ROITHNER ADL

ADL-63302TL
TECHNICAL DATA
Red Laser Diode
Features
•
•
•
•
•
AlGaAlP laser diode
Peak Wavelength: 638 nm
Single Transverse/Longitudinal Mode
Optical Ouput Power: 30 mW
Package: 5.6 mm, with Photo Diode
Electrical Connection
Pin Configuration
Bottom View
m-type
PIN
1
2
3
Function
LD Cathode
LD Anode, PD Cathode
PD Anode
Absolute Maximum Ratings (TC=25°C)
Item
Optical Output Power
LD Reverse Voltage
PD Reverse Voltage
PD Forward Current
Operating Case Temperature
Storage Temperature
Symbol
PO
VR (LD)
VR (PD)
IPD
TC
Tstg
Value
32
2
30
10
-10 … +50
-40 … +85
Unit
mW
V
V
MA
°C
°C
Specifications (TC=25°C, PO=30mW)
Item
Optical Specifications
Optical Output Power (CW)
Peak Wavelength
FWHM Beam Divergence
Emission Point Accuracy
Astigmatism
Electrical Specifications
Threshold Current
Operating Current
Slope Efficiency
Operating Voltage
Monitor Current
Angle
Symbol
Min.
Typ.
Max.
Unit
PO
λP
Θ║
Θ┴
Δθ║
Δθ┴
As
630
5
27
-3
-3
-80
30
638
8
32
-
645
12
37
+3
+3
+80
mW
nm
deg
deg
deg
deg
µm
Ith
Iop
η
Vop
Im
0.3
0.05
60
115
0.6
2.2
0.1
80
140
0.9
2.7
0.5
mA
mA
W/A
V
mA
The above specifications are for reference purpose only and subjected to change without prior notice.
14.12.2011
ADL-63302TL
1 of 3
Typical Performance Characteristics
14.12.2011
ADL-63302TL
2 of 3
Package Dimensons
5.6 mm TO (all dimensions in mm)
Safety of Laser light
•
Laser Light can damage the human eyes and skin. Do not expose the eye or
skin directly to any laser light and/or through optical lens. When handling the
LDs, wear appropriate safety glasses to prevent laser light, even any
reflections from entering to the eye. Focused laser beam through optical
instruments will increase the chance of eye hazard.
Cautions
1. Operating methode
•
•
This LD shall change its forward voltage requirement and optical ouput
power according to temperature change. Also, the LD will require more operation current to maintain
same ouput power as it degrades. In order to maintain output power, use of APC (Automatic Power
Control) is recommended. Which use monitor feedback to adjust the operation current.
Confirm that electrical spike current generated by switching on and off does not exceed the maximum
operating current level specified herein above as absolute maximum rating. Also, employ appropriat
countermeasures to reduce chattering and/or overshooting in the circuit.
2. Static Electricity
•
Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is
recommended to use a wrist trap or anti-electrostatic glove when handeling the product.
3. Absolute Maximum Rating
•
Active layer of LDs shall have high current density and generate high electric field during its operation.
In order to prevent excessive damage, the LD must be operated striclty below absolute maximum
rating.
14.12.2011
ADL-63302TL