VISHAY 60CPU06-F

60CPU06-F
Vishay High Power Products
Ultrafast Rectifier,
FRED PtTM, 2 x 30 A
FEATURES
• Ultrafast recovery time
Base 2
common
cathode
• Low forward voltage drop
• Low leakage current
• 175 °C operating junction temperature
• Fully lead (Pb)-free and RoHS compliant devices
Anode 1
TO-247AC
• Designed and qualified for industrial level
Anode 2
2
1 Common 3
cathode
DESCRIPTION
60CPU02-F series are the state of the art ultrafast recovery
rectifiers designed with optimized performance of forward
voltage drop and ultrafast recovery time.
The planar structure and the platinum doped life time control
guarantee the best overall performance, ruggedness and
reliability characteristics.
These devices are intended for use in the output rectification
stage of SMPS, welding, UPS, dc-to-dc converters as well as
freewheeling diodes in low voltage inverters and chopper
motor drives.
Their extremely optimized stored charge and low recovery
current minimize the switching losses and reduce over
dissipation in the switching element and snubbers.
PRODUCT SUMMARY
trr
42 ns
IF(AV)
2 x 30 A
VR
600 V
ABSOLUTE MAXIMUM RATINGS
PARAMETER
SYMBOL
Repetitive peak reverse voltage
TEST CONDITIONS
VRRM
per leg
Average rectified forward current
per device
IF(AV)
VALUES
UNITS
600
V
30
Rated VR, TC = 137 °C
60
Non-repetitive peak surge current per leg
IFSM
TJ = 25 °C
300
Peak repetitive forward current per leg
IFM
Rated VR, square wave, 20 kHz, TC = 137 °C
60
Operating junction and storage temperatures
TJ, TStg
A
- 65 to 175
°C
ELECTRICAL SPECIFICATIONS (TJ = 25 °C unless otherwise specified)
PARAMETER
Breakdown voltage,
blocking voltage
Forward voltage
SYMBOL
VBR,
VR
VF
TEST CONDITIONS
IR = 100 µA
MIN.
TYP.
MAX.
600
-
-
-
1.31
1.65
IF = 30 A
IF = 30 A, TJ = 150 °C
-
1.1
1.4
VR = VR rated
-
0.02
50
TJ = 150 °C, VR = VR rated
-
30
250
UNITS
V
µA
Reverse leakage current
IR
Junction capacitance
CT
VR = 200 V
-
22
-
pF
Series inductance
LS
Measured lead to lead 5 mm from package body
-
3.5
-
nH
Document Number: 94658
Revision: 21-Jan-09
For technical questions, contact: [email protected]
www.vishay.com
1
60CPU06-F
Vishay High Power Products
Ultrafast Rectifier,
FRED PtTM, 2 x 30 A
DYNAMIC RECOVERY CHARACTERISTICS (TJ = 25 °C unless otherwise specified)
PARAMETER
Reverse recovery time
SYMBOL
trr
TEST CONDITIONS
MIN.
TYP.
MAX.
IF = 1.0 A, dIF/dt = 100 A/µs, VR = 30 V
TJ = 25 °C
-
27
35
-
42
-
-
110
-
-
5
-
-
11
-
TJ = 25 °C
-
110
-
TJ = 125 °C
-
630
-
TJ = 125 °C
Peak recovery current
Reverse recovery charge
IRRM
Qrr
TJ = 25 °C
TJ = 125 °C
IF = 30 A
dIF/dt = - 200 A/µs
VR = 200 V
UNITS
ns
A
nC
THERMAL - MECHANICAL SPECIFICATIONS (TJ = 25 °C unless otherwise noted)
PARAMETER
MIN.
TYP.
MAX.
UNITS
TJ, TStg
- 65
-
175
°C
Thermal resistance,
junction to case per leg
RthJC
-
0.6
0.9
Thermal resistance,
junction to ambient per leg
RthJA
Typical socket mount
-
-
70
Thermal resistance,
case to heatsink
RthCS
Mounting surface, flat, smooth
and greased
-
0.4
-
-
6.0
-
g
-
0.22
-
oz.
6.0
(5.0)
-
12
(10)
kgf · cm
(lbf · in)
Maximum junction and
storage temperature range
SYMBOL
TEST CONDITIONS
Weight
Mounting torque
Marking device
www.vishay.com
2
Case style TO-247AC
For technical questions, contact: [email protected]
°C/W
60CPU06
Document Number: 94658
Revision: 21-Jan-09
60CPU06-F
Ultrafast Rectifier,
FRED PtTM, 2 x 30 A
1000
100
TJ = 175 °C
TJ = 125 °C
TJ = 25 °C
10
1
0.0
TJ = 175 °C
100
IR - Reverse Current (µA)
IF - Instantaneous Forward
Current (A)
1000
Vishay High Power Products
TJ = 150 °C
TJ = 125 °C
10
TJ = 100 °C
1
TJ = 75 °C
0.1
TJ = 50 °C
0.01
TJ = 25 °C
0.001
0.5
1.0
1.5
2.0
2.5
0
100
200
300
400
500
600
VF - Forward Voltage Drop (V)
VR - Reverse Voltage (V)
Fig. 1 - Typical Forward Voltage Drop Characteristics
Fig. 2 - Typical Values of Reverse Current vs.
Reverse Voltage
CT - Junction Capacitance (pF)
1000
100
10
0
100
200
300
400
500
600
VR - Reverse Voltage (V)
ZthJC - Thermal Impedance (°C/W)
Fig. 3 - Typical Junction Capacitance vs. Reverse Voltage
10
1
0.1
0.01
Single pulse
(thermal resistance)
0.001
0.00001
0.0001
D = 0.50
D = 0.20
D = 0.10
D = 0.05
D = 0.02
D = 0.01
.
0.001
0.01
0.1
1
t1 - Rectangular Pulse Duration (s)
Fig. 4 - Maximum Thermal Impedance ZthJC Characteristics
Document Number: 94658
Revision: 21-Jan-09
For technical questions, contact: [email protected]
www.vishay.com
3
60CPU06-F
Ultrafast Rectifier,
FRED PtTM, 2 x 30 A
Vishay High Power Products
1000
160
DC
trr (ns)
Allowable Case Temperature (°C)
180
140
Square wave (D = 0.50)
Rated VR applied
IF = 30 A, TJ = 25 °C
120
See note (1)
100
0
5
10
15
20
25
30
35
40
10
100
45
1000
IF(AV) - Average Forward Current (A)
dIF/dt (A/µs)
Fig. 5 - Maximum Allowable Case Temperature vs.
Average Forward Current
Fig. 7 - Typical Reverse Recovery Time vs. dIF/dt
60
10 000
50
40
1000
RMS limit
D = 0.01
30
D = 0.02
D = 0.05
D = 0.10
D = 0.20
D = 0.50
20
DC
10
100
0
0
10
20
30
40
IF = 30 A, TJ = 125 °C
Qrr (nC)
Average Power Loss (W)
IF = 30 A, TJ = 125 °C
100
50
IF = 30 A, TJ = 25 °C
10
100
1000
IF(AV) - Average Forward Current (A)
dIF/dt (A/µs)
Fig. 6 - Forward Power Loss Characteristics
Fig. 8 - Typical Stored Charge vs. dIF/dt
Note
Formula used: TC = TJ - (Pd +PdREV) x RthJC;
Pd = Forward power loss = IF(AV) x VFM at (IF(AV)/D) (see fig. 6);
PdREV = Inverse power loss = VR1 x IR (1 - D); IR at VR1 = Rated VR
(1)
www.vishay.com
4
For technical questions, contact: [email protected]
Document Number: 94658
Revision: 21-Jan-09
60CPU06-F
Ultrafast Rectifier,
FRED PtTM, 2 x 30 A
Vishay High Power Products
VR = 200 V
0.01 Ω
L = 70 µH
D.U.T.
dIF/dt
adjust
D
IRFP250
G
S
Fig. 9 - Reverse Recovery Parameter Test Circuit
(3)
trr
IF
ta
tb
0
Qrr
(2)
IRRM
(4)
0.5 IRRM
dI(rec)M/dt (5)
0.75 IRRM
(1) dIF/dt
(1) dIF/dt - rate of change of current
through zero crossing
(2) IRRM - peak reverse recovery current
(3) trr - reverse recovery time measured
from zero crossing point of negative
going IF to point where a line passing
through 0.75 IRRM and 0.50 IRRM
extrapolated to zero current.
(4) Qrr - area under curve defined by trr
and IRRM
Qrr =
trr x IRRM
2
(5) dI(rec)M/dt - peak rate of change of
current during tb portion of trr
Fig. 10 - Reverse Recovery Waveform and Definitions
Document Number: 94658
Revision: 21-Jan-09
For technical questions, contact: [email protected]
www.vishay.com
5
60CPU06-F
Ultrafast Rectifier,
FRED PtTM, 2 x 30 A
Vishay High Power Products
ORDERING INFORMATION TABLE
Device code
60
C
P
U
06
1
2
3
4
5
1
-
Current rating (60 = 60 A)
2
-
Circuit configuration:
-
F
6
C = Common cathode
3
-
Package:
4
-
U = Ultrafast rectifier
5
-
Voltage rating (06 = 600 V)
6
-
RoHS compliant and totally lead (Pb)-free
P = TO-247AC (modified)
Tube standard pack quantity: 25 pieces
LINKS TO RELATED DOCUMENTS
Dimensions
http://www.vishay.com/doc?95223
Part marking information
http://www.vishay.com/doc?95007
www.vishay.com
6
For technical questions, contact: [email protected]
Document Number: 94658
Revision: 21-Jan-09
Outline Dimensions
www.vishay.com
Vishay Semiconductors
DIMENSIONS in millimeters and inches
A
A
(3)
(6) Ø P
E
B
(2) R/2
N
A2
S
(Datum B)
Ø K M DBM
FP1
A
D2
Q
2xR
(2)
D1 (4)
D
1
4
D
3
2
Thermal pad
(5) L1
C
L
A
See view B
2 x b2
3xb
0.10 M C A M
Planting
(4)
E1
0.01 M D B M
View A - A
C
2x e
A1
b4
(b1, b3, b5)
Lead assignments
Base metal
D DE
(c)
c1
E
C
C
Diodes
1. - Anode/open
2. - Cathode
3. - Anode
(b, b2, b4)
(4)
Section C - C, D - D, E - E
SYMBOL
A
A1
A2
b
b1
b2
b3
b4
b5
c
c1
D
D1
MILLIMETERS
MIN.
MAX.
4.65
5.31
2.21
2.59
1.50
2.49
0.99
1.40
0.99
1.35
1.65
2.39
1.65
2.37
2.59
3.43
2.59
3.38
0.38
0.86
0.38
0.76
19.71
20.70
13.08
-
INCHES
MIN.
MAX.
0.183
0.209
0.087
0.102
0.059
0.098
0.039
0.055
0.039
0.053
0.065
0.094
0.065
0.094
0.102
0.135
0.102
0.133
0.015
0.034
0.015
0.030
0.776
0.815
0.515
-
View B
NOTES
SYMBOL
3
4
D2
E
E1
e
FK
L
L1
N
P
P1
Q
R
S
MILLIMETERS
MIN.
MAX.
0.51
1.30
15.29
15.87
13.72
5.46 BSC
2.54
14.20
16.10
3.71
4.29
7.62 BSC
3.56
3.66
6.98
5.31
5.69
4.52
5.49
5.51 BSC
INCHES
MIN.
MAX.
0.020
0.051
0.602
0.625
0.540
0.215 BSC
0.010
0.559
0.634
0.146
0.169
0.3
0.14
0.144
0.275
0.209
0.224
1.78
0.216
0.217 BSC
NOTES
3
Notes
(1) Dimensioning and tolerancing per ASME Y14.5M-1994
(2) Contour of slot optional
(3) Dimension D and E do not include mold flash. Mold flash shall not exceed 0.127 mm (0.005") per side. These dimensions are measured at
the outermost extremes of the plastic body
(4) Thermal pad contour optional with dimensions D1 and E1
(5) Lead finish uncontrolled in L1
(6) Ø P to have a maximum draft angle of 1.5 to the top of the part with a maximum hole diameter of 3.91 mm (0.154")
(7) Outline conforms to JEDEC outline TO-247 with exception of dimension c
Revision: 16-Jun-11
Document Number: 95223
1
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Legal Disclaimer Notice
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree
to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and
damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay
or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to
obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Document Number: 91000
Revision: 11-Mar-11
www.vishay.com
1