RHOMBUS-IND T

T1/CEPT/ISDN PRI INTERFACE TRANSFORMER
Electrical Specifications @ 250C
Turns Ratio ( + 5% )
1 : 2.3CT & 1CT : 1CT
PARAMETER
MIN.
OCL (Primary)
1.2
MAX.
UNITS
mH
Leakage Inductance
0.8 & 0.8
µH
Capacitance (CW/W)
50
pF
Primary DC Resistance
0.8
ohms
Secondary DC Resistance
1.8/0.8
ohms
ET Product
10
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
Parts shipped in anti-static
tubes. 33 pieces per tube
Tape & Reel
Available
VµS
Primary Pins 14-16 & 6-8
Isolation 2000 VRMS Min.
PHYSICAL DIMENSIONS
inches (mm)
SCHEMATIC DIAGRAM:
PRI
16
15
SEC
14
13
12
11
10
9
Rhombus P/N:
1
2
3
4
5
6
SEC
7
PRI
Rhombus
Industries Inc.
Transformers & Magnetic Products
8
Cust. P/N:
Date:
5/16/01
T-14189
Name:
Sheet:
1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971
www.rhombus-ind.com