HOKURIKU FCL10-251V

Flat Type Chip Fuse
Hokuriku Electric Industry Co.,Ltd
【Model Number】
FCL10-***
【Features】
■Suitable to portable electronic device for circuit protection.
■By HDK original structure, this is instant-blowing type chip fuse.
■By HDK original process, it has excellent pulse characteristic.
■Due to 1005 size, minimizing of mounting area is possible.
■No smoking, no fire occur when fused.
■Europe RoHS compliant product.
【Dimensions】
(Unit: mm)
【Designation】
Model No.
L
W
t
c
d
FCL10-***
1.00±0.05
0.50±0.05
0.34±0.05
0.20±0.20
0.25±0.20
FCL10
①
-
201
②
V
③
①Model No.
Model No.
Size
FCL10
1005
②Rated Current
Marking
Rating(A)
201
0.200
251
0.250
321
0.315
351
0.350
381
0.375
401
0.400
501
0.500
631
0.630
751
0.750
801
0.800
102
1.000
132
1.250
152
1.500
162
1.600
202
2.000
252
2.500
302
3.000
③Packing Form
Symbol
Form
V
Paper tape
B
Bulk
【Specification】
Model No.
Marking
Rated current
A
Internal
resistance
momega
Rated voltage
(VDC)
Breaking
current (A)
Fusing performance
FCL10-201
0.200
1990
C
FCL10-251
0.250
1350
D
FCL10-321
0.315
850
E
FCL10-351
0.350
650
F
FCL10-381
0.375
590
G
FCL10-401
0.400
530
H
FCL10-501
0.500
320
K
FCL10-631
0.630
220
L
Rated current x200%
FCL10-751
0.750
181
24
35
blow-out within 5
M
seconds.
FCL10-801
0.800
135
N
FCL10-102
1.000
115
P
FCL10-132
1.250
100
R
FCL10-152
1.500
90
S
FCL10-162
1.600
58
U
FCL10-202
2.000
42
X
FCL10-252
2.500
35
Y
FCL10-302
3.000
27
Z
* Design・specification are subject to change without prior notice. Please check before purchase and use.
HOKURIKU
Operating
temperature
range
- 55 ℃ ~ 125
℃
Hokuriku Electric Industry Co.,Ltd
【Structure】
Element Name
No.
1
2
3
4
5
6
7
8
9
10
Ceramic substrate
Bottom electrode
Undercoat
Fuse element Ⅰ
Fuse element Ⅱ
Protective coat
4
5
8
7
6
3
1
9
Marking
2
Side electrode
Ni plating
Sn plating
【Power derating curve】
■When used at ambient temperature of 70℃
70℃ or above, power rating must be derated in accordance with
the derating curve. below.
FCL
100
Power rating (%)
80
60
40
20
0
-55
0
70
125
Ambient temperature (℃)
2
【I2t-t characteristic】
FCL
FCL10
10
10-302
FCL
FCL10
10
10-202
FCL
FCL10
10
10-252
FCL
FCL10
10
10-132
FCL
FCL10
10
10-152
FCL
FCL10
10
10-162
FCL
FCL10
10
10-801
FCL
FCL10
10
10-751
FCL
FCL10
10
10-102
FCL
FCL10
10
10-631
FCL
FCL10
10
10-401
FCL10
10FCL
10
-501
FCL
FCL10
10
10-381
FCL
FCL10
10
10-351
FCL
FCL10
10
10-321
FCL
FCL10
10
10-251
FCL
FCL10
10
10-201
【Fusing characteristic】
FCL10
FCL10 -302
FCL10
FCL10 -252
FCL10
FCL10 -202
FCL10
10 -162
FCL
FCL10
FCL10 -152
FCL10
FCL10 -132
FCL10
FCL10 -102
FCL10
FCL10 -801
FCL10
FCL10 -751
FCL10
FCL10 -631
FCL10
FCL10 -501
100.0000
10.0000
1
FCL10
FCL10 -401
FCL10
FCL10 -381
Joule
heat熱(A
s)
ジュール
ジュール熱
[A22s]
Fusing
time
溶断時間
溶断時間[s]
[s](s)
FCL10
FCL10 -351
0.1
0.01
1.0000
FCL10
FCL10 -321
FCL10
FCL10 -251
FCL10
FCL10 -201
0.1000
0.0100
0.001
0.0010
0.0001
0.1
1
10
100
0.0001
0.0001
0.001
0.01
0.1
1
Fusing
time
溶断時間[s]
[s] (s)
溶断時間
印加電流[A]
[A] (A)
印加電流
Applied
Current
【Caution on use】
-
Please consult in advance about the use of those other than the specification written in this catalog.
For use in the circuit which generates inrush current, please fully check durability against the inrush current.
Please do not use this fuse for primary side.
Please fully check characteristic against abnormality expected at normal use condition.
We do not recommend mounting or reworking of fuse by soldering iron, since control of temperature and time is unclear.
Please do not apply soldering iron to fuse terminal directly.
Please do not reuse the fuse which was once mounted.
Specification described in this catalog are subject to change without prior notice.
When use to the apparatus that could affect human lives, such as automotive, and the apparatus that may incur serious damage
is considered, please consult in advance.
* Design・specification are subject to change without prior notice. Please check before purchase and use.
HOKURIKU
10