T5V0DLP ADVANCE INFORMATION LOW CAPACITANCE SURFACE MOUNT DUAL TVS Features Mechanical Data 25 Watts Peak Pulse Power (tp = 8x20µs) IEC 61000-4-2 (ESD): Air – 15kV, Contact – 8kV IEC61000-4-4 (EFT): 40A 5/50ns Dual TVS for protection of up to two data lines Moisture Sensitivity: Level 1 per J-STD-020 Low Capacitance (9pF typ), suitable for USB2.0 dataline Terminal Connections Indicator: Cathode Bar protection Terminals: Finish NiPdAu over Copper leadframe. Solderable per MIL-STD-202, Method 208 e4 Weight: 0.0009 grams Case: X1-DFN1006-3 Case Material: Molded Plastic, "Green" Molding Compound. UL Flammability Classification Rating 94V-0 Subminiature, low-profile package suitable for portable applications - case outline of only 1.0 * 0.6 * 0.5mm Totally Lead-Free & Fully RoHS Compliant (Notes 1 & 2) Halogen and Antimony Free. “Green” Device (Note 3) X1-DFN1006-3 Bottom View Ordering Information (Note 4) Part Number T5V0DLP-7B Notes: Device Schematic Case X1-DFN1006-3 Packaging 10,000/Tape & Reel 1. No purposely added lead. Fully EU Directive 2002/95/EC (RoHS) & 2011/65/EU (RoHS 2) compliant. 2. See http://www.diodes.com/quality/lead_free.html for more information about Diodes Incorporated’s definitions of Halogen- and Antimony-free, "Green" and Lead-free. 3. Halogen- and Antimony-free "Green” products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl) and <1000ppm antimony compounds. 4. For packaging details, go to our website at http://www.diodes.com/products/packages.html. Marking Information AB AB = Product Type Marking Code Bar Denotes Cathode Side T5V0DLP Document number: DS31906 Rev. 3 - 2 1 of 4 www.diodes.com March 2014 © Diodes Incorporated T5V0DLP Thermal Characteristics Characteristic Value (Note 5) TA = +25°C Ppk 25 W Power dissipation (Note 5) TA = +25°C PD 385 mW Thermal Resistance, Junction to Ambient (Note 5) TA = +25°C RθJA 325 °C/W TJ, TSTG -55 to +150 °C Operating and Storage Temperature Range Unit Electrical Characteristics (@TA = +25°C, unless otherwise specified.) Breakdown Voltage VBR @ IT Reverse Standoff Voltage Test Current Max. Reverse Leakage @ VRWM (Note 6) Max. Clamping Voltage VC @ IPP (Note 7) Max Total Capacitance CT (Note 8) VR = 0V Typical Total Capacitance CT (Note 8) VR = 3.3V VRWM (V) Min (V) Max (V) IT (mA) IR (µA) VC (V) IPP (A) (pF) (pF) 5 6.1 8 1.0 0.25 12.5 2 9 4.5 Notes: 5. Device mounted on FR-4 PC board with suggested pad layout, which can be found on our website at http://www.diodes.com/datasheets/ap02001.pdf. 6. Short duration pulse test used to minimize self-heating effect. 7. Clamping voltage value is based on an 8x20µs peak pulse current (Ipp) waveform. 8. f = 1MHz 10 100 Peak Value I pp CT, TOTAL CAPACITANCE (pF) Ipp, PEAK PULSE CURRENT (%Ipp) f = 1MHz Half Value Ipp/2 50 0 0 8 6 4 2 8x20 Waveform as defined by R.E.A. 20 40 t, TIME (s) Figure 1 Pulse Waveform 0 60 0 1 2 3 4 5 VR, REVERSE VOLTAGE (V) Figure 2 Total Capacitance 6 1000 10000 1000 IR, LEAKAGE CURRENT (nA) IF, INSTANTANEOUS FORWARD CURRENT (mA) ADVANCE INFORMATION Symbol Peak Pulse Power (tp = 8x20µs) 100 100 10 TA = 150°C TA = 125°C 1 TA = 85°C TA = 25°C 0.1 T A = -55°C TA = 150°C 10 T A = 85°C TA = 25°C TA = -55°C 1 0.01 0.001 100 300 500 700 900 1100 1300 VF, INSTANTANEOUS FORWARD VOLTAGE (mV) Figure 3 Typical Forward Characteristics T5V0DLP Document number: DS31906 Rev. 3 - 2 2 of 4 www.diodes.com 0.1 0 1 2 3 4 5 6 7 VR, REVERSE VOLTAGE (V) Figure 4 Typical Reverse Characteristics 8 March 2014 © Diodes Incorporated T5V0DLP 500 PD,POWER DISSIPATION (mW) ADVANCE INFORMATION Note 5 400 300 200 100 0 0 40 80 120 160 TA, AMBIENT TEMPERATURE (°C) Figure 5 Power Derating Curve 200 Package Outline Dimensions Please see AP02002 at http://www.diodes.com/datasheets/ap02002.pdf for latest version. A A1 D b1 E e b2 L2 L3 X1-DFN1006-3 Dim Min Max Typ A 0.47 0.53 0.50 A1 0 0.05 0.03 b1 0.10 0.20 0.15 b2 0.45 0.55 0.50 D 0.95 1.075 1.00 E 0.55 0.675 0.60 e 0.35 L1 0.20 0.30 0.25 L2 0.20 0.30 0.25 L3 0.40 All Dimensions in mm L1 Suggested Pad Layout Please see AP02001 at http://www.diodes.com/datasheets/ap02001.pdf for latest version. C X1 X Dimensions Z G1 G2 X X1 Y C G2 G1 Y Z T5V0DLP Document number: DS31906 Rev. 3 - 2 3 of 4 www.diodes.com Value (in mm) 1.1 0.3 0.2 0.7 0.25 0.4 0.7 March 2014 © Diodes Incorporated T5V0DLP ADVANCE INFORMATION IMPORTANT NOTICE DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION). Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated website, harmless against all damages. Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. This document is written in English but may be translated into multiple languages for reference. Only the English version of this document is the final and determinative format released by Diodes Incorporated. LIFE SUPPORT Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or to affect its safety or effectiveness. Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems. Copyright © 2014, Diodes Incorporated www.diodes.com T5V0DLP Document number: DS31906 Rev. 3 - 2 4 of 4 www.diodes.com March 2014 © Diodes Incorporated