GOXX0005
FAN DETECTION BOARD
(DETECTS THE ABSENCE
OF FAN CURRENT)
LINE VOLTAGE UP TO 230V
FAN CURRENT UP TO 6A
NO/NC OUTPUT SWITCH
The GOXX0003 detects the absence of current circulating in the fan. This can be used for
ventilation fault signal generation in power semiconductor assembly
Characteristic
ILOAD (RMS)
Maximum fan current
V (RMS)
VINS (RMS)
Maximum voltage (fan side)
Conditions
Value
6 A
230 V
Insulation voltage
2000 V
RELAY CONTACT CHARACTERISTICS
VMAX
(DC)
IMAX (DC)
Maximum voltage (across contact)
30 V
Maximum current (through contact)
2 A
Expected electrical life
Number of operations
Expected mechanical life
Number of operations
105
108
MECHANICAL AND THERMAL CHARACTERISTICS
W
Width
40 mm
Depth
50 mm
Height
25 mm
Weight
21 g
Standoff hole diameter
4.5 mm
2
1.5 mm
Max allowed wire gauge
16 AWG
Ta max
Max amb. op. Temp.
40 °C
Tstg
Storage temperature
-40/60 °C
Document GOXX0005T001
FAN DETECTION BOARD
GOXX0005
FUNCTIONAL SCHEMATIC
MECHANICAL DRAWING
LEGEND
Terminal Function
JP 1-1
JP 1-2
JP 2-1
JP 2-2
JP 2-3
AC
AC
NC
COM
NO
Drawing not to scale
All dimensions in mm
In the interest of product improvement Green Power Solutions reserves the right to change any specification given in this data sheet