AD AD7713AR

LC2MOS
Loop-Powered Signal Conditioning ADC
AD7713
APPLICATIONS
Loop Powered (Smart) Transmitters
RTD Transducers
Process Control
Portable Industrial Instruments
GENERAL DESCRIPTION
The AD7713 is a complete analog front end for low frequency
measurement applications. The device accepts low level signals
directly from a transducer or high level signals (4 ⫻ VREF) and
outputs a serial digital word. It employs ⌺-⌬ conversion
technique to realize up to 24 bits of no missing codes
performance. The input signal is applied to a proprietary programmable gain front end based around an analog modulator.
The modulator output is processed by an on-chip digital filter.
The first notch of this digital filter can be programmed via the
on-chip control register, allowing adjustment of the filter cutoff
and settling time.
The part features two differential analog inputs and one singleended high level analog input as well as a differential reference
input. It can be operated from a single supply (AVDD and DVDD
at 5 V). The part provides two current sources that can be used
to provide excitation in 3-wire and 4-wire RTD configurations.
The AD7713 thus performs all signal conditioning and conversion for a single-, dual- or three-channel system.
The AD7713 is ideal for use in smart, microcontroller-based
systems. Gain settings, signal polarity, and RTD current control
can be configured in software using the bidirectional serial port.
The AD7713 contains self-calibration, system calibration, and
background calibration options and also allows the user to read
and to write the on-chip calibration registers.
FUNCTIONAL BLOCK DIAGRAM
REF REF
AVDD DVDD IN(–) IN(+)
STANDBY
AVDD
AD7713
1␮A
CHARGING BALANCING ADC
AIN1(+)
AIN1(–)
AIN2(+)
AIN2(–)
AIN3
MUX
FEATURES
Charge Balancing ADC
24 Bits No Missing Codes
ⴞ0.0015% Nonlinearity
3-Channel Programmable Gain Front End
Gains from 1 to 128
2 Differential Inputs
1 Single-Ended High Voltage Input
Low-Pass Filter with Programmable Filter Cutoffs
Ability to Read/Write Calibration Coefficients
Bidirectional Microcontroller Serial Interface
Single-Supply Operation
Low Power (3.5 mW typ) with Power-Down Mode
(150 ␮W typ)
INPUT
SCALING
AUTO-ZEROED
⌺-⌬
MODULATOR
PGA
DIGITAL
FILTER
A = 1 – 128
CLOCK
GENERATION
200␮A AVDD
SYNC
MCLK
IN
MCLK
OUT
SERIAL INTERFACE
RTD1
CONTROL
REGISTER
200␮A
OUTPUT
REGISTER
RTD2
AGND DGND
RFS
TFS MODE SDATA SCLK DRDY A0
CMOS construction ensures low power dissipation, and a hardware programmable power-down mode reduces the standby
power consumption to only 150 µW typical. The part is available
in a 24-lead, 0.3 inch wide, PDIP and CERDIP as well as a 24lead SOIC package.
PRODUCT HIGHLIGHTS
1. The AD7713 consumes less than 1 mA in total supply current,
making it ideal for use in loop-powered systems.
2. The two programmable gain channels allow the AD7713 to
accept input signals directly from a transducer removing a
considerable amount of signal conditioning. To maximize
the flexibility of the part, the high level analog input accepts
4 ⫻ VREF signals. On-chip current sources provide excitation
for 3-wire and 4-wire RTD configurations.
3. No missing codes ensures true, usable, 24-bit dynamic range
coupled with excellent ± 0.0015% accuracy. The effects of
temperature drift are eliminated by on-chip self-calibration,
which removes zero-scale and full-scale errors.
4. The AD7713 is ideal for microcontroller or DSP processor
applications with an on-chip control register, which allows
control over filter cutoff, input gain, signal polarity, and
calibration modes. The AD7713 allows the user to read and
write the on-chip calibration registers.
REV. D
Information furnished by Analog Devices is believed to be accurate and
reliable. However, no responsibility is assumed by Analog Devices for its
use, nor for any infringements of patents or other rights of third parties that
may result from its use. No license is granted by implication or otherwise
under any patent or patent rights of Analog Devices. Trademarks and
registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781/329-4700
www.analog.com
Fax: 781/326-8703
© 2004 Analog Devices, Inc. All rights reserved.
AD7713–SPECIFICATIONS
(AVDD = 5 V ⴞ 5%; DVDD = 5 V ⴞ 5%; REF IN(+) = 2.5 V; REF IN(–) = AGND;
MCLK IN = 2 MHz, unless otherwise noted. All specifications TMIN to TMAX, unless otherwise noted.)
Parameter
A, S Versions1
Unit
Conditions/Comments
STATIC PERFORMANCE
No Missing Codes
24
Bits min
22
18
15
12
See Tables I and II
± 0.0015
Bits min
Bits min
Bits min
Bits min
% of FSR max
Guaranteed by Design.
For Filter Notches ≤ 12 Hz.
For Filter Notch = 20 Hz.
For Filter Notch = 50 Hz.
For Filter Notch = 100 Hz.
For Filter Notch = 200 Hz.
Depends on Filter Cutoffs and Selected Gain.
Filter Notches ≤ 12 Hz; Typically ± 0.0003%.
1
0.3
µV/°C typ
µV/°C typ
For Gains of 1, 2.
For Gains of 4, 8, 16, 32, 64, 128.
0.5
0.25
µV/°C typ
µV/°C typ
For Gains of 1, 2.
For Gains of 4, 8, 16, 32, 64, 128.
0.5
0.25
2
± 0.0004
1
0.3
µV/°C typ
µV/°C typ
ppm/°C typ
% of FSR max
µV/°C typ
µV/°C typ
For Gains of 1, 2.
For Gains of 4, 8, 16, 32, 64, 128.
See Table III
100
dB min
100
dB min
Output Noise
Integral Nonlinearity
Positive Full-Scale Error2, 3, 4
Full-Scale Drift5
Unipolar Offset Error2, 4
Unipolar Offset Drift5
Bipolar Zero Error2, 4
Bipolar Zero Drift5
Gain Drift
Bipolar Negative Full-Scale Error2
Bipolar Negative Full-Scale Drift5
ANALOG INPUTS
Input Sampling Rate, fS
Normal-Mode 50 Hz Rejection6
Normal-Mode 60 Hz Rejection6
AIN1, AIN27
Input Voltage Range8
0 to +VREF9
V max
± VREF
V max
Common-Mode 50 Hz Rejection6
100
90
150
dB min
dB min
dB min
Common-Mode 60 Hz Rejection6
150
dB min
AGND to AVDD
10
1
20
V min to V max
pA max
nA max
pF max
0 to + 4 ⫻ VREF
V max
Gain Error11
± 0.05
% typ
Gain Drift
1
ppm/°C typ
Offset Error11
4
mV max
Input Impedance
30
kΩ min
Common-Mode Rejection (CMR)
Common-Mode Voltage Range10
DC Input Leakage Current @ 25°C
TMIN to TMAX
Sampling Capacitance6
AIN3
Input Voltage Range
–2–
Typically ± 0.0006%.
For Gains of 1, 2.
For Gains of 4, 8, 16, 32, 64, 128.
For Filter Notches of 2 Hz, 5 Hz, 10 Hz,
25 Hz, 50 Hz, ± 0.02 ⫻ fNOTCH.
For Filter Notches of 2 Hz, 6 Hz, 10 Hz,
30 Hz, 60 Hz, ± 0.02 ⫻ fNOTCH.
For Normal Operation.
Depends on Gain Selected.
Unipolar Input Range
(B/U Bit of Control Register = 1).
Bipolar Input Range
(B/U Bit of Control Register = 0).
At dc and AVDD = 5 V.
At dc and AVDD = 10 V.
For Filter Notches of 2 Hz, 5 Hz, 10 Hz,
25 Hz, 50 Hz, ± 0.02 ⫻ fNOTCH.
For Filter Notches of 2 Hz, 6 Hz, 10 Hz,
30 Hz, 60 Hz, ± 0.02 ⫻ fNOTCH.
For Normal Operation. Depends on Gain
Selected.
Additional Error Contributed by Resistor
Attenuator.
Additional Drift Contributed by Resistor
Attenuator.
Additional Error Contributed by Resistor
Attenuator.
REV. D
AD7713
Parameter
A, S Versions1
Unit
Conditions/Comments
REFERENCE INPUT
REF IN(+) – REF IN(–) Voltage
2.5 to AVDD/1.8
V min to V max
For Specified Performance. Part Is
Functional with Lower VREF Voltages.
Input Sampling Rate, fS
Normal-Mode 50 Hz Rejection6
fCLK IN/512
100
dB min
Normal-Mode 60 Hz Rejection6
100
dB min
Common-Mode Rejection (CMR)
Common-Mode 50 Hz Rejection6
100
150
dB min
dB min
Common-Mode 60 Hz Rejection6
150
dB min
Common-Mode Voltage Range10
DC Input Leakage Current @ 25°C
TMIN to TMAX
For Filter Notches of 2 Hz, 5 Hz, 10 Hz,
25 Hz, 50 Hz, ± 0.02 ⫻ fNOTCH.
For Filter Notches of 2 Hz, 6 Hz, 10 Hz,
30 Hz, 60 Hz, ± 0.02 ⫻ fNOTCH.
At DC.
For Filter Notches of 2 Hz, 5 Hz, 10 Hz,
25 Hz, 50 Hz, ± 0.02 ⫻ fNOTCH.
For Filter Notches of 2 Hz, 6 Hz, 10 Hz,
30 Hz, 60 Hz, ± 0.02 ⫻ fNOTCH.
AGND to AVDD
10
1
V min to V max
pA max
nA max
± 10
µA max
0.8
2.0
V max
V min
0.8
3.5
V max
V min
LOGIC OUTPUTS
VOL, Output Low Voltage
VOH, Output High Voltage
Floating State Leakage Current
Floating State Output Capacitance12
0.4
4.0
± 10
9
V max
V min
µA max
pF typ
TRANSDUCER BURN-OUT
Current
Initial Tolerance @ 25°C
Drift
1.2
± 10
0.1
µA nom
% typ
%/°C typ
RTD EXCITATION CURRENTS
(RTD1, RTD2)
Output Current
Initial Tolerance @ 25°C
Drift
Initial Matching @ 25°C
Drift Matching
200
± 20
20
±1
3
µA nom
% max
ppm/°C typ
% max
ppm/°C typ
200
200
nA/V max
nA/V max
LOGIC INPUTS
Input Current
All Inputs Except MCLK IN
VINL, Input Low Voltage
VINH, Input High Voltage
MCLK IN Only
VINL, Input Low Voltage
VINH, Input High Voltage
Line Regulation (AVDD)
Load Regulation
SYSTEM CALIBRATION
AIN1, AIN2
Positive Full-Scale Calibration Limit13
+(1.05 ⫻ VREF)/GAIN V max
Negative Full-Scale Calibration Limit13
–(1.05 ⫻ VREF)/GAIN V max
Offset Calibration Limit14, 15
–(1.05 ⫻ VREF)/GAIN V max
Input Span14
+(0.8 ⫻ VREF)/GAIN V min
+(2.1 ⫻ VREF)/GAIN V max
REV. D
–3–
ISINK = 1.6 mA.
ISOURCE = 100 µA.
Matching Between RTD1 and RTD2 Currents.
Matching Between RTD1 and RTD2 Current
Drift.
AVDD = 5 V.
GAIN Is the Selected PGA Gain
(Between 1 and 128).
GAIN Is the Selected PGA Gain
(Between 1 and 128).
GAIN Is the Selected PGA Gain
(Between 1 and 128).
GAIN Is the Selected PGA Gain
(Between 1 and 128).
GAIN Is the Selected PGA Gain
(Between 1 and 128).
AD7713
Parameter
AIN3
Positive Full-Scale Calibration Limit13
A, S Versions1
Unit
+(4.2 ⫻ VREF)/GAIN V max
Offset Calibration Limit15
0 to VREF/GAIN
Input Span
+(3.2 ⫻ VREF)/GAIN V min
V max
+(4.2 ⫻ VREF)/GAIN V max
POWER REQUIREMENTS
Power Supply Voltages
AVDD Voltage16
DVDD Voltage17
Power Supply Currents
AVDD Current
DVDD Current
Power Supply Rejection18
(AVDD and DVDD)19
Power Dissipation
Normal Mode
Standby (Power-Down) Mode
Conditions/Comments
GAIN Is the Selected PGA Gain
(Between 1 and 128).
GAIN Is the Selected PGA Gain
(Between 1 and 128).
GAIN Is the Selected PGA Gain
(Between 1 and 128).
GAIN Is the Selected PGA Gain
(Between 1 and 128).
5 to 10
5
V nom
V nom
± 5% for Specified Performance.
± 5% for Specified Performance.
0.6
0.7
0.5
mA max
mA max
mA max
1
mA max
AVDD = 5 V.
AVDD = 10 V.
fCLK IN = 1 MHz.
Digital Inputs 0 V to DVDD.
fCLK IN = 2 MHz.
Digital Inputs 0 V to DVDD.
Rejection w.r.t. AGND.
dB typ
5.5
mW max
300
µW max
AVDD = DVDD = 5 V, fCLK IN = 1 MHz;
Typically 3.5 mW.
AVDD = DVDD = 5 V, Typically 150 µW.
NOTES
1
Temperature range is: A Version, –40°C to +85°C; S Version, –55°C to +125°C.
2
Applies after calibration at the temperature of interest.
3
Positive full-scale error applies to both unipolar and bipolar input ranges.
4
These errors will be of the order of the output noise of the part as shown in Table I after system calibration. These errors will be 20 µV typical after self-calibration
or background calibration.
5
Recalibration at any temperature or use of the background calibration mode will remove these drift errors.
6
These numbers are guaranteed by design and/or characterization.
7
The AIN1 and AIN2 analog inputs present a very high impedance dynamic load that varies with clock frequency and input sample rate. The maximum recommended source resistance depends on the selected gain.
8
The analog input voltage range on the AIN1(+) and AIN2(+) inputs is given here with respect to the voltage on the AIN1(–) and AIN2(–) inputs. The input voltage
range on the AIN3 input is with respect to AGND. The absolute voltage on the AIN1 and AIN2 inputs should not go more positive than AV DD + 30 mV or more
negative than AGND – 30 mV.
9
VREF = REF IN(+) – REF IN(–).
10
This common-mode voltage range is allowed, provided that the input voltage on AIN(+) and AIN(–) does not exceed AV DD + 30 mV and AGND – 30 mV.
11
This error can be removed using the system calibration capabilities of the AD7713. This error is not removed by the AD7713’s self-calibration feature. The offset
drift on the AIN3 input is four times the value given in the Static Performance section of the specifications.
12
Guaranteed by design, not production tested.
13
After calibration, if the analog input exceeds positive full scale, the converter will output all 1s. If the analog input is less than negative full scale, the device will
output all 0s.
14
These calibration and span limits apply provided the absolute voltage on the AIN1 and AIN2 analog inputs does not exceed AV DD + 30 mV or go more negative than
AGND – 30 mV.
15
The offset calibration limit applies to both the unipolar zero point and the bipolar zero point.
16
Operating with AV DD voltages in the range 5.25 V to 10.5 V is guaranteed only over the 0°C to 70°C temperature range.
17
The ± 5% tolerance on the DV DD input is allowed provided that DV DD does not exceed AV DD by more than 0.3 V.
18
Measured at dc and applies in the selected pass band. PSRR at 50 Hz will exceed 120 dB with filter notches of 2 Hz, 5 Hz, 10 Hz, 25 Hz, or 50 Hz. PSRR at 60 Hz
will exceed 120 dB with filter notches of 2 Hz, 6 Hz, 10 Hz, 30 Hz, or 60 Hz.
19
PSRR depends on gain: gain of 1 = 70 dB typ; gain of 2 = 75 dB typ; gain of 4 = 80 dB typ; gains of 8 to 128 = 85 dB typ.
Specifications subject to change without notice.
–4–
REV. D
AD7713
TIMING CHARACTERISTICS1, 2
Parameter
fCLK IN
3, 4
tCLK IN LO
tCLK IN HI
tr5
tf 5
t1
Self-Clocking Mode
t2
t3
t4
t5
t6
t7 6
t8 6
t9
t10
t14
t15
t16
t17
t18
t19
External-Clocking Mode
fSCLK
t20
t21
t22
t23
t246
t256
t26
t27
t28
t297
t30
t317
t32
t33
t34
t35
t36
(DVDD = 5 V ⴞ 5%; AVDD = 5 V or 10 V ⴞ 5%; AGND = DGND = 0 V; fCLKIN = 2 MHz;
Input Logic 0 = 0 V, Logic 1 = DVDD, unless otherwise noted.)
Limit at TMIN, TMAX
(A, S Versions)
Unit
Conditions/Comments
400
2
0.4 ⫻ tCLK IN
0.4 ⫻ tCLK IN
50
50
1000
kHz min
MHz max
ns min
ns min
ns max
ns max
ns min
Master Clock Frequency: Crystal Oscillator or
Externally Supplied for Specified Performance
Master Clock Input Low Time; tCLK IN = 1/fCLK IN
Master Clock Input High Time
Digital Output Rise Time; Typically 20 ns
Digital Output Fall Time; Typically 20 ns
SYNC Pulse Width
0
0
2 ⫻ tCLK IN
0
4 ⫻ tCLK IN + 20
4 ⫻ tCLK IN +20
tCLK IN/2
tCLK IN/2 + 30
tCLK IN/2
3 ⫻ tCLK IN/2
50
0
4 ⫻ tCLK IN + 20
4 ⫻ tCLK IN
0
10
ns min
ns min
ns min
ns min
ns max
ns max
ns min
ns max
ns nom
ns nom
ns min
ns min
ns max
ns min
ns min
ns min
DRDY to RFS Setup Time
DRDY to RFS Hold Time
A0 to RFS Setup Time
A0 to RFS Hold Time
RFS Low to SCLK Falling Edge
Data Access Time (RFS Low to Data Valid)
SCLK Falling Edge to Data Valid Delay
fCLK IN/5
0
0
2 ⫻ tCLK IN
0
4 ⫻ tCLK IN
10
2 ⫻ tCLK IN + 20
2 ⫻ tCLK IN
2 ⫻ tCLK IN
tCLK IN + 10
10
tCLK IN + 10
10
5 ⫻ tCLK IN/2 + 50
0
0
4 ⫻ tCLK IN
2 ⫻ tCLK IN – SCLK High
30
MHz max
ns min
ns min
ns min
ns min
ns max
ns min
ns max
ns min
ns min
ns max
ns min
ns max
ns min
ns max
ns min
ns min
ns min
ns min
ns min
SCLK High Pulse Width
SCLK Low Pulse Width
A0 to TFS Setup Time
A0 to TFS Hold Time
TFS to SCLK Falling Edge Delay Time
TFS to SCLK Falling Edge Hold Time
Data Valid to SCLK Setup Time
Data Valid to SCLK Hold Time
Serial Clock Input Frequency
DRDY to RFS Setup Time
DRDY to RFS Hold Time
A0 to RFS Setup Time
A0 to RFS Hold Time
Data Access Time (RFS Low to Data Valid)
SCLK Falling Edge to Data Valid Delay
SCLK High Pulse Width
SCLK Low Pulse Width
SCLK Falling Edge to DRDY High
SCLK to Data Valid Hold Time
RFS/TFS to SCLK Falling Edge Hold Time
RFS to Data Valid Hold Time
A0 to TFS Setup Time
A0 to TFS Hold Time
SCLK Falling Edge to TFS Hold Time
Data Valid to SCLK Setup Time
Data Valid to SCLK Hold Time
NOTES
1
Guaranteed by design, not production tested. All input signals are specified with tr = tf = 5 ns (10% to 90% of 5 V) and timed from a voltage level of 1.6 V.
2
See Figures 10 to 13.
3
CLK IN duty cycle range is 45% to 55%. CLK IN must be supplied whenever the AD7713 is not in standby mode. If no clock is present in this case, the device can
draw higher current than specified and possibly become uncalibrated.
4
The AD7713 is production tested with f CLK IN at 2 MHz. It is guaranteed by characterization to operate at 400 kHz.
5
Specified using 10% and 90% points on waveform of interest.
6
These numbers are measured with the load circuit of Figure 1 and defined as the time required for the output to cross 0.8 V or 2.4 V.
7
These numbers are derived from the measured time taken by the data output to change 0.5 V when loaded with the circuit of Figure 1. The measured number is then
extrapolated back to remove effects of charging or discharging the 100 pF capacitor. This means that the times quoted in the timing characteristics are the true bus
relinquish times of the part and, as such, are independent of external bus loading capacitances.
REV. D
–5–
AD7713
ABSOLUTE MAXIMUM RATINGS*
ORDERING GUIDE
(TA = 25°C, unless otherwise noted.)
AVDD to AGND . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +12 V
AVDD to DGND . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +12 V
DVDD to AGND . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +6 V
DVDD to DGND . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +6 V
AGND to DGND . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +6 V
AIN1, AIN2 Input Voltage
to AGND . . . . . . . . . . . . . . . . . . . . . –0.3 V to AVDD + 0.3 V
AIN3 Input Voltage to AGND . . . . . . . . . . . . –0.3 V to +22 V
Reference Input Voltage to AGND . . . –0.3 V to AVDD + 0.3 V
Digital Input Voltage to DGND . . . . . –0.3 V to AVDD + 0.3 V
Digital Output Voltage to DGND . . . –0.3 V to DVDD + 0.3 V
Operating Temperature Range
Commercial (A Version) . . . . . . . . . . . . . . . –40°C to +85°C
Extended (S Version) . . . . . . . . . . . . . . . . . –55°C to +125°C
Storage Temperature Range . . . . . . . . . . . . . –65°C to +150°C
Junction Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . 150°C
PDIP Package, Power Dissipation . . . . . . . . . . . . . . . . 450 mW
␪JAThermal Impedance . . . . . . . . . . . . . . . . . . . . . . 105°C/W
Lead Temperature, Soldering (10 sec) . . . . . . . . . . . . 260°C
CERDIP Package, Power Dissipation . . . . . . . . . . . . . 450 mW
␪JAThermal Impedance . . . . . . . . . . . . . . . . . . . . . . . 70°C/W
Lead Temperature, Soldering . . . . . . . . . . . . . . . . . . 300°C
SOIC Package, Power Dissipation . . . . . . . . . . . . . . . . 450 mW
␪JAThermal Impedance . . . . . . . . . . . . . . . . . . . . . . . 75°C/W
Lead Temperature, Soldering
Vapor Phase (60 sec) . . . . . . . . . . . . . . . . . . . . . . . 215°C
Infrared (15 secs) . . . . . . . . . . . . . . . . . . . . . . . . . . 220°C
Power Dissipation (Any Package) to 75°C . . . . . . . . . . 450 mW
Model
Temperature
Range
Package Option*
AD7713AN
AD7713AR
AD7713AR-REEL
AD7713AR-REEL7
AD7713AQ
AD7713SQ
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
–55°C to +125°C
N-24
RW-24
RW-24
RW-24
Q-24
Q-24
*N = PDIP; Q = CERDIP; RW = SOIC.
*Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those listed in the operational
sections of the specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability.
1.6mA
2.1V
TO OUTPUT PIN
100pF
200␮A
Figure 1. Load Circuit for Access Time and Bus Relinquish Time
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although the
AD7713 features proprietary ESD protection circuitry, permanent damage may occur on devices
subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended
to avoid performance degradation or loss of functionality.
–6–
REV. D
AD7713
PIN CONFIGURATION
PDIP, CERDIP, AND SOIC
SCLK 1
24
DGND
MCLK IN 2
23
DVDD
MCLK OUT 3
22
SDATA
A0 4
21
DRDY
SYNC 5
20
RFS
AD7713
TOP VIEW 19 TFS
(Not to Scale)
18 AGND
AIN1(+) 7
MODE 6
AIN1(–) 8
17
AIN3
AIN2(+) 9
16
RTD2
AIN2(–) 10
15
REF IN(+)
STANDBY 11
14
REF IN(–)
AVDD 12
13
RTD1
PIN FUNCTION DESCRIPTION
Pin No.
Mnemonic
Function
1
SCLK
Serial Clock. Logic input/output, depending on the status of the MODE pin. When MODE is high, the
device is in its self-clocking mode, and the SCLK pin provides a serial clock output. This SCLK becomes active when RFS or TFS goes low, and it goes high impedance when either RFS or TFS returns
high or when the device has completed transmission of an output word. When MODE is low, the device
is in its external clocking mode and the SCLK pin acts as an input. This input serial clock can be a continuous clock with all data transmitted in a continuous train of pulses. Alternatively, it can be a
noncontinuous clock with the information being transmitted to the AD7713 in smaller batches of data.
2
MCLK IN
Master Clock Signal for the Device. This can be provided in the form of a crystal or external clock. A
crystal can be tied across the MCLK IN and MCLK OUT pins. Alternatively, the MCLK IN pin can be
driven with a CMOS-compatible clock and MCLK OUT left unconnected. The clock input frequency is
nominally 2 MHz.
3
MCLK OUT
When the master clock for the device is a crystal, the crystal is connected between MCLK IN and MCLK OUT.
4
A0
Address Input. With this input low, reading and writing to the device is to the control register. With
this input high, access is to either the data register or the calibration registers.
5
SYNC
Logic Input. Allows for synchronization of the digital filters when using a number of AD7713s. It
resets the nodes of the digital filter.
6
MODE
Logic Input. When this pin is high, the device is in its self-clocking mode. With this pin low, the
device is in its external clocking mode.
7
AIN1(+)
Analog Input Channel 1. Positive input of the programmable gain differential analog input. The
AIN1(+) input is connected to an output current source that can be used to check that an external
transducer has burnt out or gone open circuit. This output current source can be turned on/off via the
control register.
8
AIN1(–)
Analog Input Channel 1. Negative input of the programmable gain differential analog input.
9
AIN2(+)
Analog Input Channel 2. Positive input of the programmable gain differential analog input.
10
AIN2(–)
Analog Input Channel 2. Negative input of the programmable gain differential analog input.
11
STANDBY
Logic Input. Taking this pin low shuts down the internal analog and digital circuitry, reducing power
consumption to less than 100 µW.
12
AVDD
Analog Positive Supply Voltage, 5 V to 10 V.
13
RTD1
Constant Current Output. A nominal 200 µA constant current is provided at this pin, which can be
used as the excitation current for RTDs. This current can be turned on or off via the control register.
14
REF IN(–)
Reference Input. The REF IN(–) can lie anywhere between AVDD and AGND, provided REF IN(+) is
greater than REF IN(–).
15
REF IN(+)
Reference Input. The reference input is differential providing that REF IN(+) is greater than REF
IN(–). REF IN(+) can lie anywhere between AVDD and AGND.
REV. D
–7–
AD7713
Pin No. Mnemonic Function
16
RTD2
Constant Current Output. A nominal 200 µA constant current is provided at this pin, which can be used as
the excitation current for RTDs. This current can be turned on or off via the control register. This second
current can be used to eliminate lead resistanced errors in 3-wire RTD configurations.
17
AIN3
Analog Input Channel 3. High level analog input that accepts an analog input voltage range of 4 ⫻ VREF/GAIN.
At the nominal VREF of 2.5 V and a gain of 1, the AIN3 input voltage range is 0 V to ± 10 V.
18
AGND
Ground Reference Point for Analog Circuitry.
19
TFS
Transmit Frame Synchronization. Active low logic input used to write serial data to the device with serial data
expected after the falling edge of this pulse. In the self-clocking mode, the serial clock becomes active after TFS
goes low. In the external clocking mode, TFS must go low before the first bit of the data-word is written to the part.
20
RFS
Receive Frame Synchronization. Active low logic input used to access serial data from the device. In the selfclocking mode, both the SCLK and SDATA lines become active after RFS goes low. In the external clocking
mode, the SDATA line becomes active after RFS goes low.
21
DRDY
Logic Output. A falling edge indicates that a new output word is available for transmission. The DRDY pin
will return high upon completion of transmission of a full output word. DRDY is also used to indicate when
the AD7713 has completed its on-chip calibration sequence.
22
SDATA
Serial Data. Input/output with serial data being written to either the control register or the calibration registers and serial data being accessed from the control register, calibration registers, or the data register. During
an output data read operation, serial data becomes active after RFS goes low (provided DRDY is low). During a write operation, valid serial data is expected on the rising edges of SCLK when TFS is low. The output
data coding is natural binary for unipolar inputs and offset binary for bipolar inputs.
23
DVDD
Digital Supply Voltage, 5 V. DVDD should not exceed AVDD by more than 0.3 V in normal operation.
24
DGND
Ground Reference Point for Digital Circuitry.
TERMINOLOGY
Integral Nonlinearity
Positive Full-Scale Overrange
Positive full-scale overrange is the amount of overhead available
to handle input voltages on AIN1(+) and AIN2(+) inputs
greater than (AIN1(–) + VREF/GAIN) or on AIN3 of greater
than 4 ⫻ VREF/GAIN (for example, noise peaks or excess voltages
due to system gain errors in system calibration routines) without
introducing errors due to overloading the analog modulator or
to overflowing the digital filter.
This is the maximum deviation of any code from a straight line
passing through the endpoints of the transfer function. The
endpoints of the transfer function are zero scale (not to be confused with bipolar zero), a point 0.5 LSB below the first code
transition (000...000 to 000...001) and full scale, a point 0.5 LSB
above the last code transition (111...110 to 111...111). The error
is expressed as a percentage of full scale.
Negative Full-Scale Overrange
Positive Full-Scale Error
This is the amount of overhead available to handle voltages on
AIN1(+) and AIN2(+) below (AIN1(–) – VREF/GAIN) without
overloading the analog modulator or overflowing the digital filter.
Positive full-scale error is the deviation of the last code transition
(111...110 to 111...111) from the ideal input full-scale voltage.
For AIN1(+) and AIN2(+), the ideal full-scale input voltage is
(AIN1(–) + VREF/GAIN – 3/2 LSBs), where AIN(–) is either
AIN1(–) or AIN2(–) as appropriate; for AIN3, the ideal full-scale
voltage is 4 ⫻ VREF/GAIN – 3/2 LSBs. Positive full-scale error
applies to both unipolar and bipolar analog input ranges.
Offset Calibration Range
In the system calibration modes, the AD7713 calibrates its offset
with respect to the analog input. The offset calibration range
specification defines the range of voltages that the AD7713 can
accept and still calibrate offset accurately.
Unipolar Offset Error
Unipolar offset error is the deviation of the first code transition
from the ideal voltage. For AIN1(+) and AIN2(+), the ideal
input voltage is (AIN1(–) + 0.5 LSB); for AIN3, the ideal input
is 0.5 LSB when operating in the unipolar mode.
Full-Scale Calibration Range
Bipolar Zero Error
In system calibration schemes, two voltages applied in sequence
to the AD7713’s analog input define the analog input range. The
input span specification defines the minimum and maximum
input voltages from zero to full scale that the AD7713 can accept
and still calibrate gain accurately.
This is the range of voltages that the AD7713 can accept in the
system calibration mode and still calibrate full scale correctly.
Input Span
This is the deviation of the midscale transition (0111 ... 111 to
1000 ... 000) from the ideal input voltage. For AIN1(+) and
AIN2(+), the ideal input voltage is (AIN1(–) – 0.5 LSB); AIN3
can accommodate only unipolar input ranges.
Bipolar Negative Full-Scale Error
This is the deviation of the first code transition from the ideal
input voltage. For AIN1(+) and AIN2(+), the ideal input voltage is (AIN1(–) – VREF/GAIN + 0.5 LSB); AIN3 can only
accommodate unipolar input ranges.
–8–
REV. D
AD7713
control register. In other words, it is not possible to write just
the first 12 bits of data into the control register. If more than 24
clock pulses are provided before TFS returns high, then all clock
pulses after the 24th clock pulse are ignored. Similarly, a read
operation from the control register should access 24 bits of data.
CONTROL REGISTER (24 BITS)
A write to the device with the A0 input low writes data to the
control register. A read to the device with the A0 input low
accesses the contents of the control register. The control register
is 24 bits wide. When writing to the register, 24 bits of data
must be written; otherwise, the data will not be loaded to the
MSB
MD2
MD1
MD0
G2
G1
G0
CH1
CH0
WL
RO
BO
B/U
FS11
FS10
FS9
FS8
FS7
FS6
FS5
FS4
FS3
FS2
FS1
FS0
LSB
Operating Mode
MD2
MD1
MD0
Operating Mode
0
0
0
Normal Mode. This is the normal mode of operation of the device whereby a read to the device with A0 high
accesses data from the data register. This is the default condition of these bits after the internal power-on reset.
0
0
1
Activate Self-Calibration. This activates self-calibration on the channel selected by CH0 and CH1. This is
a 1-step calibration sequence, and when complete, the part returns to normal mode (with MD2, MD1,
MD0 of the control registers returning to 0, 0, 0). The DRDY output indicates when this self-calibration
is complete. For this calibration type, the zero-scale calibration is done internally on shorted (zeroed)
inputs, and the full-scale calibration is done on VREF.
0
1
0
Activate System Calibration. This activates system calibration on the channel selected by CH0 and CH1.
This is a 2-step calibration sequence, with the zero-scale calibration done first on the selected input
channel and DRDY indicating when this zero-scale calibration is complete. The part returns to normal
mode at the end of this first step in the 2-step sequence.
0
1
1
Activate System Calibration. This is the second step of the system calibration sequence with full-scale
calibration being performed on the selected input channel. Once again, DRDY indicates when the fullscale calibration is complete. When this calibration is complete, the part returns to normal mode.
1
0
0
Activate System Offset Calibration. This activates system offset calibration on the channel selected by CH0
and CH1. This is a 1-step calibration sequence and, when complete, the part returns to normal mode with
DRDY indicating when this system offset calibration is complete. For this calibration type, the zero-scale
calibration is done on the selected input channel, and the full-scale calibration is done internally on VREF.
1
0
1
Activate Background Calibration. This activates background calibration on the channel selected by CH0 and
CH1. If the background calibration mode is on, the AD7713 provides continuous self-calibration of the reference and shorted (zeroed) inputs. This calibration takes place as part of the conversion sequence, extending
the conversion time and reducing the word rate by a factor of 6. Its major advantage is that the user does
not have to worry about recalibrating the device when there is a change in the ambient temperature. In
this mode, the shorted (zeroed) inputs and VREF, as well as the analog input voltage, are continuously
monitored, and the calibration registers of the device are updated.
1
1
0
Read/Write Zero-Scale Calibration Coefficients. A read to the device with A0 high accesses the contents of
the zero-scale calibration coefficients of the channel selected by CH0 and CH1. A write to the device with
A0 high writes data to the zero-scale calibration coefficients of the channel selected by CH0 and CH1.
The word length for reading and writing these coefficients is 24 bits, regardless of the status of the WL bit
of the control register. Therefore, when writing to the calibration register, 24 bits of data must be written;
otherwise, the new data will not be transferred to the calibration register.
1
1
1
Read/Write Full-Scale Calibration Coefficients. A read to the device with A0 high accesses the contents of
the full-scale calibration coefficients of the channel selected by CH0 and CH1. A write to the device with
A0 high writes data to the full-scale calibration coefficients of the channel selected by CH0 and CH1. The
word length for reading and writing these coefficients is 24 bits, regardless of the status of the WL bit of
the control register. Therefore, when writing to the calibration register, 24 bits of data must be written;
otherwise, the new data will not be transferred to the calibration register.
REV. D
–9–
AD7713
PGA Gain
G2 Gl G0 Gain
0
0 0
1
(Default Condition after the Internal
Power-On Reset)
0
0 1
2
0
1 0
4
0
1 1
8
1
0 0
16
1
0 1
32
1
1 0
64
1
1 1
128
Channel Selection
CH1 CH0 Channel
0
0
AIN1
(Default Condition after the Internal
Power-On Reset)
0
1
AIN2
1
0
AIN3
Word Length
WL Output Word Length
0
16-Bit
(Default Condition after the Internal
Power-On Reset)
1
24-Bit
RTD Excitation Currents
RO
0
Off
(Default Condition after the Internal
Power-On Reset)
1
On
Burn-Out Current
BO
0
Off
(Default Condition after the Internal
Power-On Reset)
1
On
Bipolar/Unipolar Selection (Both Inputs)
B/U
0
Bipolar
(Default Condition after the Internal
Power-On Reset)
1
Unipolar
Filter Selection (FS11 to FS0)
The on-chip digital filter provides a sinc3 (or (sinx/x)3) filter
response. The 12 bits of data programmed into these bits determine the filter cutoff frequency, the position of the first notch of
the filter, and the data rate for the part. In association with the
gain selection, it also determines the output noise (and therefore
the effective resolution) of the device.
The first notch of the filter occurs at a frequency determined by
the relationship: filter first notch frequency = (fCLK IN/512)/code
where code is the decimal equivalent of the code in Bits FS0 to
FS11 and is in the range 19 to 2,000. With the nominal fCLK IN
of 2 MHz, this results in a first notch frequency range from
1.952 Hz to 205.59 kHz. To ensure correct operation of the
AD7713, the value of the code loaded to these bits must be
within this range. Failure to do this will result in unspecified
operation of the device.
Changing the filter notch frequency, as well as the selected gain,
impacts resolution. Tables I and II and Figures 2a and 2b show
the effect of the filter notch frequency and gain on the effective
resolution of the AD7713. The output data rate (or effective
conversion time) for the device is equal to the frequency selected for the first notch of the filter. For example, if the first
notch of the filter is selected at 10 Hz, then a new word is available at a 10 Hz rate or every 100 ms. If the first notch is at 200 Hz,
a new word is available every 5 ms.
The settling time of the filter to a full-scale step input change is
worst case 4 ⫻ 1/(Output Data Rate). This settling time is to 100%
of the final value. For example, with the first filter notch at 100 Hz,
the settling time of the filter to a full-scale step input change is
400 ms max. If the first notch is at 200 Hz, the settling time of
the filter to a full-scale input step is 20 ms max. This settling time
can be reduced to 3 ⫻ l/(Output Data Rate) by synchronizing the
step input change to a reset of the digital filter. In other words, if
the step input takes place with SYNC low, the settling time will
be 3 ⫻ l/(Output Data Rate). If a change of channels takes place,
the settling time is 3 ⫻ l/(Output Data Rate) regardless of the
SYNC input.
The –3 dB frequency is determined by the programmed first
notch frequency according to the relationship:
Filter − 3 dB Frequency = 0.262 × First Notch Frequency
–10–
REV. D
AD7713
Tables I and II show the output rms noise for some typical
notch and –3 dB frequencies. The numbers given are for the
bipolar input ranges with a VREF of 2.5 V. These numbers are
typical and are generated with an analog input voltage of 0 V.
The output noise from the part comes from two sources. First,
there is the electrical noise in the semiconductor devices used in
the implementation of the modulator (device noise). Second,
when the analog input signal is converted into the digital domain,
quantization noise is added. The device noise is at a low level
and is largely independent of frequency. The quantization noise
starts at an even lower level but rises rapidly with increasing
frequency to become the dominant noise source. Consequently,
lower filter notch settings (below 12 Hz approximately) tend to
be device noise dominated while higher notch settings are dominated by quantization noise. Changing the filter notch and
cutoff frequency in the quantization noise dominated region
results in a more dramatic improvement in noise performance
than it does in the device noise dominated region as shown in
Table I. Furthermore, quantization noise is added after the
PGA, so effective resolution is independent of gain for the
higher filter notch frequencies. Meanwhile, device noise is
added in the PGA and, therefore, effective resolution suffers a
little at high gains for lower notch frequencies.
At the lower filter notch settings (below 12 Hz), the no missing
codes performance of the device is at the 24-bit level. At the
higher settings, more codes will be missed until at 200 Hz notch
setting, no missing codes performance is guaranteed only to the
12-bit level. However, since the effective resolution of the part
is 10.5 bits for this filter notch setting; this no missing codes
performance should be more than adequate for all applications.
The effective resolution of the device is defined as the ratio of the
output rms noise to the input full scale. This does not remain
constant with increasing gain or with increasing bandwidth.
Table II is the same as Table I except that the output is expressed
in terms of effective resolution (the magnitude of the rms noise
with respect to 2 ⫻ VREF/GAIN, i.e., the input full scale). It is
possible to do post filtering on the device to improve the output
data rate for a given –3 dB frequency and also to further reduce
the output noise (see the Digital Filtering section).
Table I. Output Noise vs. Gain and First Notch Frequency
First Notch of
Typical Output RMS Noise (µV)
Filter and O/P –3 dB
1
Data Rate
Frequency Gain of 1 Gain of 2 Gain of 4 Gain of 8 Gain of 16 Gain of 32
2
2 Hz
5 Hz2
6 Hz2
10 Hz2
12 Hz2
20 Hz3
50 Hz3
100 Hz3
200 Hz3
0.52 Hz
1.31 Hz
1.57 Hz
2.62 Hz
3.14 Hz
5.24 Hz
13.1 Hz
26.2 Hz
52.4 Hz
1.0
1.8
2.5
4.33
5.28
13
130
0.6 ⫻ 103
3.1 ⫻ 103
0.78
1.1
1.31
2.06
2.36
6.4
75
0.26 ⫻ 103
1.6 ⫻ 103
0.48
0.63
0.84
1.2
1.33
3.7
25
140
0.7 ⫻ 103
0.33
0.5
0.57
0.64
0.87
1.8
12
70
0.29 ⫻ 103
0.25
0.44
0.46
0.54
0.63
1.1
7.5
35
180
0.25
0.41
0.43
0.46
0.62
0.9
4
25
120
Gain of 64 Gain of 128
0.25
0.38
0.4
0.46
0.6
0.65
2.7
15
70
0.25
0.38
0.4
0.46
0.56
0.65
1.7
8
40
NOTES
1
The default condition (after the internal power-on reset) for the first notch of filter is 60 Hz.
2
For these filter notch frequencies, the output rms noise is primarily dominated by device noise, and, as a result, is independent of the value of the reference voltage.
Therefore, increasing the reference voltage will give an increase in the effective resolution of the device (i.e., the ratio of the rms noise to the input full scale is
increased since the output rms noise remains constant as the input full scale increases).
3
For these filter notch frequencies, the output rms noise is dominated by quantization noise, and, as a result, is proportional to the value of the reference voltage.
Table II. Effective Resolution vs. Gain and First Notch Frequency
First Notch of
Effective Resolution* (Bits)
Filter and O/P –3 dB
Data Rate
Frequency Gain of 1 Gain of 2 Gain of 4 Gain of 8 Gain of 16 Gain of 32
Gain of 64 Gain of 128
2 Hz
5 Hz
6 Hz
10 Hz
12 Hz
20 Hz
50 Hz
100 Hz
200 Hz
18.5
17.5
17.5
17.5
17
17
15
12.5
10
0.52 Hz
1.31 Hz
1.57 Hz
2.62 Hz
3.14 Hz
5.24 Hz
13.1 Hz
26.2 Hz
52.4 Hz
22.5
21.5
21
20
20
18.5
15
13
10.5
21.5
21
21
20
20
18.5
15
13
10.5
21.5
21
20.5
20
20
18.5
15.5
13
11
21
20
20
19.5
19.5
18.5
15.5
13
11
20.5
19.5
19.5
19
19
18
15.5
13
11
19.5
18.5
18.5
18.5
18
17.5
15.5
12.5
10.5
17.5
16.5
16.5
16.5
16
16
14.5
12.5
10
*Effective resolution is defined as the magnitude of the output rms noise with respect to the input full scale (i.e., 2 ⫻ VREF/GAIN). Table II applies for a V REF of 2.5 V
and resolution numbers are rounded to the nearest 0.5 LSB.
REV. D
–11–
AD7713
Figures 2a and 2b gives similar information to that outlined in
Table I. In this plot, the output rms noise is shown for the full
range of available cutoff frequencies rather than for some typical
cutoff frequencies as in Tables I and II. The numbers given in
these plots are typical values at 25°C.
10000.0
GAIN OF 1
GAIN OF 2
OUTPUT NOISE (␮V)
1000.0
GAIN OF 4
GAIN OF 8
100.0
10.0
The basic connection diagram for the part is shown in Figure 3.
This shows the AD7713 in the external clocking mode with
both the AVDD and DVDD pins of the AD7713 being driven
from the analog 5 V supply. Some applications will have separate supplies for both AVDD and DVDD, and in some of these
cases, the analog supply will exceed the 5 V digital supply (see the
Power Supplies and Grounding section).
1.0
0.1
10
100
1k
NOTCH FREQUENCY (Hz)
the frequency of the master clock, MCLK IN, and the selected
gain (see Table III). A charge balancing ADC (⌺-⌬ modulator)
converts the sampled signal into a digital pulse train whose duty
cycle contains the digital information. The programmable gain
function on the analog input is also incorporated in this ⌺-⌬
modulator with the input sampling frequency being modified to
give the higher gains. A sinc3 digital low-pass filter processes the
output of the ⌺-⌬ modulator and updates the output register at
a rate determined by the first notch frequency of this filter. The
output data can be read from the serial port randomly or periodically at any rate up to the output register update rate. The
first notch of this digital filter (and therefore its –3 dB frequency)
can be programmed via an on-chip control register. The
programmable range for this first notch frequency is from
1.952 Hz to 205.59 Hz, giving a programmable range for the
–3 dB frequency of 0.52 Hz to 53.9 Hz.
10k
Figure 2a. Plot of Output Noise vs. Gain and Notch
Frequency (Gains of 1 to 8)
ANALOG 5V
SUPPLY
1000.0
10␮F 0.1␮F
GAIN OF 16
GAIN OF 32
OUTPUT NOISE (␮V)
100.0
GAIN OF 64
GAIN OF 128
10.0
DIFFERENTIAL
ANALOG INPUT
AIN1(+)
DIFFERENTIAL
ANALOG INPUT
AIN2(+)
AVDD
DVDD
AIN1(–)
TFS
RFS
AIN2(–)
SINGLE-ENDED
ANALOG INPUT
AIN3
DRDY
AD7713
SDATA
SERIAL
DATA
SCLK
SERIAL
CLOCK
DVDD
STANDBY
1.0
0.1
10
100
1k
NOTCH FREQUENCY (Hz)
10k
ANALOG
GROUND
AGND
A0
DIGITAL
GROUND
DGND
MODE
REF IN(+)
SYNC
2.5V
REFERENCE
Figure 2b. Plot of Output Noise vs. Gain and Notch
Frequency (Gains of 16 to 128)
DATA
READY
TRANSMIT
(WRITE)
RECEIVE
(READ)
ADDRESS
INPUT
DVDD
MCLK IN
REF IN(–)
MCLK OUT
CIRCUIT DESCRIPTION
The AD7713 is a ⌺-⌬ ADC with on-chip digital filtering, intended
for the measurement of wide dynamic range, low frequency signals,
such as those in industrial control or process control applications. It
contains a ⌺-⌬ (or charge balancing) ADC, a calibration
microcontroller with on-chip static RAM, a clock oscillator, a
digital filter, and a bidirectional serial communications port.
The part contains three analog input channels, two programmable gain differential input channels, and one programmable
gain high-level single-ended input channel. The gain range on
both inputs is from 1 to 128. For the AIN1 and AIN2 inputs,
this means that the input can accept unipolar signals of between
0 mV to 20 mV and 0 V to 2.5 V or bipolar signals in the range
from ± 20 mV to ± 2.5 V when the reference input voltage equals
2.5 V. The input voltage range for the AIN3 input is 4 ⫻ VREF/
GAIN and is 0 V to 10 V with the nominal reference of 2.5 V and
a ANALOG gain of 1. The input signal to the selected analog
input channel is continuously sampled at a rate determined by
Figure 3. Basic Connection Diagram
The AD7713 provides a number of calibration options that can
be programmed via the on-chip control register. A calibration
cycle can be initiated at any time by writing to this control register. The part can perform self-calibration using the on-chip
calibration microcontroller and SRAM to store calibration
parameters. Other system components may also be included in
the calibration loop to remove offset and gain errors in the input
channel using the system calibration mode. Another option is a
background calibration mode where the part continuously
performs self-calibration and updates the calibration coefficients. Once the part is in this mode, the user does not have to
worry about issuing periodic calibration commands to the device
or asking the device to recalibrate when there is a change in the
ambient temperature or power supply voltage.
–12–
REV. D
AD7713
The AD7713 gives the user access to the on-chip calibration
registers, allowing the microprocessor to read the device’s calibration coefficients and also to write its own calibration coefficients
to the part from prestored values in E2PROM. This gives the
microprocessor much greater control over the AD7713’s calibration procedure. It also means that the user can verify that the
device has performed its calibration correctly by comparing the
coefficients after calibration with prestored values in E2PROM.
⌺-⌬ ADCs are generally described by the order of the analog
low-pass filter. A simple example of a first-order ⌺-⌬ ADC is
shown in Figure 5. This contains only a first-order low-pass
filter or integrator. It also illustrates the derivation of the alternative name for these devices: charge balancing ADCs.
DIFFERENTIAL
AMPLIFIER
For battery-operated or low power systems, the AD7713 offers
a standby mode (controlled by the STANDBY pin) that reduces
idle power consumption to typically 150 µW.
COMPARATOR
+FS
DAC
THEORY OF OPERATION
–FS
The general block diagram of a ⌺-⌬ ADC is shown in Figure 4.
It contains the following elements:
Figure 5. Basic Charge-Balancing ADC
It consists of a differential amplifier (whose output is the difference between the analog input and the output of a 1-bit DAC),
an integrator, and a comparator. The term charge balancing comes
from the fact that this system is a negative feedback loop that tries
to keep the net charge on the integrator capacitor at 0 by balancing charge injected by the input voltage with charge injected by
the 1-bit DAC. When the analog input is 0, the only contribution to the integrator output comes from the 1-bit DAC. For the
net charge on the integrator capacitor to be 0, the DAC output
must spend half its time at +FS and half its time at –FS. Assuming ideal components, the duty cycle of the comparator will be 50%.
• A sample-hold amplifier
• A differential amplifier or subtracter
• An analog low-pass filter
• A 1-bit ADC (comparator)
• A 1-bit DAC
S/H AMP
COMPARATOR
ANALOG
LOW-PASS
FILTER
DIGITAL
FILTER
DAC
DIGITAL DATA
Figure 4. General ⌺-⌬ ADC
In operation, the analog signal sample is fed to the subtracter,
along with the output of the 1-bit DAC. The filtered difference
signal is fed to the comparator, whose output samples the difference signal at a frequency many times that of the analog signal
sampling frequency (oversampling).
Oversampling is fundamental to the operation of ⌺-⌬ ADCs.
Using the quantization noise formula for an ADC
When a positive analog input is applied, the output of the 1-bit
DAC must spend a larger proportion of the time at +FS, so the
duty cycle of the comparator increases. When a negative input
voltage is applied, the duty cycle decreases.
The AD7713 uses a second-order ⌺-⌬ modulator and a digital
filter that provides a rolling average of the sampled output.
After power-up or if there is a step change in the input voltage,
there is a settling time that must elapse before valid data is
obtained.
Input Sample Rate
SNR = (6.02 × Number of Bits + 1.76) dB
a 1-bit ADC or comparator yields an SNR of 7.78 dB.
The AD7713 samples the input signal at a frequency of 7.8 kHz
or greater (see Table III). As a result, the quantization noise is
spread over a much wider frequency than that of the band of
interest. The noise in the band of interest is reduced still further by analog filtering in the modulator loop, which shapes
the quantization noise spectrum to move most of the noise
energy to frequencies outside the bandwidth of interest. The
noise performance is thus improved from this 1-bit level to the
performance outlined in Tables I and II and in Figures 2a and 2b.
The output of the comparator provides the digital input for the
1-bit DAC, so that the system functions as a negative feedback
loop that tries to minimize the difference signal. The digital data
that represents the analog input voltage is contained in the duty
cycle of the pulse train appearing at the output of the comparator. It can be retrieved as a parallel binary data-word using a
digital filter.
REV. D
INTEGRATOR
VIN
The modulator sample frequency for the device remains at
fCLK IN/512 (3.9 kHz @ fCLK IN = 2 MHz) regardless of the
selected gain. However, gains greater than ⫻1 are achieved by a
combination of multiple input samples per modulator cycle and
a scaling of the ratio of the reference capacitor to input capacitor. As a result of the multiple sampling, the input the sample
rate of the device varies with the selected gain (see Table III).
The effective input impedance is 1/C ⫻ fS, where C is the input
sampling capacitance and fS is the input sample rate.
Table III. Input Sampling Frequency vs. Gain
Gain
Input Sampling Frequency (fS)
1
2
4
8
16
32
64
128
fCLK IN/256 (7.8 kHz @ fCLK IN = 2 MHz)
2 ⫻ fCLK IN/256 (15.6 kHz @ fCLK IN = 2 MHz)
4 ⫻ fCLK IN/256 (31.2 kHz @ fCLK IN = 2 MHz)
8 ⫻ fCLK IN/256 (62.4 kHz @ fCLK IN = 2 MHz)
8 ⫻ fCLK IN/256 (62.4 kHz @ fCLK IN = 2 MHz)
8 ⫻ fCLK IN/256 (62.4 kHz @ fCLK IN = 2 MHz)
8 ⫻ fCLK IN/256 (62.4 kHz @ fCLK IN = 2 MHz)
8 ⫻ fCLK IN/256 (62.4 kHz @ fCLK IN = 2 MHz)
–13–
AD7713
DIGITAL FILTERING
Post Filtering
The AD7713’s digital filter behaves like a similar analog filter,
with a few minor differences.
The on-chip modulator provides samples at a 3.9 kHz output
rate. The on-chip digital filter decimates these samples to
provide data at an output rate that corresponds to the programmed first notch frequency of the filter. Since the output
data rate exceeds the Nyquist criterion, the output rate for a
given bandwidth will satisfy most application requirements.
However, there may be some applications that require a higher
data rate for a given bandwidth and noise performance. Applications that need this higher data rate will require some post
filtering following the digital filter of the AD7713.
First, since digital filtering occurs after the A-to-D conversion
process, it can remove noise injected during the conversion
process. Analog filtering cannot do this.
On the other hand, analog filtering can remove noise superimposed
on the analog signal before it reaches the ADC. Digital filtering
cannot do this, and noise peaks riding on signals near full scale
have the potential to saturate the analog modulator and digital
filter, even though the average value of the signal is within limits.
To alleviate this problem, the AD7713 has overrange headroom
built into the ⌺-⌬ modulator and digital filter, which allows overrange excursions of 5% above the analog input range. If noise
signals are larger than this, consideration should be given to analog
input filtering or to reducing the input channel voltage so that its
full scale is half that of the analog input channel full scale. This will
provide an overrange capability greater than 100% at the expense
of reducing the dynamic range by 1 bit (50%).
Filter Characteristics
The cutoff frequency of the digital filter is determined by the value
loaded to Bits FS0 to FS11 in the control register. At the maximum clock frequency of 2 MHz, the minimum cutoff frequency of
the filter is 0.52 Hz, while the maximum programmable cutoff
frequency is 53.9 Hz.
Figure 6 shows the filter frequency response for a cutoff frequency
of 0.52 Hz, which corresponds to a first filter notch frequency of
2 Hz. This is a (sinx/x)3 response (also called sinc3) that provides
>100 dB of 50 Hz and 60 Hz rejection. Programming a different cutoff frequency via FS0 to FS11 does not alter the profile
of the filter response; it changes the frequency of the notches as
outlined in the Control Register section.
0
–20
–40
–60
GAIN (dB)
–80
–100
–120
–140
–160
–180
–200
–220
–240
0
2
4
6
8
FREQUENCY (Hz)
10
12
Figure 6. Frequency Response of AD7713 Filter
For example, if the required bandwidth is 1.57 Hz but the required
update rate is 20 Hz, the data can be taken from the AD7713 at
the 20 Hz rate giving a –3 dB bandwidth of 5.24 Hz. Post filtering
can be applied to this to reduce the bandwidth and output noise,
to the 1.57 Hz bandwidth level, while maintaining an output rate
of 20 Hz.
Post filtering can also be used to reduce the output noise from
the device for bandwidths below 0.52 Hz. At a gain of 128, the
output rms noise is 250 nV. This is essentially device noise or
white noise, and since the input is chopped, the noise has a flat
frequency response. By reducing the bandwidth below 0.52 Hz,
the noise in the resultant pass band can be reduced. A reduction
in bandwidth by a factor of 2 results in a √2 reduction in the
output rms noise. This additional filtering will result in a longer
settling time.
Antialias Considerations
The digital filter does not provide any rejection at integer
multiples of the modulator sample frequency (n ⫻ 3.9 kHz,
where n = 1, 2, 3...). This means that there are frequency
bands, ± f3 dB wide (f3 dB is cutoff frequency selected by FS0
to FS11), where noise passes unattenuated to the output.
However, due to the AD7713’s high oversampling ratio, these
bands occupy only a small fraction of the spectrum, and most
broadband noise is filtered. In any case, because of the high
oversampling ratio, a simple, RC, single-pole filter is generally
sufficient to attenuate the signals in these bands on the analog
input and thus provide adequate antialiasing filtering.
If passive components are placed in front of the AIN1 and
AIN2 inputs of the AD7713, care must be taken to ensure that
the source impedance is low enough so as not to introduce
gain errors in the system. The dc input impedance for the
AIN1 and AIN2 inputs is over 1 GΩ. The input appears as a
dynamic load that varies with the clock frequency and with the
selected gain (see Figure 7). The input sample rate, as shown
in Table III, determines the time allowed for the analog input
capacitor, CIN, to be charged. External impedances result in a
longer charge time for this capacitor, which result in gain errors being introduced on the analog inputs. Both inputs of the
differential input channels look into similar input circuitry.
Since the AD7713 contains this on-chip, low-pass filtering,
there is a settling time associated with step function inputs, and
data on the output will be invalid after a step change until the
settling time has elapsed. The settling time depends upon the
notch frequency chosen for the filter. The output data rate
equates to this filter notch frequency, and the settling time of
the filter to a full-scale step input is four times the output data
period. In applications using both input channels, the settling
time of the filter must be allowed to elapse before data from the
second channel is accessed.
AIN
RINT
(7k⍀ TYP)
CINT
(11.5pF TYP)
VBIAS
HIGH
IMPEDANCE
> 1G⍀
SWITCHING FREQUENCY DEPENDS ON
fCLKIN AND SELECTED GAIN
Figure 7. AIN1, AIN2 Input Impedance
–14–
REV. D
AD7713
In any case, the error introduced due to longer charging times is
a gain error that can be removed using the system calibration
capabilities of the AD7713 provided that the resultant span is
within the span limits of the system calibration techniques for
the AD7713.
The AIN3 input contains a resistive attenuation network as
outlined in Figure 8. The typical input impedance on this input
is 44 kΩ. As a result, the AIN3 input should be driven from a
low impedance source.
AIN3
33k⍀
11k⍀
MODULATOR
CIRCUIT
VBIAS
Figure 8. AIN3 Input Impedance
ANALOG INPUT FUNCTIONS
Analog Input Ranges
The analog inputs on the AD7713 provide the user with considerable flexibility in terms of analog input voltage ranges. Two of
the inputs are differential, programmable-gain, input channels
that can handle either unipolar or bipolar input signals. The
common-mode range of these inputs is from AGND to AVDD,
provided that the absolute value of the analog input voltage lies
between AGND – 30 mV and AVDD + 30 mV. The third analog
input is a single-ended, programmable gain high-level input that
accepts analog input ranges of 0 to 4 ⫻ VREF/GAIN.
The dc input leakage current on the AIN1 and AIN2 inputs
is 10 pA maximum at 25°C (± 1 nA over temperature). This
results in a dc offset voltage developed across the source
impedance. However, this dc offset effect can be compensated
for by a combination of the differential input capability of the
part and its system calibration mode. The dc input current on
the AIN3 input depends on the input voltage. For the nominal
input voltage range of 10 V, the input current is 225 µA typ.
Burn Out Current
The AIN1(+) input of the AD7713 contains a 1 µA current source
that can be turned on/off via the control register. This current
source can be used in checking that a transducer has not burnt out
or gone open circuit before attempting to take measurements on
that channel. If the current is turned on and is allowed flow into
the transducer and a measurement of the input voltage on the
AIN1 input is taken, it can indicate that the transducer is not functioning correctly. For normal operation, this burn out current is
turned off by writing a 0 to the BO bit in the control register.
RTD Excitation Currents
The AD7713 also contains two matched 200 µA constant current sources which are provided at the RTD1 and RTD2 pins of
the device. These currents can be turned on/off via the control
register. Writing a 1 to the RO bit of the control register enables
these excitation currents.
For 4-wire RTD applications, one of these excitation currents is
used to provide the excitation current for the RTD; the second
current source can be left unconnected. For 3-wire RTD configurations, the second on-chip current source can be used
to eliminate errors due to voltage drops across lead resistances.
Figures 19 and 20 in the Application section show some RTD
configurations with the AD7713.
REV. D
The temperature coefficient of the RTD current sources is
typically 20 ppm/°C with a typical matching between the
temperature coefficients of both current sources of 3 ppm/°C.
For applications where the absolute value of the temperature
coefficient is too large, the following schemes can be used to
remove the drift error.
The conversion result from the AD7713 is ratiometric to the
VREF voltage. Therefore, if the VREF voltage varies with the RTD
temperature coefficient, the temperature drift from the current
source will be removed. For 4-wire RTD applications, the reference voltage can be made ratiometric to the RTD current source
by using the second current with a low TC resistor to generate the
reference voltage for the part. In this case, if a 12.5 kΩ resistor is
used, the 200 µA current source generates 2.5 V across the resistor.
This 2.5 V can be applied to the REF IN(+) input of the AD7713
and the REF IN(–) input at ground will supply a VREF of 2.5 V for
the part. For 3-wire RTD configurations, the reference voltage for
the part is generated by placing a low TC resistor (12.5 kΩ for
2.5 V reference) in series with one of the constant current sources.
The RTD current sources can be driven to within 2 V of AVDD.
The reference input of the AD7713 is differential so the REF IN(+)
and REF IN(–) of the AD7713 are driven from either side of the
resistor. Both schemes ensure that the reference voltage for the part
tracks the RTD current sources over temperature and, thereby,
removes the temperature drift error.
Bipolar/Unipolar Inputs
Two analog inputs on the AD7713 can accept either unipolar or
bipolar input voltage ranges while the third channel accepts only
unipolar signals. Bipolar or unipolar options for AIN1 and AIN2
are chosen by programming the B/U bit of the control register.
This programs both channels for either unipolar or bipolar operation. Programming the part for either unipolar or bipolar operation
does not change any of the input signal conditioning; it simply
changes the data output coding. The data coding is binary for
unipolar inputs and offset binary for bipolar inputs.
The AIN1 and AIN2 input channels are differential, and as a
result, the voltage to which the unipolar and bipolar signals are
referenced is the voltage on the AIN1(–) and AIN2(–) inputs. For
example, if AIN1(–) is 1.25 V and the AD7713 is configured for
unipolar operation with a gain of 1 and a VREF of 2.5 V, the input
voltage range on the AIN1(+) input is 1.25 V to 3.75 V. For the
AIN3 input, the input signals are referenced to AGND.
REFERENCE INPUT
The reference inputs of the AD7713, REF IN(+) and REF IN(–),
provide a differential reference input capability. The commonmode range for these differential inputs is from VSS to AVDD. The
nominal differential voltage, VREF (REF IN(+) – REF IN(–)), is
2.5 V for specified operation, but the reference voltage can go to
5 V with no degradation in performance, provided that the
absolute value of REF IN(+) and REF IN(–) does not exceed
its AVDD and AGND limits. The part is also functional with
VREF voltages down to 1 V, but with degraded performance as the
output noise will, in terms of LSB size, be larger. REF IN(+)
must always be greater than REF IN(–) for correct operation of
the AD7713.
Both reference inputs provide a high impedance, dynamic load
similar to the analog inputs. The maximum dc input leakage current is 10 pA (±1 nA over temperature), and source resistance
may result in gain errors on the part. The reference inputs
–15–
AD7713
look like the AIN1 analog input (see Figure 7). In this case, RINT
is 5 kΩ typ and CINT varies with gain. The input sample rate is
fCLK IN/256 and does not vary with gain. For gains of 1 to 8,
CINT is 20 pF; for a gain of 16, it is 10 pF; for a gain of 32, it is
5 pF; for a gain of 64, it is 2.5 pF; and for a gain of 128, it is
1.25 pF.
The digital filter of the AD7713 removes noise from the reference
input just as it does with the analog input, and the same limitations apply regarding lack of noise rejection at integer multiples of
the sampling frequency. The output noise performance outlined
in Tables I and II assumes a clean reference. If the reference
noise in the bandwidth of interest is excessive, it can degrade the
performance of the AD7713. A recommended reference source
for the AD7713 is the AD680, a 2.5 V reference.
USING THE AD7713 SYSTEM
DESIGN CONSIDERATIONS
The AD7713 operates differently from successive approximation ADCs or integrating ADCs. Since it samples the signal
continuously, like a tracking ADC, there is no need for a start
convert command. The output register is updated at a rate
determined by the first notch of the filter, and the output can be
read at any time, either synchronously or asynchronously.
Clocking
The AD7713 requires a master clock input, which may be an
external TTL/CMOS compatible clock signal applied to the
MCLK IN pin with the MCLK OUT pin left unconnected.
Alternatively, a crystal of the correct frequency can be connected
between MCLK IN and MCLK OUT, in which case the clock
circuit will function as a crystal controlled oscillator. For lower
clock frequencies, a ceramic resonator may be used instead of the
crystal. For these lower frequency oscillators, external capacitors
may be required on either the ceramic resonator or on the crystal.
The input sampling frequency, the modulator sampling frequency,
the –3 dB frequency, output update rate, and calibration time
are all directly related to the master clock frequency, fCLK IN.
Reducing the master clock frequency by a factor of two will halve
the above frequencies and update rate and will double the calibration time.
The current drawn from the DVDD power supply is also directly
related to fCLK IN. Reducing fCLK IN by a factor of two will halve
the DVDD current but will not affect the current drawn from the
AVDD power supply.
System Synchronization
If multiple AD7713s are operated from a common master clock,
they can be synchronized to update their output registers simultaneously. A falling edge on the SYNC input resets the filter
and places the AD7713 into a consistent, known state. A common signal to the AD7713’s SYNC inputs will synchronize their
operation. This would normally be done after each AD7713 has
performed its own calibration or has had calibration coefficients
loaded to it.
The SYNC input can also be used to reset the digital filter in
systems where the turn-on time of the digital power supply
(DVDD) is very long. In such cases, the AD7713 will start operating internally before the DVDD line has reached its minimum
operating level, 4.75 V. With a low DVDD voltage, the AD7713’s
internal digital filter logic does not operate correctly. Thus, the
AD7713 may have clocked itself into an incorrect operating
condition by the time that DVDD has reached its correct level.
The digital filter will be reset upon issue of a calibration,
command (whether it is self-calibration, system calibration or
background calibration) to the AD7713. This ensures correct
operation of the AD7713. In systems where the power-on default
conditions of the AD7713 are acceptable, and no calibration is
performed after power-on, issuing a SYNC pulse to the AD7713
will reset the AD7713’s digital filter logic. An R, C on the SYNC
line, with R, C time constant longer than the DVDD power-on
time, will perform the SYNC function.
Accuracy
⌺-⌬ ADCs, like VFCs and other integrating ADCs, do not contain
any source of nonmonotonicity, and inherently offer no missing
codes performance. The AD7713 achieves excellent linearity by
the use of high quality, on-chip silicon dioxide capacitors, which
have a very low capacitance/voltage coefficient. The device also
achieves low input drift through the use of chopper stabilized techniques in its input stage. To ensure excellent performance over
time and temperature, the AD7713 uses digital calibration techniques that minimize offset and gain error.
Autocalibration
Autocalibration on the AD7713 removes offset and gain
errors from the device. A calibration routine should be initiated on the device whenever there is a change in the ambient
operating temperature or supply voltage. It should also be
initiated if there is a change in the selected gain, filter notch,
or bipolar/unipolar input range. However, if the AD7713 is in
its background calibration mode, the above changes are all
automatically taken care of (after the settling time of the filter
has been allowed for).
The AD7713 offers self-calibration, system calibration, and
background calibration facilities. For calibration to occur on
the selected channel, the on-chip microcontroller must record
the modulator output for two different input conditions. These
are zero-scale and full-scale points. With these readings, the
microcontroller can calculate the gain slope for the input to
output transfer function of the converter. Internally, the part
works with a resolution of 33 bits to determine its conversion
result of either 16 bits or 24 bits.
The AD7713 also provides the facility to write to the on-chip
calibration registers, and, in this manner, the span and offset for
the part can be adjusted by the user. The offset calibration register
contains a value that is subtracted from all conversion results, while
the full-scale calibration register contains a value that is multiplied
by all conversion results. The offset calibration coefficient is subtracted from the result prior to the multiplication by the full-scale
coefficient. In the first three modes outlined here, the DRDY line
indicates that calibration is complete by going low. If DRDY is low
before (or goes low during) the calibration command, it may take
up to one modulator cycle before DRDY goes high to indicate that
calibration is in progress. Therefore, the DRDY line should be
ignored for up to one modulator cycle after the last bit of the calibration command is written to the control register.
Self-Calibration
In the self-calibration mode with a unipolar input range, the
zero-scale point used in determining the calibration coefficients
is with both inputs shorted and the full-scale point is VREF. The
zero-scale coefficient is determined by converting an internal
shorted inputs node. The full-scale coefficient is determined
from the span between this shorted inputs conversion and a
conversion on an internal VREF node. The self-calibration mode
–16–
REV. D
AD7713
is invoked by writing the appropriate values (0, 0, 1) to the
MD2, MD1, and MD0 bits of the control register. In this calibration mode, the shorted inputs node is switched in to the
modulator first and a conversion is performed; the VREF node is
then switched in, and another conversion is performed. When
the calibration sequence is complete, the calibration coefficients
updated, and the filter resettled to the analog input voltage, the
DRDY output goes low. The self-calibration procedure takes
into account the selected gain on the PGA.
System Offset Calibration
For bipolar input ranges in the self-calibrating mode, the sequence
is very similar to that just outlined. In this case, the two points
that the AD7713 calibrates are midscale (bipolar zero) and
positive full scale.
System Calibration
System calibration allows the AD7713 to compensate for system
gain and offset errors as well as its own internal errors. System
calibration performs the same slope factor calculations as selfcalibration but uses voltage values presented by the system to
the AIN inputs for the zero-scale and full-scale points. System
calibration is a 2-step process. The zero-scale point must be
presented to the converter first. It must be applied to the converter
before the calibration step is initiated and remain stable until the
step is complete. System calibration is initiated by writing the
appropriate values (0, 1, 0) to the MD2, MD1, and MD0 bits
of the control register. The DRDY output from the device will
signal when the step is complete by going low. After the zeroscale point is calibrated, the full-scale point is applied and the
second step of the calibration process is initiated by again writing the appropriate values (0, 1, 1) to MD2, MD1, and MD0.
Again, the full-scale voltage must be set up before the calibration is initiated, and it must remain stable throughout the
calibration step. DRDY goes low at the end of this second step
to indicate that the system calibration is complete. In the unipolar mode, the system calibration is performed between the two
endpoints of the transfer function; in the bipolar mode, it is
performed between midscale and positive full scale.
This 2-step system calibration mode offers another feature.
After the sequence has been completed, additional offset or gain
calibrations can be performed by themselves to adjust the zero
reference point or the system gain. This is achieved by performing the first step of the system calibration sequence (by writing
0, 1, 0 to MD2, MD1, and MD0). This will adjust the zeroscale or offset point but will not change the slope factor from
what was set during a full system calibration sequence.
System calibration can also be used to remove any errors from
an antialiasing filter on the analog input. A simple R, C antialiasing filter on the front end may introduce a gain error on the
analog input voltage but the system calibration can be used to
remove this error.
System offset calibration is a variation of both the system calibration and self-calibration. In this case, the zero-scale point
for the system is presented to the AIN input of the converter.
System offset calibration is initiated by writing 1, 0, 0 to MD2,
MD1, and MD0. The system zero-scale coefficient is determined by converting the voltage applied to the AIN input, while
the full-scale coefficient is determined from the span between
this AIN conversion and a conversion on VREF. The zero-scale
point should be applied to the AIN input for the duration of the
calibration sequence. This is a 1-step calibration sequence with
DRDY going low when the sequence is completed. In the unipolar mode, the system offset calibration is performed between
the two endpoints of the transfer function; in the bipolar mode,
it is performed between midscale and positive full scale.
Background Calibration
The AD7713 also offers a background calibration mode where
the part interleaves its calibration procedure with its normal
conversion sequence. In the background calibration mode, the
same voltages are used as the calibration points as are used in
the self-calibration mode, i.e., shorted inputs and VREF. The
background calibration mode is invoked by writing 1, 0, 1 to
MD2, MD1, and MD0 of the control register. When invoked,
the background calibration mode reduces the output data rate of
the AD7713 by a factor of 6 while the –3 dB bandwidth remains
unchanged. Its advantage is that the part is continually performing calibration and automatically updating its calibration
coefficients. As a result, the effects of temperature drift, supply
sensitivity and time drift on zero- and full-scale errors are automatically removed. When the background calibration mode is
turned on, the part will remain in this mode until Bits MD2,
MD1, and MD0 of the control register are changed. With background calibration mode on, the first result from the AD7713
will be incorrect as the full-scale calibration will not have been
performed. For a step change on the input, the second output
update will have settled to 100% of the final value.
Table IV summarizes the calibration modes and the calibration
points associated with them. It also gives the duration from
when the calibration is invoked to when valid data is available to
the user.
Span and Offset Limits
Whenever a system calibration mode is used, there are limits on
the amount of offset and span that can be accommodated. The
range of input span in both the unipolar and bipolar modes for
AIN1 and AIN2 has a minimum value of 0.8 ⫻ VREF/GAIN and
a maximum value of 2.1 ⫻ VREF/GAIN. For AIN3, the minimum value is 3.2 ⫻ VREF/GAIN, while the maximum value is
4.2 ⫻ VREF/GAIN.
Table IV. Calibration Truth Table
Calibration Type
MD2, MD1, MD0
Self-Calibration
System Calibration
System Calibration
System Offset Calibration
Background Calibration
0, 0, 1
0, 1, 0
0, 1, 1
1, 0, 0
1, 0, 1
REV. D
Zero-Scale
Calibration
Full-Scale
Calibration
Shorted Inputs
AIN
VREF
AIN
Shorted Inputs
–17–
AIN
VREF
VREF
Sequence
Duration
1-Step
2-Step
2-Step
1-Step
1-Step
9 ⫻ 1/Output Rate
4 ⫻ 1/Output Rate
4 ⫻ 1/Output Rate
9 ⫻ 1/Output Rate
6 ⫻ 1/Output Rate
AD7713
The amount of offset that can be accommodated depends on
whether the unipolar or bipolar mode is being used. This offset
range is limited by the requirement that the positive full-scale
calibration limit is ≤ 1.05 ⫻ VREF/GAIN for AIN1 and AIN2.
Therefore, the offset range plus the span range cannot exceed
1.05 ⫻ VREF/GAIN for AIN1 and AIN2. If the span is at its
minimum (0.8 ⫻ VREF/GAIN), the maximum the offset can be
is (0.25 ⫻ VREF/GAIN) for AIN1 and AIN2. For AIN3, both
ranges are multiplied by a factor of 4.
It is also important that power is applied to the AD7713 before
signals at REF IN, AIN, or the logic input pins in order to avoid
excessive current. If separate supplies are used for the AD7713 and
the system digital circuitry, then the AD7713 should be powered
up first. If it is not possible to guarantee this, then current limiting
resistors should be placed in series with the logic inputs.
DIGITAL 5V
SUPPLY
ANALOG
SUPPLY
In the bipolar mode, the system offset calibration range is
again restricted by the span range. The span range of the
converter in bipolar mode is equidistant around the voltage
used for the zero-scale point, thus the offset range plus half
the span range cannot exceed (1.05 ⫻ VREF/GAIN) for AIN1
and AIN2. If the span is set to 2 ⫻ VREF/GAIN, the offset
span cannot move more than ± (0.05 ⫻ VREF/GAIN) before
the endpoints of the transfer function exceed the input overrange
limits ± (1.05 ⫻ VREF/GAIN) for AIN1. If the span range is set to
the minimum ± (0.4 ⫻ VREF/GAIN), the maximum allowable
offset range is ± (0.65 ⫻ VREF/GAIN) for AIN1 and AIN2. The
AIN3 input can only be used in the unipolar mode.
10␮F
0.1␮F
0.1␮F
AVDD
DVDD
AD7713
Figure 9. Recommended Decoupling Scheme
DIGITAL INTERFACE
The AD7713’s serial communications port provides a flexible
arrangement to allow easy interfacing to industry-standard
microprocessors, microcontrollers, and digital signal processors.
A serial read to the AD7713 can access data from the output
register, the control register, or from the calibration registers. A
serial write to the AD7713 can write data to the control register
or the calibration registers.
POWER-UP AND CALIBRATION
On power-up, the AD7713 performs an internal reset, which
sets the contents of the control register to a known state. However, to ensure correct calibration for the device, a calibration
routine should be performed after power-up.
Two different modes of operation are available, optimized for
different types of interface where the AD7713 can act either as
master in the system (it provides the serial clock) or as slave (an
external serial clock can be provided to the AD7713). These
two modes, labeled self-clocking mode and external clocking
mode, are discussed in detail in the following sections.
The power dissipation and temperature drift of the AD7713 are
low and no warm-up time is required before the initial calibration is performed. However, the external reference must have
stabilized before calibration is initiated.
Self-Clocking Mode
Drift Considerations
The AD7713 uses chopper stabilization techniques to minimize
input offset drift. Charge injection in the analog switches and dc
leakage currents at the sampling node are the primary sources of
offset voltage drift in the converter. The dc input leakage current is essentially independent of the selected gain. Gain drift
within the converter depends primarily upon the temperature
tracking of the internal capacitors. It is not affected by leakage
currents.
Measurement errors due to offset drift or gain drift can be eliminated at any time by recalibrating the converter or by operating
the part in the background calibration mode. Using the system
calibration mode can also minimize offset and gain errors in the
signal conditioning circuitry. Integral and differential linearity
errors are not significantly affected by temperature changes.
POWER SUPPLIES AND GROUNDING
The analog and digital supplies to the AD7713 are independent
and separately pinned out to minimize coupling between the
analog and digital sections of the device. The digital filter will
provide rejection of broadband noise on the power supplies,
except at integer multiples of the modulator sampling frequency.
The digital supply (DVDD) must not exceed the analog positive
supply (AVDD) by more than 0.3 V. If separate analog and digital
supplies are used, the recommended decoupling scheme is shown
in Figure 9. In systems where AVDD = 5 V and DVDD = 5 V, it is
recommended that AVDD and DVDD are driven from the same 5 V
supply, although each supply should be decoupled separately as
shown in Figure 9. It is preferable that the common supply is the
system’s analog 5 V supply.
The AD7713 is configured for its self-clocking mode by tying
the MODE pin high. In this mode, the AD7713 provides the
serial clock signal used for the transfer of data to and from the
AD7713. This self-clocking mode can be used with processors
that allow an external device to clock their serial port, including
most digital signal processors and microcontrollers, such as the
68HC11 and 68HC05. It also allows easy interfacing, to serial
parallel conversion circuits in systems with parallel data communication, allowing interfacing to 74XX299 universal shift
registers without any additional decoding. In the case of shift
registers, the serial clock line should have a pull-down resistor
instead of the pull-up resistor shown in Figure 10 and Figure 11.
Read Operation
Data can be read from either the output register, the control
register, or the calibration registers. A0 determines whether the
data read accesses data from the control register or from the
output/calibration registers. This A0 signal must remain valid for
the duration of the serial read operation. With A0 high, data is
accessed from either the output register or from the calibration
registers. With A0 low, data is accessed from the control register.
The function of the DRDY line is dependent on only the output
update rate of the device and the reading of the output data
register. DRDY goes low when a new data-word is available in
the output data register. It is reset high when the last bit of data
(either 16th bit or 24th bit) is read from the output register. If
data is not read from the output register, the DRDY line will
remain low. The output register will continue to be updated at
the output update rate, but DRDY will not indicate this. A read
from the device in this circumstance will access the most recent
–18–
REV. D
AD7713
DRDY (O)
t3
t2
A0 (I)
t4
t5
RFS (I)
t6
t9
SCLK (O)
t8
t7
SDATA (O)
t10
MSB
LSB
THREE-STATE
Figure 10. Self-Clocking Mode, Output Data Read Operation
A0 (I)
t14
t15
TFS (I)
t16
t9
t17
SCLK (O)
t18
t10
t19
SDATA (I)
MSB
LSB
Figure 11. Self-Clocking Mode, Control/Calibration Register Write Operation
word in the output register. If a new data-word becomes available to the output register while data is being read from the
output register, DRDY will not indicate this and the new dataword will be lost to the user. DRDY is not affected by reading
from the control register or the calibration registers.
Write Operation
Data can be written to either the control register or calibration
registers. In either case, the write operation is not affected by
the DRDY line, and the write operation does not have any
effect on the status of DRDY. A write operation to the control
register or the calibration register must always write 24 bits to
the respective register.
Data can be accessed from the output data register only when
DRDY is low. If RFS goes low with DRDY high, no data transfer will take place. DRDY does not have any effect on reading
data from the control register or from the calibration registers.
Figure 10 shows a timing diagram for reading from the AD7713
in the self-clocking mode. This read operation shows a read
from the AD7713’s output data register. A read from the control register or calibration registers is similar, but, in these cases,
the DRDY line is not related to the read function. Depending
on the output update rate, it can go low at any stage in the
control/calibration register read cycle without affecting the read
and its status should be ignored. A read operation from either
the control or calibration registers must always read 24 bits of
data from the respective register.
Figure 10 shows a read operation from the AD7713. For the
timing diagram shown, it is assumed that there is a pull-up
resistor on the SCLK output. With DRDY low, the RFS input
is brought low. RFS going low enables the serial clock of the
AD7713 and also places the MSB of the word on the serial data
line. All subsequent data bits are clocked out on a high-to-low
transition of the serial clock and are valid prior to the following
rising edge of this clock. The final active falling edge of SCLK
clocks out the LSB, and this LSB is valid prior to the final active
rising edge of SCLK. Coincident with the next falling edge of
SCLK, DRDY is reset high. DRDY going high turns off the
SCLK and the SDATA outputs, this means that the data hold
time for the LSB is slightly shorter than for all other bits.
REV. D
Figure 11 shows a write operation to the AD7713. A0 determines
whether a write operation transfers data to the control register
or to the calibration registers. This A0 signal must remain valid
for the duration of the serial write operation. The falling edge of
TFS enables the internally generated SCLK output. The serial
data to be loaded to the AD7713 must be valid on the rising
edge of this SCLK signal. Data is clocked into the AD7713 on
the rising edge of the SCLK signal, with the MSB transferred
first. On the last active high time of SCLK, the LSB is loaded to
the AD7713. Subsequent to the next falling edge of SCLK, the
SCLK output is turned off. (The timing diagram of Figure 11
assumes a pull-up resistor on the SCLK line.)
External Clocking Mode
The AD7713 is configured for its external clocking mode by
tying the MODE pin low. In this mode, SCLK of the AD7713
is configured as an input, and an external serial clock must be
provided to this SCLK pin. This external clocking mode is
designed for direct interface to systems which provide a serial
clock output which is synchronized to the serial data output,
including microcontrollers, such as the 80C51, 87C51,
68HC11, and 68HC05, and most digital signal processors.
Read Operation
As with the self-clocking mode, data can be read from either the
output register, the control register, or the calibration registers.
A0 determines whether the data read accesses data from the
control register or from the output/calibration registers. This A0
–19–
AD7713
DRDY (O)
t20
t21
A0 (I)
t22
t23
RFS (I)
t26
t28
SCLK (I)
t24
t25
t27
t29
THREE-STATE
SDATA (O)
LSB
MSB
Figure 12a. External Clocking Mode, Output Data Read Operation
DRDY (O)
t20
A0 (I)
t22
RFS (I)
t26
t30
SCLK (I)
t24
t25
t27
t31
t24
t25
THREE-STATE
SDATA (O)
BIT N
MSB
BIT N+1
Figure 12b. External Clocking Mode, Output Data Read (RFS Returns High During Read Operation)
signal must remain valid for the duration of the serial read operation. With A0 high, data is accessed from either the output
register or from the calibration registers. With A0 low, data is
accessed from the control register.
low at any stage in the control/calibration register read cycle
without affecting the read and its status should be ignored. A
read operation from either the control or calibration registers
must always read 24 bits of data from the respective register.
The function of the DRDY line is dependent on only the output
update rate of the device and the reading of the output data
register. DRDY goes low when a new data-word is available in
the output data register. It is reset high when the last bit of data
(either 16th bit or 24th bit) is read from the output register. If
data is not read from the output register, the DRDY line will
remain low. The output register will continue to be updated at
the output update rate, but DRDY will not indicate this. A read
from the device in this circumstance will access the most recent
word in the output register. If a new data-word becomes available to the output register while data is being read from the
output register, DRDY will not indicate this, and the new dataword will be lost to the user. DRDY is not affected by reading
from the control register or the calibration register.
Figure 12a shows a read operation from the AD7713 where
RFS remains low for the duration of the data-word transmission. With DRDY low, the RFS input is brought low. The input
SCLK signal should be low between read and write operations.
RFS going low places the MSB of the word to be read on the
serial data line. All subsequent data bits are clocked out on a
high-to-low transition of the serial clock and are valid prior to
the following rising edge of this clock. The penultimate falling
edge of SCLK clocks out the LSB and the final falling edge
resets the DRDY line high. This rising edge of DRDY turns off
the serial data output.
Data can be accessed from the output data register only when
DRDY is low. If RFS goes low while DRDY is high, no data
transfer will take place. DRDY does not have any effect on reading data from the control register or from the calibration registers.
Figure 12b shows a timing diagram for a read operation where
RFS returns high during the transmission of the word and
returns low again to access the rest of the data-word. Timing
parameters and functions are very similar to that outlined for
Figure 12a, but Figure 12b has a number of additional times
to show timing relationships when RFS returns high in the
middle of transferring a word.
Figures 12a and 12b show timing diagrams for reading from the
AD7713 in the external clocking mode. Figure 12a shows a
situation where all the data is read from the AD7713 in one
read operation. Figure 12b shows a situation where the data is
read from the AD7713 over a number of read operations. Both
read operations show a read from the AD7713’s output data
register. A read from the control register or calibration registers
is similar, but in these cases, the DRDY line is not related to the
read function. Depending on the output update rate, it can go
RFS should return high during a low time of SCLK. On the
rising edge of RFS, the SDATA output is turned off. DRDY
remains low and will remain low until all bits of the data-word
are read from the AD7713, regardless of the number of times
RFS changes state during the read operation. Depending on the
time between the falling edge of SCLK and the rising edge of
RFS, the next bit (BIT N + 1) may appear on the data bus
before RFS goes high. When RFS returns low again, it activates
the SDATA output. When the entire word is transmitted, the
–20–
REV. D
AD7713
A0 (I)
t32
t33
TFS (I)
t26
t34
SCLK (I)
t35
t27
t36
SDATA (I)
LSB
MSB
Figure 13a. External Clocking Mode, Control/Calibration Register Write Operation
A0 (I)
t32
TFS (I)
t26
t30
SCLK (I)
t27
t36
t35
SDATA (I)
BIT N
MSB
t36
t35
BIT N+1
Figure 13b. External Clocking Mode, Control/Calibration Register Write Operation
(TFS Returns High During Write Operation)
DRDY line will go high, turning off the SDATA output as per
Figure 12a.
the next high level of the SCLK input. On the last active high
time of the SCLK input, the LSB is loaded to the AD7713.
Write Operation
SIMPLIFYING THE EXTERNAL CLOCKING MODE
INTERFACE
Data can be written to either the control register or calibration
registers. In either case, the write operation is not affected by
the DRDY line, and the write operation does not have any
effect on the status of DRDY. A write operation to the control
register or the calibration register must always write 24 bits to
the respective register.
Figure 13a shows a write operation to the AD7713 with TFS
remaining low for the duration of the write operation. A0
determines whether a write operation transfers data to the control register or to the calibration registers. This A0 signal must
remain valid for the duration of the serial write operation. As
before, the serial clock line should be low between read and
write operations. The serial data to be loaded to the AD7713
must be valid on the high level of the externally applied SCLK
signal. Data is clocked into the AD7713 on the high level of this
SCLK signal with the MSB transferred first. On the last active
high time of SCLK, the LSB is loaded to the AD7713.
In many applications, the user may not require the facility of
writing to the on-chip calibration registers. In this case, the
serial interface to the AD7713 in external clocking mode can be
simplified by connecting the TFS line to the A0 input of the
AD7713 (see Figure 14). This means that any write to the
device will load data to the control register (since A0 is low
while TFS is low), and any read to the device will access data
from the output data register or from the calibration registers
(since A0 is high while RFS is low). It should be noted that in
this arrangement, the user does not have the capability of reading from the control register. Another method of simplifying the
interface is to generate the TFS signal from an inverted RFS
signal. However, generating the signals the opposite way around
(RFS from an inverted TFS) will cause writing errors.
Figure 13b shows a timing diagram for a write operation to the
AD7713 with TFS returning high during the write operation
and returning low again to write the rest of the data-word. Timing parameters and functions are very similar to that outlined
for Figure 13a, but Figure 13b has a number of additional times
to show timing relationships when TFS returns high in the
middle of transferring a word.
RFS
FOUR
INTERFACE
LINES
SDATA
SCLK
AD7713
TFS
A0
Data to be loaded to the AD7713 must be valid prior to the
rising edge of the SCLK signal. TFS should return high during
the low time of SCLK. After TFS returns low again, the next bit
of the data-word to be loaded to the AD7713 is clocked in on
REV. D
–21–
Figure 14. Simplified Interface with TFS Connected to A0
AD7713
MICROCOMPUTER/MICROPROCESSOR INTERFACING
The AD7713’s flexible serial interface allows easy interface to
most microcomputers and microprocessors. Figure 15 shows a
flowchart diagram for a typical programming sequence for reading data from the AD7713 to a microcomputer, while Figure 16
shows a flowchart diagram for writing data to the AD7713.
Figures 17 and 18 show some typical interface circuits.
The flowchart in Figure 15 is for continuous read operations
from the AD7713 output register. In the example shown, the
DRDY line is continuously polled. Depending on the microprocessor configuration, the DRDY line may come to an interrupt
input, in which case the DRDY will automatically generate an
interrupt without being polled. Reading the serial buffer could
be anything from one read operation up to three read operations
(where 24 bits of data are read into an 8-bit serial register). A
read operation to the control/calibration registers is similar, but,
in this case, the status of DRDY can be ignored. The A0 line is
brought low when the RFS line is brought low when reading
from the control register.
memory. Writing data to the serial buffer from the accumulator
will generally consist of either two or three write operations,
depending on the size of the serial buffer.
The flowchart also shows the option of the bits being reversed
before being written to the serial buffer. This depends on whether
the first bit transmitted by the microprocessor is the MSB or the
LSB. The AD7713 expects the MSB as the first bit in the data
stream. In cases where the data is being read or being written in
bytes and the data has to be reversed, the bits will have to be
reversed for every byte.
START
CONFIGURE AND
INITIALIZE ␮C/␮P
SERIAL PORT
BRING RFS,TFS
AND A0 HIGH
START
LOAD DATA FROM
ADDRESS TO
ACCUMULATOR
CONFIGURE AND
INITIALIZE ␮C/␮P
SERIAL PORT
REVERSE ORDER
OF BITS
BRING RFS,TFS
AND HIGH
BRING RFS AND A0 LOW
ⴛ3
POLL DRDY
DRDY
LOW?
WRITE DATA FROM
ACCUMULATOR TO
SERIAL BUFFER
BRING TFS AND A0 HIGH
NO
END
YES
Figure 16. Flowchart for Single Write Operation to
the AD7713
BRING RFS LOW
ⴛ3
READ SERIAL BUFFER
BRING RFS HIGH
REVERSE ORDER
OF BITS
AD7713 to 8XC51 Interface
Figure 17 shows an interface between the AD7713 and the 8XC51
microcontroller. The AD7713 is configured for its external clocking mode, while the 8XC51 is configured in its Mode 0 serial
interface mode. The DRDY line from the AD7713 is connected to
the Port P1.2 input of the 8XC51, so the DRDY line is polled by
the 8XC51. The DRDY line can be connected to the INT1 input
of the 8XC51 if an interrupt driven system is preferred.
DVDD
Figure 15. Flowchart for Continuous Read Operation
to the AD7713
SYNC
The flowchart also shows the bits being reversed after they have
been read in from the serial port. This depends on whether the
microprocessor expects the MSB of the word first or the LSB of
the word first. The AD7713 outputs the MSB first.
8XC51
The flowchart in Figure 16 is for a single 24-bit write operation
to the AD7713 control or calibration registers. This shows data
being transferred from data memory to the accumulator before
being written to the serial buffer. Some microprocessor systems
will allow data to be written directly to the serial buffer from data
P1.0
RFS
P1.1
TFS
P1.2
DRDY
P1.3
A0
P3.0
SDATA
P3.1
SCLK
AD7713
MODE
Figure 17. AD7713 to 8XC51 Interface
–22–
REV. D
AD7713
Table V shows some typical 8XC51 code used for a single 24-bit
read from the output register of the AD7713. Table V shows
some typical code for a single write operation to the control
register of the AD7713. The 8XC51 outputs the LSB first in a
write operation while the AD7713 expects the MSB first, so the
data to be transmitted has to be rearranged before being written
to the output serial register. Similarly, the AD7713 outputs the
MSB first during a read operation while the 8XC51 expects the
LSB first. Therefore, the data which is read into the serial buffer
needs to be rearranged before the correct data-word from the
AD7713 is available in the accumulator.
Table V. 8XC51 Code for Reading from the AD7713
MOV SCON,#00010001B;
MOV IE,#00010000B;
SETB 90H;
SETB 91H;
SETB 93H;
MOV R1,#003H;
MOV R0,#030H;
Configure 8051 for MODE 0
Disable All Interrupts
Set P1.0, Used as RFS
Set P1.1, Used as TFS
Set P1.3, Used as A0
Sets Number of Bytes to Be Read
in A Read Operation
Start Address for Where Bytes
Will Be Loaded
Use P1.2 as DRDY
MOV R6,#004H;
WAIT:
NOP;
MOV A,P1;
Read Port 1
ANL A,R6;
Mask Out All Bits Except DRDY
JZ READ;
If Zero Read
SJMP WAIT;
Otherwise Keep Polling
READ:
CLR 90H;
Bring RFS Low
CLR 98H;
Clear Receive Flag
POLL:
JB 98H, READ1
Tests Receive Interrupt Flag
SJMP POLL
READ 1:
MOV A,SBUF;
Read Buffer
RLC A;
Rearrange Data
MOV B.0,C;
Reverse Order of Bits
RLC A; MOV B.1,C; RLC A; MOV B.2,C;
RLC A; MOV B.3,C; RLC A; MOV B.4,C;
RLC A; MOV B.5,C; RLC A; MOV B.6,C;
RLC A; MOV B.7,C;
MOV A,B;
MOV @R0,A; Write Data to Memory
INC R0;
Increment Memory Location
DEC R1
Decrement Byte Counter
MOV A,R1
JZ END
Jump if Zero
JMP WAIT
Fetch Next Byte
END:
SETB 90H
Bring RFS High
FIN:
SJMP FIN
REV. D
Table VI. 8XC51 Code for Writing to the AD7713
MOV SCON,#00000000B;
MOV IE,#10010000B;
MOV IP,#00010000B;
SETB 91H;
SETB 90H;
MOV R1,#003H;
MOV R0,#030H;
MOV A,#00H;
MOV SBUF,A;
WAIT:
JMP WAIT;
INT ROUTINE:
NOP;
MOV A,R1;
JZ FIN;
DEC R1;
MOV A,@R;
INC R0;
RLC A;
Configure 8051 for MODE 0
Operation and Enable Serial
Reception
Enable Transmit Interrupt
Prioritize the Transmit Interrupt
Bring TFS High
Bring RFS High
Sets Number of Bytes to Be
Written in a Write Operation
Start Address in RAM for Bytes
Clear Accumulator
Initialize the Serial Port
Wait for Interrupt
Interrupt Subroutine
Load R1 to Accumulator
If Zero Jump to FIN
Decrement R1 Byte Counter
Move Byte into the Accumulator
Increment Address
Rearrange Data—From LSB
First to MSB First
MOV B.0,C; RLC A; MOV B.1,C; RLC A;
MOV B.2,C; RLC A; MOV B.3,C; RLC A;
MOV B.4,C; RLC A; MOV B.5,C; RLC A;
MOV B.6,C; RLC A: MOV B.7,C; MOV A,B;
CLR 93H;
Bring A0 Low
CLR 91H;
Bring TFS Low
MOV SBUF,A;
Write to Serial Port
RETI;
Return from Subroutine
FIN:
SETB 91H;
Set TFS High
SETB 93H;
Set A0 High
RETI;
Return from Interrupt Subroutine
AD7713 to 68HC11 Interface
Figure 18 shows an interface between the AD7713 and the
68HC11 microcontroller. The AD7713 is configured for its external clocking mode, while the SPI port is used on the 68HC11,
which is in its single chip mode. The DRDY line from the AD7713
is connected to the Port PC2 input of the 68HC11, so the DRDY
line is polled by the 68HC11. The DRDY line can be connected to
the IRQ input of the 68HC11 if an interrupt driven system is
preferred. The 68HC11 MOSI and MISO lines should be configured for wired-OR operation. Depending on the interface
configuration, it may be necessary to provide bidirectional buffers
between the 68HC11 MOSI and MISO lines.
The 68HC11 is configured in the master mode with its CPOL
bit set to a Logic 0 and its CPHA bit set to a Logic 1.
–23–
AD7713
DVDD
3-Wire RTD Configurations
DVDD
SS
SYNC
PC0
RFS
PC1
TFS
PC2
DRDY
PC3
A0
SCK
SCLK
68HC11
MISO
SDATA
MOSI
MODE
AD7713
Figure 18. AD7713 to 68HC11 Interface
APPLICATIONS
4-Wire RTD Configurations
Figure 19 shows a 4-wire RTD application where the RTD
transducer is interfaced directly to the AD7713. In the 4-wire
configuration, there are no errors associated with lead resistances as no current flows in the measurement leads connected
to AIN1(+) and AIN1(–). One of the RTD current sources is
used to provide the excitation current for the RTD. A common
nominal resistance value for the RTD is 100 Ω and, therefore, the
RTD will generate a 20 mV signal, which can be handled directly
by the analog input of the AD7713. In the circuit shown, the
second RTD excitation current is used to generate the reference
voltage for the AD7713. This reference voltage is developed
across RREF and applied to the differential reference inputs. For
the nominal reference voltage of 2.5 V, RREF is 12.5 kΩ. This
scheme ensures that the analog input voltage span remains
ratiometric to the reference voltage. Any errors in the analog
input voltage due to the temperature drift of the RTD current
source is compensated for by the variation in the reference voltage. The typical matching between the two RTD current sources
is less than 3 ppm/°C.
5V
AVDD
DVDD
200␮A
RTD2
AD7713
REF IN(+)
RREF
REF IN(–)
INTERNAL
CIRCUITRY
Figure 20 shows a 3-wire RTD configuration using the AD7713.
In the 3-wire configuration, the lead resistances will result in
errors if only one current source is used as the 200 µA will flow
through RL1 developing a voltage error between AIN1(+) and
AIN1(–). In the scheme outlined below, the second RTD current source is used to compensate for the error introduced by
the 200 µA flowing through RL1. The second RTD current
flows through RL2. Assuming RL1 and RL2 are equal (the leads
would normally be of the same material and of equal length) and
RTD1 and RTD2 match, then the error voltage across RL2 equals
the error voltage across RL1, and no error voltage is developed
between AIN1(+) and AIN1(–). Twice the voltage is developed
across RL3 but since this is a common-mode voltage, it will not
introduce any errors. The reference voltage is derived from one
of the current sources. This gives all the benefits of eliminating
RTD temperature coefficient errors as outlined in Figure 19.
The voltage on either RTD input can go to within 2 V of the
AVDD supply. The circuit is shown for a 2.5 V reference.
AVDD DVDD
REF IN(+)
200␮A
RTD1
12.5k⍀
RL1
INTERNAL
CIRCUITRY
AIN(+)
PGA
AIN(–)
RTD
A = 1 – 128
RL2
RTD2
RL3
AGND
200␮A
AD7713
DGND
Figure 20. 3-Wire RTD Application with the AD7713
4–20 mA Loop
The AD7713’s high level input can be used to measure the
current in 4–20 mA loop applications as shown in Figure 21. In
this case, the system calibration capabilities of the AD7713 can
be used to remove the offset caused by the 4 mA flowing through
the 500 Ω resistor. The AD7713 can handle an input span as
low as 3.2 ⫻ VREF (= 8 V with a VREF of 2.5 V) even though the
nominal input voltage range for the input is 10 V. Therefore,
the full span of the ADC can be used for measuring the current
between 4 and 20 mA.
200␮A
ANALOG 5V SUPPLY
RTD1
AVDD
AIN1(+)
RTD
REF IN(–)
DVDD
REF IN(–) REF IN(+)
AVDD
PGA
1␮A
AIN1(–)
INTERNAL
CIRCUITRY
A = 1 – 128
AGND
MUX
AIN1(+)
AIN1(–)
DGND
AIN3
4–20mA
LOOP
Figure 19. 4-Wire RTD Application with the AD7713
PGA
VOLTAGE
ATTENUATION
A = 1 – 128
AD7713
500⍀
AGND
DGND
Figure 21. 4-20 mA Measurement Using the AD7713
–24–
REV. D
AD7713
OTHER 24-BIT SIGNAL CONDITIONING ADCS AVAILABLE
FROM ANALOG DEVICES
AD7710
FUNCTIONAL BLOCK DIAGRAM
FEATURES
Charge Balancing
24 Bits No Missing Codes
ⴞ0.0015% Nonlinearity
2-Channel Programmable Gain Front End
Gains from 1 to 128
Differential Inputs
Low-Pass Filter with Programmable Filter Cutoffs
Ability to Read/Write Calibration Coefficients
Bidirectional Microcontroller Serial Interface
Internal/External Reference Option
Single- or Dual-Supply Operation
Low Power (25 mW typ) with Power-Down Mode
(7 mW typ)
REF REF
AVDD DVDD IN(–) IN(+)
REF OUT
VBIAS
AVDD
2.5V REFERENCE
4.5␮A
CHARGING BALANCING A/D
CONVERTER
AUTO-ZEROED
⌺–⌬
MODULATOR
AIN1(+)
MUX
AIN1(–)
AIN2(+)
AIN2(–)
PGA
A = 1 – 128
AVDD
20␮A
CLOCK
GENERATION
MCLK
IN
MCLK
OUT
OUTPUT
REGISTER
CONTROL
REGISTER
AD7710
AGND DGND VSS
AD7711
RFS
TFS MODE SDATA SCLK DRDY A0
FUNCTIONAL BLOCK DIAGRAM
FEATURES
Charge Balancing ADC
24 Bits No Missing Codes
ⴞ0.0015% Nonlinearity
2-Channel Programmable Gain Front End
Gains from 1 to 128
1 Differential Input
1 Single-Ended Input
Low-Pass Filter with Programmable Filter Cutoff
Ability to Read/Write Calibration Coefficients
RTD Excitation Current Sources
Bidirectional Microcontroller Serial Interface
Internal/External Reference Option
Single- or Dual-Supply Operation
Low Power (25 mW typ) with Power-Down Mode
(7 mW typ)
REF REF
AVDD DVDD IN(–) IN(+)
VBIAS
REF OUT
AVDD
2.5V REFERENCE
4.5␮A
CHARGING BALANCING A/D
CONVERTER
AIN1(–)
MUX
AIN1(+)
AIN2
PGA
AUTO-ZEROED
⌺–⌬
MODULATOR
DIGITAL
FILTER
A = 1 – 128
200␮A
CLOCK
GENERATION
AVDD
RTD1
SERIAL INTERFACE
200␮A
CONTROL
REGISTER
RTD2
OUTPUT
REGISTER
AD7711
APPLICATIONS
RTD Transducers
Process Control
Smart Transmitters
Portable Industrial Instruments
REV. D
SYNC
SERIAL INTERFACE
RTD
CURRENT
APPLICATIONS
Weigh Scales
Thermocouples
Smart Transmitters
Chromatography
DIGITAL
FILTER
AGND DGND VSS
–25–
RFS
TFS MODE SDATA SCLK DRDY A0
SYNC
MCLK
IN
MCLK
OUT
AD7713
AD7712
FUNCTIONAL BLOCK DIAGRAM
FEATURES
Charge Balancing ADC
24 Bits No Missing Codes
ⴞ0.0015% Nonlinearity
High Level and Low Level Analog Input Channels
Programmable Gain for Both Inputs
Gains from 1 to 128
Differential Input for Low Level Channel
Low-Pass Filter with Programmable Filter Cutoffs
Ability to Read/Write Calibration Coefficients
Bidirectional Microcontroller Serial Interface
Internal/External Reference Option
Single- or Dual-Supply Operation
Low Power (25 mW typ) with Power-Down Mode
(100 ␮W typ)
REF REF
AVDD DVDD IN(–) IN(+)
VBIAS
REF OUT
AVDD
2.5V REFERENCE
4.5␮A
CHARGING BALANCING A/D
CONVERTER
AIN1(–)
MUX
AIN1(+)
PGA
AUTO-ZEROED
⌺–⌬
MODULATOR
DIGITAL
FILTER
STANDBY
A = 1 – 128
CLOCK
GENERATION
AIN2
VOLTAGE
ATTENUATION
MCLK
IN
MCLK
OUT
SERIAL INTERFACE
CONTROL
REGISTER
TP
APPLICATIONS
Process Control
Smart Transmitters
Portable Industrial Instruments
SYNC
OUTPUT
REGISTER
AD7712
AGND DGND VSS
–26–
RFS
TFS MODE SDATA SCLK DRDY A0
REV. D
AD7713
OUTLINE DIMENSIONS
24-Lead Plastic Dual In-Line Package [PDIP]
(N-24)
Dimensions shown in inches and (millimeters)
1.185 (30.01)
1.165 (29.59)
1.145 (29.08)
0.295 (7.49)
0.285 (7.24)
0.275 (6.99)
24
13
1
12
0.180
(4.57)
MAX
0.325 (8.26)
0.310 (7.87)
0.300 (7.62)
0.015 (0.38) MIN
0.150 (3.81)
0.130 (3.30)
0.110 (2.79)
0.022 (0.56)
0.018 (0.46)
0.014 (0.36)
0.100
(2.54)
BSC
0.150 (3.81)
0.135 (3.43)
0.120 (3.05)
0.060 (1.52) SEATING
0.050 (1.27) PLANE
0.045 (1.14)
0.015 (0.38)
0.010 (0.25)
0.008 (0.20)
COMPLIANT TO JEDEC STANDARDS MO-095AG
CONTROLLING DIMENSIONS ARE IN INCHES; MILLIMETER DIMENSIONS
(IN PARENTHESES) ARE ROUNDED-OFF INCH EQUIVALENTS FOR
REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN
24-Lead Ceramic Dual In-Line Package [CERDIP]
(Q-24)
Dimensions shown in inches and (millimeters)
0.098 (2.49)
MAX
0.005 (0.13)
MIN
24
0.310 (7.87)
0.220 (5.59)
13
PIN 1
1
12
0.200 (5.08)
MAX
0.060 (1.52)
0.015 (0.38)
1.280 (32.51) MAX
0.320 (8.13)
0.290 (7.37)
0.150 (3.81)
MIN
0.200 (5.08)
0.125 (3.18)
0.100
(2.54)
BSC
0.023 (0.58)
0.014 (0.36)
0.015 (0.38)
0.008 (0.20)
15
0
0.070 (1.78) SEATING
PLANE
0.030 (0.76)
CONTROLLING DIMENSIONS ARE IN INCHES; MILLIMETER DIMENSIONS
(IN PARENTHESES) ARE ROUNDED-OFF INCH EQUIVALENTS FOR
REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN
24-Lead Standard Small Outline Package [SOIC]
Wide Body
(RW-24)
Dimensions shown in millimeters and (inches)
15.60 (0.6142)
15.20 (0.5984)
24
13
7.60 (0.2992)
7.40 (0.2913)
1
12
2.65 (0.1043)
2.35 (0.0925)
10.65 (0.4193)
10.00 (0.3937)
0.75 (0.0295)
ⴛ 45ⴗ
0.25 (0.0098)
0.30 (0.0118)
0.10 (0.0039)
COPLANARITY
0.10
1.27 (0.0500)
BSC
0.51 (0.0201)
0.31 (0.0122)
8ⴗ
0ⴗ
SEATING
0.33 (0.0130)
PLANE
0.20 (0.0079)
1.27 (0.0500)
0.40 (0.0157)
COMPLIANT TO JEDEC STANDARDS MS-013AD
CONTROLLING DIMENSIONS ARE IN MILLIMETERS; INCH DIMENSIONS
(IN PARENTHESES) ARE ROUNDED-OFF MILLIMETER EQUIVALENTS FOR
REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN
REV. D
–27–
AD7713
Revision History
Location
Page
3/04—Data Sheet changed from REV. C to REV. D.
Changes to FUNCTIONAL BLOCK DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Changes to SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Changes to ORDERING GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Changes to Self-Calibration section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Changes to AD7713 to 68HC11 Interface section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Deleted AD7713 to ADSP-2105 Interface section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Deleted Figure 19 and renumbered succeeding figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Updated OUTLINE DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
–28–
REV. D
C01553–0–3/04(D)
Updated layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Universal