Flat Type Chip Fuse

Flat Type Chip Fuse
Hokuriku Electric Industry Co.,Ltd
【Model No】
FCL10-***, FCL16-***, FCL20-***
【Feature】
■Suitable to portable electronic device for circuit protection.
■By HDK original structure, this is instantinstant-blowing type chip fuse.
■By HDK original process, it has excellent pulse characteristic.
■No smoking, no fire occur when fused.
■Europe RoHS compliant product.
【SIze】
(Unit:mm)
Model No
L
W
t
c
d
FCL10-***
1.00±0.05
0.50±0.05
0.34±0.05
0.20±0.10
0.25±0.10
FCL16-***
1.60±0.15
0.25±0.20
0.25±0.20
FCL20-***
2.00+0.20/-0.10
1.25+0.20/-0.10
0.45±0.05
0.25+0.10/-0.15
0.25+0.10/-0.15
Rated voltage
(VDC)
Breaking
current
(A)
Fusing performance
Operating
temperature
range
To be fused within 5
seconds when 200% of
rated current applied.
-55℃~125℃
0.80+0.20/-0.10 0.50+0.15/-0.10
【Shape turn composition】 FCL 10
①
-
201
②
V
③
[Specification]
Model No.
Marking
Rated current
(A)
Internal
resistance
(mΩ)Max
FCL10-201
FCL10-251
FCL10-321
FCL10-351
FCL10-381
FCL10-401
FCL10-501
FCL10-631
FCL10-751
FCL10-801
FCL10-102
FCL10-132
FCL10-142
FCL10-152
FCL10-162
FCL10-202
FCL10-252
FCL10-302
FCL10-322
C
D
E
F
G
H
K
L
M
N
P
R
4
S
U
X
Y
Z
3
0.200
0.250
0.315
0.350
0.375
0.400
0.500
0.630
0.750
0.800
1.000
1.250
1.400
1.500
1.600
2.000
2.500
3.000
3.150
1990
1350
850
650
590
530
320
220
181
135
115
100
90
85
58
42
35
27
25
50
24
* Design・specification are subject to change without prior notice. Please check before purchase and use.
HOKURIKU
35
Hokuriku Electric Industry Co.,Ltd
Model No.
Marking
Rated current
(A)
Internal
resistance
(mΩ)Max
FCL16-201
FCL16-251
FCL16-321
FCL16-351
FCL16-381
FCL16-401
FCL16-501
FCL16-631
FCL16-751
FCL16-801
FCL16-102
FCL16-132
FCL16-142
FCL16-152
FCL16-162
FCL16-202
FCL16-252
FCL16-302
FCL16-322
FCL16-402
FCL16-502
FCL20-201
FCL20-251
FCL20-321
FCL20-401
FCL20-501
FCL20-631
FCL20-801
FCL20-102
FCL20-132
FCL20-142
FCL20-162
FCL20-202
FCL20-252
FCL20-322
FCL20-402
FCL20-502
C
D
E
F
G
H
K
L
M
N
P
R
14
S
U
X
Y
Z
3
4
5
201
251
321
401
501
631
801
102
132
142
162
202
252
322
402
502
0.200
0.250
0.315
0.350
0.375
0.400
0.500
0.630
0.750
0.800
1.000
1.250
1.400
1.500
1.600
2.000
2.500
3.000
3.150
4.000
5.000
0.200
0.250
0.315
0.400
0.500
0.630
0.800
1.000
1.250
1.400
1.600
2.000
2.500
3.150
4.000
5.000
1990
1350
850
650
590
530
320
220
181
135
115
100
90
85
58
42
35
27
25
17
12
1990
1250
850
530
320
220
135
115
95
90
58
42
35
25
17
12
Rated voltage
(VDC)
Breaking
current
(A)
Fusing performance
Operating
temperature
range
50
To be fused within 5
seconds when 200% of
rated current applied.
-55℃~125℃
50
To be fused within 5
seconds when 200% of
rated current applied.
-55℃~125℃
50
32
50
32
[Structure] No.
1
2
3
4
5
6
7
8
9
10
Element Name
Ceramic substrate
Back electrode
Under coat
Fuse element Ⅰ
Fuse element Ⅱ
Protective coat
Marking
Side electrode
Ni plating
Sn plating
4
5
8
7
6
3
10
1
9
2
[Power rating]
■For fuse operated in ambient temperature above 70℃,
70 ℃, power rating must be derated in
accordance with the derating curve.
FCL
Power rating (%)
100
80
60
40
20
0
-55
0
70
Ambient temperature (℃)
* Design・specification are subject to change without prior notice. Please check before purchase and use.
HOKURIKU
125
Hokuriku Electric Industry Co.,Ltd
[Fusing Characteristic]
* Design・specification are subject to change without prior notice. Please check before purchase and use.
HOKURIKU
Hokuriku Electric Industry Co.,Ltd
[Fusing Characteristic]
[I2t-t characteristic]
* Design・specification are subject to change without prior notice. Please check before purchase and use.
HOKURIKU
Hokuriku Electric Industry Co.,Ltd
【Precautions for use matter】
・Please consult about use by all except for the specification indicated on this catalog beforehand.
・When using for the circuit which causes a plunge electric current, please confirm the tolerance to a plunge electric current sufficiently.
・Please don't use a fuse for the first side.
・Please confirm the ordinary use state and the special quality to the expected abnormality sufficiently.
・Of a fuse by a soldering iron, the temperature and time control install it and are inarticulate for correction, so I won't recommend you.
・Please don't assign soldering bit to a fuse terminal directly.* Please remove a mounted fuse once and don't re-apply.
・The specification indicated on this catalog is sometimes changed without notice.
・When you consider use to equipment of human life of loading and equipment with a possibility which causes enormous damage.
* Design・specification are subject to change without prior notice. Please check before purchase and use.
HOKURIKU