IB

SERIES
POWER ENTRY MODULE EMI FILTERS
V
D E
SPECIFICATIONS
INTRODUCTIONS
1. Power module incorporates an IEC connector,
single or double-fuse (IEC 5 x 20mm) holder,
and double-pole power switch, plus an EMI
filter all-in-one easy-to-install unit.
2. All part numbers are UL recognized, CSA
certified and VDE approved.
3. Switch electrical lifetime: 10,000 cycles.
Maximum inrush current: 50A.
1. Maximum leakage current each
line-to-ground @ 115VAC 60Hz: 0.2mA
@ 250VAC 50Hz: 0.4mA
2. Hipot rating (one minute)
line-to-ground: 2250VDC
line-to-line: 1450VDC
3. Operating frequency: 50/60Hz
4. Rated voltage: 115/250VAC
COMPONENTS
PART NO.
01IB2D
01IB2S
03IB2D
03IB2S
06IB2D
06IB2S
Cx (uF) L (mH)
Cy(pF)
R(
)
ELECTRICAL SCHEMATIC
7.5
0.22
2.0
2200
1M
X
0.45
MINIMUM INSERTION LOSS IN dB
FIG. A
COMMON MODE (L-G) IN 50 OHM SYSTEM
CURRENT
FREQUENCY-MHz
RATING
0.15
0.50
1.0
5.0
10
30
1A
28
40
40
35
35
25
3A
15
30
35
35
40
25
6A
8
15
20
32
40
25
DIFFERENTIAL MODE (L-G) IN 50 OHM SYSTEM
1A
10
20
28
35
38
35
3A
8
15
20
30
35
35
6A
8
15
15
30
35
35
X
FIG. B
DELTA PART NO.
RATED CURRENT
115VAC
250VAC
IEC CONNECTOR
FUSE
DOUBLE-POLE POWER SWITCH
ELECTRICAL SCHEMATIC
01IB2D
1A
1A
D
03IB2D 06IB2D
3A
6A
3A
6A
D
D
DOUBLE
DOUBLE
FIG. A
01IB2S
1A
1A
D
03IB2S 06IB2S
3A
6A
3A
6A
D
D
SINGLE
DOUBLE
FIG. B
UL, CSA, VDE approved current rating: UL/CSA-10A
both at 125VAC and 250VAC: VDE-4A/250VAC.
M3
R0.1
R2.5
2.57REF.
IB2D
+0.02
2.360
+0.5
60.00
0.57 0.04
14.5 1.0
SUGGESTED MOUNTING CUTOUT
2.2MAX.
56.0MAX.
2.34MAX.
59.5MAX.
4-15
+0.02
1.16-0
+0.5
29.0-0
1.575 0.02
40.0 0.5
2.0MAX.
50.7MAX.
2.6MAX.
66.0MAX.
0.13(2X)
3.3(2X)
1.575 0.004
40.0 0.1
65.7REF.
MECHANICAL CONSTRUCTION
UNIT: INCH
mm
POWER ENTRY MODULE FILTERS
TYPE & RATED CURRENT