INTERSIL HI7191IB

HI7191
24-Bit, High Precision,
Sigma Delta A/D Converter
March 1998
Features
Description
• 22-Bit Resolution with No Missing Code
The Intersil HI7191 is a monolithic instrumentation, sigma delta
A/D converter which operates from ±5V supplies. Both the signal and reference inputs are fully differential for maximum flexibility and performance. An internal Programmable Gain
Instrumentation Amplifier (PGIA) provides input gains from 1 to
128 eliminating the need for external pre-amplifiers. The ondemand converter auto-calibrate function is capable of removing offset and gain errors existing in external and internal circuitry. The on-board user programmable digital filter provides
over -120dB of 60/50Hz noise rejection and allows fine tuning
of resolution and conversion speed over a wide dynamic range.
The HI7191 and HI7191 are functionally the same device so all
discussion will refer to the HI7191 for simplicity.
• 0.0007% Integral Non-Linearity (Typ)
• 20mV to ±2.5V Full Scale Input Ranges
• Internal PGIA with Gains of 1 to 128
• Serial Data I/O Interface, SPI Compatible
• Differential Analog and Reference Inputs
• Internal or System Calibration
• -120dB Rejection of 60/50Hz Line Noise
• Settling Time of 4 Conversions (Max) for a Step Input
Applications
• Process Control and Measurement
The HI7191 contains a serial I/O port and is compatible with
most synchronous transfer formats including both the Motorola 6805/11 series SPI and Intel 8051 series SSR protocols.
A sophisticated set of commands gives the user control over
calibration, PGIA gain, device selection, standby mode, and
several other features. The On-chip Calibration Registers
allow the user to read and write calibration data.
• Industrial Weight Scales
• Part Counting Scales
• Laboratory Instrumentation
• Seismic Monitoring
• Magnetic Field Monitoring
• Additional Reference Literature
- TB348 “HI7190/1 Negative Full Scale Error vs
Conversion Frequency”
- AN9504 “A Brief Intro to Sigma Delta Conversion”
- TB329 “Intersil Sigma Delta Calibration Technique”
- AN9505 “Using the HI7190 Evaluation Kit”
- TB331 “Using the HI7190 Serial Interface”
- AN9527 “Interfacing HI7190 to a Microcontroller”
- AN9532 “Using HI7190 in a Multiplexed System”
- AN9601 “Using HI7190 with a Single +5V Supply”
Ordering Information
PART NUMBER
TEMP.
RANGE (oC)
PKG.
NO.
PACKAGE
HI7191IP
-40 to 85
20 Ld PDIP
E20.3
HI7191IB
-40 to 85
20 Ld SOIC
M20.3
HI7190EVAL
Evaluation Kit
Pinout
HI7191
(PDIP, SOIC)
TOP VIEW
SCLK
1
SDO
2
19 SYNC
SDIO
3
18 RESET
CS
4
17 OSC1
20 MODE
DRDY
5
16 OSC2
DGND
6
15 DVDD
AVSS
7
14 AGND
VRLO 8
13 AVDD
VRHI 9
12 VINHI
VCM 10
11 VINLO
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
http://www.intersil.com or 407-727-9207 | Copyright © Intersil Corporation 1999
1897
File Number
4138.3
HI7191
Functional Block Diagram
VRHI
AVDD
VRLO
REFERENCE
INPUTS
TRANSDUCER
BURN-OUT
CURRENT
∑−∆
MODULATOR
∫
PGIA
VINHI
∑
VINLO
∫
∑
DIGITAL FILTER
1
1-BIT
D/A
VCM
CONTROL AND SERIAL INTERFACE UNIT
SERIAL INTERFACE
UNIT
CONTROL REGISTER
CLOCK
GENERATOR
OSC1
OSC2
DRDY RESET SYNC
CS
MODE
SCLK SDIO
Typical Application Schematic
10MHz
17
13
+5V
+
16
15
OSC1 OSC2
DVDD
AVDD
4.7µF
4.7µF
0.1µF
1
0.1uF
INPUT
+
INPUT
-
+5V
+
12
11
10
R1
SCLK
VINHI
SDIO
VINLO
VCM
SDO
3
DATA I/O
2
DATA OUT
19
SYNC
+2.5V
REFERENCE
9
8
7
-5V
+
0.1µF
SYNC
4
VRHI
CS
VRLO
CS
5
DRDY
DRDY
18
AVSS
RESET
4.7µF
AGND
14
1898
MODE
DGND
6
RESET
20
SDO
HI7191
Absolute Maximum Ratings
Thermal Information
Supply Voltage
AVDD to AGND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +5.5V
AVSS to AGND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -5.5V
DVDD to DGND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +5.5V
DGND to AGND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±0.3V
Analog Input Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . AVSS to AVDD
Digital Input, Output and I/O Pins . . . . . . . . . . . . . . . DGND to DVDD
ESD Tolerance (No Damage)
Human Body Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500V
Machine Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +100V
Charged Device Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000V
Thermal Resistance (Typical, Note 1)
θJA (oC/W)
PDIP Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
125
SOIC Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
100
Maximum Junction Temperature
Plastic Packages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150oC
Maximum Storage Temperature Range . . . . . . . . . .-65oC to 150oC
Maximum Lead Temperature (Soldering, 10s) . . . . . . . . . . . . 300oC
(SOIC - Lead Tips Only)
Operating Conditions
Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . -40oC to 85oC
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation
of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
Electrical Specifications
AVDD = +5V, AVSS = -5V, DVDD = +5V, VRHI = +2.5V, VRLO = AGND = 0V, VCM = AGND,
PGIA Gain = 1, OSCIN = 10MHz, Bipolar Input Range Selected, fN = 10Hz
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNITS
±0.0007
±0.0015
%FS
SYSTEM PERFORMANCE
Integral Non-Linearity, INL
End Point Line Method (Notes 3, 5, 6)
-
Differential Non-Linearity
(Note 2)
No Missing codes to 22-Bits
Offset Error, VOS
See Table 1
-
-
-
-
Offset Error Drift
VINHI = VINLO (Notes 3, 8)
-
1
-
µV/ oC
Full Scale Error, FSE
VINHI - VINLO = +2.5V (Notes 3, 5, 8, 10)
-
-
-
-
Noise, eN
See Table 1
-
-
-
-
-70
-
dB
-
-
dB
Common Mode Rejection Ratio, CMRR VCM = 0V, VINHI = VINLO from -2V to +2V
LSB
Normal Mode 50Hz Rejection
Filter Notch = 10Hz, 25Hz, 50Hz (Note 2)
-120
Normal Mode 60Hz Rejection
Filter Notch = 10Hz, 30Hz, 60Hz (Note 2)
-120
-
-
dB
-
2
4
Conversions
0
-
VREF
V
Step Response Settling Time
ANALOG INPUTS
Input Voltage Range
Unipolar Mode (Note 9)
Input Voltage Range
Bipolar Mode (Note 9)
- VREF
-
VREF
V
Common Mode Input Range
(Note 2)
AVSS
-
AVDD
V
Input Leakage Current, IIN
VIN = AVDD (Note 2)
-
-
1.0
nA
-
5.0
-
pF
2.5
-
5
V
-
200
-
nA
Positive Full Scale Calibration Limit
-
-
1.2(VREF/Gain)
-
Negative Full Scale Calibration Limit
-
-
1.2(VREF/Gain)
-
Offset Calibration Limit
-
-
1.2(VREF/Gain)
-
0.2(VREF/Gain)
-
2.4(VREF/Gain)
-
2.0
-
-
V
-
-
0.8
V
-
1.0
10
µA
Input Capacitance, CIN
Reference Voltage Range, VREF
(VREF = VRHI - VRLO)
Transducer Burn-Out Current, IBO
CALIBRATION LIMITS
Input Span
DIGITAL INPUTS
Input Logic High Voltage, VIH
(Note 11)
Input Logic Low Voltage, VIL
Input Logic Current, II
VIN = 0V, +5V
1899
HI7191
Electrical Specifications
AVDD = +5V, AVSS = -5V, DVDD = +5V, VRHI = +2.5V, VRLO = AGND = 0V, VCM = AGND,
PGIA Gain = 1, OSCIN = 10MHz, Bipolar Input Range Selected, fN = 10Hz (Continued)
PARAMETER
Input Capacitance, CIN
TEST CONDITIONS
MIN
TYP
MAX
UNITS
-
5.0
-
pF
2.4
-
-
V
-
-
0.4
V
-10
1
10
µA
-
10
-
pF
VIN = 0V
DIGITAL OUTPUTS
Output Logic High Voltage, VOH
IOUT = -100µA (Note 7)
Output Logic Low Voltage, VOL
IOUT = 3mA (Note 7)
Output Three-State Leakage Current, VOUT = 0V, +5V (Note 7)
IOZ
Digital Output Capacitance, COUT
TIMING CHARACTERISTICS
SCLK Minimum Cycle Time, tSCLK
200
-
-
ns
SCLK Minimum Pulse Width, tSCLKPW
50
-
-
ns
CS to SCLK Precharge Time, tPRE
50
-
-
ns
500
-
-
ns
Data Setup to SCLK Rising Edge
(Write), tDSU
50
-
-
ns
Data Hold from SCLK Rising Edge
(Write), tDHLD
0
-
-
ns
(Note 7)
-
-
40
ns
Read Bit Valid from SCLK Falling Edge, (Note 7)
tDV
-
-
40
ns
Last Data Transfer to Data Ready
Inactive, tDRDY
(Note 7)
-
35
-
ns
RESET Low Pulse Width
(Note 2)
100
-
-
ns
SYNC Low Pulse Width
(Note 2)
100
-
-
ns
Oscillator Clock Frequency
(Note 2)
0.1
-
10
MHz
Output Rise/Fall Time
(Note 2)
-
-
30
ns
Input Rise/Fall Time
(Note 2)
-
-
1
µs
IAVDD
-
-
1.5
mA
IAVSS
-
-
1.5
mA
DRDY Minimum High Pulse Width
Data Read Access from Instruction
Byte Write, tACC
(Notes 2, 7)
POWER SUPPLY CHARACTERISTICS
IDVDD
SCLK = 4MHz
-
-
3.0
mA
Power Dissipation, Active PDA
SB = ‘0’
-
15
30
mW
Power Dissipation, Standby PDS
SB = ‘1’
-
5
-
mW
PSRR
(Note 3)
-
-70
-
dB
NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
θJA is measured with the component mounted on an evaluation PC board in free air.
Parameter guaranteed by design or characterization, not production tested.
Applies to both bipolar and unipolar input ranges.
These errors can be removed by re-calibrating at the desired operating temperature.
Applies after system calibration.
Fully differential input signal source is used.
See Load Test Circuit, Figure 10, R1 = 10kΩ, CL = 50pF.
1 LSB = 298nV at 24 bits for a Full Scale Range of 5V.
VREF = VRHI - VRLO
These errors are on the order of the output noise shown in Table 1.
All inputs except OSC1. The OSC1 input VIH is 3.5V minimum.
1900
HI7191
Timing Diagrams
tSCLK
tPRE
CS
tDSU
tSCLKPW
tSCLKPW
SCLK
tDHLD
SDIO
1ST BIT
2ND BIT
FIGURE 1. DATA WRITE TO HI7191
CS
SCLK
SDIO
1ST BIT
2ND BIT
SDO
tACC
tDV
FIGURE 2. DATA READ FROM HI7191
tDRDY
DRDY
CS
SCLK
SDIO
1
5
6
FIGURE 3. DATA READ FROM HI7191
1901
7
8
HI7191
Pin Descriptions
20 LEAD
DIP, SOIC
PIN NAME
1
SCLK
Serial Interface Clock. Synchronizes serial data transfers. Data is input on the rising edge and output on the
falling edge.
2
SDO
Serial Data OUT. Serial data is read from this line when using a 3-wire serial protocol such as the
Motorola Serial Peripheral Interface.
3
SDIO
Serial Data IN or OUT. This line is bidirectional programmable and interfaces directly to the Intel Standard Serial
Interface using a 2-wire serial protocol.
4
CS
5
DRDY
An Active Low Interrupt indicating that a new data word is available for reading.
6
DGND
Digital Supply Ground.
7
AVSS
Negative Analog Power Supply (-5V).
8
VRLO
External Reference Input. Should be negative referenced to VRHI .
9
VRHI
External Reference Input. Should be positive referenced to VRLO .
10
VCM
Common Mode Input. Should be set to halfway between AVDD and AVSS .
11
VINLO
Analog Input LO. Negative input of the PGIA.
12
VINHI
Analog Input HI. Positive input of the PGIA. The VINHI input is connected to a current source that can be used to check
the condition of an external transducer. This current source is controlled via the Control Register.
DESCRIPTION
Chip Select Input. Used to select the HI7191 for a serial data transfer cycle. This line can be tied to DGND.
13
AVDD
Positive Analog Power Supply (+5V).
14
AGND
Analog Supply Ground.
15
DVDD
Positive Digital Supply (+5V).
16
OSC2
Used to connect a crystal source between OSC1 and OSC2 . Leave open otherwise.
17
OSC1
Oscillator Clock Input for the device. A crystal connected between OSC1 and OSC2 will provide a clock to the
device, or an external oscillator can drive OSC1 . The oscillator frequency should be 10MHz (Typ).
18
RESET
Active Low Reset Pin. Used to initialize the HI7191 registers, filter and state machines.
19
SYNC
Active Low Sync Input. Used to control the synchronization of a number of HI7191s. A logic ‘0’ initializes the converter.
20
MODE
Mode Pin. Used to select between Synchronous Self Clocking (Mode = 1) or Synchronous External Clocking
(Mode = 0) for the Serial Port.
Load Test Circuit
V1
R1
DUT
CL (INCLUDES STRAY
CAPACITANCE)
FIGURE 4.
ESD Test Circuits
R1
V
±
R2
CESD
HUMAN BODY
CESD = 100pF
R1 = 10MΩ
R2 = 1.5kΩ
DUT
R1
CHARGED DEVICE MODEL
DUT
V
MACHINE MODEL
±
R2
R1 = 1GΩ
R2 = 1Ω
DIELECTRIC
CESD = 200pF
R1 = 10MΩ
R2 = 0Ω
FIGURE 5B.
FIGURE 5A.
1902
HI7191
TABLE 1. NOISE PERFORMANCE WITH INPUT CONNECTED TO ANALOG GROUND
HERTZ
SNR
ENOB
P-P NOISE
(µV)
RMS NOISE
(µV)
SNR
ENOB
P-P NOISE
(µV)
RMS NOISE
(µV)
GAIN = 16
GAIN = 1
10
HERTZ
132.3
21.7
9.8
1.5
10
120.1
19.7
39.8
6.0
114.8
18.8
73.4
11.1
25
129.5
21.2
13.6
2.1
25
30
127.7
20.9
16.6
2.5
30
113.5
18.6
85.1
12.9
111.0
18.1
114.4
17.3
17.9
134.0
20.3
50
126.3
20.7
19.5
3.0
50
60
125.6
20.6
21.2
3.2
60
109.6
100
122.4
20.0
30.7
4.6
100
105.5
17.2
214.8
32.5
250
95.2
15.5
699.1
105.9
250
107.7
17.6
166.7
25.3
500
98.1
16.0
505.3
76.6
500
89.1
14.5
1417.7
214.8
1000
83.5
13.6
2686.0
407.0
2000
62.6
10.1
30110.0
4562.1
1000
85.7
13.9
2101.8
318.5
2000
68.8
11.1
14661.6
2221.4
GAIN = 32
GAIN = 2
10
129.2
21.2
14.0
2.1
10
113.2
18.5
88.8
13.5
25
125.7
20.6
20.9
3.2
25
109.0
17.8
142.7
21.6
108.2
17.7
157.4
23.8
30
124.5
20.4
24.1
3.7
30
50
123.4
20.2
27.3
4.1
50
104.7
17.1
235.8
35.7
105.0
17.1
227.8
34.5
60
122.5
20.1
30.3
4.6
60
100
118.1
19.3
50.0
7.6
100
102.3
16.7
310.5
47.0
250
93.4
15.2
861.1
130.5
250
106.1
17.3
199.5
30.2
500
96.9
15.8
580.1
87.9
500
87.1
14.2
1782.7
270.1
78.2
12.7
4990.4
756.1
57.0
9.2
57311.1
8683.5
1000
84.4
13.7
2435.6
369.0
1000
2000
67.8
11.0
16469.7
2495.4
2000
GAIN = 64
GAIN = 4
10
125.9
20.6
20.5
3.1
10
106.7
17.4
186.2
28.2
25
123.1
20.1
28.4
4.3
25
102.9
16.8
288.4
43.7
101.9
16.6
325.8
49.4
30
121.8
19.9
32.8
5.0
30
50
119.9
19.6
40.9
6.2
50
98.5
16.1
479.8
72.7
98.9
16.1
459.8
69.7
60
119.9
19.6
40.9
6.2
60
100
116.1
19.0
63.2
9.6
100
96.3
15.7
620.2
94.0
250
105.7
17.3
209.7
31.8
250
85.5
13.9
2133.5
323.3
78.1
12.7
5025.0
761.4
500
96.6
15.8
597.8
90.6
500
1000
84.3
13.7
2469.5
374.2
1000
66.7
10.8
18693.5
2832.3
2372.1
2000
50.5
8.1
120163.0
18206.5
54.0
2000
68.2
11.0
15656.1
GAIN = 128
GAIN = 8
10
124.7
20.4
23.4
3.5
10
101.1
16.5
356.5
25
120.6
19.7
37.8
5.7
25
96.0
15.7
638.3
96.7
95.2
15.5
704.8
106.8
93.2
15.2
882.2
133.7
30
119.2
19.5
44.3
6.7
30
50
117.5
19.2
53.8
8.2
50
60
116.8
19.1
58.6
8.9
60
92.2
15.0
996.7
151.0
91.4
14.9
1086.6
164.6
100
112.1
18.3
100.0
15.2
100
250
101.4
16.5
345.2
52.3
250
79.4
12.9
4346.4
658.5
71.8
11.6
10439.2
1581.7
500
95.3
15.5
691.1
104.7
500
1000
83.1
13.5
2838.6
430.1
1000
60.1
9.7
39923.0
6048.9
2347.7
2000
44.8
7.1
233238.2
35339.1
2000
68.3
11.1
15494.7
1903
HI7191
Definitions
Integral Non-Linearity, INL, is the maximum deviation of
any digital code from a straight line passing through the endpoints of the transfer function. The endpoints of the transfer
function are zero scale (a point 0.5 LSB below the first code
transition 000...000 and 000...001) and full scale (a point 0.5
LSB above the last code transition 111...110 to 111...111).
Differential Non-Linearity, DNL, is the deviation from the
actual difference between midpoints and the ideal difference
between midpoints (1 LSB) for adjacent codes. If this difference is equal to or more negative than 1 LSB, a code will be
missed.
Offset Error, VOS , is the deviation of the first code transition
from the ideal input voltage (VIN - 0.5 LSB). This error can
be calibrated to the order of the noise level shown in Table 1.
Full Scale Error, FSE, is the deviation of the last code
transition from the ideal input full scale voltage
(VIN- + VREF/Gain - 1.5 LSB). This error can be calibrated
to the order of the noise level shown in Table 1.
Input Span, defines the minimum and maximum input
voltages the device can handle while still calibrating properly
for gain.
Noise, eN , Table 1 shows the peak-to-peak and RMS noise
for typical notch and -3dB frequencies. The device programming was for bipolar input with a VREF of +2.5V. This implies
the input range is 5V. The analysis was performed on 100
conversions with the peak-to-peak output noise being the
difference between the maximum and minimum readings
over a rolling 10 conversion window. The equation to convert
the peak-to-peak noise data to ENOB is:
ENOB = Log2 (VFS / VNRMS)
where: VFS = 5V, VNRMS = VNP-P / CF and
CF = 6.6 (Imperical Crest Factor)
The noise from the part comes from two sources, the
quantization noise from the analog-to-digital conversion process and device noise. Device noise (or Wideband Noise) is
independent of gain and essentially flat across the frequency
spectrum. Quantization noise is ratiometric to input full scale
(and hence gain) and its frequency response is shaped by
the modulator.
do post-filtering (such as brick wall filtering) on the data to
improve the overall resolution for a given -3dB frequency and
also to further reduce the output noise.
Circuit Description
The HI7191 is a monolithic, sigma delta A/D converter which
operates from ±5V supplies and is intended for
measurement of wide dynamic range, low frequency signals.
It contains a Programmable Gain Instrumentation Amplifier
(PGIA), sigma delta ADC, digital filter, bidirectional serial
port (compatible with many industry standard protocols),
clock oscillator, and an on-chip controller.
The signal and reference inputs are fully differential for
maximum flexibility and performance. Normally VRHI and
VRLO are tied to +2.5V and AGND respectively. This allows
for input ranges of 2.5V and 5V when operating in the unipolar and bipolar modes respectively (assuming the PGIA is
configured for a gain of 1). The internal PGIA provides input
gains from 1 to 128 and eliminates the need for external preamplifiers. This means the device will convert signals ranging from 0V to +20mV and 0V to +2.5V when operating in
the unipolar mode or signals in the range of ±20mV to ±2.5V
when operating in the bipolar mode.
The input signal is continuously sampled at the input to the
HI7191 at a clock rate set by the oscillator frequency and the
selected gain. This signal then passes through the sigma
delta modulator (which includes the PGIA) and emerges as
a pulse train whose code density contains the analog signal
information. The output of the modulator is fed into the sinc3
digital low pass filter. The filter output passes into the
calibration block where offset and gain errors are removed.
The calibrated data is then coded (2’s complement, offset
binary or binary) before being stored in the Data Output
Register. The Data Output Register update rate is determined by the first notch frequency of the digital filter. This
first notch frequency is programmed into HI7191 via the
Control Register and has a range of 10Hz to 1.953kHz which
corresponds to -3dB frequencies of 2.62Hz and 512Hz
respectively.
Output data coding on the HI7191 is programmable via the
Control Register. When operating in bipolar mode, data output can be either 2’s complement or offset binary. In unipolar
mode output is binary.
Looking at Table 1, as the cutoff frequency increases the
output noise increases. This is due to more of the
quantization noise of the part coming through to the output
and, hence, the output noise increases with increasing 3dB frequencies. For the lower notch settings, the output
noise is dominated by the device noise and, hence, altering
the gain has little effect on the output noise. At higher notch
frequencies, the quantization noise dominates the output
noise and, in this case, the output noise tends to decrease
with increasing gain.
The DRDY signal is used to alert the user that new output
data is available. Converted data is read via the HI7191
serial I/O port which is compatible with most synchronous
transfer formats including both the Motorola 6805/11 series
SPI and Intel 8051 series SSR protocols. Data Integrity is
always maintained at the HI7191 output port. This means
that if a data read of conversion N is begun but not finished
before the next conversion (conversion N + 1) is complete,
the DRDY line remains active (low) and the data being read
is not overwritten.
Since the output noise comes from two sources, the effective
resolution of the device (i.e., the ratio of the input full scale to
the output RMS noise) does not remain constant with
increasing gain or with increasing bandwidth. It is possible to
The HI7191 provides many calibration modes that can be
initiated at any time by writing to the Control Register. The
device can perform system calibration where external components are included with the HI7191 in the calibration loop
1904
HI7191
or self-calibration where only the HI7191 itself is in the calibration loop. The On-chip Calibration Registers are
read/write registers which allow the user to read calibration
coefficients as well as write previously determined
calibration coefficients.
Circuit Operation
The analog and digital supplies and grounds are separate
on the HI7191 to minimize digital noise coupling into the
analog circuitry. Nominal supply voltages are AVDD = +5V,
DVDD = +5V, and AVSS = -5V. If the same supply is used
for AVDD and DVDD it is imperative that the supply is separately decoupled to the AVDD and DVDD pins on the
HI7191. Separate analog and digital ground planes should
be maintained on the system board and the grounds should
be tied together back at the power supply.
When the HI7191 is powered up it needs to be reset by pulling the RESET line low. The reset sets the internal registers
of the HI7191 as shown in Table 2 and puts the part in the
bipolar mode with a gain of 1 and offset binary coding. The
filter notch of the digital filter is set at 30Hz while the I/O is
set up for bidirectional I/O (data is read and written on the
SDIO line and SDO is three-stated), descending byte order,
and MSB first data format. A self calibration is performed
before the device begins converting. DRDY goes low when
valid data is available at the output.
TABLE 2. REGISTER RESET VALUES
REGISTER
XXXX (Undefined)
Control Register
28B300
Offset Calibration Register
Self Calibration Value
Positive Full Scale Calibration
Register
Self Calibration Value
Negative Full Scale Calibration
Register
Self Calibration Value
The calibration registers can be read via the serial interface
at any time. However, care must be taken when writing data
to the calibration registers. If the HI7191 is internally
updating any calibration register the user can not write to
that calibration register. See the Operational Modes section
for details on which calibration registers are updated for the
various modes.
Since access to the calibration registers is asynchronous to
the conversion process the user is cautioned that new
calibration data may not be used on the very next set of
“valid” data after a calibration register write. It is guaranteed
that the new data will take effect on the second set of output
data. Non-calibrated data can be obtained from the device
by writing 000000 (h) to the Offset Calibration Register,
800000 (h) to the Positive Full Scale Calibration Register,
and 800000 (h) to the Negative Full Scale Calibration Register. This sets the offset correction factor to 0 and the positive
and negative gain slope factors to 1.
If several HI7191s share a system master clock the SYNC
pin can be used to synchronize their operation. A common
SYNC input to multiple devices will synchronize operation
such that all output registers are updated simultaneously. Of
course the SYNC pin would normally be activated only after
each HI7191 has been calibrated or has had calibration
coefficients written to it.
The SYNC pin can also be used to control the HI7191 when
an external multiplexer is used with a single HI7191. The
SYNC pin in this application can be used to guarantee a maximum settling time of 3 conversion periods when switching
channels on the multiplexer.
VALUE (HEX)
Data Output Register
part is re-calibrated (if in a calibration mode) before the
DRDY output goes low indicating that valid data is available.
Analog Section Description
The configuration of the HI7191 is changed by writing new
setup data to the Control Register. Whenever data is written
to byte 2 and/or byte 1 of the Control Register the part
assumes that a critical setup parameter is being changed
which means that DRDY goes high and the device is re-synchronized. If the configuration is changed such that the
device is in any one of the calibration modes, a new calibration is performed before normal conversions continue. If the
device is written to the conversion mode, a new calibration is
NOT performed (A new calibration is recommended any time
data is written to the Control Register.). In either case, DRDY
goes low when valid data is available at the output.
Figure 6 shows a simplified block diagram of the analog
modulator front end of a sigma delta A/D Converter. The
input signal VIN comes into a summing junction (the PGIA in
this case) where the previous modulator output is subtracted
from it. The resulting signal is then integrated and the output
of the integrator goes into the comparator. The output of the
comparator is then fed back via a 1-bit DAC to the summing
junction. The feedback loop forces the average of the fed
back signal to be equal to the input signal VIN .
If a single data byte is written to byte 0 of the Control
Register, the device assumes the gain has NOT been
changed. It is up to the user to re-calibrate the device if the
gain is changed in this manner. For this reason it is
recommended that the entire Control Register be written
when changing the gain of the device. This ensures that the
1905
PGIA
+
VIN
-
INTEGRATOR
∑
∫
COMPARATOR
+
-
DAC
VRHI
VRLO
FIGURE 6. SIMPLE MODULATOR BLOCK DIAGRAM
HI7191
Analog Inputs
Differential Reference Input
The analog input on the HI7191 is a fully differential input
with programmable gain capabilities. The input accepts both
unipolar and bipolar input signals and gains range from 1 to
128. The common mode range of this input is from AVSS to
AVDD provided that the absolute value of the analog input
voltage lies within the power supplies. The input impedance
of the HI7191 is dependent upon the modulator input sampling rate and the sampling rate varies with the selected
PGIA gain. Table 3 below shows the sampling rates and
input impedances for the different gain settings of the
HI7191. Note that this table is valid only for a 10MHz master
clock. If the input clock frequency is changed then the input
impedance will change accordingly. The equation used to
calculate the input impedance is:
The reference inputs of the of the HI7191, VRHI and VRLO ,
provide a differential reference input capability. The nominal
differential voltage (VREF = VRHI - VRLO) is +2.5V and the
common mode voltage cab be anywhere between AVSS and
AVDD . Larger values of VREF can be used without
degradation in performance with the maximum reference
voltage being VREF = +5V. Smaller values of VREF can also
be used but performance will be degraded since the LSB
size is reduced.
ZIN = 1/(CIN x fS),
and VRHI must always be greater than VRLO for proper
operation of the device.
where Cin is the nominal input capacitance (8pF) and fS is
the modulator sampling rate.
TABLE 3. EFFECTIVE INPUT IMPEDANCE vs GAIN
GAIN
SAMPLING RATE INPUT IMPEDANCE
(kHz)
(MΩ)
1
78.125
1.6
2
156.25
0.8
4
312.5
0.4
8, 16, 32, 64, 128
625
0.2
The full scale range of the HI7191 is defined as:
FSRBIPOLAR = 2 x VREF /GAIN
FSRUNIPOLAR = VREF /GAIN
The reference inputs provide a high impedance dynamic
load similar to the analog inputs and the effective input
impedance for the reference inputs can be calculated in the
same manner as it is for the analog input impedance. The
only difference in the calculation is that CIN for the reference
inputs is 10.67pF. Therefor, the input impedance range for
the reference inputs is from 149kΩ in a gain of 8 or higher
mode to 833kΩ in the gain of 1 mode.
VCM Input
Bipolar/Unipolar Input Ranges
The input on the HI7191 can accept either unipolar or bipolar
input voltages. Bipolar or unipolar options are chosen by programming the B/U bit of the Control Register. Programming
the part for either unipolar or bipolar operation does not
change the input signal conditioning.
The inputs are differential, and as a result are referenced to
the voltage on the VINLO input. For example, if VINLO is
+1.25V and the HI7191 is configured for unipolar operation
with a gain of 1 and a VREF of +2.5V, the input voltage range
on the VINLO input is +1.25V to +3.75V. If VINLO is +1.25V
and the HI7191 is configured for bipolar mode with gain of 1
and a VREF of +2.5V, the analog input range on the VINHI
input is -1.25V to +3.75V.
Programmable Gain Instrumentation Amplifier
The Programmable Gain Instrumentation Amplifier allows the
user to directly interface low level sensors and bridges directly
to the HI7191. The PGIA has 4 selectable gain options of 1, 2,
4, 8 which are implemented by multiple sampling of the input
signal. Input signals can be gained up further to 16, 32, 64 or
128. These higher gains are implemented in the digital section
of the design to maintain a high signal to noise ratio through
the front end amplifiers. The gain is digitally programmable in
the Control Register via the serial interface. For optimum
PGIA performance the VCM pin should be tied to the mid point
of the analog supplies.
The voltage at the VCM input is the voltage that the internal
analog circuitry is referenced to and should always be tied to
the midpoint of the AVDD and AVSS supplies. This point
provides a common mode input voltage for the internal operational amplifiers and must be driven from a low noise, low
impedance source if it is not tied to analog ground. Failure to
do so will result in degraded HI7191 performance. It is
recommended that VCM be tied to analog ground when
operating off of AVDD = +5V and AVSS = -5V supplies.
VCM also determines the headroom at the upper and lower
ends of the power supplies which is limited by the common
mode input range where the internal operational amplifiers
remain in the linear, high gain region of operation. The
HI7191 is designed to have a range of AVSS +1.8V < VCM <
AVDD - 1.8V. Exceeding this range on the VCM pin will
compromise the device performance.
Transducer Burn-Out Current Source
The VINHI input of the HI7191 contains a 500nA (Typ) current
source which can be turned on/off via the Control Register.
This current source can be used in checking whether a transducer has burnt-out or become open before attempting to take
measurements on that channel. When the current source is
turned on an additional offset will be created indicating the
presence of a transducer. The current source is controlled by
the BO bit (Bit 4) in the Control Register and is disabled on
power up. See Figure 8 for an applications circuit.
1906
HI7191
Low Pass Decimation Filter
HI7191
The digital low-pass filter is a Hogenauer (sinc3) decimating
filter. This filter was chosen because it is a cost effective low
pass decimating filter that minimizes the need for internal
multipliers and extensive storage and is most effective when
used with high sampling or oversampling rates. Figure 10
shows the frequency characteristics of the filter where fC is
the -3dB frequency of the input signal and fN is the
programmed notch frequency. The analog modulator sends
a one bit data stream to the filter at a rate of that is
determined by:
AVDD
RATIOMETRIC
CONFIGURATION
CURRENT
SOURCE
LOAD CELL
VRHI
VRLO
VINHI
fMODULATOR = fOSC/128
fMODULATOR = 78.125kHz for fOSC = 10MHz.
VINLO
The filter then converts the serial modulator data into 40-bit
words for processing by the Hogenauer filter. The data is
decimated in the filter at a rate determined by the CODE
word FP10-FP0 (programed by the user into the Control
Register) and the external clock rate. The equation is:
AVSS
FIGURE 7. BURN-OUT CURRENT SOURCE CIRCUIT
fNOTCH = fOSC /(512 x CODE).
Digital Section Description
A block diagram of the digital section of the HI7191 is shown
in Figure 9. This section includes a low pass decimation filter, conversion controller, calibration logic, serial interface,
and clock generator.
MODULATOR OUTPUT
MODULATOR
CLOCK
DIGITAL
FILTER
SYNC
CLOCK
GENERATOR
CALIBRATION
AND CONTROL
SERIAL I/O
OSC2
OSC1
SDO
SDIO
SCLK
CS
DRDY
RESET
FIGURE 8. DIGITAL SECTION BLOCK DIAGRAM
Digital Filtering
One advantage of digital filtering is that it occurs after the
conversion process and can remove noise introduced during
the conversion. It can not, however, remove noise present on
the analog signal prior to the ADC (which an analog filter
can).
One problem with the modulator/digital filter combination is
that excursions outside the full scale range of the device
could cause the modulator and digital filter to saturate. This
device has headroom built in to the modulator and digital filter which tolerates signal deviations up to 33% outside of the
full scale range of the device. If noise spikes can drive the
input signal outside of this extended range, it is recommended that an input analog filter is used or the overall input
signal level is reduced.
The Control Register has 11 bits that select the filter cutoff
frequency and the first notch of the filter. The output data
update rate is equal to the notch frequency. The notch frequency sets the Nyquist sampling rate of the device while
the -3dB point of the filter determines the frequency spectrum of interest (fS). The FP bits have a usable range of 10
through 2047 where 10 yields a 1.953kHz Nyquist rate.
The Hogenauer filter contains alias components that reflect
around the notch frequency. If the spectrum of the frequency
of interest reaches the alias component, the data has been
aliased and therefore undersampled.
Filter Characteristics
Please note: We have recently discovered a performance
anomaly with the HI7191. The problem occurs when the
digital code for the notch filter is programmed within
certain frequencies. We believe the error is caused by
the calibration logic and the digital notch code NOT the
absolute frequency. The error is seen when the user
applies mid-scale (0V input, Bipolar mode). With this
input, the expected digital output should be mid-scale
(800000h). Instead, there is a small probability, of an
erroneous negative full scale (000000h)output. Refer to
Technical Brief TB348 for complete details.
The FP10 to FP0 bits programmed into the Control Register
determine the cutoff (or notch) frequency of the digital filter.
The allowable code range is 00AH . This corresponds to a
maximum and minimum cutoff frequency of 1.953kHz and
10Hz, respectively when operating at a clock frequency of
10MHz. If a 1MHz clock is used then the maximum and minimum cutoff frequencies become 195.3kHz and 1Hz, respectively. A plot of the (sinx/x)3 digital filter characteristics is
shown in Figure 10. This filter provides greater than 120dB
of 50Hz or 60Hz rejection. Changing the clock frequency or
the programming of the FP bits does not change the shape
of the filter characteristics, it merely shifts the notch frequency. This low pass digital filter at the output of the con-
1907
HI7191
verter has an accompanying settling time for step inputs just
as a low pass analog filter does. New data takes between 3
and 4 conversion periods to settle and update on the serial
port with a conversion period tCONV being equal to 1/fN .
Please note that the HI7191 specifications are written for a
10MHz clock only.
10MHz
17
0
ALIAS BAND
fN ±fC
OSC1
16
HI7191
OSC2
AMPLITUDE (dB)
-20
-40
FIGURE 10A.
-60
10MHz
NO
CONNECTION
-80
-100
17
OSC1
-120
fC
fN
2fN
3fN
16
HI7191
OSC2
4fN
FREQUENCY (Hz)
FIGURE 10B.
FIGURE 9. LOW PASS FILTER FREQUENCY CHARACTERISTICS
FIGURE 10. OSCILLATOR CONFIGURATIONS
Input Filtering
The digital filter does not provide rejection at integer multiples of the modulator sampling frequency. This implies that
there are frequency bands where noise passes to the output
without attenuation. For most cases this is not a problem
because the high oversampling rate and noise shaping characteristics of the modulator cause this noise to become a
small portion of the broadband noise which is filtered. However, if an anti-alias filter is necessary a single pole RC filter
is usually sufficient.
If an input filter is used the user must be careful that the
source impedance of the filter is low enough not to cause
gain errors in the system. The DC input impedance at the
inputs is > 1GΩ but it is a dynamic load that changes with
clock frequency and selected gain. The input sample rate,
also dependent upon clock frequency and gain, determines
the allotted time for the input capacitor to charge. The addition of external components may cause the charge time of
the capacitor to increase beyond the allotted time. The result
of the input not settling to the proper value is a system gain
error which can be eliminated by system calibration of the
HI7191.
Clocking/Oscillators
The master clock into the HI7191 can be supplied by either a
crystal connected between the OSC1 and OSC2 pins as
shown in Figure 11A or a CMOS compatible clock signal
connected to the OSC1 pin as shown in Figure 11B. The
input sampling frequency, modulator sampling frequency, filter -3dB frequency, output update rate, and calibration time
are all directly related to the master clock frequency, fOSC .
For example, if a 1MHz clock is used instead of a 10MHz
clock, what is normally a 10Hz conversion rate becomes a
1Hz conversion rate. Lowering the clock frequency will also
lower the amount of current drawn from the power supplies.
Operational Modes
The HI7191 contains several operational modes including
calibration modes for cancelling offset and gain errors of
both internal and external circuitry. A calibration routine
should be initiated whenever there is a change in the ambient operating temperature or supply voltage. Calibration
should also be initiated if there is a change in the gain, filter
notch, bipolar, or unipolar input range. Non-calibrated data
can be obtained from the device by writing 000000 to the
Offset Calibration Register, 800000 (h) to the Positive Full
Scale Calibration Register, and 800000 (h) to the Negative
Full Scale Calibration Register. This sets the offset
correction factor to 0 and both the positive and negative gain
slope factors to 1.
The HI7191 offers several different modes of Self-Calibration
and System Calibration. For calibration to occur, the on-chip
microcontroller must convert the modulator output for three
different input conditions - “zero-scale,” “positive full scale,”
and “negative full scale”. With these readings, the HI7191
can null any offset errors and calculate the gain slope factor
for the transfer function of the converter. It is imperative that
the zero-scale calibration be performed before either of the
gain calibrations. However, the order of the gain calibrations
is not important.
The calibration modes are user selectable in the Control
Register by using the MD bits (MD2-MD0) as shown in
Table 6. DRDY will go low indicating that the calibration is
complete and there is valid data at the output.
1908
HI7191
MD2
MD1
MD0
0
0
0
Conversion
signal to settle before selecting this mode. After 4 conversion periods the DRDY line will activate signaling that the
calibration is complete and valid data is present in the Data
Output Register.
0
0
1
Self Calibration (Gain of 1 only)
System Positive Full Scale Calibration Mode
0
1
0
System Offset Calibration
0
1
1
System Positive Full Scale Calibration
1
0
0
System Negative Full Scale Calibration
1
0
1
System Offset/Internal Gain Calibration
(Gain of 1 only)
1
1
0
System Gain Calibration
1
1
1
Reserved
The System Positive Full Scale Calibration Mode is a single
step process that allows the user to lump gain errors of
external circuitry and the internal errors of the HI7191
together and null them out. This mode will convert the external differential signal applied to the VIN inputs and stores the
converted value in the Positive Full Scale Calibration Register. The user must apply the +Full Scale voltage to the
HI7191 analog inputs and allow the signal to settle before
selecting this mode. After 4 conversion periods the DRDY
line will activate signaling the calibration is complete and
valid data is present in the Data Output Register.
TABLE 4. HI7191 OPERATIONAL MODES
OPERATIONAL MODE
Conversion Mode
For Conversion Mode operation the HI7191 converts the differential voltage between VINHI and VINLO . From switching
into this mode it takes 3 conversion periods (3 x 1/fN) for
DRDY to go low and new data to be valid. No calibration
coefficients are generated when operating in Conversion
Mode as data is calibrated using the existing calibration
coefficients.
Self-Calibration Mode
Please note: Self-calibration is only valid when operating
in a gain of one. In addition, the offset and gain errors are
not reduced as with the full system calibration.
The Self-Calibration Mode is a three step process that
updates the Offset Calibration Register, the Positive Full
Scale Calibration Register, and the Negative Full Scale Calibration Register. In this mode an internal offset calibration is
done by disconnecting the external inputs and shorting the
inputs of the PGIA together. After 3 conversion periods the
Offset Calibration Register is updated with the value that
corrects any internal offset errors.
After the offset calibration is completed the Positive and
Negative Full Scale Calibration Registers are updated. The
inputs VINHI and VINLO are disconnected and the external
reference is applied across the modulator inputs. The
HI7191 then takes 3 conversion cycles to sample the data
and update the Positive Full Scale Calibration Register. Next
the polarity of the reference voltage across the modulator
input terminals is reversed and after 3 conversion cycles the
Negative Full Scale Calibration Register is updated. The
values stored in the Positive and Negative Full Scale
Calibration Registers correct for any internal gain errors in
the A/D transfer function. After 3 more conversion cycles the
DRDY line will activate signaling that the calibration is complete and valid data is present in the Data Output Register.
System Offset Calibration Mode
The System Offset Calibration Mode is a single step process
that allows the user to lump offset errors of external circuitry
and the internal errors of the HI7191 together and null them
out. This mode will convert the external differential signal
applied to the VIN inputs and then store that value in the Offset Calibration Register. The user must apply the zero point
or offset voltage to the HI7191 analog inputs and allow the
System Negative Full Scale Calibration Mode
The System Negative Full Scale Calibration Mode is a
single-step process that allows the user to lump gain errors
of external circuitry and the internal errors of the HI7191
together and null them out. This mode will convert the external differential signal applied to the VIN inputs and stores the
converted value in the Negative Full Scale Calibration Register. The user must apply the -Full Scale voltage to the
HI7191 analog inputs and allow the signal to settle before
selecting this mode. After 4 conversion periods the DRDY
line will activate signaling the calibration is complete and
valid data is present in the Data Output Register.
System Offset/Internal Gain Calibration Mode
Please note: System Offset/Internal Gain is only valid
when operating in a gain of one. In addition, the offset and
gain errors are not reduced as with the full system calibration.
The System Offset/Internal Gain Calibration Mode is a single
step process that updates the Offset Calibration Register,
the Positive Full Scale Calibration Register, and the Negative
Full Scale Calibration Register. First the external differential
signal applied to the VIN inputs is converted and that value is
stored in the Offset Calibration Register. The user must
apply the zero point or offset voltage to the HI7191 analog
inputs and allow the signal to settle before selecting this
mode.
After this is completed the Positive and Negative Full Scale
Calibration Registers are updated. The inputs VINHI and VINLO
are disconnected and the external reference is switched in. The
HI7191 then takes 3 conversion cycles to sample the data and
update the Positive Full Scale Calibration Register. Next the
polarity of the reference voltage across the VINHI and VINLO
terminals is reversed and after 3 conversion cycles the
Negative Full Calibration Register is updated. The values
stored in the Positive and Negative Full Scale Calibration
Registers correct for any internal gain errors in the A/D transfer
function. After 3 more conversion cycles, the DRDY line will
activate signaling that the calibration is complete and valid data
is present in the Data Output Register.
1909
HI7191
System Gain Calibration Mode
The Gain Calibration Mode is a single step process that
updates the Positive and Negative Full Scale Calibration Registers. This mode will convert the external differential signal
applied to the VIN inputs and then store that value in the Negative Full Scale Calibration Register. Then the polarity of the
input is reversed internally and another conversion is performed. This conversion result is written to the Positive Full
Scale Calibration Register. The user must apply the +Full
Scale voltage to the HI7191 analog inputs and allow the signal
to settle before selecting this mode. After 1 more conversion
period the DRDY line will activate signaling the calibration is
complete and valid data is present in the data output register.
Reserved
This mode is not used in the HI7191 and should not be
selected. There is no internal detection logic to keep this
condition from being selected and care should be taken not
to assert this bit combination.
Offset and Span Limits
There are limits to the amount of offset and gain which can
be adjusted out for the HI7191. For both bipolar and unipolar
modes the minimum and maximum input spans are
0.2 x VREF /GAIN and 1.2 x VREF /GAIN respectively.
In the unipolar mode the offset plus the span cannot exceed
the 1.2 x VREF /GAIN limit. So, if the span is at its minimum
value of 0.2 x VREF /GAIN, the offset must be less than 1 x
VREF /GAIN. In bipolar mode the span is equidistant around
the voltage used for the zero scale point. For this mode the
offset plus half the span cannot exceed 1.2 x VREF /GAIN. If
the span is at ±0.2 x VREF /GAIN, then the offset can not be
greater than ±2 x VREF /GAIN.
Serial Interface
The HI7191 has a flexible, synchronous serial communication
port to allow easy interfacing to many industry standard microcontrollers and microprocessors. The serial I/O is compatible
with most synchronous transfer formats, including both the
Motorola 6805/11 SPI and Intel 8051 SSR protocols. The
Serial Interface is a flexible 2-wire or 3-wire hardware interface
where the HI7191 can be configured to read and write on a
single bidirectional line (SDIO) or configured for writing on
SDIO and reading on the SDO line.
The interface is byte organized with each register byte
having a specific address and single or multiple byte transfers are supported. In addition, the interface allows flexibility
as to the byte and bit access order. That is, the user can
specify MSB/LSB first bit positioning and can access bytes
in ascending/descending order from any byte position.
The serial interface allows the user to communicate with 5
registers that control the operation of the device.
Data Output Register - a 24-bit, read only register
containing the conversion results.
Control Register - a 24-bit, read/write register containing
the setup and operating modes of the device.
Offset Calibration Register - a 24-bit, read/write register
used for calibrating the zero point of the converter or system.
Positive Full Scale Calibration Register - a 24-bit,
read/write register used for calibrating the Positive Full Scale
point of the converter or system.
Negative Full Scale Calibration Register - a 24-bit,
read/write register used for calibrating the Negative Full
Scale point of the converter or system.
Two clock modes are supported. The HI7191 can accept the
serial interface clock (SCLK) as an input from the system or
generate the SCLK signal as an output. If the MODE pin is
logic low the HI7191 is in external clocking mode and the
SCLK pin is configured as an input. In this mode the user
supplies the serial interface clock and all interface timing
specifications are synchronous to this input. If the MODE pin
is logic high the HI7191 is in self-clocking mode and the
SCLK pin is configured as an output. In self-clocking mode,
SCLK runs at FSCLK = OSC1 /8 and stalls high at byte
boundaries. SCLK does NOT have the capability to stall low
in this mode. All interface timing specifications are
synchronous to the SCLK output.
Normal operation in self-clocking mode is as follows (See
Figure 13): CS is sampled low on falling OSC1 edges. The
first SCLK transition output is delayed 29 OSC1 cycles from
the next rising OSC1. SCLK transitions eight times and then
stalls high for 28 OSC1 cycles. After this stall period is completed SCLK will again transition eight times and stall high.
This sequence will repeat continuously while CS is active.
The extra OSC1 cycle required when coming out of the CS
inactive state is a one clock cycle latency required to properly sample the CS input. Note that the normal stall at byte
boundaries is 28 OSC1 cycles thus giving a SCLK rising to
rising edge stall period of 32 OSC1 cycles.
The affects of CS on the I/O are different for self-clocking
mode (MODE = 1) than for external mode (MODE = 0). For
external clocking mode CS inactive disables the I/O state
machine, effectively freezing the state of the I/O cycle. That
is, an I/O cycle can be interrupted using chip select and the
HI7191 will continue with that I/O cycle when re-enabled via
CS. SCLK can continue toggling while CS is inactive. If CS
goes inactive during an I/O cycle, it is up to the user to
ensure that the state of SCLK is identical when reactivating
CS as to what it was when CS went inactive. For read operations in external clocking mode, the output will go three-state
immediately upon deactivation of CS.
For self-clocking mode (MODE = 1), the affects of CS are
different. If CS transitions high (inactive) during the period
when data is being transferred (any non stall time) the HI7191
will complete the data transfer to the byte boundary. That is,
once SCLK begins the eight transition sequence, it will always
complete the eight cycles. If CS remains inactive after the byte
has been transferred it will be sampled and SCLK will remain
stalled high indefinitely. If CS has returned to active low before
the data byte transfer period is completed the HI7191 acts as
if CS was active during the entire transfer period.
1910
HI7191
It is important to realize that the user can interrupt a data
transfer on byte boundaries. That is, if the Instruction Register calls for a 3 byte transfer and CS is inactive after only one
byte has been transferred, the HI7191, when reactivated, will
continue with the remaining two bytes before looking for the
next Instruction Register write cycle.
Note that the outputs will NOT go three-state immediately upon
CS inactive for read operations in self-clocking mode. In the
case of CS going inactive during a read cycle the outputs
remain driving until after the last data bit is transferred. In the
case of CS inactive during the clock stall time it takes 1 OSC1
cycle plus prop delay (Max) for the outputs to be disabled.
I/O Port Pin Descriptions
The serial I/O port is a bidirectional port which is used to
read the data register and read or write the control register
and calibration registers. The port contains two data lines, a
synchronous clock, and a status flag. Figure 12 shows a
diagram of the serial interface lines.
DATA OUT
BIDIRECTIONAL DATA
SDO
SDIO
SCLK
HI7191
CS
DRDY
MODE
PORT CLOCK
CHIP SELECT
DEVICE STATUS
CLOCK MODE
SDO - Serial Data out. Data is read from this line using those
protocols with separate lines for transmitting and receiving
data. An example of such a standard is the Motorola Serial
Peripheral Interface (SPI) using the 68HC05 and 68HC11
family of microcontrollers, or other similar processors. In the
case of using bidirectional data transfer on SDIO, SDO does
not output data and is set in a high impedance state.
SDIO - Serial Data in or out. Data is always written to the
device on this line. However, this line can be used as a bidirectional data line. This is done by properly setting up the
Control Register. Bidirectional data transfer on this line can
be used with Intel standard serial interfaces (SSR, Mode 0)
in MCS51 and MCS96 family of microcontrollers, or other
similar processors.
SCLK - Serial clock. The serial clock pin is used to synchronize data to and from the HI7191 and to run the port state
machines. In Synchronous External Clock Mode, SCLK is
configured as an input, is supplied by the user, and can run
up to a 5MHz rate. In Synchronous Self Clocking Mode,
SCLK is configured as an output and runs at OSC1/8.
33
DRDY - Data Ready. This is an output status flag from the
device to signal that the Data Output Register has been
updated with the new conversion result. DRDY is useful as an
edge or level sensitive interrupt signal to a microprocessor or
microcontroller. DRDY low indicates that new data is available
at the Data Output Register. DRDY will return high upon
completion of a complete Data Output Register read cycle.
MODE - Mode. This input is used to select between Synchronous Self Clocking Mode (‘1’) or the Synchronous External
Clocking Mode (‘0’). When this pin is tied to VDD the serial
port is configured in the Synchronous Self Clocking mode
where the synchronous shift clock (SCLK) for the serial port is
generated by the HI7191 and has a frequency of OSC1/8.
When the pin is tied to DGND the serial port is configured for
the Synchronous External Clocking Mode where the synchronous shift clock for the serial port is generated by an external
device up to a maximum frequency of 5MHz.
Programming the Serial Interface
FIGURE 11. HI7191 SERIAL INTERFACE
29
CS - Chip select. This signal is an active low input that
allows more than one device on the same serial communication lines. The SDO and SDIO will go to a high impedance
state when this signal is high. If driven high during any
communication cycle, that cycle will be suspended until CS
reactivation. Chip select can be tied low in systems that
maintain control of SCLK.
37
It is useful to think of the HI7191 interface in terms of
communication cycles. Each communication cycle happens
in 2 phases. The first phase of every communication cycle
is the writing of an instruction byte. The second phase is
the data transfer as described by the instruction byte. It is
important to note that phase 2 of the communication cycle
can be a single byte or a multi-byte transfer of data. For
example, the 3-byte Data Output Register can be read
using one multi-byte communication cycle rather than three
single-byte communication cycles. It is up to the user to
maintain synchronism with respect to data transfers. If the
system processor “gets lost” the only way to recover is to
reset the HI7191. Figure 14 shows both a 2-wire and a
3-wire data transfer.
Several formats are available for reading from and writing to
the HI7191 registers in both the 2-wire and 3-wire protocols.
A portion of these formats is controlled by the CR<2:1> (BD
and MSB) bits which control the byte direction and bit order
of a data transfer respectively. These two bits can be written
in any combination but only the two most useful will be discussed here.
41
45
89
OSC1
CS
SCLK
FIGURE 12. SCLK OUTPUT IN SELF-CLOCKING MODE
1911
121
125
HI7191
The first combination is to reset both the BD and MSB bits
(BD = 0, MSB = 0). This sets up the interface for descending
byte order and MSB first format. When this combination is
used the user should always write the Instruction Register
such that the starting byte is the most significant byte address.
For example, read three bytes of DR starting with the most significant byte. The first byte read will be the most significant in
MSB to LSB format. The next byte will be the next least significant (recall descending byte order) again in MSB to LSB order.
The last byte will be the next lesser significant byte in MSB to
LSB order. The entire word was read MSB to LSB format.
The second combination is to set both the BD and MSB bits to
1. This sets up the interface for ascending byte order and LSB
first format. When this combination is used the user should
always write the Instruction Register such that the starting
byte is the least significant byte address. For example, read
three bytes of DR starting with the least significant byte. The
first byte read will be the least significant in LSB to MSB format. The next byte will be the next greater significant (recall
ascending byte order) again in LSB to MSB order. The last
byte will be the next greater significant byte in LSB to MSB
order. The entire word was read MSB to LSB format.
Instruction Byte Phase
The instruction byte phase initiates a data transfer
sequence. The processor writes an 8-bit byte (Instruction
Byte) to the Instruction Register. The instruction byte informs
the HI7191 about the Data transfer phase activities and
includes the following information:
- Read or Write cycle
- Number of Bytes to be transferred
- Which register and starting byte to be accessed
Data Transfer Phase
In the data transfer phase, data transfer takes place as set
by the Instruction Register contents. See Write Operation
and Read Operation sections for detailed descriptions.
Instruction Register
The Instruction Register is an 8-bit register which is used
during a communications cycle for setting up read/write
operations.
INSTRUCTION REGISTER
After completion of each communication cycle, The HI7191
interface enters a standby mode while waiting to receive a
new instruction byte.
CS
INSTRUCTION
BYTE
DATA
BYTE 1
DATA
BYTE 2
DATA
BYTE 3
SDIO
INSTRUCTION
CYCLE
DATA TRANSFER
MSB
6
5
4
3
2
1
LSB
R/W
MB1
MB0
FSC
A3
A2
A1
A0
R/W - Bit 7 of the Instruction Register determines whether a
read or write operation will be done following the instruction
byte load. 0 = READ, 1 = WRITE.
MB1, MB0 - Bits 6 and 5 of the Instruction Register determine the number of bytes that will be accessed following the
instruction byte load. See Table 5 for the number of bytes to
transfer in the transfer cycle.
FIGURE 13A. 2-WIRE, 3-BYTE READ OR WRITE TRANSFER
TABLE 5. MULTIPLE BYTE ACCESS BITS
CS
INSTRUCTION
BYTE
SDIO
INSTRUCTION
CYCLE
DATA
BYTE 1
DATA
BYTE 2
DATA
BYTE 3
SDO
DATA TRANSFER
FIGURE 13B. 3-WIRE, 3-BYTE READ TRANSFER
MB1
MB0
DESCRIPTION
0
0
Transfer 1 Byte
0
1
Transfer 2 Bytes
1
0
Transfer 3 Bytes
1
1
Transfer 4 Bytes
FSC - Bit 4 is used to determine whether a Positive Full
Scale Calibration Register I/O transfer (FSC = 0) or a Negative Full Scale Calibration Register I/O transfer (FSC = 1) is
being performed (see Table 6).
A3, A2, A1, A0 - Bits 3 and 2 (A3 and A2) of the Instruction
Register determine which internal register will be accessed
while bits 1 and 0 (A1 and A0) determine which byte of that
register will be accessed first. See Table 6 for the address
decode.
1912
HI7191
TABLE 6. INTERNAL DATA ACCESS DECODE STARTING BYTE
FSC A3 A2 A1 A0
DESCRIPTION
X
0
0
0
0
Data Output Register, Byte 0
X
0
0
0
1
Data Output Register, Byte 1
X
0
0
1
0
Data Output Register, Byte 2
X
0
1
0
0
Control Register, Byte 0
X
0
1
0
1
Control Register, Byte 1
X
0
1
1
0
Control Register, Byte 2
X
1
0
0
0
Offset Cal Register, Byte 0
X
1
0
0
1
Offset Cal Register, Byte 1
X
1
0
1
0
Offset Cal Register, Byte 2
0
1
1
0
0
Positive Full Scale Cal Register, Byte 0
0
1
1
0
1
Positive Full Scale Cal Register, Byte 1
0
1
1
1
0
Positive Full Scale Cal Register, Byte 2
1
1
1
0
0
Negative Full Scale Cal Register, Byte 0
1
1
1
0
1
Negative Full Scale Cal Register, Byte 1
1
1
1
1
0
Negative Full Scale Cal Register, Byte 2
The communication cycle is started by asserting the CS line
and starting the clock from its idle state. To assert a read
cycle, during the instruction phase of the communication
cycle, the Instruction Byte should be set to a read transfer
(R/W = 0).
When reading the serial port, data is driven out of the
HI7191 on the falling edge of SCLK. Data can be registered
externally on the next rising edge of SCLK.
Read Operation - 2-Wire Transfer
Data can be read from the Data Output Register, Control
Register, Offset Calibration Register, Positive Full Scale Calibration Register, and the Negative Full Scale Calibration
Register. When configured in two-wire transfer mode, read
operations are done using the SDIO, CS and SCLK lines. All
data is read via the SDIO line. Figures 19 and 20 show
typical 2-wire read timing diagrams.
The communication cycle is started by asserting the CS line
and starting the clock from its idle state. To assert a read cycle,
during the instruction phase of the communication cycle, the
Instruction Byte should be set to a read transfer (R/W = 0).
When reading the serial port, data is driven out of the
HI7191 on the falling edge of SCLK. Data can be registered
externally on the next rising edge of SCLK.
Detailed Register Descriptions
Write Operation
Data can be written to the Control Register, Offset Calibration Register, Positive Full Scale Calibration Register, and
the Negative Full Scale Calibration Register. Write operations are done using the SDIO, CS and SCLK lines only, as
all data is written into the HI7191 via the SDIO line even
when using the 3-wire configuration. Figures 15 and 16
show typical write timing diagrams.
Data Output Register
The Data Output Register contains 24 bits of converted data.
This register is a read only register.
The communication cycle is started by asserting the CS line
low and starting the clock from its idle state. To assert a write
cycle, during the instruction phase of the communication
cycle, the Instruction Byte should be set to a write transfer
(R/W = 1).
When writing to the serial port, data is latched into the
HI7191 on the rising edge of SCLK. Data can then be
changed on the falling edge of SCLK. Data can also be
changed on the rising edge of SCLK due to the 0ns hold
time required on the data. This is useful in pipelined applications where the data is latched on the rising edge of the
clock.
Read Operation - 3-Wire Transfer
Data can be read from the Data Output Register, Control
Register, Offset Calibration Register, Positive Full Scale
Calibration Register, and the Negative Full Scale Calibration
Register. When configured in 3-wire transfer mode, read
operations are done using the SDIO, SDO, CS and SCLK
lines. All data is read via the SDO line. Figures 17 and 18
show typical 3-wire read timing diagrams.
1913
BYTE 2
MSB
22
21
20
19
18
17
16
D23
D22
D21
D20
D19
D18
D17
D16
BYTE 1
15
14
13
12
11
10
9
8
D15
D14
D13
D12
D11
D10
D9
D8
BYTE 0
7
6
5
4
3
2
1
LSB
D7
D6
D5
D4
D3
D2
D1
D0
HI7191
IR WRITE PHASE
CS
DATA TRANSFER PHASE - TWO-BYTE WRITE
SCLK
SDIO
I0
I1
I2
I3
I4
I5
I6
I7
B0
B1
B2
B3
B4
B5
B6
THREE-STATE
SDO
B7
B8
B9
B10 B11 B12 B13 B14 B15
THREE-STATE
FIGURE 14. DATA WRITE CYCLE, SCLK IDLE LOW
IR WRITE PHASE
DATA TRANSFER PHASE - TWO-BYTE WRITE
CS
SCLK
B15
I0
SDIO
I1
I2
SDO
I3
I4
I5
I6
B0
I7
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10 B11 B12 B13 B14
THREE-STATE
THREE-STATE
FIGURE 15. DATA WRITE CYCLE, SCLK IDLE HIGH
IR WRITE PHASE
CS
DATA TRANSFER PHASE - TWO-BYTE READ
SCLK
SDIO
I0
I1
I2
I3
I4
I5
I6
I7
B15
SDO
B0
B1
B2
B3
B4
B5
B6
B8
B7
B9
B10 B11 B12 B13 B14
FIGURE 16. DATA READ CYCLE, 3-WIRE CONFIGURATION, SCLK IDLE LOW
IR WRITE PHASE
CS
DATA TRANSFER PHASE - TWO-BYTE READ
SCLK
I0
SDIO
I1
I2
I3
I4
I5
I6
I7
B15
B0
SDO
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10 B11 B12 B13 B14
FIGURE 17. DATA READ CYCLE, 3-WIRE CONFIGURATION, SCLK IDLE HIGH
IR WRITE PHASE
CS
DATA TRANSFER PHASE - TWO-BYTE READ
SCLK
B15
SDIO
SDO
I0
I1
I2
I3
I4
I5
I6
I7
B0
B1
B2
B3
THREE-STATE
B4
B5
B6
B7
B8
B9
B10
THREE-STATE
FIGURE 18. DATA READ CYCLE, 2-WIRE CONFIGURATION, SCLK IDLE LOW
1914
B11 B12 B13 B14
HI7191
IR WRITE PHASE
CS
DATA TRANSFER PHASE - TWO-BYTE READ
SCLK
B15
SDIO
I0
I1
I2
SDO
I3
I4
I5
I6
I7
B0
B1
B2
B3
B4
THREE-STATE
B5
B6
B7
B8
B9
B10 B11 B12 B13 B14
THREE-STATE
FIGURE 19. DATA READ CYCLE, 2-WIRE CONFIGURATION, SCLK IDLE HIGH
Control Register
The Control Register contains 24-bits to control the various
sections of the HI7191. This register is a read/write
register.
BYTE 2
MSB
22
21
20
19
18
17
16
DC
FP10
FP9
FP8
FP7
FP6
FP5
FP4
The -3dB frequency is determined by the programmed first
notch frequency according to the relationship:
f -3dB = 0.262 x fNOTCH .
BYTE 1
15
14
13
12
11
10
9
8
FP3
FP2
FP1
FP0
MD2
MD1
MD0
B/U
7
6
5
4
3
2
1
LSB
G2
G1
G0
BO
SB
BD
MSB
SDL
The settling-time of the converter to a full scale step input
change is between 3 and 4 times the data rate. For example,
with the first filter notch at 50Hz, the worst case settling time to
a full scale step input change is 80ms. If the first notch is 1kHz,
the settling time to a full scale input step is 4ms maximum.
MD2 through MD0 - Bits 11 through 9 are the Operational
Modes of the converter. See Table 4 for the Operational
Modes description. After a RESET is applied to the part these
bits are set to the self calibration mode.
BYTE 0
DC - Bit 23 is the Data Coding Bit used to select between
two’s complementary and offset binary data coding. When
this bit is set (DC = 1) the data in the Data Output Register
will be two’s complement. When cleared (DC = 0) this data
will be offset binary. When operating in the unipolar mode
the output data is available in straight binary only (the DC bit
is ignored). This bit is cleared after a RESET is applied to
the part.
FP10 through FP0 - Bits 22 through 12 are the Filter programming bits that determine the frequency response of the
digital filter. These bits determine the filter cutoff frequency,
the position of the first notch and the data rate of the HI7191.
The first notch of the filter is equal to the decimation rate and
can be determined by the formula:
B/U - Bit 8 is the Bipolar/Unipolar select bit. When this bit is
set the HI7191 is configured for bipolar operation. When this
bit is reset the part is in unipolar mode. This bit is set after a
RESET is applied to the part.
G2 through G0 - Bits 7 through 5 select the gain of the input
analog signal. The gain is accomplished through a programmable gain instrumentation amplifier that gains up incoming
signals from 1 to 8. This is achieved by using a switched
capacitor voltage multiplier network preceding the modulator.
The higher gains (i.e., 16 to 128) are achieved through a combination of a PGIA gain of 8 and a digital multiply after the digital filter (see Table 7). The gain will affect noise and Signal to
Noise Ratio of the conversion. These bits are cleared to a gain
of 1 (G2, G1, G0 = 000) after a RESET is applied to the part.
TABLE 7. GAIN SELECT BITS
G2
G1
G0
GAIN
fNOTCH = fOSC /(512 x CODE)
0
0
0
1
PGIA = 1, Filter Multiply = 1
where CODE is the decimal equivalent of the value in FP10
through FP0. The values that can be programmed into these
bits are 10 to 2047 decimal, which allows a conversion rate
range of 9.54Hz to 1.953kHz when using a 10MHz clock.
0
0
1
2
PGIA = 2, Filter Multiply = 1
0
1
0
4
PGIA = 4, Filter Multiply = 1
0
1
1
8
PGIA = 8, Filter Multiply = 1
1
0
0
16
PGIA = 8, Filter Multiply = 2
1
0
1
32
PGIA = 8, Filter Multiply = 4
1
1
0
64
PGIA = 8, Filter Multiply = 8
1
1
1
128
PGIA = 8, Filter Multiply = 16
Changing the filter notch frequency, as well as the selected
gain, impacts resolution. The output data rate (or effective
conversion time) for the device is equal to the frequency
selected for the first notch to the filter. For example, if the first
notch of the filter is selected at 50Hz then a new word is available at a 50Hz rate or every 20ms. If the first notch is at 1kHz
a new word is available every 1ms.
1915
GAIN ACHIEVED
HI7191
BO - Bit 4 is the Transducer Burn-Out Current source enable
bit. When this bit is set (BO = 1) the burn-out current source
connected to VINHI internally is enabled. This current source
can be used to detect the presence of an external connection
to VINHI . This bit is cleared after a RESET is applied to the
part.
1) A Data Output Register read cycle is started for a given
conversion (conversion X) 1/fN - (128*1/fOSC) after DRDY initially goes active low. Failure to start the read cycle may result
in conversion X + 1 data overwriting conversion X results. For
example, with fOSC = 10MHz, fN = 2kHz, the read cycle must
start within 1/2000 - 128(1/106) = 487µs after DRDY went low.
SB - Bit 3 is the Standby Mode enable bit used to put the
HI7191 in a lower power/standby mode. When this bit is set
(SB = 1) the filter nodes are halted, the DRDY line is set high
and the modulator clock is disabled. When this bit is cleared
the HI7191 begins operation as described by the contents of
the Control Register. For example, if the Control Register is
programmed for Self Calibration Mode and a notch frequency
to 10Hz, the HI7191 will perform the self calibration before
providing the data at the 10Hz rate. This bit is cleared after a
RESET is applied to the part.
2) The Data Output Register read cycle for conversion X must
be completed within 2(1/fN)-1440(1/fOSC) after DRDY initially
goes active low. If the read cycle for conversion X is not complete within this time the results of conversion X + 1 are lost
and results from conversion X + 2 are now stored in the data
output word buffer.
BD - Bit 2 is the Byte Direction bit used to select the multi-byte
access ordering. The bit determines the either ascending or
descending order access for the multi-byte registers. When
set (BD = 1) the user can access multi-byte registers in
ascending byte order and when cleared (BD = 0) the multibyte registers are accessed in descending byte order. This bit
is cleared after a RESET is applied to the part.
MSB - Bit 1 is used to select whether a serial data transfer is
MSB or LSB first. This bit allows the user to change the order
that data can be transmitted or received by the HI7191. When
this bit is cleared (MSB = 0) the MSB is the first bit in a serial
data transfer. If set (MSB = 1), the LSB is the first bit transferred in the serial data stream. This bit is cleared after a
RESET is applied to the part.
SDL - Bit 0 is the Serial Data Line control bit. This bit selects
the transfer protocol of the serial interface. When this bit is
cleared (SDL = 0), both read and write data transfers are done
using the SDIO line. When set (SDL = 1), write transfers are
done on the SDIO line and read transfers are done on the SDO
line. This bit is cleared after a RESET is applied to the part.
Completing the Data Output Register read cycle inactivates
the DRDY interrupt. If the one word data output buffer is full
when this read is complete this data will be immediately transferred to the Data Output Register and a new DRDY interrupt
will be issued after the minimum DRDY pulse high time is met.
Writing the Control Register
If data is written to byte 2 and/or byte 1 of the Control Register
the DRDY output is taken high and the device re-calibrates if
written to a calibration mode. This action is taken because it is
assumed that by writing byte 2 or byte 1 that the user either
reprogrammed the filter or changed modes of the part. However, if a single data byte is written to byte 0, it is assumed that
the gain has NOT been changed. It is up to the user to re-calibrate the HI7191 after the gain has been changed by this
method. It is recommended that the entire Control Register be
written to when changing the selected gain. This ensures that
the part is re-calibrated before the DRDY signal goes low indicating valid data is available.
Offset Calibration Register
The Offset Calibration Register is a 24-bit register containing
the offset correction factor. This register is indeterminate on
power-up but will contain a Self Calibration correction value
after a RESET has been applied.
BYTE 2
Reading the Data Output Register
The HI7191 generates an active low interrupt (DRDY) indicating valid conversion results are available for reading. At this
time the Data Output Register contains the latest conversion
result available from the HI7191. Data integrity is maintained
at the serial output port but it is possible to miss a conversion
result if the Data Output Register is not read within a given
period of time. Maintaining data integrity means that if a Data
Output Register read of conversion N is begun but not finished before the next conversion (conversion N + 1) is complete, the DRDY line remains active low and the data being
read is not overwritten.
In addition to the Data Output Register, the HI7191 has a one
conversion result storage buffer. No conversion results will be
lost if the following constraints are met.
MSB
22
21
20
19
18
17
16
O23
O22
O21
O20
O19
O18
O17
O16
15
14
13
12
11
10
9
8
O15
O14
O13
O12
O11
O10
O9
O8
7
6
5
4
3
2
1
LSB
O7
O6
O5
O4
O3
O2
O1
O0
BYTE 1
BYTE 0
The Offset Calibration Register holds the value that corrects
the filter output data to all 0’s when the analog input is 0V.
1916
HI7191
Positive Full Scale Calibration Register
Negative Full Scale Calibration Register
The Positive Full Scale Calibration Register is a 24-bit register containing the Positive Full Scale correction coefficient.
This coefficient is used to determine the positive gain slope
factor. This register is indeterminate on power-up but will
contain a Self Calibration correction coefficient after a
RESET has been applied.
The Negative Full Scale Calibration Register is a 24-bit register containing the Negative Full Scale correction coefficient. This coefficient is used to determine the negative gain
slope factor. This register is indeterminate on power-up but
will contain a Self Calibration correction coefficient after a
RESET has been applied.
BYTE 2
BYTE 2
MSB
22
21
20
19
18
17
16
MSB
22
21
20
19
18
17
16
P23
P22
P21
P20
P19
P18
P17
P16
N23
N22
N21
N20
N19
N18
N17
N16
15
14
13
12
11
10
9
8
15
14
13
12
11
10
9
8
P15
P14
P13
P12
P11
P10
P9
P8
N15
N14
N13
N12
N11
N10
N9
N8
7
6
5
4
3
2
1
LSB
7
6
5
4
3
2
1
LSB
P7
P6
P5
P4
P3
P2
P1
P0
N7
N6
N5
N4
N3
N2
N1
N0
BYTE 1
BYTE 1
BYTE 0
BYTE 0
1917
HI7191
Die Characteristics
DIE DIMENSIONS:
SUBSTRATE POTENTIAL (Powered Up):
3550µm x 6340µm
AVSS
METALLIZATION:
PASSIVATION:
Type: AlSiCu
Thickness: Metal 2, 16kÅ
Metal 1, 6kÅ
Type: Sandwich
Thickness: Nitride 8kÅ
USG 1kÅ
Metallization Mask Layout
RESET
SYNC
MODE
SCLK
SDO
SDIO
HI7191
OSC1
CS
DRDY
OSC2
DGND
DVDD
AVSS
1918
AVDD
VINHI
VINLO
VCM
VRHI
VRLO
AGND
HI7191
Dual-In-Line Plastic Packages (PDIP)
E20.3 (JEDEC MS-001-AD ISSUE D)
N
20 LEAD DUAL-IN-LINE PLASTIC PACKAGE
E1
INDEX
AREA
1 2 3
INCHES
N/2
MILLIMETERS
SYMBOL
MIN
MAX
MIN
MAX
NOTES
A
-
0.210
-
5.33
4
A1
0.015
-
0.39
-
4
A2
0.115
0.195
2.93
4.95
-
-B-AE
D
BASE
PLANE
A2
-C-
SEATING
PLANE
A
L
D1
e
B1
D1
B
0.010 (0.25) M
A1
eC
C A B S
B
0.014
0.022
0.356
0.558
-
C
L
B1
0.045
0.070
1.55
1.77
8
eA
C
0.008
0.014
D
0.980
1.060
24.89
D1
0.005
-
E
0.300
0.325
E1
0.240
0.280
C
eB
NOTES:
1. Controlling Dimensions: INCH. In case of conflict between English
and Metric dimensions, the inch dimensions control.
2. Dimensioning and tolerancing per ANSI Y14.5M-1982.
3. Symbols are defined in the “MO Series Symbol List” in Section 2.2
of Publication No. 95.
4. Dimensions A, A1 and L are measured with the package seated in
JEDEC seating plane gauge GS-3.
5. D, D1, and E1 dimensions do not include mold flash or protrusions.
Mold flash or protrusions shall not exceed 0.010 inch (0.25mm).
6. E and eA are measured with the leads constrained to be perpendicular to datum -C- .
7. eB and eC are measured at the lead tips with the leads unconstrained. eC must be zero or greater.
8. B1 maximum dimensions do not include dambar protrusions. Dambar protrusions shall not exceed 0.010 inch (0.25mm).
9. N is the maximum number of terminal positions.
10. Corner leads (1, N, N/2 and N/2 + 1) for E8.3, E16.3, E18.3, E28.3,
E42.6 will have a B1 dimension of 0.030 - 0.045 inch (0.76 - 1.14mm).
1919
e
0.300 BSC
eB
-
L
0.115
20
0.355
-
26.9
5
0.13
-
5
7.62
8.25
6
6.10
7.11
5
0.100 BSC
eA
N
0.204
2.54 BSC
-
7.62 BSC
6
0.430
-
0.150
2.93
10.92
3.81
20
7
4
9
Rev. 0 12/93
HI7191
Small Outline Plastic Packages (SOIC)
M20.3 (JEDEC MS-013-AC ISSUE C)
20 LEAD WIDE BODY SMALL OUTLINE PLASTIC PACKAGE
N
INDEX
AREA
H
0.25(0.010) M
B M
INCHES
E
-B1
2
3
L
SEATING PLANE
-A-
h x 45o
A
D
-C-
e
A1
B
0.25(0.010) M
C
0.10(0.004)
C A M
SYMBOL
MIN
MAX
MIN
MAX
NOTES
A
0.0926
0.1043
2.35
2.65
-
A1
0.0040
0.0118
0.10
0.30
-
B
0.013
0.0200
0.33
0.51
9
C
0.0091
0.0125
0.23
0.32
-
D
0.4961
0.5118
12.60
13.00
3
E
0.2914
0.2992
7.40
7.60
4
e
α
B S
0.050 BSC
1.27 BSC
-
H
0.394
0.419
10.00
10.65
-
h
0.010
0.029
0.25
0.75
5
L
0.016
0.050
0.40
1.27
6
N
NOTES:
1. Symbols are defined in the “MO Series Symbol List” in Section 2.2 of
Publication Number 95.
2. Dimensioning and tolerancing per ANSI Y14.5M-1982.
3. Dimension “D” does not include mold flash, protrusions or gate burrs.
Mold flash, protrusion and gate burrs shall not exceed 0.15mm (0.006
inch) per side.
4. Dimension “E” does not include interlead flash or protrusions. Interlead
flash and protrusions shall not exceed 0.25mm (0.010 inch) per side.
5. The chamfer on the body is optional. If it is not present, a visual index
feature must be located within the crosshatched area.
6. “L” is the length of terminal for soldering to a substrate.
7. “N” is the number of terminal positions.
8. Terminal numbers are shown for reference only.
9. The lead width “B”, as measured 0.36mm (0.014 inch) or greater
above the seating plane, shall not exceed a maximum value of
0.61mm (0.024 inch)
10. Controlling dimension: MILLIMETER. Converted inch dimensions
are not necessarily exact.
MILLIMETERS
α
20
0o
20
8o
0o
7
8o
Rev. 0 12/93
All Intersil semiconductor products are manufactured, assembled and tested under ISO9000 quality systems certification.
Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design and/or specifications at any time without
notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate
and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which
may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries.
For information regarding Intersil Corporation and its products, see web site http://www.intersil.com
Sales Office Headquarters
NORTH AMERICA
Intersil Corporation
P. O. Box 883, Mail Stop 53-204
Melbourne, FL 32902
TEL: (407) 724-7000
FAX: (407) 724-7240
EUROPE
Intersil SA
Mercure Center
100, Rue de la Fusee
1130 Brussels, Belgium
TEL: (32) 2.724.2111
FAX: (32) 2.724.22.05
1920
ASIA
Intersil (Taiwan) Ltd.
Taiwan Limited
7F-6, No. 101 Fu Hsing North Road
Taipei, Taiwan
Republic of China
TEL: (886) 2 2716 9310
FAX: (886) 2 2715 3029