Special Function Rotary Switches SERIES 08,09,42

Special Function Rotary Switches
SERIES 08,09,42,44,50
Spring Return
FEATURES
• Hold-To-Test, Hold-To-Calibrate,
And Other Momentary Applications
• Choice of Configurations, Ratings,
Styles and Circuitry
• 10,000 Cycles of Operation
DESCRIPTION
A spring return rotary switch has 1 or more momentary positions. Maintaining contact at momentary
positions requires rotational force. Releasing the force allows the mechanism to return the contact
to a normal, or detent, position.
DIMENSIONS
Series 08 & 09
Series 50
Equivalent to Series 50 Standard Switches
.500 ± .015
(12,7 ± 0,38)
DIA.
DIM. A + .046 (1,17)
–.020 (0,51)
DIM. B REF.
STUD PROJECTION
.320 ± .015 (8,13 ± 0,38)
CIRCLE OF CENTERS
COMMON
No. of
Decks
.960
1.228
1.496
1.764
2.032
2.550
(24,38)
(31,19)
(38,0)
(44,81)
(51,61)
(64,77)
Dim
B
.062
.062
.062
.062
.062
.312
Series 42 & 44
DIM. A + .046 (1,17)
–.020 (0,51)
(1,57)
(1,57)
(1,57)
(1,57)
(1,57)
(7,92)
No. of
Decks
1
2
3
For all other dimensions and
specifications, see Standard
Switch pages.
Dim.
A
1.025 (26,04)
1.371 (34,82)
1.717 (43,61)
For all other dimensions and
specifications, see Standard
Switch pages.
CONFIGURATIONS
SELECTING A SWITCH
OPTIONS
This configuration indicates a counterclockwise
force is required to hold the switch at position
#1. “M” indicates a momentary position
counterclockwise of “D” and "D", detented ones.
Positions
1
2
3
M D
D
Releasing this force breaks contact with position
#1 and returns the switch to #2. Normal rotary
switch detent action occurs when the switch is
rotated between position #2 and #3.
1. Select a Configuration: The total number of
positions always includes the 2 basic positions.
A (4) position switch of DDDDM configuration
would have 3 detent positions counterclockwise
of the momentary position.
Watertight panel seal; Multi-pole switches that
exceed the limits noted in the Selector Chart;
Series 50 MD or DM configurations in Military
styles; Series 08, 09, & 44 in MMMDM MM, and
in MMDD MM, and in MMMMMD.
Not available through Distributors
All of the configurations (except MDM) list a
basic 2 position arrangement which is shown in
italics. Example: MDDDDD or DDDDDM. Several
positions can be added during the switch
construction at the factory; but, any configuration
must always contain the 2 basic positions.
2. Select Series, Angle of Throw, and Style:
See the Choices Chart. The basic switch
description, series, and throw are as follows:
1
/2", 1/4 Amp, multi-deck
08 = 36° 09 = 30°
1", 1 Amp, multi-deck
42 = 36° 44 = 30°
1
/2", 200 mA, single deck 50 = 36°
Electrical ratings are the same as those of the
conventional switches with the exception of life.
Life is limited to 10,000 cycles of operation
(25,000 cycles for Series 50) due to the spring
arrangement. Dimensions are the same as for
conventional types except for the shaft flat
orientation of the 3, 4, 5, and 6 pole, Series 09
and 44 in the DDDDDM configuration (see
chart).
3. Select Poles & Positions Per Pole: If you
do not find the poles and positions per pole you
need in one series, try another or contact the
factory. If the behind panel length is a problem,
select a multi-pole type instead of a single deck.
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois
ORDERING INFORMATION
Create the part number using this example.
Stem number from chart
(4 or 5 digits)
Number of Decks
Number of Poles/Deck
093103-2-045
Type of Contacts:
S=Shorting
N=Non-Shorting
Number of Positions/Pole
Exception: Numbers beginning with 5 are
already complete part numbers.
60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
Rotary Switches
1
2
3
4
5
6
Dim
A
For all other dimensions and
specifications, see Standard
Switch pages.
36°
± 3°
Special Function Rotary Switches
CHOICES AND LIMITATIONS
Configuration
Conventional
Switch
08A36
Description
Of
Style
Standard
Spring Return
Stem Number
(See Ordering Info.)
08317
Poles
Per
Deck
Positions Per
Pole & Contact
Type
Location Of
Unique Position,
Detent or Momentary
Term.
Opp.
Flat**
1 to 6
1 to 3
1
2
02 to 05 (N or S)
02 to 05 (N or S)
M5
M 5, 10
5
5
1 to 6
1 to 3
1 or 2
1
1
1
2
3
4
5 or 6
02 to 06 (N or S)
02 to 06 (N or S)
02 to 04 (N or S)
02 or 03 (N or S)
02 (N or S)
M6
M 6, 12
M 4, 8, 12
M 3, 6, 9, 12
M 2, 4, 6, 8, 10, 12
6
6
4
3
2
09A30
Standard
09310
42A36
Standard
42349
1 to 3
1
1
2
02 to 05 (N or S)
02 to 05 (N or S)
M5
M 5, 10
5
5
42M36
Military
42352
1 to 3
1
1
2
02 to 05 (N or S)
02 to 05 (N or S)
M5
M 5, 10
5
5
44A30
Standard
44346
1 to 3
1
1
2
02 to 06 (N or S)
02 to 06 (N or S)
M6
M 6, 12
6
6
44M30
Military
44350
1 to 3
1
1
2
02 to 06 (N or S)
02 to 06 (N or S)
M6
M 6, 12
6
6
08A36
Standard
08319
1 to 6
1 to 3
1
2
02 to 05 (N or S)
02 to 05 (N or S)
M1
M 1, 6
1
1
1
2
3
4
5 or 6
02 to 06 (N or S)
02 to 06 (N or S)
02 to 04 (N or S)
02 or 03 (N or S
02 (N or S)
M1
M 1, 7
M 1, 5, 9
M 1, 4, 7, 10
M 1, 3, 5, 7, 9, 11
1
1
1
1
1
DDDDDM
09A30
Standard
09312
1 to 6
1 to 3
1 or 2
1
1
09M30
Military
09356
1 to 3
1
1
1
2
3
02 to 06 (N or S)
02 to 06 (N or S)
02 to 04 (N or S)
M1
M 1, 7
M 1, 5, 9
1
1
1
42A36
Standard
42350
1 to 3
1
1
2
02 to 05 (N or S)
02 to 05 (N or S)
M1
M 1, 6
1
1
42M36
Military
42353
1 to 3
1
1
2
02 to 05 (N or S)
02 to 05 (N or S)
M1
M 1, 6
1
1
44A30
Standard
44312
1 to 3
1
1
2
02 to 06 (N or S)
02 to 06 (N or S)
M1
M 1, 7
1
1
44M30
Military
44351
1 to 3
1
1
2
02 to 06 (N or S)
02 to 06 (N or S)
M1
M 1, 7
1
1
50A36
Std., Solder Lug
503265-1-03N*
1
1
03N
D2
2
50P36
Std., PC Mount
503267-1-03N*
1
1
03N
D2
2
8A36
Standard
08316
1 to 6
1 to 3
1
2
03 (N or S)
03 (N or S)
D2
D 2, 7
2
2
9A30
Standard
09311
1 to 6
1 to 3
1 or 2
1
1
2
3
4
03 (N or S)
03 (N or S)
03 (N or S)
03 (N or S)
D2
D 2, 8
D 2, 6, 10
D 2, 5, 8, 11
2
2
2
2
42A36
Standard
42348
1 to 3
1
1
2
03 (N or S)
03 (N or S)
D2
D 2, 7
2
2
42M36
Military
42351
1 to 3
1
1
2
03 (N or S)
03 (N or S)
D2
D 2, 7
2
2
44A30
Standard
44345
1 to 3
1
1
2
03 (N or S)
03 (N or S)
D2
D 2, 8
2
2
44M30
Military
44349
1 to 3
1
1
2
03 (N or S)
03 (N or S)
D2
D 2, 8
2
2
MDDDDD
Rotary Switches
MDM
No.
Of
Decks
*This is a complete (not stem) part number.
**Terminal opposite shaft flat when switch
is in its unique (detent or momentary)
position.
Available from your local Grayhill Distributor
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois
For prices and discounts, contact a local Sales
Office, an authorized local Distributor, or Grayhill.
60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
Special Function Rotary Switches
SERIES 09, 42, 44, 50, 51
Isolated Position
FEATURES
• Protected Switch Positions For
Safety, Calibration, or Stand-by
• Choice of Push- or Pull-To-Turn
• 1/2" Diameter, 200 mA and
1" Diameter, 1 Amp Switch
• 10,000 Cycles of Operation
DESCRIPTION
An isolated position is one which cannot be reached by the normal rotation. An additional action is
required by the operator. It could be either Push-To-Turn, or Pull-To-Turn. After the switch is rotated
to the isolated position, releasing the shaft locks the switch in that position. Push or pull again to
rotate the switch again.
Use isolated positions to protect a switch position from indiscriminate rotation. Such safety positions
might include “calibrate”, “off” and/or “stand-by”.
DIMENSIONS
Series 09
Series 42 & 44
Series 50 & 51
DIM. A + .046 (1,17)
–.020 (0,51)
DIM. A
.062 (1,57)
Rotary Switches
DIM. A
DIM. A + .046 –.020
(+ 0,05 –0,51)
SOLDER
LUGS
PC
TERMINALS
Dimension A
1 Deck
2 Decks
3 Decks
4 Decks
1.228
1.496
1.764
2.032
(31,19)
(38,0)
(44,81)
(51,61)
Dimension A
Dimension A
Solder Lug
PC Style
.893 ± .025 (22,68 ± 0,64)
.897 ± .025 (22,78 ± 0,64)
1 Deck
2 Decks
3 Decks
4 Decks
1.371
1.717
2.063
2.409
(34,82)
(43,61)
(52,40)
(61,19)
Grayhill part number and date code marked on label.
Customer number marked on request.
EXTERNAL DIFFERENCES
SPECIFICATIONS
The isolated position mechanism increases the
depth of the Series 50 and 51 by 0.217" (5,51
mm). All other dimensions remain unchanged.
In Series 9, 42 and 44, it has the appearance of
an additional deck section without terminals,
located directly behind the detent system.
Electrical Ratings
Materials and Finishes
The switching elements, and therefore ratings,
are the same in an isolated position switch as in
a conventional rotary switch. Mechanical life is
also the same.
Materials and finishes for the isolation
mechanism are listed here.
Series 50 and 51
Housing: Zinc casting, tin/zinc-plated
Shaft: 303 stainless steel
Stop Pin and Stop Post: 303 stainless steel
Spring: Tinned music wire
Series 09
Housing: Phenolic for style A; Diallyl, for M
Shaft: 303 stainless steel, electro-polished
Stop Pin and Stop Post: 303 stainless steel
Spring: Tinned music wire
Series 42 and 44
Housing: Diallyl per MIL-M-14
Shaft: 303 stainless steel
Lock Plate: 302 stainless steel
Lock Arm: 316 stainless steel
Lock Post: Brass, tin/zinc-plated
Compression Spring: Tinned music wire
Additional Characteristics
Shaft Movement or Vertical Travel:
Series 09
.062 ± .020 (1,57 ± 0,51)
Series 42 & 44
.070 ± .020 (1,78 ± 0,51)
Series 50 & 51
.080 ± .020 (2,03 ± 0,51)
Push or Pull Force Required:
Series 09
1.75 ± .5 lbs
Series 42 & 44
2 ± .5 lbs
Series 50 & 51
2 ± .5 lbs
Stops: Single pole per deck switches with the
maximum number of positions are supplied with
stops only on request: 12 positions in 30° throw,
10 in 36°, and 8 in 45°.
Stop Strength: Approximately 7.5 pound-inches
for the isolated position stop.
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois
60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
Special Function Rotary Switches
CHOICES AND LIMITATIONS
Standard
Style
Military
Style**
Style
Description
Angle Of
Throw
09A
09M
Solder Lug
42A
42S
—
—
42M
—
42H
42HS
Solder Lug
Sealed
125° Temperature Rating
125° Temp Rating, Sealed
Poles Per
Deck
Positions
Per Pole
01 to 04
01 to 04
01 to 04
01 to 04
01 to 04
01 to 03
1
2
3
4
5
6
02 to 12
02 to 06
02 to 04
02 or 03
02
02
N or S
N or S
N or S
N or S
N or S
N or S
01 to 04
01 to 04
1
2
02 to 10
02 to 05
N or S
N or S
01 to 04
01 to 04
01 to 04
01 to 04
01 to 04
01 to 04
1
2
3
4
5
6
02 to 12
02 to 06
02 to 04
02 or 03
02
02
N or S
N or S
N or S
N or S
N or S
N or S
45°
01 to 04
01 to 03
01 or 02
01 or 02
1
2
3
4
02 to 08
02 to 04
02
02
N or S
N or S
N or S
N
36°
01
1
2
02 to 10
02 to 05
N or S
N or S
30°
01
1
2
3
4
02 to 12
02 to 06
02 or 03
02 or 03
N or S
N or S
N or S
N or S
30°
36°
30°
44A
44S
—
—
44M
—
44H
44HS
Solder Lug
Sealed
125° Temperature Rating
125° Temp Rating, Sealed
-----
50C
50CP
50M*
50MP*
Solder Lug
PC Mount
Solder Lug, Sealed
Sealed, PC
-----
51C
51CP
51M*
51MP*
Solder Lug
PC Mount
Solder Lug, Sealed
PC Mount, Sealed
Shorting Or
Non-Shorting
*(Pull-to-Turn only) **For specifics on military qualified products, see Standard Switch Pages.
CONVENTIONAL NUMBERS
Start by creating a conventional switch number
in the manner which follows:
Series & Style
Angle of Throw
Number of Decks
09A30-01-1-12N
Type of Contacts
Shorting = S
Non-Shorting = N
Positions Per Pole
Poles Per Deck
Note: No stop arrangement suffix is needed.
See Describing Stops.
DESCRIBING POSITIONS
The Grayhill system for isolating positions lets
you choose the positions to be isolated. Grayhill
inserts isolation posts next to the positions to be
isolated. Consider a continuous rotation switch
of the Series 09A with a 30° angle of throw. The
terminals are listed here from 1 through 12 with
a space between each to indicate where isolation
posts might be inserted.
12 1 2 3 4 5 6 7 8 9 10 11 12
Let's isolate position 1 and position 2 from all
other positions and from each other. We indicate
isolation posts as shown here:
12P1P2P3 4 5 6 7 8 9 10 11 12
To isolate just position 1, describe like this:
12P1P2 3 4 5 6 7 8 9 10 11 12
To isolate positions 1 and 2 from all other
positions, but not from each other, do this:
12P1 2P3 4 5 6 7 8 9 10 11 12
ORDERING INFORMATION
Indicate this as a SPECIAL switch to ensure
that no error is made when the order is entered.
Sample part number:
SPECIAL
09A30-04-1-12N
PULL 12P1P2P3 4 5 6 7 8 9 10 11 12
DESCRIBING STOPS
When a 1-pole switch has less than the maximum
number of positions, consider also the stop
system. Following is the arrangement for a 6
position switch with the position 1 isolated.
STOP 1P2 3 4 5 6 STOP
The word “STOP” indicates the conventional
switch stops, which limit rotation to positions 1
through 6. To isolate position 1 we insert only
one isolation post–between terminals 1 and 2.
The stop system already prevents rotation
beyond terminal 1.
In multi-pole switches, the stop system and
isolation system described for the first pole,
automatically affects the other poles. In the
example above, isolating position #1 on the first
pole isolates the first position (terminal #7) of
the second pole. See Standard Switch Pages
for a 2 pole circuit diagram for a 30° throw
switch.
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois
This sample part number orders a Series 9
standard style, four deck, one pole per deck,
twelve positions per pole rotary switch with nonshorting contacts and isolation posts between
positions 12 and 1, between 1 and 2, and
between 2 and 3.
This lengthy order number is required to prevent
any possible confusion in ordering the switch.
When we receive your order, we will assign a
special “short form” part number to facilitate
future identification of this special switch. This
number is sequentially assigned as the need
arises, and is non-descriptive. A typical “short
form” special part number might be 09YY12345.
Contact Grayhill for price.
Not available through Distributors.
60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
Rotary Switches
No. Of
Decks