DELTA 03MK2

HIGH PERFORMANCE PC BOARD
SERIES MOUNTING FILTERS
1. Maximum leakage current each
line-to-ground @115VAC 60Hz: 0.2mA
@250VAC 50Hz: 0.4mA
2. Hipot rating (one minute)
line-to-ground: 2250VDC
line-to-line: 1450VDC
3. Operating frequency: 50/60 Hz
4. Rated voltage: 115/250VAC
1. Direct PC board mounting for easy installation.
2. All part numbers are UL recognized, CSA certified and
VDE approved.
3. Optional medical version.
COMPONENTS
Cx (uF)
0.1
L (mH)
10
2.5
Cy (pF)
R
2200
1M
ELECTRICAL SCHEMATIC
L
1
L'
L
I
N
E
MINIMUM INSERTION LOSS IN dB
R
Cy
Cx
L
Cy
L
O
A
D
N
N'
G'
30
20
30
30
25
SERIES DIMENSIONS
PART NO.
DIMENSIONS IN INCHES/mm
A
B
C
0.65
16.5
0.03
0.8
0.04
1.1
0.79
0.047
0.06
20.0
1.2
1.5
01MK4E
20
28
25
35
03MK4E
06MK4E
10MK4E
B
0.4 0.004(2X)
+0
0.18-0.02
+0
4.5-0.5
MECHANICAL CONSTRUCTION
1.3 0.004
33.0 0.1
0.4 0.004
10.2 0.1
A
0.8 0.004
20.3 0.1
C
5-11
1.10
28.0
SUGGESTED MOUNTING PITCH IN P.C. BOARD
0.8 0.02
20.3 0.5
0.4 0.02
10.15 0.5
0.4 0.02
10.2 0.5
1.3 0.02
33.0 0.5
0.15 0.02
3.85 0.5
1.63
41.5
MK4E
10.15 0.1(2X)
COMMON MODE (L-G) IN 50 OHM SYSTEM
CURRENT
FREQUENCY-MHz
TYPE
RATING
.15
.50 1.0
5.0
10
01MK4E
1A
30
50
40
40
35
03MK4E
3A
20
30
45
48
45
06MK4E
6A
15
25
30
45
40
10MK4E
10A
12
20
30
30
35
DIFFERENTIAL MODE (L-L) IN 50 OHM SYSTEM
01MK4E
1A
5
25
40
40
40
03MK4E
3A
5
15
25
35
35
06MK4E
6A
5
12
20
20
30
10MK4E
10A
5
15
20
30
35
UNIT:
INCH
mm
GENERAL PURPOSE ONE-STAGE FILTERS
SPECIFICATIONS
INTRODUCTIONS
PART NO.
01MK4E
03MK4E
06MK4E
10MK4E
V
D E