Product Data Sheet Part Number: C3126 Revision Level: 0 2C 14 19/.0147 BC FLEX PVDF Date: TYPE CL2P A. CONSTRUCTION Conductor: Insulation: Cable: Jacket: Print Legend: DIAMETERS #14 AWG 19/.0147 Bare Copper 0.070” nom. 0.010" Wall FLEXGUARD* 0.090" nom. 2 Conductors @ 4.00" LHL. 0.148" nom. 0.010"Wall PVDF – Natural 0.168" +/- 0.008" -Plenum ripcord under jacket. CAROL (R) - - 14 AWG - - 60C E63869-S CL2P (UL) - - MADE IN USA DATE CODE (PRINT EVERY 2 FT) B. INDUSTRY APPROVALS National Electrical Code UL Standard 13 Article 725 Type CL2P C. ELECTRICAL PROPERTIES TEMPERATURE: SUGGESTED WORKING VOLTAGE (Vrms): CONDUCTOR D.C. RESISTANCE: D. COLOR CODE 1 2 60C 150 Vrms (CL2P) 2.6 Ohms/1000 ft. nom. @ 20C (Listed as Individual Conductors or Pairs of Conductors) Black White Note: Data are subject to change without notice. Contact your Customer Service representative for latest information. *FLEXGUARD is a trademark of General Cable Corporation for polymer alloy insulation and jackets. 7/7/2007