RHOMBUS-IND T

*T3 INTERFACE TRANSFORMER
Turns Ratio ( + 3% )
1:4CT
PARAMETER
MIN.
Inductance
19
MAX.
UNITS
µHy
Rise Time
3.00
nS
Leakage Inductance
0.35
µHy
Capacitance (CW/W)
15
pF
Primary DC Resistance
0.2
ohms
Isolation
1500
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
Parts shipped in anti-static
tubes. 55 pieces per tube
VRMS
3 dB Bandwidth is .200 - 340 (MHz) typical, tested in a 75 ohm system
* Also suitable for DS3, E3 and STS-1 interfaces
PHYSICAL DIMENSIONS All dimensions in inches (mm):
SCHEMATIC DIAGRAM:
RHOMBUS INDUSTRIES INC.
FSCM NO. 16714
RHOMBUS P/N: T-13106
CUST P/N:
NAME:
DATE: 10/22/96
SHEET:
Rhombus
Industries Inc.
Transformers & Magnetic Products
1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971
www.rhombus-ind.com