45W Dual Outputs Open Frame Medical Power Supply MP45 series Features: Universal AC input / Full range Medical safety approval: ANSI / AAMI ES 60601-1 / TUV EN 60601-1: 2006; IEC 60601-1 / 2xMOPP Protection: Short circuit, Over load, Over voltage Brown-out (Low AC Input Voltage) High operation temperature up to 70°C Withstand 2G vibration test 3 years warranty MEDICAL Model Output Input Output Number DC Voltage Range Rated Current Current Range Rated Power Peak Load (10sec.) Ripple & Noise (Max.) Voltage Tolerance Line Regulation Load Regulation Setup,Rise Time Hold Up Time Voltage Range Frequency Range Efficiency (Typ.) at 230VAC AC Current (Typ.) Inrush Current (Typ.) Leakage Current Over Load Protection Over Voltage Environment Safety & EMC Others Note Working Temp. Working Humidity Storage Temp. & Humidity Temp. Coefficient Vibration MP45-05F E324816 MP45-05K CH1 CH2 CH1 CH2 5V 5V 12V 24V 3.5A 1.6A 4.2A 1.1A 0.5 ~ 3.85A 0.5 ~ 4.7A 0.1 ~ 1.76A 0.1 ~ 1.21A 43.9W 40.2W 44.62W 48.29W 80mVp-p 80mVp-p 80mVp-p 100mVp-p +3 / -2% +3 / -2% +8 / -4% ±6.0% ±0.5% ±1.0% ±0.5% ±1.0% ±1.5% ±2.0% ±1.5% ±2.0% 200ms,15ms / 230VAC, 200ms,15ms / 115VAC at full load 70ms / 230VAC, 14ms / 115VAC at full load 90 ~ 264VAC, 127 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) 47 ~ 63Hz 80% 82% 1.3A / 115VAC, 0.7A / 230VAC Cold Start 30A / 115VAC, 60A / 230VAC For earth < 200uA/264VAC, For patient < 100uA / 264VAC Above 110% rated output power Protection type: Hiccup mode, recovers automatically after fault condition is removed 115 ~ 140% rated output voltage Protection type: latch-off mode -20 ~ 70°C (Refer to de-rating curve) 20 ~ 90% RH non-condensing -40 ~ +85°C, 10 ~ 95% RH ±0.03% / °C (0 ~ 50°C) 10 ~ 500Hz, 2G 10min. / 1cycle, period for 60min. each along X, Y, Z axes Certified UL / cUL (ANSI / AAMI ES 60601-1; CAN / CSA-C22.2 No.60601-1); NFPA 99 Safety Standards Certified TUV (EN 60601-1; IEC 60601-1); MOPP approval I/P-O/P: 4KVAC, I/P-FG: 1.8KVAC, O/P-FG: 1.5KVAC Withstand Voltage Isolation Resistance I/P-O/P: 100M Ohms / 500VDC EMI Conduction & Radiation Certified EN 55011 Harmonic Current Certified EN 61000-3-2; EN 61000-3-3 Certified EN 60601-1-2; IEC 61000-4-2, 3, 4, 5, 6, 8, 11 EMS Immunity MTBF 215.48K HRS Certified MIL-HDBK-217F Dimension (WxHxD) 50.8x29.0x101.6 mm / 2.000x1.142x4.000 inch Packing 0.151kg; 80pcs / 13.08kg / 1.43CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor. 3. Tolerance: includes setup time tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 7. Length of setup time is measured at first cold start. Turning ON/OFF the power supply continuously may increase the setup time. 8. Max. 33% duty cycle within every 30 sec. Average output power should not exceed the rated power. REV. B0 14/04/23 1 45W Dual Outputs Open Frame Medical Power Supply MP45 series Mechanical Drawings: Unit : mm[inch] 1 2 3 4 5 6 50.8 [2.000] CN1 3 2 1 44.45 [1.75] 3.175 [0.125] CN2 3.175 [0.125] 95.25 [3.75] 4-Φ3.3 29 [1.142] 101.6 [4.000] 3 [0.118] max. AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. 1 2 3 Assignment Mating Housing AC / N No Pin AC / L JST VHR or equivalent DC Output Connector (CN2) : JST B4P-VH or equivalent Terminal Pin No. 1,2 3,4 5 6 JST SVH-21T-P1.1 or equivalent Assignment Mating Housing Terminal V1 COM V2 NC JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Block Diagram: RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING RECTIFIERS & FILTER V2 RECTIFIERS & FILTER V1 COM DETECTION CIRCUIT O.L.P. FG CONTROL O.V.P. De-rating Curve: Load V.S Temp. Load V.S I/P Voltage Ta=25°C 100 100 90 Load (%) Load (%) 80 60 50 80 70 60 40 50 20 -20 40 0 10 20 30 40 50 Ambient Temperature (°C) 60 70 (HORIZONTAL) 90 95 105 115 120 140 160 180 264Vac Input Voltage(VAC) 60Hz REV. B0 14/04/23 2