︳ CFM150M SERIES 150W MEDICAL OPEN FRAME AC-DC MODULES WITH PFC Features * Universal Input Range 90 ~ 264VAC * Meets EN60601-1 and EN55011 Class B * 3”x 5” Compact Size * Less than 1 U high:1.05” * Industry Standard Pin Out * Active PFC Meets EN61000-3-2 * High Efficiency up to 92% * Meets CISPR/FCC Class B * Remote Voltage Sense * Over Voltage Protection * Continuous Short Circuit Protection * No load Power Consumption<0.5W MODEL OUTPUT VOLTAGE MAX. LOAD MIN. LOAD RIPPLE & NOISE VOLTAGE ACCURACY LINE REGULATION LOAD REGULATION % EFF. (Typ.) CFM150M120 12V 12.5A 0A 1% ±1% ±0.5% ±1% 90% CFM150M240 24V 6.25A 0A 1% ±1% ±0.5% ±1% 92% CFM150M360 36V 4.17A 0A 1% ±1% ±0.5% ±1% 93% CFM150M480 48V 3.13A 0A 1% ±1% ±0.5% ±1% 93% 1 Specifications CFM150M Series Derating Curve INPUT SPECIFICATIONS: OUTPUT SPECIFICATIONS: Holdup Time …………………………………………………………... 16ms typ. Short Circuit Protection ……….…….………… Hiccup mode(Auto Recovery) Adjustment Range on Vout ………………………………………………. ±5% Over Voltage Protection ………………………… Recycle AC input to restart Temperature Coefficient ……………………..............................… ±0.05%/℃ Rated Load(%) 100% Voltage …....………........…........................................... 90~264Vac Frequency ………………………………………….……………..... 47 to 63Hz Inrush Current ………………….……………................. 110A max. @240Vac Leakage Current ………………………………………….…...…… 300uA max. 80% 60% 20 LFM(Natural C onve cti on) 40% 20% 0% -20 -10 0 10 20 30 40 50 60 70 o Ambient Temperature( C) GENERAL SPECIFICATIONS: Isolation ………………………………….……… Input to output = 5,656VDC NOTE: Operating Temperature .......................... -20℃~ 70℃ (see Derating Curve) 1. CFM150M:Add a 0.1uF ceramic capacitor and 10uF E.L. Storage Temperature ……………….…………….........……........ -20 ~ 85℃ Humidity ....................................................... 93% RH max. Non condensing Cooling ……………………………………………………. Natural Convection Switching Frequency ………………………............................ 90KHz Typical. capacitor to output for Ripple & Noise measuring @20MHz BW. 2. Line regulation is measured from High Line to Low Line with full load. 3. Load regulation is measured from Full to 10% load. 4. Connectors: AC input: Molex 5277 or equivalent DC output: Molex 5273 or equivalent 5. DC output pin 1, 2, 3, 4: Vout (-), DC output pin 5, 6, 7, 8: Vout (+) MTBF ………….… MIL-HDBK-217F, GB, 25℃/115VAC …… 100K hrs min. Altitude ……………………..………………...………………………….. 3000m Dimensions ………….. 5.000x3.000x1.050inches (127.00x76.20x26.67mm) Weight ………………………………………………………... 270g (0.6Pounds) SAFETY AND EMC: Emission and Immunity …….… EN55011 Class B, FCC Part 15 Class B EN60601-1-2, EN61000-3-2 Class A, B, C, D, EN61000-3-3 Safety ………………..……..IEC60601-1, EN60601-1, UL60601-1 CFM150M Series All Dimensions are in inches[mm] Tolerances: Inches:x.xxx=±0.02 Millimeters:x.xx=±0.5 5.000[127.00] 0.224[5.70] 4.546[115.48] Typical at 25˚C, nominal line and 75% load, unless otherwise Specified 2