ~ 3A 0 ~ 1A 0 ~ 1A 0.5 ~ 8A 0.2 ~ 3A 0.1 ~ 1.5A 0 ~ 1A CURRENT RANGE Note.6 0.5 ~ 8A RATED POWER Note.6 62.5W 65W CH4 68W RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 80mVp-p 80mVp-p 80mVp-p 120mVp-p 80mVp-p 80mVp-p 80mVp-p 120mVp-p 180mVp-p 80mVp-p VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% +7,-5% 5.0% 5.0% LINE REGULATION Note.4 0.5% 1.5% 0.5% 0.5% 0.5% LOAD REGULATION Note.5 0.5% 3.0% 1.0% 1.0% 0.5% SETUP, RISE TIME 500ms, 20ms/230VAC HOLD UP TIME (Typ.) 60ms/230VAC VOLTAGE RANGE 88 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 76% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2A/115VAC 1.2A/230VAC COLD START 40A/230VAC LEAKAGE CURRENT <2mA / 240VAC OVERLOAD OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 7) EMC EMISSION EMC IMMUNITY NOTE RQ-65D CH1 PROTECTION OTHERS RQ-65C OUTPUT NUMBER CH1: 4.75 ~ 5.5V 2.0% +10,-4% CH1: 4.75 ~ 5.5V 2.0% 6.0% 5.0% 5.0% 8.0% 5.0% 1.5% 0.5% 0.5% 0.5% 1.5% 2.0% 0.5% 4.0% 1.0% 1.0% 0.5% 3.0% 5.0% 1.0% 1200ms, 30ms/115VAC at full load 14ms/115VAC at full load 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) 76% 78% 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +70 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 )on +5V output 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A MTBF 245.5Khrs min. DIMENSION PACKING 129*98*38mm (L*W*H) 0.44Kg; 30pcs/13.2Kg/0.72CUFT MIL-HDBK-217F (25 ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load. 6. Each output can work within current range. But total output power can't exceed rated output power. 7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) File Name:RQ-65-SPEC 2011-08-19 RQ-65 65W Quad Output Switching Power Supply Mechanical Specification Case No. 903 series Unit:mm 31 3.5 7 122.5 1 33 4 5 98 2- M3 3 85.5 8.25 2 7 6 7 8 3 .5 73.5 4.5 129 6.5 Terminal Pin No. Assignment 32 Pin No. 1 2 3 4 38 28.5 3 3.5 9.5 3.5 3-M 18 18.5 9 120 Assignment AC/L AC/N FG DC OUTPUT -V4 Pin No. 5 6 7 8 Assignment DC OUTPUT V3 DC OUTPUT +V2 DC OUTPUT COM DC OUTPUT +V1 77 Block Diagram RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING RECTIFIERS & FILTER +V4 RECTIFIERS & FILTER +V3 RECTIFIERS & FILTER +V2 RECTIFIERS & FILTER +V1 COM DETECTION CIRCUIT FG O.L.P. fosc : 60KHz CONTROL O.V.P. Derating Curve Output Derating VS Input Voltage Ta=25 100 80 LOAD (%) LOAD (%) 60 40 20 -25 -25 0 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 (VERTICAL) 88 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:RQ-65-SPEC 2011-08-19