Correlating Microwave Measurements between Handheld

FieldFox Handheld
Education Series Part 6:
Correlating Microwave
Measurements between
Handheld and Benchtop
Analyzers
FieldFox Handheld Education Series
• Interference Testing
• Cable and Antenna Measurements
• Calibration and Alignment
• Time Domain Measurements
• Precise Power Measurements
• Precise Data Correlation
www.agilent.com/find/FieldFoxWebcasts
Tom Hoppin
Business Development Manager
Co-sponsored by:
© 2012 Agilent Technologies
July 24th, 2013
July 24 2013
Correlating Microwave Measurements
between Handheld and Benchtop
Analyzers
For the purposes of this tutorial, we will use the term “correlation” to
describe agreement of data measured on different instruments
2
July 24th, 2013
Outline
• Laboratory and Field Measurements
• Application Examples
• Correlating Measurements
• Handheld Technologies
• Remote Operation
• Conclusions
3
July 24th, 2013
Lifecycle for Microwave Product Testing
Measurements required at
• Research / Prototyping
• Product Development
• Manufacturing
Laboratory
Test
• Installation
Field
Test
• Maintenance
• Troubleshooting
Measurements must be
• Accurate
• Repeatable
4
Correlation
between Lab and
Field
Production
Testing
Field Testing
July 24th, 2013
Laboratory and Field Measurements
R&D Setup
Field Testing
Data
Correlation
“All-in-one”
Handheld
FieldFox handhelds have comparable performance to
benchtop instruments
5
July 24th, 2013
Application Example: Field Testing a Radar System
Pack
Ship
Site Delivery
AC Power
System Test
Benchtop Instruments
Breakdown
Pack
Ship
6
July 24th, 2013
Application Example: Field Testing a Radar System
Pack
Ship
Site Delivery
AC Power
System Test
Benchtop Instruments
• 1 month start to finish
• Lock up >$150K equipment
7
Breakdown
Pack
Ship
July 24th, 2013
“Combination” Handheld for Field Use
Luggage Pack
Carry
System Test
Luggage Pack
Microwave FieldFox
Combination Analyzer
Combination Handheld includes
• RF Power Meter
• Spectrum Analyzer
• Vector Network Analyzer
• DC Source Voltage/Current Meter
Carry
2 Days
Benchtop Measurements = Handheld Measurements
8
July 24th, 2013
Handheld and Benchtop Correlation – S Parameters
Overlay S11, S21
Measurements
PNA-X
Benchtop
DUT is 10.24 GHz
Passband Filter
FieldFox
Handheld
Correlation Values
9
D Mkr (PNA-FF)
S11 (dB)
S21 (dB)
Mkr 2 Passband
0.02
0.02
Mkr 1 Reject Left
-0.02
-0.52 @ 78dB down
Mkr 3 Reject Right
0.00
-0.12 @ 65dB down
Benchtop and
handheld
measurements
correlate very
well.
July 24th, 2013
Handheld and Benchtop Correlation – S Parameters
Overlay S11, S21
Measurements
PNA-X
Benchtop
DUT is 10.24 GHz
Passband Filter
FieldFox
Handheld
Correlation Values
10
D Mkr (PNA-FF)
S11 (dB)
S21 (dB)
Mkr 2 Passband
0.02
0.02
Mkr 1 Reject Left
-0.02
-0.52 @ 78dB down
Mkr 3 Reject Right
0.00
-0.12 @ 65dB down
Benchtop and
handheld
measurements
correlate very
well.
July 24th, 2013
Application Example: Prototype Testing
Test Requirements
Prototype Limiting Amplifier
1.
2.
3.
4.
5.
6.
7.
8.
Output RF Power
Harmonics
Spurs
Bandwidth
Gain
VSWR
Isolation
DC Power
Power
Spectrum
S-parameters
11
July 24th, 2013
Application Example: Prototype Testing
Equipment
Prototype Limiting Amplifier
1.
2.
3.
4.
5.
6.
7.
8.
Output RF Power
Harmonics
Spurs
Bandwidth
Gain
VSWR
Isolation
DC Power
RF Source / RF Power Meter
Spectrum Analyzer
Vector Network Analyzer
DC Supply / Multimeter
Power
Spectrum
S-parameters
12
July 24th, 2013
Prototype Testing: Benchtop or Handheld ?
Typical R&D Setup
Combination Handheld
Analyzer
N9918A
26.5 GHz
FieldFox
Create elaborate test bench
13
• RF Power Meter
• Spectrum Analyzer
• Vector Network Analyzer
• RF Signal Source
• DC Source / Multimeter
July 24th, 2013
Prototype Testing: Benchtop or Handheld ?
Typical R&D Setup
Combination Handheld
Analyzer
Correlation
Create elaborate test bench
14
N9918A
26.5 GHz
FieldFox
• RF Power Meter
• Spectrum Analyzer
• Vector Network Analyzer
• RF Signal Source
• DC Source / Multimeter
July 24th, 2013
Equipment Choices for RF Power Measurement
Sensor
Laptop with Software
Meter
USB Cable
USB Sensor
FieldFox
FieldFox
(CPM)
USB Cable
USB Sensor
15
RF Jumper
Cable
No sensor required
July 24th, 2013
RF Power Measurement
Power
Width = 20msec
PRI = 100msec
Average
Power
U2000A USB Power Sensor
DF = 20%
3 GHz Carrier
FieldFox CPM
No sensor required
16
July 24th, 2013
RF Power Over Frequency
Benchtop
Handheld
PSG Signal Generator
E4413A
Cable
Test
Point
N9918A
26.5 GHz
FieldFox
N1914A
Freq (GHz)
Sensor (dBm)
CPM (dBm)
0.1
-0.07
-0.10
18
-2.90
-2.84
26.5
-3.75
-3.71
Average Power Measurement, CW Signal
FieldFox InstAlign provides automatic internal alignment
• Valid over the full frequency range and operating temperature of -10 to +55°C
• No warm up required
17
July 24th, 2013
Spectrum Analyzer Correlation
Benchtop MXA
Handheld FieldFox
MXA:
Mkr Delta
-40.37 dB
18
FieldFox:
Mkr Delta
-40.07 dB
July 24th, 2013
Spectrum Analyzer Correlation
Benchtop MXA
Handheld FieldFox
MXA:
Mkr Delta
-40.37 dB
FieldFox:
Mkr Delta
-40.07 dB
Reduced Dynamic Range and Longer Sweep Time
19
July 24th, 2013
VNA Correlation
HP 8510C
20
S21
S11
S22
S12
8510
July 24th, 2013
VNA Correlation
HP 8510C
PNA-X
S21
S11
S22
S12
8510
PNA-X
21
July 24th, 2013
VNA Correlation
HP 8510C
PNA-X
FieldFox
S21
S11
S22
S12
8510
PNA-X
FieldFox
22
July 24th, 2013
FieldFox VNA Calibration Process
Traditional Calibration
1
2
S O L
Thru
S O L
Seven
connections
required
S
O
Requires calibration kit
T
23
L
July 24th, 2013
FieldFox VNA Calibration Process
Traditional SOLT Calibration
1
2
FieldFox QuickCal
1
2
Cal Plane
S O L
Open
Thru
S O L
Connect
Cal Plane
Seven
connections
required
S
No cal kit required
O
Requires calibration kit
T
24
L
• Ideal for Field Testing
• Also CalReady & Cal Wizard
July 24th, 2013
Comparing QuickCal and Mechanical Calibrations
Measurement of a Coaxial Cable
Two-Port Cal
QuickCal
25
July 24th, 2013
MMICs enable Performance, Power and Size
Monolithic Microwave Integrated
Circuits (MMIC)
QFN HF
Input
Reflectometer
Wilson LO's Simulating 1.08 GHz Input Signal
 80
First LO VC O Model
First LO Loop Model
R&S
Second LO VC O Model
Second LO Loop Model
Dif f erence
 85
COTS - Hittite
 90
 95
R&S – FSH8
 100
 105
dBc/H z
 110
WilsonMW
 115
 120
 125
 130
 135
 140
 145
Source Phase Noise
 150
100
110
3
110
4
110
5
110
6
110
7
Frequency
MMICs provide the highest level of integration
• High performance & correlation to benchtop
instruments
• Low power consumption, 14 watt (no fan or vents
needed).
RF Board
• Lightweight, 3 kg (6.6 lbs)
• High reliability, 3 year warranty
• MMICs designed and manufactured by Agilent
Microwave FieldFox
26
July 24th, 2013
Agilent’s High Frequency Technology Center
• Complete MMIC wafer design and fabrication capability
• Approx.150 wafers & 250,000 chips output per month
• Differentiate Agilent products / most IP not for sale
Agilent Santa Rosa, California
Over 300 MMICs
13k sq. ft. clean room
Spectrum
Analyzers
27
Network
Analyzers
Handheld
FieldFox
July 24th, 2013
FieldFox has Benchtop Measurement Science
FieldFox analyzers share the same
measurement science from the best
network and spectrum analyzers.
“FieldFox’s result is almost identical to my PNA.
I want one of these for all of my engineers.”
-Senior calibration engineer from spacecraft research and development center.
28
July 24th, 2013
Application Example: Microwave Backhaul
• Critical to 3G/4G Networks
• 200 Mbps to over 1 Gbps
• Challenging test conditions
• Numerous measurements
• Minimize system downtime
• Factory and field correlation
29
July 24th, 2013
Application Example: Microwave Backhaul Test
30
CAT: Line sweep
SA: Antenna alignment
CPM: Transmit Power
SA: Frequency Verification
SA: Path Loss Verification
VNA: Combiner tuning
July 24th, 2013
Remote Control via iOS devices
Apple® iPAD ® Interface
• Remote Viewer iOS App (Apple® Store)
• Remote Control Capability
31
July 24th, 2013
FieldFox Rugged to MIL-PRF-28800F Class 2
MIL-spec durability
Meets MIL-PRF-28800F Class 2 requirements
Type tested and meets MIL-STD-810G, Method 511.5 Procedure I
requirements for operation in explosive environments
Field-proof
Type tested to IP53: completely sealed instrument enclosure provides
measurement stability in dusty and wet environments
3-year warranty ensures field confidence (standard on all FieldFox
analyzers)
Low emissions, meets CISPR Pub 11, class B
Water-resistant chassis, keypad, and case withstand wide temperature
ranges, and salty, humid environments
• Case withstands shock and vibrations
• Wide operating temperature -10 to +55 °C (+14 to +131 °F)
• Wide storage temperature -51 to +71 °C (-60 to +160 °F)
32
July 24th, 2013
Agilent FieldFox Combination Analyzers
Combination Analyzers can be configured with the following capabilities
• Cable and Antenna Test (CAT)
• Vector Network Analyzer (VNA)
• Spectrum Analyzer
• Independent Source
• Vector Voltmeter (VVM)
• Power Meter
• Models include frequencies up to 26.5 GHz
• 6.6 pounds (3 kg)
• Built-in GPS
• 3.5 hour battery life
Carry precision with you - Agilent-quality measurements
33
July 24th, 2013
Conclusions
Data correlation makes FieldFox ideal for accurate
performance validation of complex systems in the field
Data correlation means that FieldFox is an useful companion
(not a replacement) for benchtop instruments in the lab
MMIC technology and Agilent measurement science provides
the outstanding performance of FieldFox
Remote control using iOS devices provides value to field and
educational users
34
July 24th, 2013
For More Information
Web: www.agilent.com/find/FieldFox Email: [email protected]
Literature:
-
Techniques for Precise Interference Measurements in the Field, application note,
literature number 5991-0418EN
-
Techniques for Precise Cable and Antenna Measurements in the Field, application
note, literature number 5991-0419EN
-
FieldFox Handheld Analyzers, brochure, literature number 5990-9779EN
6th in a series of application webcasts
• Sept 26, 2012: Interference Testing
• Oct 24, 2012: Cable and Antenna Measurements
• Nov 28 2012: Calibration and Alignment
• Jan 23 2013: Time Domain Measurements
• Mar 27 2013: Precise Power Measurements
• Jul 24 2013: Precise Data Correlation
Registration: www.agilent.com/find/FieldFoxWebcasts
Co-sponsored by
Thank you for your time
Questions?
© 2012 Agilent Technologies
References
• Agilent Application Note, Techniques for Precise Interference Measurements in the Field Using FieldFox
handheld analyzers, Literature Number 5991-0418EN, February 2013
• Agilent Application Note, Techniques for Precise Cable and Antenna Measurements in the Field Using
FieldFox handheld analyzers, Literature Number 5991-0419EN, June 2013
• Agilent Application Note, Techniques for Time Domain Measurements Using FieldFox handheld
analyzers, Literature Number 5991-0420EN, March 2013
• Agilent Application Note, Techniques for Precise Calibrations in the Field Using FieldFox handheld
analyzers, Literature Number 5991-0421EN, February 2013
• Agilent Application Note, Techniques for Precise Power Measurements in the Field Using FieldFox
handheld analyzers, Literature Number 5991-0423EN
36
July 24th, 2013