Power Line Chokes Applications Power Amplifiers Filters Power Supplies SCR and Triac Controls Speaker Crossover Networks RFI Suppression Drum Core Style Part Number L DCR + 20% Nom. ( µH ) ( mΩ ) I Max. (A) Lead Size Pkg. AWG Code L-12200 L-12202 L-12203 L-12204 L-12205 L-12206 L-12207 2.0 4.0 8.0 18 22 30 40 5 10 12 13 16 21 32 16.4 10.3 8.2 8.2 6.5 5.2 4.0 14 16 17 17 18 19 20 1 1 1 1 1 1 1 L-12401 L-12402 L-12403 L-12406 L-12407 L-12408 L-12411 15 20 30 38 50 70 100 8 11 17 25 28 38 59 13.0 10.3 8.2 6.5 6.0 5.2 4.1 15 16 17 18 18 19 20 2 2 2 2 2 2 2 L-12220 L-12221 L-12222 L-12223 L-12224 L-12225 L-12226 L-12227 5.0 20 30 50 80 120 180 200 8 13 19 25 42 53 72 105 16.0 12.9 8.5 6.8 5.4 5.0 4.3 4.1 15 16 17 18 19 19 20 20 3 3 3 3 3 3 3 3 Flammability: Materials used in the production of these units are UL94-VO and meet requirements of IEC 695-2-2 needle flame test. Specifications subject to change without notice. Rhombus Industries Inc. Pre-Tinned Leads Center hole for mechanical mounting Coils finished with Polyolefin Shrink Tube Test Frequency 1 kHz D C B .750" TYP. A Pkg. Code 1 2 3 ( Dimensions in inches ) A B C D 0.560 0.709 0.709 0.810 0.795 0.866 0.187 0.187 0.187 0.126 0.126 0.126 For other values & Custom Designs, contact factory. www.rhombus-ind.com 15801 Chemical Lane, Huntington Beach, CA 92649-1595 Tel: (714) 898-0960 • Fax: (714) 896-0971 Power Line Chokes Drum Applications Power Amplifiers Filters Power Supplies SCR and Triac Controls Speaker Crossover Networks RFI Suppression Core Style Part Number L + 20% ( µH ) DCR Nom. ( mΩ ) I Max. (A) L-12420 L-12421 L-12423 L-12425 L-12428 L-12430 L-12431 L-12433 5.0 10 15 25 50 70 100 150 4 5 9 16 33 48 58 92 16.4 13.0 10.3 8.2 5.2 4.1 4.1 3.2 Lead Size Pkg. AWG Code 14 15 16 17 19 20 20 21 Pre-Tinned Leads Center hole for mechanical mounting Coils finished with Polyolefin Shrink Tube Test Frequency 1 kHz 4 4 4 4 4 4 4 4 D C B .7 5 0 TYP. L-12440 L-12441 L-12442 L-12443 L-12445 L-12446 L-12447 L-12450 L-12452 10 15 25 50 75 100 180 280 450 5 8 15 19 29 40 46 75 131 21.6 17.1 13.2 12.8 10.8 8.5 8.0 6.8 5.4 14 15 16 16 17 18 18 19 20 Flammability: Materials used in the production of these units are UL94-VO and meet requirements of IEC 695-2-2 needle flame test. Specifications subject to change without notice. Rhombus Industries Inc. 5 5 5 5 5 5 5 5 5 A Pkg. Code 4 5 ( Dimensions in inches ) A B C D 0.866 0.866 0.570 0.728 0.267 0.267 0.147 0.147 For other values & Custom Designs, contact factory. www.rhombus-ind.com 15801 Chemical Lane, Huntington Beach, CA 92649-1595 Tel: (714) 898-0960 • Fax: (714) 896-0971 Applications Power Amplifiers Filters Power Supplies SCR and Triac Controls Speaker Crossover Networks RFI Suppression Power Line Chokes Drum Core Style Part Number L DCR + 20% Nom. ( µH ) ( mΩ ) I Max. (A) Lead Size Pkg. AWG Code L-12470 L-12471 L-12472 L-12473 L-12474 L-12475 L-12478 L-12480 L-12481 18 30 50 80 120 200 300 450 680 5 13 25 33 36 57 85 136 170 24.0 18.0 15.0 13.2 13.0 10.1 8.0 6.1 6.0 14 15 16 17 17 18 19 20 20 6 6 6 6 6 6 6 6 6 L-12235 L-12236 L-12237 L-12239 L-12242 L-12243 L-12245 L-12247 40 60 100 150 250 380 580 880 13 19 28 38 73 86 120 200 24.5 18.0 16.0 13.5 11.0 8.5 6.0 5.4 14 15 15 16 18 18 20 20 7 7 7 7 7 7 7 7 L-12490 L-12492 L-12493 L-12495 L-12497 L-12500 L-12503 45 70 120 185 280 450 700 12 18 35 50 78 130 198 25.0 18.8 13.9 12.0 9.5 7.5 4.1 14 15 16 17 18 19 20 8 8 8 8 8 8 8 Flammability: Materials used in the production of these units are UL94-VO and meet requirements of IEC 695-2-2 needle flame test. Specifications subject to change without notice. Rhombus Industries Inc. Pre-Tinned Leads Center hole for mechanical mounting Coils finished with Polyolefin Shrink Tube Test Frequency 1 kHz D C B .750" TYP. A Pkg. Code 6 7 8 ( Dimensions in inches ) A B C D 0.949 0.955 1.100 0.795 0.975 0.805 0.187 0.187 0.237 0.126 0.126 0.175 For other values & Custom Designs, contact factory. www.rhombus-ind.com 15801 Chemical Lane, Huntington Beach, CA 92649-1595 Tel: (714) 898-0960 • Fax: (714) 896-0971 Power Line Chokes Drum Applications Power Amplifiers Filters Power Supplies SCR and Triac Controls Speaker Crossover Networks RFI Suppression Core Style Part Number L + 20% ( µH ) DCR Nom. ( mΩ ) I Max. (A) Lead Size Pkg. AWG Code L-12530 L-12531 L-12534 L-12536 L-12538 L-12540 L-12543 L-12545 80 100 180 300 450 700 1300 2000 17 27 40 78 100 150 260 350 19.3 16.0 12.5 10.0 8.0 6.4 5.0 4.5 14 15 16 17 18 19 20 20 9 9 9 9 9 9 9 9 L-12254 L-12256 L-12257 L-12259 L-12262 L-12264 L-12266 L-12267 100 200 300 450 700 1000 1500 2000 22 38 56 70 130 166 250 340 12.0 10.0 8.5 8.5 5.5 5.5 4.3 3.4 14 15 16 16 18 18 20 20 10 10 10 10 10 10 10 10 L-12560 L-12561 L-12563 L-12564 L-12566 L-12567 L-12569 L-12571 L-12573 150 400 500 1000 1500 2000 3000 4700 7000 16 43 61 109 141 181 300 470 680 20.5 11.9 10.6 7.6 6.2 5.8 4.5 3.5 3.0 12 14 15 16 16 17 18 19 20 11 11 11 11 11 11 11 11 11 Pre-Tinned Leads Center hole for mechanical mounting Coils finished with Polyolefin Shrink Tube Test Frequency 1 kHz D C B Flammability: Materials used in the production of these units are UL94-VO and meet requirements of IEC 695-2-2 needle flame test. Specifications subject to change without notice. Rhombus Industries Inc. .750" TYP. A Pkg. Code 9 10 11 ( Dimensions in inches ) A B C D 1.100 1.390 1.390 1.010 1.010 1.380 0.237 0.315 0.315 0.175 0.190 0.190 For other values & Custom Designs, contact factory. www.rhombus-ind.com 15801 Chemical Lane, Huntington Beach, CA 92649-1595 Tel: (714) 898-0960 • Fax: (714) 896-0971 Power Line Chokes Drum Applications Power Amplifiers Filters Power Supplies SCR and Triac Controls Speaker Crossover Networks RFI Suppression Core Style Part Number L + 20% ( µH ) DCR Nom. ( mΩ ) I Max. (A) Lead Size Pkg. AWG Code L-12590 L-12591 L-12592 L-12593 L-12595 L-12597 L-12598 L-12599 L-12601 L-12603 L-12605 L-12606 200 300 450 700 1000 1700 2000 2600 3800 7900 10000 15000 19 25 44 59 97 148 170 220 340 650 920 960 19.2 17.8 15.0 11.7 9.4 7.6 6.8 6.0 5.0 3.4 3.0 2.9 11 12 14 14 15 16 16 17 18 19 20 20 12 12 12 12 12 12 12 12 12 12 12 12 L-12630 L-12632 L-12634 L-12636 L-12637 L-12639 L-12641 L-12643 L-12645 L-12648 200 380 750 1000 1600 2500 4000 6500 12000 18000 15 30 53 79 134 200 320 500 900 1400 28.8 21.4 15.6 13.2 10.5 7.8 6.5 5.2 3.8 3.6 10 12 13 14 15 16 17 18 19 20 13 13 13 13 13 13 13 13 13 13 Flammability: Materials used in the production of these units are UL94-VO and meet requirements of IEC 695-2-2 needle flame test. Specifications subject to change without notice. Rhombus Industries Inc. Pre-Tinned Leads Center hole for mechanical mounting Coils finished with Polyolefin Shrink Tube Test Frequency 1 kHz D C B .750" TYP. A Pkg. Code 12 13 ( Dimensions in inches ) A B C D 1.770 2.200 1.380 1.380 0.360 0.380 0.270 0.290 For other values & Custom Designs, contact factory. www.rhombus-ind.com 15801 Chemical Lane, Huntington Beach, CA 92649-1595 Tel: (714) 898-0960 • Fax: (714) 896-0971