ROITHNER RLT1060-50G

RLT1060-50G
TECHNICAL DATA
Infrared Laser Diode
Features
•
•
•
•
Lasing Mode Structure: Single mode
Peak Wavelength : typ. 1060 nm
Optical Ouput Power: 50 mW
Package: 9 mm
Electrical Connection
Pin Configuration
Bottom View
n-type
PIN
1
2
3
Function
LD Cathode
LD Anode, PD Cathode
PD Anode
Absolute Maximum Ratings (TC=25°C)
Item
CW Output Power
Maximum LD Current
Operating Case Temperature
Storage Temperature
Symbol
PO
If
TC
Tstg
Value
50
110
-20 … +40
-40 … +70
Unit
mW
mA
°C
°C
Specifications (TC=25°C)
Item
Optical Specification
CW Output Power
Peak Wavelength
Spectral Width (FWHM)
FWHM Beam Divergence
Emitting Aperature
Electrical Specification
Threshold Current
Operating Current
Operating Voltage
Monitor Current
Monitor Voltage
Symbol
Condition
Min.
Typ.
Max.
Unit
PO
λP
Δλ
θ║
θ┴
WxH
cw
PO = 50 mW
PO = 50 mW
PO = 50 mW
PO = 50 mW
1050
50
1060
1070
-
7.5
43
-
mW
nm
nm
deg
deg
µm
Ith
Iop
Uop
Im
Um
cw
PO = 50 mW
PO = 50 mW
PO = 50 mW
PO = 50 mW
-
35
90
-
2
-
-
5
mA
mA
V
µA
V
The above specifications are for reference purpose only and subjected to change without prior notice.
04.11.2011
RLT1060-50G
1 of 2
Package Dimensons
9 mm Package (Unit:mm)
Safety of Laser light
•
Laser Light can damage the human eyes and skin. Do not expose the eye or
skin directly to any laser light and/or through optical lens. When handling the
LDs, wear appropriate safety glasses to prevent laser light, even any
reflections from entering to the eye. Focused laser beam through optical
instruments will increase the chance of eye hazard.
•
These LDs are emitting invisible light.
Cautions
1. Operating methode
• This LD shall change its forward voltage requirement and optical ouput power according to
temperature change. Also, the LD will require more operation current to maintain same ouput
power as it degrades. In order to maintain output power, use of APC (Automatic Power
Control) is recommended. Which use monitor feedback to adjust the operation current.
• Confirm that electrical spike current generated by swithing on and off does not exceed the
maximum operating current level specified herein above as absolute maximum rating. Also,
employ appropriat countermeasures to reduce chattering and/or overshooting in the circuit.
2. Static Electricity
• Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is
recommended to use a wrist trap or anti-electrostatic glove when handeling the product.
3. Absolute Maximum Rating
• Active layer of LDs shall have high current density and generate high electric field during its
operation. In order to prevent excessive damage, the LD must be operated striclty below
absolute maximum rating.
04.11.2011
RLT1060-50G
2 of 2