60CPU06-F Vishay High Power Products Ultrafast Rectifier, FRED PtTM, 2 x 30 A FEATURES • Ultrafast recovery time Base 2 common cathode • Low forward voltage drop • Low leakage current • 175 °C operating junction temperature • Fully lead (Pb)-free and RoHS compliant devices Anode 1 TO-247AC • Designed and qualified for industrial level Anode 2 2 1 Common 3 cathode DESCRIPTION 60CPU02-F series are the state of the art ultrafast recovery rectifiers designed with optimized performance of forward voltage drop and ultrafast recovery time. The planar structure and the platinum doped life time control guarantee the best overall performance, ruggedness and reliability characteristics. These devices are intended for use in the output rectification stage of SMPS, welding, UPS, dc-to-dc converters as well as freewheeling diodes in low voltage inverters and chopper motor drives. Their extremely optimized stored charge and low recovery current minimize the switching losses and reduce over dissipation in the switching element and snubbers. PRODUCT SUMMARY trr 42 ns IF(AV) 2 x 30 A VR 600 V ABSOLUTE MAXIMUM RATINGS PARAMETER SYMBOL Repetitive peak reverse voltage TEST CONDITIONS VRRM per leg Average rectified forward current per device IF(AV) VALUES UNITS 600 V 30 Rated VR, TC = 137 °C 60 Non-repetitive peak surge current per leg IFSM TJ = 25 °C 300 Peak repetitive forward current per leg IFM Rated VR, square wave, 20 kHz, TC = 137 °C 60 Operating junction and storage temperatures TJ, TStg A - 65 to 175 °C ELECTRICAL SPECIFICATIONS (TJ = 25 °C unless otherwise specified) PARAMETER Breakdown voltage, blocking voltage Forward voltage SYMBOL VBR, VR VF TEST CONDITIONS IR = 100 µA MIN. TYP. MAX. 600 - - - 1.31 1.65 IF = 30 A IF = 30 A, TJ = 150 °C - 1.1 1.4 VR = VR rated - 0.02 50 TJ = 150 °C, VR = VR rated - 30 250 UNITS V µA Reverse leakage current IR Junction capacitance CT VR = 200 V - 22 - pF Series inductance LS Measured lead to lead 5 mm from package body - 3.5 - nH Document Number: 94658 Revision: 21-Jan-09 For technical questions, contact: [email protected] www.vishay.com 1 60CPU06-F Vishay High Power Products Ultrafast Rectifier, FRED PtTM, 2 x 30 A DYNAMIC RECOVERY CHARACTERISTICS (TJ = 25 °C unless otherwise specified) PARAMETER Reverse recovery time SYMBOL trr TEST CONDITIONS MIN. TYP. MAX. IF = 1.0 A, dIF/dt = 100 A/µs, VR = 30 V TJ = 25 °C - 27 35 - 42 - - 110 - - 5 - - 11 - TJ = 25 °C - 110 - TJ = 125 °C - 630 - TJ = 125 °C Peak recovery current Reverse recovery charge IRRM Qrr TJ = 25 °C TJ = 125 °C IF = 30 A dIF/dt = - 200 A/µs VR = 200 V UNITS ns A nC THERMAL - MECHANICAL SPECIFICATIONS (TJ = 25 °C unless otherwise noted) PARAMETER MIN. TYP. MAX. UNITS TJ, TStg - 65 - 175 °C Thermal resistance, junction to case per leg RthJC - 0.6 0.9 Thermal resistance, junction to ambient per leg RthJA Typical socket mount - - 70 Thermal resistance, case to heatsink RthCS Mounting surface, flat, smooth and greased - 0.4 - - 6.0 - g - 0.22 - oz. 6.0 (5.0) - 12 (10) kgf · cm (lbf · in) Maximum junction and storage temperature range SYMBOL TEST CONDITIONS Weight Mounting torque Marking device www.vishay.com 2 Case style TO-247AC For technical questions, contact: [email protected] °C/W 60CPU06 Document Number: 94658 Revision: 21-Jan-09 60CPU06-F Ultrafast Rectifier, FRED PtTM, 2 x 30 A 1000 100 TJ = 175 °C TJ = 125 °C TJ = 25 °C 10 1 0.0 TJ = 175 °C 100 IR - Reverse Current (µA) IF - Instantaneous Forward Current (A) 1000 Vishay High Power Products TJ = 150 °C TJ = 125 °C 10 TJ = 100 °C 1 TJ = 75 °C 0.1 TJ = 50 °C 0.01 TJ = 25 °C 0.001 0.5 1.0 1.5 2.0 2.5 0 100 200 300 400 500 600 VF - Forward Voltage Drop (V) VR - Reverse Voltage (V) Fig. 1 - Typical Forward Voltage Drop Characteristics Fig. 2 - Typical Values of Reverse Current vs. Reverse Voltage CT - Junction Capacitance (pF) 1000 100 10 0 100 200 300 400 500 600 VR - Reverse Voltage (V) ZthJC - Thermal Impedance (°C/W) Fig. 3 - Typical Junction Capacitance vs. Reverse Voltage 10 1 0.1 0.01 Single pulse (thermal resistance) 0.001 0.00001 0.0001 D = 0.50 D = 0.20 D = 0.10 D = 0.05 D = 0.02 D = 0.01 . 0.001 0.01 0.1 1 t1 - Rectangular Pulse Duration (s) Fig. 4 - Maximum Thermal Impedance ZthJC Characteristics Document Number: 94658 Revision: 21-Jan-09 For technical questions, contact: [email protected] www.vishay.com 3 60CPU06-F Ultrafast Rectifier, FRED PtTM, 2 x 30 A Vishay High Power Products 1000 160 DC trr (ns) Allowable Case Temperature (°C) 180 140 Square wave (D = 0.50) Rated VR applied IF = 30 A, TJ = 25 °C 120 See note (1) 100 0 5 10 15 20 25 30 35 40 10 100 45 1000 IF(AV) - Average Forward Current (A) dIF/dt (A/µs) Fig. 5 - Maximum Allowable Case Temperature vs. Average Forward Current Fig. 7 - Typical Reverse Recovery Time vs. dIF/dt 60 10 000 50 40 1000 RMS limit D = 0.01 30 D = 0.02 D = 0.05 D = 0.10 D = 0.20 D = 0.50 20 DC 10 100 0 0 10 20 30 40 IF = 30 A, TJ = 125 °C Qrr (nC) Average Power Loss (W) IF = 30 A, TJ = 125 °C 100 50 IF = 30 A, TJ = 25 °C 10 100 1000 IF(AV) - Average Forward Current (A) dIF/dt (A/µs) Fig. 6 - Forward Power Loss Characteristics Fig. 8 - Typical Stored Charge vs. dIF/dt Note Formula used: TC = TJ - (Pd +PdREV) x RthJC; Pd = Forward power loss = IF(AV) x VFM at (IF(AV)/D) (see fig. 6); PdREV = Inverse power loss = VR1 x IR (1 - D); IR at VR1 = Rated VR (1) www.vishay.com 4 For technical questions, contact: [email protected] Document Number: 94658 Revision: 21-Jan-09 60CPU06-F Ultrafast Rectifier, FRED PtTM, 2 x 30 A Vishay High Power Products VR = 200 V 0.01 Ω L = 70 µH D.U.T. dIF/dt adjust D IRFP250 G S Fig. 9 - Reverse Recovery Parameter Test Circuit (3) trr IF ta tb 0 Qrr (2) IRRM (4) 0.5 IRRM dI(rec)M/dt (5) 0.75 IRRM (1) dIF/dt (1) dIF/dt - rate of change of current through zero crossing (2) IRRM - peak reverse recovery current (3) trr - reverse recovery time measured from zero crossing point of negative going IF to point where a line passing through 0.75 IRRM and 0.50 IRRM extrapolated to zero current. (4) Qrr - area under curve defined by trr and IRRM Qrr = trr x IRRM 2 (5) dI(rec)M/dt - peak rate of change of current during tb portion of trr Fig. 10 - Reverse Recovery Waveform and Definitions Document Number: 94658 Revision: 21-Jan-09 For technical questions, contact: [email protected] www.vishay.com 5 60CPU06-F Ultrafast Rectifier, FRED PtTM, 2 x 30 A Vishay High Power Products ORDERING INFORMATION TABLE Device code 60 C P U 06 1 2 3 4 5 1 - Current rating (60 = 60 A) 2 - Circuit configuration: - F 6 C = Common cathode 3 - Package: 4 - U = Ultrafast rectifier 5 - Voltage rating (06 = 600 V) 6 - RoHS compliant and totally lead (Pb)-free P = TO-247AC (modified) Tube standard pack quantity: 25 pieces LINKS TO RELATED DOCUMENTS Dimensions http://www.vishay.com/doc?95223 Part marking information http://www.vishay.com/doc?95007 www.vishay.com 6 For technical questions, contact: [email protected] Document Number: 94658 Revision: 21-Jan-09 Outline Dimensions www.vishay.com Vishay Semiconductors DIMENSIONS in millimeters and inches A A (3) (6) Ø P E B (2) R/2 N A2 S (Datum B) Ø K M DBM FP1 A D2 Q 2xR (2) D1 (4) D 1 4 D 3 2 Thermal pad (5) L1 C L A See view B 2 x b2 3xb 0.10 M C A M Planting (4) E1 0.01 M D B M View A - A C 2x e A1 b4 (b1, b3, b5) Lead assignments Base metal D DE (c) c1 E C C Diodes 1. - Anode/open 2. - Cathode 3. - Anode (b, b2, b4) (4) Section C - C, D - D, E - E SYMBOL A A1 A2 b b1 b2 b3 b4 b5 c c1 D D1 MILLIMETERS MIN. MAX. 4.65 5.31 2.21 2.59 1.50 2.49 0.99 1.40 0.99 1.35 1.65 2.39 1.65 2.37 2.59 3.43 2.59 3.38 0.38 0.86 0.38 0.76 19.71 20.70 13.08 - INCHES MIN. MAX. 0.183 0.209 0.087 0.102 0.059 0.098 0.039 0.055 0.039 0.053 0.065 0.094 0.065 0.094 0.102 0.135 0.102 0.133 0.015 0.034 0.015 0.030 0.776 0.815 0.515 - View B NOTES SYMBOL 3 4 D2 E E1 e FK L L1 N P P1 Q R S MILLIMETERS MIN. MAX. 0.51 1.30 15.29 15.87 13.72 5.46 BSC 2.54 14.20 16.10 3.71 4.29 7.62 BSC 3.56 3.66 6.98 5.31 5.69 4.52 5.49 5.51 BSC INCHES MIN. MAX. 0.020 0.051 0.602 0.625 0.540 0.215 BSC 0.010 0.559 0.634 0.146 0.169 0.3 0.14 0.144 0.275 0.209 0.224 1.78 0.216 0.217 BSC NOTES 3 Notes (1) Dimensioning and tolerancing per ASME Y14.5M-1994 (2) Contour of slot optional (3) Dimension D and E do not include mold flash. Mold flash shall not exceed 0.127 mm (0.005") per side. These dimensions are measured at the outermost extremes of the plastic body (4) Thermal pad contour optional with dimensions D1 and E1 (5) Lead finish uncontrolled in L1 (6) Ø P to have a maximum draft angle of 1.5 to the top of the part with a maximum hole diameter of 3.91 mm (0.154") (7) Outline conforms to JEDEC outline TO-247 with exception of dimension c Revision: 16-Jun-11 Document Number: 95223 1 For technical questions within your region: [email protected], [email protected], [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Legal Disclaimer Notice Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Document Number: 91000 Revision: 11-Mar-11 www.vishay.com 1