ETC 9841

9841 Paired - Low Capacitance EIA RS-485
For more information please
call
1-800-Belden1
See Put-ups and Colors
Color Code Chart : No. 5 for
Paired Cables (Western
Electric Standard).pdf
Description:
24 AWG stranded (7x32) tinned copper conductors, twisted pair, polyethylene insulated, overall 100% Beldfoil® shield plus a 90% tinned
copper braid shield, 24 AWG (7x32) tinned copper drain wire, PVC jacket.
PHYSICAL CHARACTERISTICS:
CONDUCTOR:
Number of Pairs
1
Total Number of Conductors
2
AWG
24
Stranding
7x32
Conductor Material
TC - Tinned Copper
INSULATION:
Insulation Material
PE - Polyethylene
PAIR:
Pair Lay Length :
Lay Length (in.)
2.5
Direction
Left Hand Lay
Twists/ft (twist/ft)
4.8
Pair Twists/ft.
4.8
Pair Color Code Chart
White/Blue and Blue/White
OUTER SHIELD:
Outer Shield Material Trade Name
Beldfoil®
Outer Shield Type
Tape/Braid
Outer Shield Material :
Layer Number
1
Material Trade Name
Beldfoil®
2
Type
Tape
Material
Aluminum Foil-Polyester
Tape
Tinned Copper Braid
Shield
Braid
OUTER SHIELD DRAIN WIRE :
Outer Shield Drain Wire AWG
24
Page 1 of 3
% Coverage (%)
100
90
9841 Paired - Low Capacitance EIA RS-485
Outer Shield Drain Wire Stranding
7x32
Outer Shield Drain Wire Conductor Material
TC - Tinned Copper
OUTER JACKET:
Outer Jacket Material
PVC - Polyvinyl Chloride
OVERALL NOMINAL DIAMETER:
Overall Nominal Diameter
.232 in.
MECHANICAL CHARACTERISTICS:
Operating Temperature Range
-30°C To +80°C
UL Temperature Rating
80°C
Bulk Cable Weight
36 lbs/1000 ft.
Max. Recommended Pulling Tension
72.3 lbs.
Min. Bend Radius (Install)
2.5 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE:
APPLICABLE STANDARDS:
NEC/(UL) Specification
CM
CEC/C(UL) Specification
CM
AWM Specification
2919 (30 V)
PLENUM/NON-PLENUM:
Plenum (Y/N)
N
Plenum Number
82841, 89841
ELECTRICAL CHARACTERISTICS:
Nom. Characteristic Impedance
120 Ohms
Nom. Capacitance Conductor to Conductor @ 1 KHz
12.8 pF/ft
Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz
23 pF/ft
Nominal Velocity of Propagation
66 %
Nominal Delay
1.6 ns/ft
Nom. Conductor DC Resistance @ 20 Deg. C
24 Ohms/1000 ft
Nominal Outer Shield DC Resistance @ 20 Deg. C
3.4 Ohms/1000 ft
Nom. Attenuation (dB/100 ft)
0.6 (@ 1 MHz) dB/100 ft.
Max. Operating Voltage - UL
300 V RMS
Other Maximum Continuous Currents
2.1 Amps per conductor @ 25°C
PUT-UPS AND COLORS:
Item
Description
Put-Up (ft.)
9841 060100
1 PR #24 PE SH PVC 100
Ship Weight (lbs.)
4.3
Jacket Color
CHROME
Notes
9841 0601000
40
CHROME
C
1 PR #24 PE SH PVC 1000
Page 2 of 3
9841 Paired - Low Capacitance EIA RS-485
9841 060500
1 PR #24 PE SH PVC 500
20
CHROME
C = CRATE REEL PUT-UP.
Revision Number: 1
Revision Date: 11-13-2003
© 2003 Belden Wire & Cable Company
All Rights Reserved.
Although Belden Electronics Division ("Belden") makes every reasonable effort to ensure their accuracy at the time of this publication,
information and specifications described herein are subject to error or omission and to change without notice, and the listing of such
information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described
herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Page 3 of 3