ETC 1590AD151000

1590A Paired - Category 5e Unbonded-Pair Cable
For more information please
call
1-800-Belden1
See Put-ups and Colors
Related Documents : No. 8 for
DataTwist Cables (Modified
Western Electric).pdf
Description:
24 AWG solid bare copper conductors, plenum, FEP Teflon® insulation, twisted pairs, rip cord, see color code chart (below), Flamarrest®
jacket (natural or blue).
SUITABLE APPLICATIONS:
Suitable Applications
Premise Horizontal Cable, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN,
155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU,
Digital Video, RS-422
PHYSICAL CHARACTERISTICS:
CONDUCTOR:
Number of Pairs
2
Total Number of Conductors
4
AWG
24
Stranding
Solid
Conductor Material
BC - Bare Copper
INSULATION:
Insulation Material
FEP - Fluorinated Ethylene Propylene
Pair Color Code Chart :
Number
1
Color
White/Blue Stripe & Blue
Number
2
OUTER SHIELD:
Outer Shield Material
Unshielded
OUTER JACKET:
Outer Jacket Material Trade Name
Flamarrest®
Outer Jacket Material
LS PVC - Low Smoke Polyvinyl Chloride
Outer Jacket Ripcord
Yes
OVERALL NOMINAL DIAMETER:
Overall Nominal Diameter
.165 in.
Page 1 of 4
Color
White/Orange Stripe & Orange
1590A Paired - Category 5e Unbonded-Pair Cable
MECHANICAL CHARACTERISTICS:
Operating Temperature Range
-20°C To +75°C
Bulk Cable Weight
21 lbs/1000 ft.
Max. Recommended Pulling Tension
13 lbs.
Min. Bend Radius (Install)
0.7 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE:
APPLICABLE STANDARDS:
NEC/(UL) Specification
CMP, UL444
CEC/C(UL) Specification
CMP
EU CE Mark (Y/N)
Yes
EU RoHS Compliant (Y/N)
Yes
EU RoHS Compliance Date (mm/dd/yyyy):
01/01/2005
TIA/EIA Specification
568-B.2 Category 5e
Other Specification
NEMA WC-63.1 Category 5e, UL verified to Category 5e
FLAME TEST:
UL Flame Test
NFPA 262
CSA Flame Test
FT4, FT6
PLENUM/NON-PLENUM:
Plenum (Y/N)
Y
Non-Plenum Number
1588A, 1588R
ELECTRICAL CHARACTERISTICS:
Nom. Mutual Capacitance @ 1 KHz
14 pF/ft
Maximum Capacitance Unbalance (pF/100 m)
330 pF/100 m
Nominal Velocity of Propagation
72 %
Maximum Delay (ns/100 m)
538 @ 100MHz ns/100 m
Maximum Delay Skew (ns/100m)
45 ns/100 m
Maximum Conductor DC Resistance @ 20 Deg. C
9.38 Ohms/100 m
Maximum DCR Unbalance @ 20 Deg. C
5%
Max. Operating Voltage - UL
300 V RMS
ELECTRICAL CHARACTERISTICS - PREMISE:
Premise Cable Electricals Table 1 :
Page 2 of 4
1590A Paired - Category 5e Unbonded-Pair Cable
Frequency
(MHz)
Max.
Attenuation
(dB/100 m)
Min. NEXT
(dB)
Min. PSNEXT Min. ACR (dB) Min. PSACR
(dB)
(dB)
Min. Return
Loss (dB)
1
4
8
10
16
20
25
31.25
62.5
100
155
200
2.0
4.1
5.8
6.5
8.2
9.3
10.4
11.7
17.0
22.0
28.1
32.0
65.3
56.3
51.8
50.3
47.3
45.8
44.3
42.9
38.4
35.3
32.5
30.8
62.3
53.3
48.8
47.3
44.3
42.8
41.3
39.9
35.4
32.3
29.5
27.8
20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1
15.8
15.0
63.0
51.0
46.0
43.0
39.0
36.5
33.9
31.0
22.0
14.0
4.4
4.0
60.3
49.2
43.0
40.8
36.0
33.5
30.9
28.2
19.0
10.3
1.4
1.0
Min.
Structural
Return Loss
(dB)
23.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1
Premise Cable Electricals Table 2 :
Frequency (MHz)
1
4
8
10
16
20
25
31.25
62.5
100
155
200
Input (Unfitted)
Impedance (Ohms)
100 ± 15
100 ± 15
100 ± 15
100 ± 15
100 ± 15
100 ± 15
100 ± 15
100 ± 15
100 ± 15
100 ± 15
100 ± 25
100 ± 25
Fitted Impedance
(Ohms)
100 ± 15
100 ± 15
100 ± 15
100 ± 15
100 ± 15
100 ± 15
100 ± 15
100 ± 15
100 ± 15
100 ± 15
100 ± 15
100 ± 15
Min. ELFEXT (dB)
Min. PSELFEXT (dB)
63.8
51.7
45.7
43.8
39.7
37.7
35.8
33.9
27.8
23.8
19.9
17.7
60.8
48.7
42.7
40.8
36.7
34.7
32.8
30.9
24.9
20.8
16.9
14.7
NOTES:
Notes
Jacket sequentially marked at 2 ft. intervals. Third party verified to TIA/EIA-568B.2, Category 5e.
PUT-UPS AND COLORS:
Item
Description
1590A 8771000
2 PR #24 FEP
FLMRST
1590A D151000
2 PR #24 FEP
FLMRST
Put-Up (ft.)
1000
Ship Weight (lbs.)
16
Jacket Color
NATURAL
1000
16
BLUE
C = CRATE REEL PUT-UP.
Revision Number: 2
Revision Date: 04-18-2006
Page 3 of 4
Notes
C
1590A Paired - Category 5e Unbonded-Pair Cable
© Copyright 2006 Belden, Inc
All Rights Reserved.
Although Belden ("Belden") makes every reasonable effort to ensure their accuracy at the time of this publication, information and
specifications described herein are subject to error or omission and to change without notice, and the listing of such information and
specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described
herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with the following environmental regulations: California Proposition 65 Consent Judgment
For Wire & Cable Mfgs.(San Francisco Superior Court Nos. 312962 And 320342); EU RoHS (Directive 2002/95/EC, 27-Jan2003);Material manufactured prior to the compliance date may still be in stock at Belden facilities and in our Distributor's inventory. EU
ELV (Directive 2000/53/EC, 18-Sept-2000); EU WEEE (Directive 2002/96/EC, 27-Jan-2003); And EU BFR (Directive 2003/11/EC, 6-Feb2003). The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the
Product Disclosure, is correct to the best of Belden's knowledge, information and belief at the date of its publication. The information
provided in the Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product
itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory
information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations
based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.