ETC 812012

EC Safety Data Sheet according to Directive 1907/2006
Trade name: Solder-wire KS 115 FLOWTIN ® TSC
Date of issue: 15.12.2005
Revised on: 24.05.2011
Date of print: 08.11.2011
Page: 1(3)
1. Name of product, characterization and company name
Information on the product
Trade name:
Usage of the product / preparation
Solder-wire KS 115 FLOWTIN ® TSC
Solder wire for soft soldering
Identification of the manufacturer / supplier
Address:
MULTICOMP Premier Farnell plc
150 Armley Road
LEEDS LS12 2QQ
+44 (0) 870 129 8608
Phone:
Fax:
Emergency call:
E-mail:
+44 (0) 870 202530 (During office hours only)
2. Possible hazards:
Not a composition for the purposes of the Dangerous Substances Regulations, but nevertheless observe items 4-16
3. Composition/Information on the components
Chemical characterization: Tin-copper-silver alloy (with <0,1 % other iron-metals) with flux max. 3,5 % modified resin
(halide-activated)
Composition according to EC 1907/2006:
Contents
remainder
0,6-0,8%
3,6-4,0%
<3,5%
CAS No.
7440-31-5
7440-50-8
7440-22-4
EINECS No.
231-141-8
231-159-6
231-131-3
Symbols
R-phrases:
Substance
Tin
copper
silver
modified resin
The wording of the R-phrases stated is indicated in Section 16
4. First Aid measures
General information:
After inhalation:
After skin contact:
After eye contact:
After ingestion:
Hints for doctors.
If casualty is unconscious but breathing, place in the recovery position. If breathing
has stopped apply artificial resuscitation or give oxygen by mask
Remove patient to fresh air. If irritation resists, obtain medical attention.
If any skin irritation develops seek medical attention
Flush immediately with plenty of water. In cases where spitting flux has entered
the eye seek medical attention.
Rinse mouth immediately and drink plenty of water. Seek medical advice.
Inhalation of the flux fumes given off at soldering temperatures will irritate the nose,
throat and respiratory system. Repeated or prolonged exposure to flux fumes
may cause shortness of breath and cough..
Physician's information
Treatment:
Decontamination, treatment of symptoms.
5. Fire fighting measures
Suitable extinguishing media:
Special protective equipment for fire
fighting
Use extinguishing media appropriate to surrounding fire conditions
Wear self-contained breathing apparatus and protective clothing to prevent contact with
skin and eyes.
6. Accidental release measures
Pick up and place in appropriate container
7. Handling and storage
The fumes produced during soldering should be extracted away from the breathing zone of the operators. Ensure the area is well
ventilated. Wash hands with soap and warm water after handling, particularly before eating, drinking or smoking.
The product should be stored in a cool, dry area.
EC Safety Data Sheet according to Directive 1907/2006
Trade name: Solder-wire KS 115 FLOWTIN ® TSC
Date of issue: 15.12.2005
Revised on: 24.05.2011
Date of print: 08.11.2011
Page: 2(3)
8. Exposure controls and personal protection
Additional information on system design:
Local exhaust or dilution ventilation and control of process conditions are suitable methods..
Substances with limit values to be monitored at the working place:
Danger to health at the working place:
Peak limit category:
Working place limit values according to TRGS 900 from Section 2 for Germany:
Product name
CAS No.
ml/m³ (ppm) mg/m³
Type
Tin
7440-31-5
2
MAK (NL)
Copper
7440-50-8
1
MAK (DFG)
Silber
7440-22-4
0,1
MAK (DFG)
Skin resorption / Sensitization: Skin resorption ---Sensitization: ----General protection and hygiene measures
Avoid direct contact with eyes, the skin and clothing.
Personal protection
Respiratory protection:
If concentrations are over the exposure limit, use a supplied air respirator.
Hand protection:
Use heat resistant gloves if required.
Eye protection:
Operators should wear goggles
Personal protection:
Light protective clothing
9. Physical and chemical properties
Form:
Melting Point:
Vapour Pressure:
Density(20°C):
Form: Tin-Copper Solder
Colour:silver
217°C
n.a.
7-8 g/cm³
10. Stability and reactivity
Reaction with substances:
Hazardous combustion or
decomposition products:
Possible with oxidising agents.
none
11. Toxicological information
The toxicological classification of the product is based on the results of the calculation procedure of the general preparation directive
1999/45/EC.
Acute Effects:
None toxic metal.
12. Ecological information
General information:
No effect to environment known
13. Disposal considerations
Disposal information
Product:
Further information:
Waste identity number:
Contact a licensed professional waste disposal service to dispose of this material.
Observe all federal, state and local environmental regulations. Collect metal for recycling
Waste identity number EAK-code: 120104
14. Transport information
GGVSEB/ADR
The product is not classified as hazardous for transport
EC Safety Data Sheet according to Directive 1907/2006
Trade name: Solder-wire KS 115 FLOWTIN ® TSC
Date of issue: 15.12.2005
Revised on: 24.05.2011
Date of print: 08.11.2011
15. Legal regulations:
Labelling information:
Water hazard class:
Classification according to the TA Luft:
Ingredients:
The product is classified and labelled according to the EC Directives.
Not subject to current legislation
WGK 1 (weakly water-endangering)
Organic materials class III; whole-carbon-concentration: Max. acceptable
Emission50 mg/m^3 (mass-flow-rate >= 0,5 kg/h)
Tin, copper,silver, resin
16. Further information
R-phrases point 3:-----------------------------n.k.: not known
n.a.: not applicable
Other information
This statement is based on our current knowledge and offers no assurance of product properties.
Page: 3(3)